HomeMy WebLinkAboutPVH HEALTH SYSTEMS, HARMONY CAMPUS, 4TH FILING, MOB (REDSTONE) - PDP - 32-98G - CORRESPONDENCE - (3)Number: 5 Created: 3/31/2004 [3/31/04] Landscaping needs to be shown on the east end of the parking lot perimeter. Number: 6 Created: 3/31/2004 [3/31/04] On the landscape plan, show plat counts and codes on the plan as well as counts on the key Number: 7 Created: 3/31/2004 [3/31/04] Show handicap ramps at HC spaces, crosswalks etc Number: 8 Created: 3/31/2004 [3/31/04] Any trash/recyclable enclosures proposed?? Please return all of your redlined plans when you re -submit. If you have any questions regarding these issues or any other issues related to this project, please feel free to call me at (970) 221-6750. Sincerely, Cameron Gloss Current Planning Director Page 5 Number: 26 Created: 4/21/2004 [4/21/04] Will the drive aisle that goes in front of the new medical building be extended to the east with future expansion? Number: 27 Created: 4/21/2004 [4/21/04] To separate pedestrians from motor vehicles in the large parking lot construct a walkway through the landscaped islands to the major walkway spine (see redlines). Department: Water Wastewater Issue Contact: Jeff Hill Topic: General Number: 17 Created: 4/21/2004 [4/21/04] Provide utility easements for all sanitary sewer mains and offsite utility easements for sanitary sewer services which cross adjacent lots. Number: 18 Created: 4/21/2004 [4/21/04] Include all appropriate water and sewer details with the final submittal. Number: 19 Created: 4/21/2004 [4/21/04] Our records indicate that a 4-inch and 6-inch water lines were stubbed out for this building. Clearly define the abandonment of the existing 4-inch water line and installation of the proposed 1 1/2-inch water service. Number: 20 Created: 4/21/2004 [4/21/04] See site, landscape and utility plans for other comments. Department: Zoning Issue Contact: Jenny Nuckols Topic: Zoning Number: 1 Created: 3/31/2004 [3/31/04] The dashed areas, denoting existing parking, will there still be some handicap spaces on the west side of the proposed building. Its unclear on the site plan Number: 2 Created: 3/31/2004 [3/31/04] Please remove topo lines from final site plan Number: 3 Created: 3/31/2004 [3/31/04] It doesn't look like the building meets our commercial building standards, there isn't any articulation, no apparent base or top treatments - its needs some pizzazz Number: 4 Created: 3/31/2004 [3/31/04] Building height needs to be shown on elevations as well as materials, colors etc. Page 4 Please discuss in the text of the report how water quality mitigation will be achieved. This should be included in the report before the hearing. Number: 29 Created: 4/21 /2004 Please provide a preliminary site -specific grading plan for the proposed site. This should be included in the utility plan set before the hearing. Number: 30 Created: 4/21/2004 At final plan review, all the coordination efforts between the various filings for the construction of the drainage improvements needs to be documented with this drainage report. Topic: Erosion/Sediment Control Number: 31 Created: 4/21 /2004 1. Plan will be reviewed when a complete sediment/erosion control plan is submitted per City of Fort Collins specifications. Department: Transfort Issue Contact: Garold Smith Topic: Zoning Number: 9 Created: 4/6/2004 No Comments Department: Transportation Planning Issue Contact: Tom Reiff Topic: Transportation Number: 23 Created: 4/21 /2004 [4/21/04] Please provide a walkway connection from the walkway along the north side of the drive aisle to the sidewalk/trail along Harmony Road. It should be designed similar to the walkway connection to the west that connects the sidewalk/trail to the hospital's main entrance. Also the crosswalk across the drive aisle should be designed similar to the crosswalk design to t he west (see red lines). Number: 24 Created: 4/21 /2004 [4/21/04] Please consider increasing the widths of the 6 foot attached walkways along the walkway spine through the parking lot to a minimum 7-foot width. Potential users of the walkways accessing the medical building