HomeMy WebLinkAboutRAMADA LIMITED SUITES PUD - PRELIMINARY/FINAL - 16-96 - CORRESPONDENCE -12. A traffic impact study will be required. The traffic study should incorporate potential traffic from lots 3-5. It will be necessary to obtain an access easement from the owner of Lot 3 for the shared access. Sidewalks along Mason Street must be at least five feet in width and detached from the curb. For more information, regarding these comments, please contact Sheri Wamhoff at 221-6750. 13. The site is located in the McClellands/Mail Creek Drainage Basin. The Storm Drainage Fee in this basin is $3,717 per acre subject to the runoff coefficient reduction. A standard drainage and erosion control report is required, with the exception of the release rate of 0.5 cfs/acre. The Stormwater Utility would prefer for this site to drain to the existing storm sewer at Boardwalk and Mason; however, if this would be a hardship, the detained release may be allowed into the curb and gutter of Mason Street. There is an S.I.D. (Special Improvement District) payment due on this property for the storm sewer improvements. The fee due will be roughly equal to $2,751.47 per acre, plus the Handy -Whitman Utility Cost Index (see handout example done for lots 4 and 5). Drainage cannot flow into the railroad right-of-way without an easement; most sites along the railroad R.O.W. have been bringing the railroad drainage through their sites. The site may be next to an existing wetland; if so, any impacts to said wetland must be addressed/mitigated. For further information, please contact Glen Schlueter, 221-6589. 4. If a kitchen will be part of the proposal, the City's Water and Wastewater Department will require a grease interceptor on the sanitary sewer line. There is an eight (8") inch sanitary sewer line and an eight (8") inch water line which runs in/along Mason Street. There are existing stubs into the site; if these stubs are of adequate size, they must be utilized. On the other hand, if it is found that these stubs are not large enough to service the site and the proposed use, they will have to be abandoned. Taps into these lines are subject to specific spacing requirements, and fire water and domestic water taps must be separate. Water conservation standards for landscaping and irrigation will apply. Plant Investment and Water Acquisition Fees will be due at the time of building permit issuance. There may be repay agreements on taps into the water and sewer lines serving this site. For further information on water and sewer issues, please contact Roger Buffington, 221-6681. For further information on plant investment fees and raw water requirements, please contact Mary Young at Water and Wastewater Utility, 221-6681. 6. The property is zoned HB, Highway Business. As the proposed use is not specifically allowed in this zone, the project must be processed as a Planned Unit Development (P.U.D.), subject to the standards of the Land Development Guidance System (LDGS), for consideration by the Planning and Zoning Board. 7. It will be necessary to include bicycle racks as part of the site plan. These racks should be conveniently and safely located, permanently anchored to the ground, and should not obstruct any walkways. 8. The twenty -foot drive lane on the north side of the proposed building would have to be striped as a "Fire Lane" with no parking allowed. All turns must be designed such that there is a minimum of a twenty foot (20') radius on the inside of the turn and a forty (40') foot radius on the outside of the turn. The third story of the structure would have to be equipped with an automatic fire suppression system (sprinklers). The Poudre fire Authority would like there to be an addressable fire alarm system. It would be necessary to provide a fire hydrant at either side (north or south) of the Mason Street access. If you have any questions regarding the Poudre Fire Authority's requirements or comments, please contact Roger Frasco at 221-6570. 9. Please provide recycling facilities/opportunities within the trash enclosures. Trash enclosures must be visually screened from public view, as must all roof -top mechanical equipment. 10. It will be necessary to provide handicap accessible parking spaces. Handicap accessible routes of travel cannot have 'slopes exceeding ADA requirements. Similarly, a minimum of one out of every seven rooms/units will have to be handicap accessible. A 13-R system is allowable in guest rooms. For information regarding these comments, please contact Sharon Getz at 221-6760. 11. The proposed land uses will be assessed a Street Oversizing Fee of $14,005 per acre of developed land, payable at the time of building permit issuance. For further information on an estimate of these fees, please contact Matt Baker, 221-6605. IN CONCEPTUAL REVIEW STAFF COMMENTS MEETING DATE: April 29, 1996 ITEM: Ramada Suites Hotel on west side of Mason Street, at Boardwalk Drive (Lots 1 and 2 of Garth Subdivision). APPLICANT: Terence C. Hoaglund Cityscape Urban Design, Inc. 3555 Stanford Road, Suite 105, Fort Collins, CO 80525 LAND USE DATA: Request for a three-story, sixty-six room hotel on approximately 1.26 acres located on the west side of Mason Street at the intersection of Boardwalk Drive. The hotel would share access with the lot to the south (Lot 3). The roof of the building would be pitched and would have an average height of forty-two (42') feet with a peak height of forty-four (44') feet. The back/west side of the lot borders the Colorado and Southern Railroad right-of-way. COMMENTS: 1. Electrical power will be supplied by City of Fort Collins Light and Power Utility which has a conduit along/in Mason Street; all services must be underground. Underground installation must be placed within an easement meeting the specifications of the utility. Buildings must not encroach onto this easement. 2. The electrical transformer must be within eight feet of hard surface for emergency change -out. The transformer must not be located by or visible from the adjoining arterial street, Mason Street. The transformer must be screened by a solid enclosure meeting the clearance specifications of the Utility or by landscape materials. The location of the transformer will affect the development charges associated with the project. You will need to complete a commercial (C-1) loading form. Streetlight locations may need to be changed and, thus, will need to be coordinated. For further information regarding electrical service, please contact Doug Martine at 221-6700. 3. It was highly recommended that you make use of the lighting consultation services offered by the Light and Power Department. The Department will review your lighting needs, efficiency, design, and costs for no charge (free). For more information regarding this service, please contact Jon McHugh at 221-6700. COMMUNITY PLANNING & ENVIRONMENTAL SERVICES 281 NORTH COLLEGE P.O.BOX 580 FORT COLLINS, COLORADO80522-0580 (303)221-6750 PLANNING DEPARTMENT Comn ity Planning and Environment: ervices Current Planning City of Fort Collins April 29, 1996 Terence C. Hoaglund Cityscape Urban Design, Inc. 3555 Stanford Road, Suite 105 Fort Collins, CO 80525 Dear Mr. Hoaglund: For your information, attached is a copy of the Staffs comments concerning Ramada Suites Hotel on the west side of Mason at Boardwalk Drive (Lots 1 and 2 of Garth Subdivision presented before the Conceptual Review Team on April 29, 1996. The comments are offered informally by Staff to assist you in preparing the detailed components of the project application. Modifications and additions to these comments may be made at the time of formal review of this project. If you should have any questions regarding these comments or the next steps in the review process, please feel free to call me at 221-6750. Sincerely, Mitch Haas City Planner MH/gjd cc: Eric Bracke, Streets Department Stormwater Department Project Planner File 281 North College Avenue • P.O. Box 580 • Fort Collins, CO 80522-0580 • (970) 221-6750 FAX (970) 221-6378 • TDD (970) 224-6002