collectors or local streets at least every 1320' along arterial roads is
satisfied by the intersection of Constellation Drive and Trilby Road. The
internal private drives connect in two locations to Constellation Drive and
one location on Trilby Road thereby contributing to the connectivity to the
surrounding neighborhoods.
O. Transportation Level of Service Requirements (Section 3.6.4). A
Transportation Impact Study (TIS) was conducted. The Transportation
Department has determined that the project does in fact meet the
specified Level of Service Requirements for all modes of transportation to
and from the site.
DECISION
The Fort Collins Good Samaritan Village - Project Development Plan, #27-96B, is
approved by the Hearing Officer without conditions. This Decision is based on the
following findings and conclusions:
A. The PDP is consistent with the approved ODP.
B. The proposed land uses are permitted in the MMN zone district.
C. The Project Development Plan complies with all applicable district
standards of Section 4.5 of the Land Use Code, the MMN zone district,
except Section 4.5[D][1][a], where a modification was granted at the ODP
stage of the process.
D. The Project Development Plan complies with all applicable General
Development Standards contained in Article 3 of the Land Use Code.
DATED THIS 161h DAY OF FEBRUARY, 2001.
40
%Mk�=
Robert C. Wi ner, Hearing Officer
RC=57069.04\371396.01 6
interior parking lot space of each of these lots must be devoted to
landscaping. All four lots meet this requirement.
Solar Access, Orientation, Shading (Section 3.2.3). The Code requires
that 65% of single family and two family lots less than 15,000 square feet
must conform to the definition of "solar -oriented lot." The proposed layout
exceeds this requirement by providing 70%.
J. Site Lighting (Section 3.2.4). The maximum proposed level of on -site
lighting is 2.3 foot candles, and the maximum proposed lighting level 20
feet off -site is 0.08 foot candles. The PDP complies with the site lighting
requirements that limit the maximum on -site lighting levels to no more than
10 foot candles except for loading and unloading areas and limit the levels
measured 20 feet beyond the property line to a maximum of 0.1 foot
candle.
K. Building Standards (Section 3.5). The PDP satisfies the requirement that
the proposed buildings and uses are compatible when considered within
the context of the surrounding area. The duplex/triplex portion of the PDP
acts as a transition between the more intense use on the south end of the
PDP and the existing single family neighborhood to the north. As
required, the primary facades and entrances face adjacent streets or
connecting walkways without requiring all pedestrians to walk through
parking lots or cross driveways. The proposed stucco and synthetic stone
building materials are different yet compatible with those of the existing
Good Samaritan buildings, as well as the surrounding neighborhood.
Street facing garage doors must be recessed 4 feet behind either the front
facade of the living area, or a 6 foot by 8 foot covered porch; the proposed
duplex and triplex models meet this requirement.
L. Master Street Plan (Section 3.6.1). The Master Street Plan identifies
Trilby Road as a 2-lane minor arterial, and Constellation Drive as a local
street. The PDP recognizes these designations improve both roadways to
City standards including the dedication of the appropriate right -of- way
widths.
M. Streets, Streetscapes, Alleys and Easements (Section 3.6.2). Public
street right-of-way widths and streetscape design conforms to the "Design
and Construction Criteria, Standards and Specifications for Streets,
Streetscapes, Sidewalks, Alleys and Other Public Ways." The private
drives provide emergency access, therefore the applicant has dedicated
them as "emergency access easements."
N. Street Pattern and Connectivity Standards (Section 3.6.3). The
requirement for a potentially signalized full -movement intersection of
RCW\57069.04\371396.01 5
E. Access To A Park, Central Feature Or Gathering Place. The project
meets the requirement that 90% of the dwellings shall be located within '/4
mile of park, central feature or gathering place within or adjacent to the
development. The development provides a qualifying central
feature/gathering place, therefore 100% of the units are within the required
distance.
