Loading...
HomeMy WebLinkAboutSAGE CREEK - PDP - 25-98B - CORRESPONDENCE - CITY STAFF (3)'' , .,A Page 2 Sage Creek PDP 12-22-99 I regret yet another delay in this project for hearing but we need additional information on a more complete set of utility plans prior to setting a hearing date. I understand this letter may create some concern on your part. However, I believe it is important for Engineering to relay to you, our position on why we can not recommend this project for a hearing at this time. Sincerely, David Stringer Development Review Manager Cc: Cam McNair, City Engineer Mark McCallum, Review Engineer Ron Fuchs, Project Planner Sear/Brown, Design Engineers Transpo 'ion Services Engineering Department City of Fort Collins December 22, 1999 Jim Postle 2919 Valmount Road Suite 109 Boulder, Co. 80301 RE: Utility Plan Submittal — Sage Creek PDP Dear Mr. Postle: The intent of this letter is to inform you of our disappointment in the quality of the latest submittal for your Sage Creek project here in Fort Collins. This project was submitted to the City around December 1, 1999, for its third round of review. In most cases, after three cycles of plan review and revision, project plans will meet the City's quality standards, and the project can then be scheduled before the City's Hearing Officer or the Planning and Zoning Board. However, based upon the lack of response to Engineerings previous comments and the omission of information that had been supplied on previous submittals, one or more rounds of review will be required before I can recommend this project for hearing. For your information I have enclosed copies of the City's development review engineer's latest comments for the Sage Creek utility plans submitted by Sear/Brown on December 1, 1999. The comments in bold print are those items that he has previously requested additional information about, with the remaining items being new comments to the last submittal. These new comments are a result of new information being provided or a lack of information from previous comments. Prior to the City accepting the next submittal I have advised our development review engineer, Mark McCallum, to quickly review the plans that are being resubmitted to determine if it is complete and that his comments have been addressed prior to the design engineering's resubmittal to the Planning Department. If not, he has been instructed to refuse the submittal until such time as his concerns have been met. As with all projects currently in the City review system, the design engineer has ninety (90) days to address our comments and resubmit revised plans to the Planning Department. Additionally, I have asked that Mark include in his comments the requirement that the design engineer must meet with him to go over these latest comments as soon as possible. 281 North College Avenue • P.O. Box 580 • Fort Collins, CO 80522-0580 • (970) 221-6605