Loading...
HomeMy WebLinkAboutLEVON'S 2ND PHASE, WAREHOUSE & OFFICE BUILDING - PDP/FDP - 19-96C - REPORTS - RECOMMENDATION/REPORTVICINITY MAP #19-96C Levons Warehouse /Office Type 1 - PDP (LUC) 03/08/00 1"= 600' Levon's 2nd Warehouse & Office Building P.D.P., File #19-96C June 21, 2001 Type 1 Hearing Page 6 The proposed plan therefore meets the requirements of this section. D. Transportation and Circulation [3.6] 1. Master Street Plan [3.6.1 ] —There are no arterial or collector streets identified on the Master Street Plan adjacent to this site. 2. Transportation Level of Service Requirements [3.6.4] — The Transportation Planning Department and the City Traffic Engineer have determined that the project meets the applicable Level of Service(LOS) requirements. 3. Transit Facilities Standards [3.6.5] — There is an existing Transfort route that goes down College Avenue. Employees and customers can utilize this existing system including the existing bus stops. FINDINGS OF FACT/CONCLUSIONS After reviewing the Levon's 2"d Warehouse & Office Building P.D.P., File #19-96C, staff makes the following findings of fact and conclusions: 1. The proposed land uses are permitted in the (CN) Commercial — North College zone district subject to type 1 review. 2. The Project Development Plan complies with all applicable district standards of Section 4.18 of the Land Use Code, the (CN) Commercial — North College zone district. 3. The Project Development Plan complies with all applicable General Development Standards contained in Article 3 of the Land Use Code except where the aforementioned modification has been granted. 4. The proposed plat complies with all applicable criteria in the Land Use Code. RECOMMENDATION: Staff recommends approval of the Levon's 2Id Warehouse & Office Building P.D.P., File #19-96C. Levon's 2nd Warehouse & Office Building P.D.P., File #19-96C June 21, 2001 Type 1 Hearing Page 5 4. Site Lighting — [3.2.4] — As required the applicant is using lighting fixtures that are concealed and fully shielded featuring sharp cut-off capability which reduces up -light, spill -light, glare and unnecessary diffusion on adjacent property. The proposed fixtures are wall mounted on the building wall itself. The PDP therefore satisfies this requirement. B. Engineering Standards [3.3] 1. Plat Standards [3.3.1 ] The plat has been reviewed against the criteria of the Plat Standards of the Land Use Code. The request to create a 3.34 acre lot complies with the following standards: • Lots [3.3.1(B)(1)] - The new lot has frontage along Hickory Street and Hemlock Street, both dedicated public right-of- ways. Vehicular access will be off of Hickory Street. Side lot lines are substantially at right angles or radial to the street line. The lot layout meets the City's street connectivity standards to the extent feasible. • Public Sites, Reservations, and Dedications [3.3.1(C)(1)] - The plat indicates proper dedications for drainage and utility easements as needed to serve the lot. 2. Water Hazards [3.3.3] — The PDP has been reviewed by and complies with the requirements of the Stormwater Department. 3. Engineering Design Standards [3.3.5] — This project complies with all design standards, requirements, and specifications for all of the commenting departments and agencies. C. Building Standards [3.5] 1. Building and Project Compatibility [3.5.1 ] —The proposed structure is compatible with the context of the surrounding area. 2. Mixed -Use, Institutional and Commercial Buildings [3.5.3] — The proposed building, satisfies the variation in massing, faqade treatment, entrance treatment, and the base and top treatment requirements, as required of any commercial building. Section 3.5.3(B)(2) of the Land Use Code requires that a minimum 15 foot build to line is established and that the build -to line is based on a consistent relationship of the building to the street sidewalk in order to form a visually continuous, pedestrian -oriented streetfront. The applicant granted a modification by the Planning and Zoning Board on June 1, 2000 to locate the new building 20 feet from the Hemlock right-of-way, and to have the front of the building face the interior of the site rather than the street (currently a gravel road). Levon's 2"a Warehouse & Office Building P.D.P., File #19-96C June 21, 2001 Type 1 Hearing Page 4 