F. Block Requirements. Each MMN development shall be developed as a
series of complete blocks bounded by streets (public or private). The
proposed layout satisfies this requirement. All proposed blocks are
smaller than 7 acres, as required in the Code. At least 40% of each block
side consists of either building frontage, plazas or other functional open
space, as required by the Code.
G. Landscaping and Tree Protection (Section 3.2.1). The PDP provides
significant canopy shading to reduce glare and heat build-up. Visual
quality and continuity within and between developments are addressed by
provision of street trees along Constellation, Trilby, and the interior private
drives, parking lot islands, full tree stocking, foundation plantings, a full
landscaped open space area, and service area screening. All tree
planting standards of the LUC have been addressed.
H. Access, Circulation, and Parking (Section 3.2.2). The parking and
circulation system will accommodate the movement of vehicles, bicycles,
pedestrians and transit safely and conveniently throughout the site and to
and from surrounding areas. A transit stop is located off -site at the corner
of College and Trilby. On -demand transit is provided for residents by
Good Samaritan. Adequate curbcuts and ramps have been provided at
convenient, safe locations for the physically disabled, for bicyclists and for
people pushing strollers or carts. There are 4 bicycle racks provided,
each with a minimum capacity of 3 Bicycle parking spaces, or in other
words, at least 12 spaces are provided, which exceeds the required
number of spaces (5% of the 180 spaces provided for automobile parking
= 9 bicycle parking spaces). The racks will be located near the entrances
of the existing residential facility, the therapy center, the maintenance
building, and the employee entrance to the existing long term care facility.
The on -site pedestrian system provides directness, continuity and safety.
Driveway pedestrian crossings are adequately enhanced to ensure the
recognition of the pedestrian way. The vehicular use areas are safe,
convenient, and attractive for all modes of transportation that will use the
system, including cars, trucks, busses, bicycles, pedestrians, and
emergency vehicles. The PDP meets the number of spaces, handicap
parking and parking stall dimension requirements. Each of the four parking
lot areas have fewer than 100 spaces, therefore a minimum of 6% of the
RC=57069.04\371396.01 4
The hearing officer specifically noted that the majority of residents expressed
general acceptance of the proposed development and did not object to the
proposed use. A number of persons spoke favorably about the relationship
between the existing use and operation with the surrounding neighborhood.
2. Compliance with Zoning, the Overall Development Plan, and Articles 3 and
4 of the Code: The PDP generally complies with the District Standards
contained in Section 4.5 of the Land Use Code (the MMN — — Medium Density,
Mixed -Use Neighborhood zone district) and Article 3 of the Land Use Code (the
General Development Standards).
The ODP was approved on April 2, 1998 for a 13.89 acre mixed -use
development in the MMN district. The ODP is compliant with all applicable
sections of the LUC except Section 4.5[D][1][a]. Section 4.5[D][1][a] of the LUC
states, "the minimum residential density of any phase in a multiple -phase
development plan shall be seven (7) dwelling units per net acre of residential
land." The Planning and Zoning Board approved the modification to the ODP on
April 2, 1998 to allow a lower residential density of 5.74 dwelling units per acre
for Parcel C.
Specifically, the application is found to meet the following requirements of
Articles 3 and 4 of the Code:
A. Division 4.5 of the Land Use Code, MMN — Medium Density Mixed -Use
Neighborhood District. The proposed uses of two-family dwellings, multi-
family dwellings, and accessory buildings over 650 square feet (the
maintenance and service building) are permitted uses in the MMN district
subject to administrative review.
B. Density. The duplex/triplex component consists of a 6.27 acre area
devoted entirely to residential uses. The approved ODP specified that this
6.27 acre area have a minimum of 32 units and a maximum of 36 units.
33 units are being proposed. Because the applicant was granted a
modification to Section 4.5[D][1][a] (min. 7 d.u. / acre) at the ODP stage of
the process, the proposed density of 5.26 du/acre is adequate.
C. Mix of Housing Types. There are no minimum number of housing types
required for this site because the parcel is less than 16 acres. The parcel
does, however, provide two housing types (two-family dwellings, and
multi -family dwellings).