could be. people in wheelchairs, in casts, using crutches, etc. and the extra width will increase their mobility since two feet of the walkway will be taken up by cars overhanging into the walkway. This would leave a minimum of a 5 foot clear space enough for two wheel chairs to pass each other. Number: 25 Created: 4/21 /2004 [4/21/041 Will the handicap parking stalls along the walkway spine be flush with the walk and landscaping? Or will there be a raised curb with access ramps every 9 feet? Page 3 J walkway. System modification charges will apply to any electric system that needs to be relocated. Number: 12 Created: 4/19/2004 [4/19/04] On the Landscape Plan show the electric vault located on the north side of the proposed building and remove landscaping from around the vault. Number: 13 Created: 4/19/2004 [4/19/04] Submit Commercial Service Information Form (C-1) with building load requirements. Number: 14 Created: 4/19/2004 [4/19/04] On the Utility Plan show where electric meter and CT cabinet will be located on the building and coordinate the transformer location with Light & Power. Department: PFA Issue Contact: Ron Gonzales Topic: fire Number: 32 Created: 4/26/2004 [4/26/04] A fire sprinkler system shall be required. Submit plans for review as required Number: 33 Created: 4/26/2004 [4/26/04] the building address shall be visible from the street on which it fronts, posted on a contrasting background, minimum 6 inch numerals Number: 34 Created: 4/26/2004 [4/26/04] a fire lane shall be provided, and platted as an emergency access easement. Please provide a fire lane plan for approval prior to installation. Number: 35 Created: 4/26/2004 [4/26/04] fire hydrants are required on 600-ft. centers down the fire lane, and one within 300 ft. of the building. Number: 36 Created: 4/26/2004 [4/26/04] hazardous materials for this office bldg.shall be disclosed to the PFA. Department: Police Issue Contact: Joseph Gerdom Topic: General Number: 16 Created: 4/20/2004 [4/20/04] Lighting levels at south end - drive/loading area - fall below required 1.Ofc. Ornamentals along north side of building may block surveillance of parking lot from building. Private/maintenance doors should have lighting and viewports. Department: Stormwater Utility Topic: Drainage Number: 28 Issue Contact: Wes Lamarque Created: 4/21 /2004 Page 2 6a � City of Fort Collins BHA DESIGN ANGIE MILEWSKI 4803 INNOVATION DR FT. COLLINS, CO 80525 Angie, STAFF PROJECT REVIEW Date:04/26/2004 Staff has reviewed your submittal for PVH HEALTH SYSTEMS, HARMONY CAMPUS, 4TH FILING, MEDICAL OFFICE BUILDING II PDP - TYPE I, and we offer the following comments: ISSUES: Department: Current Planning Issue Contact:. Cameron Gloss Topic: General Number: 21 Created: 4/21 /2004 [4/21/04] No information was provided regarding the proposed exterior building materials and colors. Please add to the building elevations a summary list of all building materials and the colors of each to ensure compatibility with the existing medical office building. Number: 22 Created: 4/21 /2004 [4/21/04] Please remove the word 'Preliminary" from the plat. Action taken by the Hearings Officer on this application is based on this document being the final version. Department: Engineering Issue Contact: Dave Stringer Topic: General Number: 15 Created: 4/20/2004 [4/20/04] No comments on this PDP submittal. Will have comments on Final Compliance Plan. Engineering okay for hearing Department: Light & Power Issue Contact: Alan Rutz Topic: General Number: 10 Created: 4/19/2004 [4/19/04] Underground electric lines on the Utility Plan and other plans are not shown in their correct location. Please locate and show the correct location of electric lines, vaults and transformers on the Utility Plan. Final comments or approval of the plans can not be made without this being corrected. Number: 11 Created: 4/19/2004 [4/19/04] There is an existing electric line under the proposed walkway connecting the two buildings. Please submit details of this part of building and its foundation. Include plan and profile details of the existing electric line and proposed building Page I