Loading...
HomeMy WebLinkAboutSINCLAIR REDEVELOPMENT PUD - PRELIMINARY & FINAL - 20-96 - SUBMITTAL DOCUMENTS - ROUND 1 - HAZMATSdispenser is hit or moved out of it's proper operating position; refueling areas are visible from cashier areas; station personnel can stop delivery with emergency dispenser controls located in the store; station personnel are trained to respond to these spills; materials are available to station personnel to contain the spill Sinclair Oil Corporation has operated the facility at 2600 South College Avenue in Fort Collins since the mid-1970's with an excellent history relative to this type of incident. Hazardous Materials Impact Analysis PUD Plan Submittal Redevelopment Proposal for Sinclair Station #05013 2600 South College Southeast corner College Avenue and Drake Road Fort Collins, Colorado June 24, 1996 Hazardous Materials and Quantities: There will be a maximum of 24,000 gallons of gasoline stored on site in three-8,000 gallon underground storage tanks. The single wall fiberglass tanks were installed in 1990 and the lines will be double wall construction. Incident and Mitigation Scenarios: The following are reasonable incident and mitigation scenarios (incident/equipment or method of mitigation)that may occur at this facility: • Tank Leak/tanks are equipped with automatic tank gauging with tank testing feature; monthly statistical inventory reconciliation based on daily data is used; and, non- corrosive fiberglass tank are installed • Line Leak/non-corrosive double wall lines are installed; mechanical line leak detectors (annual testing); monthly statistical inventory reconciliation based on daily data is used; and, the dispensers and sub -pumps are equipped with sumps to contain leaks from line fittings • Tank Overfill/the tanks are equipped with drop tube overfill prevention valve to stop the filling at 95% tank capacity; the tanks are equipped with automatic tank gauging to provide accurate fuel inventory levels; and, manual tank gauging is used at delivery to confirm available capacity • Surface spill during tank tilling/15 gallon spill containment catch basins are installed at tank fills (drain into tank); and, deliveries are continuously manned during tank filling • Spill during automobile refueling/refueling areas are visible from cashier areas; station personnel can stop delivery with emergency dispenser controls located in the store; station personnel are trained to respond to these spills; and, materials are available to station personnel to contain the spill • "Drive off" with hose in car during automobile refueling/refueling areas are visible from cashier areas; station personnel can stop delivery with emergency dispenser controls located in the store; station personnel are trained to respond to these spills; materials are available to station personnel to contain the spill; the individual fuel nozzles are equipped with a shear section to "break" to minimize damage to fuel hoses and dispensers; and, fuel hoses are equipped with "break -away" to minimize damage to fuel hoses and dispensers • Dispenser Damage ("hit" by car or "drive off" described above)/each fuel line to the dispenser is equipped with a "shear valve" to automatically stop fuel flow if the