HomeMy WebLinkAboutSPRING CREEK STATION (2105 S. COLLEGE AVE.) - PDP - PDP160020 - CORRESPONDENCE - (3)Topic: Plat Comment Number: 8 Comment Originated: 07/19/2016 09/01/2016: The response to this comment is not sufficient. Since the location of the waterline is not centered in the easement and since it's not clear how wide the easement is, a new one will need to be dedicated with this plat. 07/19/2016: Please dedicate a utility easement for the existing waterline. The easement should be 10' on either side of the waterline, approximately 206 in width through the parcel included in this plat. Topic: Site Plan Comment Number: 10 Comment Originated: 07/19/2016 07/19/2016: Site Plan — There are several existing easements shown on the site plan that don't quite seem to match the easements shown on the plat. Please reconcile. 15 Department: Water Conservation Contact: Eric Olson, 970-221-6704, eolson@fcgov.com Topic: General Comment Number: 1 Comment Originated: 07/25/2016 07/25/2016: Irrigation plans are required no later than at the time of building permit. The irrigation plans must comply with the provisions outlined in Section 3.2.1(J) of the Land Use Code. Direct questions concerning irrigation requirements to Eric Olson, at 221-6704 or eolson@fcgov.com Department: Water -Wastewater Engineering Contact: Heather McDowell, 970-224-6065, hmcdowell@fcgov.com Topic: Construction Drawings Comment Number: 2 Comment Originated: 07/19/2016 07/19/2016: The Utility Department recommends conducting a fire flow test, during the course of design, on the existing 6" waterline that this site is proposing to tap into to verify that adequate fire flows are available in this location. If there are not adequate fire flows at this location, this project will be responsible to upsize the main to the extents required to achieve required fire flows. Comment Number: 3 Comment Originated: 07/19/2016 09/01/2016: Per the City standard detail 17-13, water meters cannot be placed in streets, alleys, parking areas, driveway, etc. Please relocate the proposed meter location. Also, now that you've adjusted the location of the water and fire services, the taps are in a location that is technically offsite of your property. Therefore, a Letter of Intent will be required to be submitted to the City, prior to P&Z from the adjacent property owner that shows that they acknowledge that you will need to do work on their property and will get a formal easement from them to do this work prior to construction. 07/19/2016: The proposed water meter will need to be placed outside of that easement. (It cannot be built this close to the water main. It should be at least 10' away from the main.) These plans will also need to show and callout the curb stop. Comment Number: 6 Comment Originated: 07/19/2016 09/01/2016: Please note that it appears as though at least one of the buildings gets its sanitary sewer service from a manhole that is quite a ways offsite, so the extents of your limits of disturbance may be more than you currently anticipate and you may need permission to enter adjacent property to do demolition work if an easement doesn't already exist. 07/19/2016: The existing sewer and water services to the existing buildings will need to be identified and shown on a demo plan. The demo plan should then clearly show which services will need to be removed and abandoned at the main. 14 Topic: Site Plan Comment Number: 13 Comment Originated: 07/25/2016 09/07/2016: The property boundary needs to match the Subdivision Plat. If you choose to keep the current boundary information on the plans, they must be shown as record bearings & distances per the document they are referencing. 07/25/2016: The bearings & distances on the property boundary should match the Subdivision Plat. Comment Number: 14 Comment Originated: 07/25/2016 09/07/2016: There are still some rights of way not shown that are on the Plat. Please show all with correct labels, or remove them all. 07/25/2016: Some of the right of way descriptions shown are incorrect. If they are going to stay on the plan, they should match what is shown on the Subdivision Plat. Comment Number: 15 Comment Originated: 07/25/2016 09/07/2016: There are still some easements not shown that are on the Plat. Please show all with correct labels, or remove them all. 07/25/2016: Some of the easement descriptions shown are incorrect. If they are going to stay on the plan, they should match what is shown on the Subdivision Plat. Comment Number: 33 Comment Originated: 09/07/2016 09/07/2016: Please remove "Bankcenter Square Second Filing" from the sub -title of all sheets. See redlines. Comment Number: 34 Comment Originated: 09/07/2016 09/07/2016: Please change the legal description to "Lot 1, Spring Creek Place". See redlines. Department: Traffic Operation Contact: Nicole Hahn, 970-221-6820, nhahn@fcgov.com Topic: General Comment Number: 2 Comment Originated: 08/02/2016 08/02/2016: We will have to work with you as you develop your landscape plans to ensure there is good sight distance at the entry to the garage. The opposing off set through traffic adds some complexity to this movement, and we want to make this area as visible as possible. Topic: Traffic Impact Study Comment Number: 1 Comment Originated: 08/02/2016 08/02/2016: The Fort Collins multimodal transportation level of service was not addressed in the study. This can be found in Appendix H in LCUASS. An addendum memo with a narrative related to the multimodal LOS can be submitted as a supplement to the traffic study. 13 Topic: General Comment Number: 38 Comment Originated: 09/07/2016 09/07/2016: SHADOW STUDY: Please remove "Bankcenter Square Second Filing" from the sub -title of all sheets. See redlines. Topic: Landscape Plans Comment Number: 35 Comment Originated: 09/07/2016 09/07/2016: Please remove 'Bankcenter Square Second Filing" from the sub -title of all sheets. See redlines. Topic: Lighting Plan Comment Number: 39 Comment Originated: 09/07/2016 09/07/2016: Please remove "Bankcenter Square Second Filing" from the sub -title of all sheets. See redlines. Topic: Plat Comment Number: 1 Comment Originated: 07/25/2016 09/06/2016: Please change the name to "Spring Creek Place", now that all other plans have changed. 