materials in conformance with city specifications. The project therefore complies with access and parking lot requirements. • Parking Lot Layout [3.2.2(E)] — The parking lot provides well- defined circulation routes for vehicles, bicycles and pedestrians. Landscaped peninsulas with raised curbs define parking lot entrances and the end of parking aisles. The proposed plan provides continuous, direct pedestrian access with a minimum of driveway and drive aisle crossings. No parking bays extend more than 10 spaces without an intervening landscape peninsula. This standard is satisfied. • Required Number of Spaces for Type of Use [3.2.2(K)] — The proposed building proposes office uses and warehouse uses in one building. Office uses are limited to a maximum of 3 parking space per 1000 square feet of leasable floor area, and warehouse uses are limited to .75 spaces per employee. The site plan depicts 15 parking spaces to be built, and identifies a potential future parking expansion area of another 18 spaces. Staff required the following note to be included on the site plan: "If not enough uses are located in this building to allow the total number of parking spaces proposed for phase 1 (15 spaces), a minor amendment will be filed to remove enough spaces to bring the site into compliance with the L.U.C. Conversely, if uses allow parking spaces to be added, spaces will be added as phase 2 parking, the number to be in accordance with 3.2.2(K)(2)(a) of the L. U.C. but not more than the 18 spaces indicated unless a minor amendment for the additional spaces is filed for and approved. " With the inclusion of the said note, the application satisfies this standard. • Handicap Parking - [3.2.2(K)(4)] — The applicant has provided two handicap spaces, therefore the application satisfies this requirement. • Parking Stall Dimensions - [3.2.2(L)] — The standard parking stalls are 9'xl 9', which satisfies this requirement. 3. Solar Access, Orientation, Shading [3.2.3] — The proposed plan is designed in a way that protects its roof's access to sunshine between 9am and 3pm on December 215t. The physical elements of the development plan are located and designed in a way that will not cast a shadow onto structures within the site or on adjacent property greater than allowed in this section of the code. Levon's 2"d Warehouse & Office Building P.D.P., File #19-96C June 21, 2001 Type 1 Hearing Page 3 only proposed a maximum of 10 of one species, therefore satisfies the minimum species diversity requirement. • Foundation Plantings [3.2.1(E)(2)(d)] —All exposed sections of building walls have planting beds of at least 5 feet in width along at least 50% of such facade. The landscape plan therefore satisfies the foundation plantings requirement. • Parking Lot Perimeter Landscaping [3.2.1(E)(4)] —The parking lot is screened from off -site views by plant material and building placement. The landscape plan therefore satisfies the parking lot perimeter landscaping requirement. • Parking Lot Interior Landscaping [3.2.1(E)(5)] — The parking lot area on the site plan is required to devote at least 6% of the area of the parking lot to landscaped areas. There is a large landscape island between the proposed parking and the existing parking area which greatly exceeds the 6% minimum area for landscaping requirement. • Screening [3.2.1(E)(6)] —Landscape, fencing, and building elements are placed to adequately screen areas of low visual interest and visually intrusive site elements including the outdoor storage area and the trash enclosure area. 2. Access, Circulation and Parking [3.2.2] • Safety Considerations [3.2.2(C)(1)] — Pedestrians are separated from vehicles and bicycles to the maximum extent feasible, thereby satisfying this requirement. • Curbcuts and Ramps [3.2.2(C)(2)] — Ramps are provided along the northern facade to give vehicular access to overhead garage doors, thereby satisfying this requirement. • Bicycle Facilities [3.2.2(C)(4)] — A bicycle rack is being provided adjacent to the new building, thereby satisfying this requirement. • Walkways [3.2.2(C)(5)] — A grade separated sidewalk directly connects the street sidewalk with the main entrance of the new building without requiring a pedestrian to cross a drive aisle or vehicle area, thereby satisfying this requirement. • Access and Parking Lot Requirements [3.2.2(D)] — Vehicle areas are clearly separated from walkway areas. Unobstructed vehicular access is provided from the public street to all parking spaces. All off-street parking areas are surfaced with Levon's 2nd Warehouse & Office Building P.D.P., File #19-96C June 21, 2001 Type 1 Hearing Page 2 annexed as part of North College Avenue Consolidated Annexation in December of 1959. 