HomeMy WebLinkAboutLEVON'S WAREHOUSE/OFFICE - PDP - 19-96A - CORRESPONDENCE - (4)o. Please label the site plan, landscape plan, and elevations as sheets 1 of--. 3, 2 of 3, and 3 of 3. The plat should remain as sheet 1 of 1. p. Windows are required and should be defined with detail elements such as frames, sills and lintels, and placed to visually establish human scale and proportion [3.5.1(F)(3)(c)]. Be sure and return all your redlined plans when you resubmit. If you have any questions about these or any other issues related to this project please feel free to call me at 221-6750. Yo rs truly, Vv Troy Jones City Planner 6 k. Exposed sections of building walls that are in high -use or high - visibility areas of the building exterior shall have planting beds at least five feet wide placed directly along at least 50% of such walls [3.2.1(E)(2)(d)]. The northern fagode of this building is a high -use exterior wall, therefore this standard is not being satisfied. I. Industrial uses are limited to a maximum of 0.75 parking spaces per employee. Office uses are limited to 60 spaces for this building [3.2.2(K)(2)(a)]. Because of the speculative nature of the building, the number of spaces you provide will limit minimum number of industrial employees the building will be allowed to have. For example, if you build the parking lot with 15 parking spaces now, then any industrial use in the building must have at least 20 employees (20 employees x 0.75 = 15 spaces). If you build all 33 proposed parking spaces and an industrial use moves into the building, that use must have at least 44 employees (44 employees x 0.75 = 33 spaces). If an industrial user moves into the building and has fewer employees than needed to support the parking, the spaces will have to be removed. Failure to do so would result in a zoning violation which if enforced could result in a fine of up to $1000 per day until the violation is fixed. m. Be specific about which spaces you are building now, and don't mention spaces you are not building. If you need to build more spaces in the future, you can do it as a minor amendment. It is required that 6% of the interior area of the parking lot you are building now consist of landscaped areas. Each landscaped island within the parking lot shall include one canopy shade tree [3.2.1(E)(5)]. It appears that the paved area on the north side of the proposed building will have to have more landscaping in accordance with comments "g" and "k" above. Be sure that the new configuration of the paved area satisfies the requirement for 6% landscaped areas within the parking lot. Specify on the site or landscape plan the area of the parking lot and the area of the landscaped areas within the parking lot. Figure 1 on page 12 of Article 3 in the Land Use Code depicts what to include in the boundary of the parking lot area. n. The proposed "open storage area' must be screened from off -site views in the form of plantings, walls, fences (not chain -link) screen panels, topographic changes, or a combination of these techniques [3.2.1(E)(6)] & [3.5.1(J)(2)]. The view of the storage area from the east is not screened. 5 requirement. As shown, the proposed elevations do not satisfy this requirement. • If the building contains a commercial use, primary building entrances shall be clearly defined and recessed or framed by a sheltering element such as an awning, arcade or portico [3.5.3(0)(4)]. As shown, this standard is not being satisfied. • If the building contains a commercial use, all facades shall have a recognizable "base" and a recognizable "top" treatment [3.5.3(D)(6)]. The masonry base treatment as shown is acceptable except that one is not shown for the southern fagade. The top treatment must be more substantial than is currently shown. f. If the building is a warehouse and there is an office that serves the warehouse use, the building is industrial. If there is a business that is primarily office uses the building is commercial. g. "Full tree stocking" is required to be provided in formal or informal groupings spaced at 30 to 40 foot spacing intervals (for Canopy shade trees) or at 20 to 30 foot spacing intervals (for evergreens or ornamental trees) in all landscape areas within 50 feet of the building. Landscape areas shall also be provided inadequate numbers to allow full tree stocking to occur along high use or high visibility sides of any building. Such landscape areas shall extend at least 7 feet from any building wall and contain at least 55 square feet [3.2.1(D)(1)(c)]. Trees are required along the southern face of the building and landscape areas including trees are required along the northern face of the building to satisfy this standard. h. Canopy shade trees shall be planted in the adjoining street right-of- way in the center of the parkway strip between the curb and sidewalk or 3 to 7 feet behind an attached sidewalk at 30 to 40 foot spacing intervals [3.2.1(0)(2)]. The area south of the existing entry drive off Hickory Street and the frontage along Hemlock must have these street trees. i. No more than 50% of the 16 proposed trees can be of a single species [3.2.1(D)(3)]. There are 10 Ponderosa Pines proposed, therefore this standard is not being satisfied. j. Canopy shade trees must be planted with a minimum 2.0" caliper [3.2.1(D)(4)]. You propose 3 Ash trees and 3 Honey Locust trees that do not meet this standard. 