D. Lot Sizes And Dimensions. The proposed lot sizes and dimensions of lots
are varied as required by the Code.
RCW\57069.04\371396.01 3
PUBLIC HEARING: The Hearing Officer, presiding pursuant to the Fort Collins Land
Use Code (LUC), opened the hearing at approximately 4:30 p.m. on February 9, 2001 in
the conference room of the City of Fort Collins Planning Department located at 281
North College Avenue, Fort Collins, Colorado.
RECORD OF HEARING: The Hearing Officer accepted during the hearing the following
evidence: (1) Planning Department staff report: (2) application and supporting
documents submitted by the applicant and the applicant's agents; (3) documents
submitted during the hearing; (4) a sign-up sheet of persons attending the hearing and
citizens speaking in favor or against the application; and (5) a tape recording of
testimony providing during the hearing.
FINDINGS AND CONCLUSIONS
The evidence presented to the Hearing Officer established facts supporting the
following findings and conclusions:
Compatibility with Surrounding Uses: The proposed development as it is
designed and landscaped is found generally compatible with the following
surrounding zoning and land uses:
North: Unincorporated Larimer County, Skyview South 2nd filing residential
neighborhood
South: RL Trilby Road, Ridgewood Hills residential neighborhood, and
future convenience commercial center,
East: Unincorporated Larimer County, Constellation Drive, Skyview South
First Filing residential neighborhood
West: Unincorporated Larimer County, Fossil Crest Subdivision, First
Filing.
Testimony by residents residing adjacent to the property and within the
neighborhood raised issues of general compatibility. These issues included: (1)
reduction or impacts upon existing views; (2) lighting impacts from vehicles; (3)
noise impacts (especially from the maintenance area and central trash dumpster;
and (4) traffic impacts (volume and noise). In each instance, the applicant
demonstrated that these concerns were directly addressed by the design of the
development and that reasonable measures were employed to mitigate these
impacts. For example, exits from the development were located to divert or align
vehicular headlights away from primary residential structures and changes in
grade and landscaping were employed to reduce impacts of noise and lighting.
As for view corridors enjoyed by adjacent residents, these concerns were found
to have merit, but there exists no legal obligation for adjacent landowners to
protect against reduction of views. A reduction of view is likely as the result of
maturing landscaping.
RCW\57069.04\371396.01 2
City of Fort Collins
Commut , Planning and Environmental ; vices
Current Planning
CITY OF FORT COLLINS, COLORADO
ADMINISTRATIVE HEARING OFFICER
TYPE 1 ADMINISTRATIVE HEARING
FINDINGS, CONCLUSIONS, AND DECISION
HEARING OFFICER:
ADMINISTRATIVE HEARING DATE:
Robert Widner
February 9, 2G01
PROJECT NAME: Fort Collins Good Samaritan Village - Project Development Plan,
#27-96B (Type 1, Administrative Review in the Land Use Code)
APPLICANT/ Kim Lambrecht
OWNER: Landmark Engineering
3521 W. Eisenhower Blvd.
Loveland, CO 80537
The Evangelical Lutheran Good Samaritan Society
4800 W. 57th Street
Sioux Falls, SD 57106
PROJECT DESCRIPTION: This is a request for a Project Development Plan to build
33 duplex/triplex residential units, a 2,400 square foot maintenance building, and a 0.6
acre civic purpose landscaped area. The property is zoned MMN — Medium Density,
Mixed -Use Neighborhood. This PDP is the first phase of development within the area
approved as the Fort Collins Good Samaritan Village ODP.
SUMMARY OF HEARING OFFICER DECISION: Approval without conditions
BACKGROUND AND ZONE DISTRICT: The property was annexed in January 1997
as the Fort Collins Good Samaritan Village Annexation. The property is zoned within
the MMN zoning district.
NOTICE OF PUBLIC HEARING AND NEIGHBORHOOD MEETING: Testimony or
evidence established that the property was properly posted, legal notice mailed, and
notice published. There was no requirement for a neighborhood meeting.