HomeMy WebLinkAboutHARVEST PARK SUBDIVISION, 5TH FILING - REPLAT OF BLOCKS 3 & 4 - 25-98H - REPORTS - RECOMMENDATION/REPORTNo Text
Harvest Park Subdivision, 5th Filing, File #25-98H
October 1, 2003 Administrative Hearing
Page 5
B. The Harvest Park Subdivision, 51h Filing meets the plat requirements
located in Section 3.3.1 - Plat Standards located in the General
Development standards in Article 3 of the Land Use Code.
C. The Harvest Park Subdivision, 51h Filing satisfies the General
Development Standards of Article 3.
D. The Harvest Park Subdivision, 51h Filing satisfies the Zone District
Standards for the LMN — Low Density Mixed- Use Neighborhood Zone
District.
RECOMMENDATION:
Staff recommends approval of the Harvest Park Subdivision, 5th Filing, File #25-
98H.
Harvest Park Subdivision, 5" Filing, File #25-98H
October 1, 2003 Administrative Hearing
Page 4
D. Division 3.6, Transportation and Circulation
1. Master Street Plan [3.6.1 ] — Rock Creek Drive is identified as a
Collector on the Master Street Plan. There are two sections of Rock
Creek Drive that currently exist. The first is the portion of Rock Creek
Drive east of this site between Ziegler Road and Corbett Drive. The
second is a half block segment within the Stetson Creek neighborhood
that stubs the street to the Harvest Park PDP's western property
boundary. The build out of the approved Harvest Park PDP will
eventually connect these two segments of Rock Creek Drive. Initially,
the portion of Rock Creek Drive that stubs to the western edge of the
Harvest Park PDP was established by the Rock Creek Overall
Development Plan (ODP), which was approved by the Planning and
Zoning Board in November of 1993. The Harvest Park Project
Development Plan (PDP) was approved in January 2000.
2. Streets, Streetscapes, Alleys and Easements [3.6.2] — The
connections of the private drives with the public streets use the
applicable Larimer County Urban Area Street Standards as required.
The standard is therefore satisfied.
4. Article 4 — LMN Zone District Standards
The Harvest Park Subdivision, 5'h Filing contains a use (single family attached
dwellings) that is permitted in the LMN — Low Density Mixed -Use Neighborhood
Zoning District subject to Type 1 review. The approval of the Harvest Park
Subdivision, 5'h Filing would continue to allow the Harvest Park PDP to satisfy
the permitted use standards for the LMN — Low Density Mixed- Use
Neighborhood Zone District.
5. Findings of Fact/Conclusion:
A. The Harvest Park Subdivision, 5'h Filing contains a use that is permitted in
the LMN — Low Density Mixed -Use Neighborhood Zoning District subject
to Type 1 review.
Harvest Park Subdivision, 5th Filing, File #25-98H
October 1, 2003 Administrative Hearing
Page 3
Procedural Requirements, Division 2.2 - Common Development Review
Procedures for Development Applications, Subsection 2.2.10(A) Minor
Amendments, where it states that a minor amendment can increase or decrease
the number of dwelling units by up to one percent. The concurrent minor
amendment request increases the number of dwelling units by approximately
0.83%, and therefore, can be processed as a minor amendment. As required,
such minor amendments shall comply with the applicable standards contained in
Articles 3 and 4.
3. Article 3 - General Development Standards:
The project complies with all applicable General Development Standards as
follows:
A. Division 3.2, Site Planning and Design Standards
Transportation Impact Study [3.2.2(C)(8)] — In
accordance with the Institute of Transportation Engineers
Trip Generation Handbook, 6th Edition, 1997, there is no
traffic impact with the proposed change townhomes
generate fewer trips than do single-family detached
housing.
B. Division 3.3, Engineering Standards
Plat Standards [3.3.1 ] — As required, the general layout of the lots,
roads, driveways, utilities, drainage facilities, and other services within
the proposed development are designed in a way that enhances an
interconnected street system within and between neighborhoods.
