Loading...
HomeMy WebLinkAboutTHE GREENS AT COLLINDALE PUD - FINAL - 8-96A - CORRESPONDENCE -This concludes Staff comments at this time. Additional comments may be forthcoming as the various departments and reviewing agencies (i.e., Stormwater, Natural Resources, etc.) continue to review this request. In order to stay on schedule for the October 28, 1996 Planning and Zoning Board hearing, please note the following deadlines: ********************************************************************************* Plan revisions (folded & not stapled) are due by 12:00 p.m. Wednesday, October 9, 1996. P.M.T.'s, 10 prints, and colored renderings are due Monday, October 21, 1996. ***No revisions or supporting documents will be accepted after revision date (10/9/96).*** NO REVISIONS WILL BE REVIEWED AFTER THE ABOVE DEADLINE. IF REVISIONS ARE NOT RECEIVED BY THIS DATE, THE ITEM WILL EITHER GO TO THE PLANNING AND ZONING BOARD WITH A STAFF RECOMMENDATION BASED ON THE ORIGINALLY SUBMITTED DOCUMENTS OR THE APPLICANT WILL HAVE THE OPTION OF CONTINUING THE ITEM TO THE NEXT MONTH' S BOARD AGENDA. If you should have any questions regarding these comments or if I could be of further assistance to you in any way, please do not hesitate to contact me at 221-6641. Sincerely, 8:: Mitchell Haas Project Planner encl. E. Cablevision: TCI of Fort Collins would like to see all side easements shown labeled as six (6) foot utility easements. F. Light and Power: See attached comments. G. Poudre Fire Authority: 1. Two (2) fire hydrants will be required at or near the entrances. 2. The two duplexes labeled GG where the seven buildings are located at the south end of the project are shown as fire sprinklered but DO meet Fire Department Access requirements and, thus, would not be required to be fire sprinklered. 3. All access roadways must be an all-weather driving surface capable of supporting fire apparatus. Surfaces may be asphalt, concrete, or compacted road base. Surface criteria may be obtained from the City or County Engineering Departments. 4. The private drive must be signed "Fire Lane No Parking." The twenty-eight (28') foot private drive must be signed to prevent parking on one side. H. US West: 1. The landscape plan still shows decks extending into the utility easement along the south property line. This conflict with use for utilities is unacceptable to U S West. 2. U S West requires a utility easement at the southwest corner of Lot 24 for access across the drainage easement into Lot 24. I. Police: 1. Please consider building address locations and visibility. Easily readable addresses enhance emergency response times significantly. J. Mapping and Drafting (plat -related comments): 1. Please show Lemay Avenue dedication - reception number. 2. The plat needs a vicinity map. 3. Please describe the control monuments. 4. The dedication statement does not call the plat a PUD; this must be done. 5. The document that vacates the r.o.w. in Lot 1 should be listed on this plat. 6. Please label Tract A as "utility, drainage, and public access easement." t, K. Please add the following note to the Plant Notes section: "Replacement of landscape elements needed due to utility development and/or maintenance will be at the developer's expense." ELEVATION COMMENTS - - - A. Please submit final elevation drawings. B. Please provide a fencing detail as well as a development I.D. sign detail. IV. - - - COMMENTS FROM OTHER REVIEWING DEPARTMENTS --- A. Engineering: 1. See attached comments. B. Parks: 1. Park fees will vary according to square footage of buildings, and will be assessed at the time of building permit issuance. 2. Jerry Brown came across some language that the developers at Southridge put into their sales contracts. We feel that similar language would be appropriate for this project, and would like to see it placed in the General Notes of the site plan. The language is as follows: It is hereby understood that the Greens at Collindale PUD is a separate entity from Collindale Golf Course and is in no way affiliated with membership of the golf course, which is presently owned and operated by the City of Fort Collins. The City hereby expressly disclaims any present or future liability arising from the above described property's proximity to said golf course and related golfing activities, and the homeowner accepts and assumes any and all risks for future damage or injury that homeowner or their guests on the above -described property may suffer on account of such proximity. According to the Title transfer agreement (judgement and decree) that was written up and signed when the property was sold to Landsource, the City must grant an easement for the sanitary sewer lines through the golf course property, provided Landsource or their successors "shall pay for the reasonable cost of such easement, shall construct all improvements and facilities within such easement according to the design specifications of the City of Fort Collins and shall further bear all costs of construction of said improvement, as well as all costs of restoration and repair of any City property damaged by said construction." This agreement will need to be worked out with Jerry Brown of the Parks and Recreation Department. C. Zoning: 1. Building envelopes are suggested over footprints on the site plan. This must be corrected. 