2. Division 4.18 of the Land Use Code. Commercial — North College District (CN) The proposed uses of "offices" and "warehouses" are both permitted uses in the (CN) Commercial — North College District subject to administrative review. The PDP meets the applicable Land Use Standards [4.18(D)] as follows: • This section of code limits the height of any building in this zone district to a maximum of 3 stories. The proposed building is a single story building, therefore this standard is satisfied. The PDP meets the applicable Development Standards [4.18(E)] as follows: • This section of code requires that all development in the CN zone district also comply with the standards contained in the Standards and Guidelines for the North College Avenue Corridor as adopted by the city, to the extent that such standards and guidelines apply to the property to be developed. This document deals with the treatment of development adjacent to North College Avenue. This site is not adjacent to North College Avenue, therefore this standard is satisfied. 3. Article 3 of the Land Use Code — General Development Standards The Project Development Plan complies with all applicable General Development Standards as follows: A. Site Planning and Design Standards [3.2] 1. Landscaping and Tree Protection [3.2.1] • Full Tree Stocking [3.2.1(D)(1)(c)] — Full tree stocking is required in all landscaped areas within 50 feet of any building along high use or high visibility sides. Full tree stocking is formal or informal groupings of trees planted at 30' to 40' spacing intervals for canopy shade trees, or at 20' to 30' spacing intervals for coniferous evergreens or ornamental trees. The proposed site plan satisfies this standard. • Street Trees [3.2.1(D)(2)] — Street trees are required at 30 to 40 foot spacing along adjacent streets. The applicant satisfies this standard. • Minimum Species Diversity [3.2.1(D)(3)] —Based on the total proposed number of new trees (33), the applicant would be allowed to have up to 33% of any one species (11), but has ITEM NO. MEETING DATE _0�( STAFF Citv of Fort Collins HEARING OFFICER STAFF REPORT PROJECT: Levon's 2"d Warehouse and Office Building Project Development Plan, File #19-96C OWNER/APPLICANT: Charles Maserlian Fort Collins Truck Sales 700 N. College Ave. Fort Collins, CO 80524 PROJECT DESCRIPTION: The applicant is proposing to develop a 20,000 square foot office/warehouse building on a 2.2 acre site located in the 300 block of West Hickory Street. The property is bounded by Hickory Street on the north, the Union Pacific Railroad track and right of way on the east, Hemlock Street on the south, and regional bicycle trail on the west. The property is located in the Commercial — North College (CN) zone district. RECOMMENDATION: Approval EXECUTIVE SUMMARY: The proposed land uses are permitted in the CN zone district subject to a type 1 review. The Project Development Plan complies with all applicable district standards of Section 4.18 of the Land Use Code, (CN) Commercial — North College zone district. The Project Development Plan complies with all applicable General Development Standards contained in Article 3 of the Land Use Code except where a modification was granted. COMMENTS: Backqround The surrounding zoning and land uses are as follows: N: LMN — Hickory Street, Hickory Mobile Home Park, Union Pacific Railroad right-of-way and tracks, CN — existing industrial uses, E: CN - Union Pacific Railroad right-of-way and tracks, vacant land, S: POL — Work Center for Roosevelt National Forest, Salyer Natural Area, W: CN — The city owned Hickory Trail, Rural residential property with horses, Industrial Uses. The property is south of Hickory Street, west of the Union Pacific Railroad right- of-way, north of Hemlock Street, and east of the Hickory trail. The property was COMMUNITY PLANNING AND ENVIRONMENTAL SERVICES 281 N. College Ave. P.O. Box 580 Fort Collins, CO 80522-0580 (970) 221-6750 PLANNING DEPARTMENT