Proper right-of-way has been dedicated for public streets, and
drainage easements, and utility easements have been provided as
needed to serve the area being platted.
2. Water Hazards [3.3.3] — The Stormwater Department has reviewed the
application and has indicated that the application satisfies the
requirements of this standard.
Harvest Park Subdivision, 51h Filing, File #25-98H
October 1, 2003 Administrative Hearing
Page 2
COMMENTS:
1. Background:
The zoning and land uses that surround the site are as follows:
N: RL; existing Harmony Park, existing Traut Elementary School, existing
single-family attached residential north of the school.
NW: RL; existing Preston Junior High School, existing Wild Wood Farm single
family neighborhood,
S: LMN; Rock Creek Drive, undeveloped portions of the Harvest Park PDP
development, Sage Creek development (under construction),
W: LMN; undeveloped portions of the Harvest Park PDP development,
RL; existing Stetson Creek and Timber Creek single-family residential
neighborhoods.
E: LMN; existing and under construction portions of the Harvest Park
development.
Concurrently to this plat application, the applicant requests a minor amendment
to amend the Harvest Park Project Development Plan (PDP). This includes
amending the site plan, landscape plan, and utility plans to reflect conversion of
36 single family detached home lots to 40 single-family attached home lots. The
total number of dwellings for the PDP is thereby amended from 481 units to 485
units. The site and landscape plans are thereby amended to reflect the change.
The utility plans have been amended to reflect changes to utilities, street design,
and drainage design.
This application specifically creates a new plat, now called "Harvest Park
Subdivision, 5th Filing", for the portion of the original "Harvest Park Subdivision"
specified as "block 3 and block 4." The plat reconfigures lot lines, and creates
an additional 4 lots within the original area of blocks 3 and 4. The new plat
creates a block 1 and a block 2 of Harvest Park Subdivision, 5th Filing.
The parcel was annexed in September 1998 as part of the Ruff Annexation.
2. Article 2 - Administration:
The request complies with the applicable requirements of the Land Use Code,
specifically the procedural requirements located in Division 2.1 - General
ITEM NO. 1 of 2
MEETING DATE 10/1/2003
igA STAFF Troy iones
Citv of Fort Collins HEARING OFFICER
STAFF REPORT
PROJECT: Harvest Park Subdivision, 51h Filing, File #25-98H
[Type I, Administrative Review]
APPLICANT: Terence Hoaglund
Vignette Studios
144 N. Mason Street, Suite 2
Fort Collins, CO 80524
OWNER: The Writer Corporation
6061 S. Willow Drive, Suite 232
Englewood, CO 80111
PROJECT DESCRIPTION:
The request is to replat Blocks 3 & 4 of the approved Harvest Park P.D.P. from
36 single family detached home lots to 40 single-family attached home lots
(townhomes). The project site is bounded by Harvest Park Lane on the north,
Old Mill Road on the west, Mill Stone Way on the east, and Rock Creek Drive on
the south. The property is in the LMN — Low Density Mixed -Use Neighborhood
Zone District.
RECOMMENDATION: Approval
EXECUTIVE SUMMARY:
The request proposes the use "single family attached dwellings," which is a
permitted use in the LMN — Low Density Mixed -Use Neighborhood Zoning
District subject to Type 1 review. The proposal meets the plat requirements
located in Section 3.3.1 - Plat Standards located in the General Development
standards in Article 3 of the Land Use Code. An approval of the proposed
project would continue to allow the Harvest Park PDP to satisfy the General
Development Standards of Article 3 and to satisfy the Zone District Standards for
the LMN — Low Density Mixed- Use Neighborhood Zone District.
COMMUNITY PLANNING AND ENVIRONMENTAL SERVICES 281 N. College Ave. P.O. Box580 Fort Collins, CO80522-0580 (970)221-6750
PLANNING DEPARTMENT