2. Please place a bike rack on the site plan, perhaps near the perpendicular parking area(s). 3. The setbacks note on Land Use Breakdown should say "minimum unless otherwise noted. This to address situations such as the fact that it says 14' minimum from east property line, but it shows an I P setback for Lot 7. D. Building Inspection: 1. See attached comments. 3. Please remove general notes numbers 10, 11, and 12 altogether. These notes do not apply because these plans are the Final submittal. 4. Please add a note stipulating that "All private drives contain public access easements." 5. Please remove note #9 as note #1 covers the same information. By the way, "plat" is spelled with one "C' 6. The parking count in the Land Use Breakdown shows 29 on street stalls. I count just 25. Please double-check your count and, if necessary, correct it. H. - - - LANDSCAPE PLAN COMMENTS --- A. The landscape plan does not match the site plan. Please read note 916 and ensure that it is being adhered to. For instance, the decks on the south side of the structures on Lots 19-24 are shown to extend further to the south than they do on the site plan. On the landscape plan, these decks are shown to clearly encroach upon the easements. This will need to be adjusted. B. The deck on the east side of the structure on Lot 17 is shown to extend beyond the property line and into the detention pond. This must be corrected. C. The hammer -head turn -around between Lots 16 and 17 is shown to be in the detention pond. This situation will not work and must be corrected. D. Please label all trees along the south property line in a manner that will stipulate that they are to be trees with a minimum caliper of three inches (3"), in accordance with note #15. E. At the hammer -head turn -around between Lots 24 and 25 (along Lemay), please fill in the gaps between the shrubs in order to make this row of shrubs a continuous screen between Lemay and the turn -around. Also, please change these shrubs to a taller species than Scandia Juniper, such as Mugo Pine, Blue Star Juniper, Old Gold Juniper, Pfitzer Juniper, Pfitzer Compact Juniper, or similar. F. In a similar vein to comment "E" above, please screen the northwest corner of the three -car parking area adjacent to Lot 25. The parking area across the street from Lots 3 and 4 needs to be screed from the Lemay Avenue right-of-way with a continuous row of 3-4 foot tall evergreen shrubs. G. Please place as many service lines in the drives and driveways as possible. Also, please put the meter pits and curb stops on landscaped areas and maintain the minimum separation distances, as stipulated in note #14. H. The water line shown in front of Lots 1; 2, and 3 must be in the street. It is currently shown under the parkway strips. Please adjust this accordingly. I. Please revise note #10 to read as follows: "Any changes in plant locations and/or overall quantities required by site conditions during construction will be prohibited unless such changes have been reviewed and approved by the City of Fort Collins." J. Please remove note #11 altogether. It conflicts with note #10. Commui.-.y Planning and Environmental . .vices Current Planning City of Fort Collins September 20, 1996 Mr. Bob Sutter Architectural Horizons P.O. Box 271217 Fort Collins, CO 80527-1217 Dear Bob, Staff has reviewed your submittal for the Greens at Collindale P.U.D., Final (#8-96A) and offers the following comments: 1. - - - SITE PLAN COMMENTS - - - A. Plan Comments: Please make sure that no easements are encroached upon (anywhere on the plans), and that no portion of any structure extends beyond its designated building envelope. A few entry areas and decks appear to be encroaching upon easements; for instance, ► The patio/deck on the south side of the building on Lot 27 is encroaching upon the landscape easement; ► The courtyard/entry area on the west side of the building on Lot 24 encroaches upon a utility and drainage easement; ► The entryways/courtyards on the front sides of the building on Lots 9 and 10 appear to be encroaching upon the front lot utility and drainage easement; ► The deck on the east side of the building on Lot 17 appears to be encroaching upon the utility and drainage easement, and extending beyond the designated building envelope; ► Other areas that appear to be encroaching upon easements include the northwestern corner of the building on Lot 25; both entryway courtyards on the building on Lots 25 and 26; and, the entryway courtyards of the buildings on Lots 14, and 18-23. 2. Fort Collins Light and Power does not install streetlights on private streets. Please revise general note #8 accordingly. Also, to the extent possible, please indicate the proposed locations of all privately installed street lights. 281 North College Avenue • P.O. Box 580 • Fort Collins, CO 80522-0580 • (970) 221-6750 FAX (970) 221-6378 • TDD (970) 224-6002