4 If the building contains a commercial use, it must have a variation in massing. The building cannot be more than 3 times longer than it is tall without a substantial variation in massing that includes a change in height and projecting or recessed elements. Changes in mass shall be related to entrances, the integral structure and /or the organization of interior spaces and activities and not merely for cosmetic effect [3.5.3(C)]. As proposed the building does not satisfy this standard. • If the building contains a commercial use, it must have a minimum wall articulation that depicts building bays a maximum of 30 feet in width. Bays shall be visually established by architectural features such as columns, ribs, or pilasters, piers and fenestration pattern [3.5.3(0)(2)(a)]. As proposed the building does not satisfy this standard. • If the building contains a commercial use, any wall that faces a street or connecting walkway cannot have a blank uninterrupted length exceeding 30 feet without including two of the foIlowing:.change in plane, change in texture or masonry pattern, windows, treillage with vines, or and equivalent element that subdivides the wall into human scale pro port ions[3.5.3(b)(2)(a)(1)]. As proposed the building does not satisfy this standard. There are now windows even shown on the elevations. • If the building contains a commercial use, all sides of the building shall include materials and design characteristics consistent with those on the front. The use of inferior or lesser quality materials for side or rear facades shall be prohibited [3.5.3(1))(2)(a)(3)]. As shown the southern fagade does not have the masonry that is proposed on the other facades, and therefore is using lesser quality materials for the rear fagade. • If the building contains a commercial use, facades that face a street or connecting pedestrian frontage shall be subdivided and proportioned using features such as windows, entrances, arcades, arbors, awnings, treillage with vines, along no less than 50% of the fagade [3:5.3(D)(3)]. The north, west, and south facades must all satisfy this 3 b. The outdoor lighting plan is not necessary. All the information shown on this sheet can be depicted on the elevations and site plan. c. The site plan is shown at 1"=60'. The plan is a bit small and hard to read at this scale. Please change the scale of the drawing to 1"=30'. d. You have stated that the building is speculative, so you are not sure what the exact use will be. If the building is industrial (warehouse), there are different standards that apply than if the building is commercial (offices). Please refer to Sections 4.18(13)(2)(c) & 4.18(13)(3)(a) of the Land Use Code for a list of permitted "Commercial/Retail Uses," and please refer to Sections 4.18(B)(2)(d) & 4.18(13)(3)(b)for a list of permitted "Industrial Uses." e. In order to build any of the uses listed as a "commercial/retail use" the building must comply with the building standards contained in [3.5.3 Mixed -Use, Institutional and Commercial Buildings] of the Land Use Code including: • For commercial buildings, at least one main entrance of the building shall face and open directly onto a connecting walkway with pedestrian frontage [3.5.3(13)(1)]. A connecting walkway is defined in Article 5 of the LUC as "(1) any streeet sidewalk, or (2) any walkway that directly connects a L building entrance(s) to the street sidewalk, and connects other origins and destinations for pedestrians .... without requiring pedestrians to walk across parking lots or driveways, around buildings or follow parking lot outlines which are not aligned to a logical route. _As shown the building does not satisfy this requirement. • If the di riding contains a commercial -use, the building -shall be no more than 15 feet from the right-of-way of an adjoining street, and no vehicle use areas are allowed between the building faces and the street [3.5.3(B)(2)]. As l shown, the site plan does not satisfy this standard. This would seem to be a challenge for Hickory Street, but may be possible for Hemlock Street. Hemlock would most likely need to be the front fagade in this case. Please set up a meeting between you, Current Planning, and Engineering to coordinate this comment if you intend to satisfy it by using Hickory Street. It may require additional improvements to Hickory that otherwise would not have been required. �� City of Fort Collins Comma -v� Planning and Environmental F Current Planning STAFF REVIEW COMMENTS Charles Mesanlian 700 N. College Ave. Fort Collins, CO 80524 -vices April 12, 2000 Staff has reviewed your submittal for Levon's Warehouse Condominium, and we offer the following comments: COMMENTS: 1. Water and Sewer Utility Department, Stormwater, Engineering, Mapping/Drafting, Street Oversizing, Transportation Planning: a. Please see the attached redlines and comment sheets from these departments. 2. Poudre Fire Authority, Engineering Pavement, Zoning, Building Inspection: a. Please see the attached comment sheets from these departments. 3. Natural Resources, Public Service, AT&T Cable, Water Conservation, Park Planning, Traffic Operations, Light and Power, Transfort: a. These department have indicated that they have no comments. 4. Current Planning: a. Section 2.2.11 of the Land Use Code requires that an applicant submit revisions based on this letter within 90 days or the project application becomes null and void. Your response to the City's concerns is due by July 11, 2000. A 30 day extension to this deadline is available. All requests for an extension should be directed to the Current Planning Director. If remaining issues are those that do not require plan revisions, a status report verifying continuing efforts toward resolving the issues is required within the same timeline. 281 North College Avenue • P.O. Box 580 • Fort Collins, CO 80522-0580 • (970) 221-6750 • FAX (970) 416-2020