07/25/2016: We would prefer that the name be "Spring Creek Station" to match the other plans. Comment Number: 8 Comment Originated: 07/25/2016 09/06/2016: All of the off -site easements that are marked are not necessary to show, but if they stay on the label needs to state who the easement benefits. See redlines. 07/25/2016: If you choose to keep existing off -site easements on the plat, you need to label what they are. See redlines. Comment Number: 10 Comment Originated: 07/25/2016 09/06/2016: These were not received. 07/25/2016: Please provide current acceptable monument records for the aliquot corners shown. These should be emailed directly to Jeff at jcounty@fcgov.com Comment Number: 29 Comment Originated: 09/06/2016 09/06/2016: Please label all surrounding properties with "Unplatted" or the subdivision name. This includes properties across right of ways. See redlines. Comment Number: 30 Comment Originated: 09/06/2016 09/06/2016: Please label "to whom" the easements are dedicated. See redlines. Comment Number: 31 Comment Originated: 09/06/2016 09/06/2016: Please clarify the dimensioning along the east line of the property. See redlines. Comment Number: 32 Comment Originated: 09/07/2016 09/07/2016: The west, south & east lines do not show measured bearings & distances. We think these should be labeled with an M&R. Please explain what is going on with these lines. 12 Topic: Construction Drawings Comment Number: 24 Comment Originated: 07/25/2016 09/07/2016: The benchmark referenced is not in our vertical control network, or one that we are familiar with. Please use a benchmark that is in our network. 07/25/2016: The City has moved to the NAVD88 vertical datum, and as of January 1, 2015, all projects are required to be on NAVD88 datum. Please provide the following information for the Benchmark Statement in the EXACT format shown below. PROJECT DATUM: NAVD88 BENCHMARK # w/ DESCRIPTION ELEVATION: BENCHMARK # w/ DESCRIPTION ELEVATION: PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88 - X.XX. Comment Number: 25 Comment Originated: 07/25/2016 09/07/2016: The Basis Of Bearings & property boundary needs to match the Subdivision Plat. If you choose to keep the current Basis Of Bearings & boundary information on the plans, they must be shown as record bearings & distances per the document they are referencing. 07/25/2016: The Basis Of Bearings statement should match the Subdivision Plat. Comment Number: 27 Comment Originated: 07/25/2016 09/07/2016: There are still some rights of way not shown that are on the Plat. Please show all with correct labels, or remove them all. 07/25/2016: Some of the right of way descriptions shown are incorrect. If they are going to stay on the plan, they should match what is shown on the Subdivision Plat. Comment Number: 28 Comment Originated: 07/25/2016 09/07/2016: There are still some easements not shown that are on the Plat. Please show all with correct labels, or remove them all. 07/25/2016: Some of the easement descriptions shown are incorrect. If they are going to stay on the plan, they should match what is shown on the Subdivision Plat. Comment Number: 40 Comment Originated: 09/07/2016 09/07/2016: Please remove "Bankcenter Square Second Filing" from the sub -title of all sheets. See redlines. Comment Number: 41 Comment Originated: 09/07/2016 09/07/2016: There are spelling issues. See redlines. 11 Topic: Drainage Reps. Comment Number: 13 Comment Originated: 09/01/2016: The LID -Detention spreadsheet utilizes Denver region rainfall data and results in a detention volume that is smaller than what is required using Fort Collins rainfall data. Please revise. 07/19/2016: Appendix B. The UD-Detention spreadsheet cannot be used to calculate detention volumes in the City of Fort Collins because it utilizes Denver rainfall data. Please build your own mass balance spreadsheet using the Modified FAA Procedure as outlined in the Fort Collins Stormwater Criteria Manual, Volume 2, Chapter 10, Section 3.2.3. Comment Number: 18 Comment Originated: 09/01/2016: Water Quality Requirements — This submittal looks to capture a much larger area of the site into the underground detention vault that also serves as your LID on this site than was previously shown. This is great. However, there is still approximately 15% of the site that isn't treated by any water quality device at all. I understand your challenges related to tying into existing roadways and adjacent properties but 15% is larger than I anticipated that wouldn't be captured. That said, I would also like for you to look at putting in an inlet on the east side of the drive aisle that runs north -south along the eastern side of the site to capture some of that area that drains off to the east. Comment Number: 19 07/19/2016 09/01/2016 Comment Originated: 09/09/2016 09/09/2016: Drainage Report — Please note that for the Stormtech system, the City of Fort Collins requires that the isolator row needs be sized for the WQCV amount. This is different than what Stormtech will tell you is necessary, but we require it because of concerns about long term infiltration rates. Please ensure that this volume is accounted for in the chambers you have shown or provide the additional chambers needed if the volume is not accounted for. Department: Technical Services Contact: Jeff County, 970-221-6588, icounty@fcgov.com Topic: Building Elevations Comment Number: 19 09/07/2016: There are line over text issues. See redlines. 07/25/2016: There are line over text issues. See redlines. Comment Number: 36 Comment Originated: 07/25/2016 Comment Originated: 09/07/2016 09/07/2016: There is text that needs to be masked. Mask all text in hatched areas. See redlines. Comment Number: 37 Comment Originated: 09/07/2016 09/07/2016: Please remove "Bankcenter Square Second Filing" from the sub -title of all sheets. See redlines. m encouraged to funs,-, consider upgrades and embellishments alu„g this walkway. The length of the walk is 364 feet. South of the walkway will be the Whole Foods parking lot. On the landscaping side of the walkway, to complement the landscaping, please consider adding a combination of raised planters and seat walls to the landscaping in a variety of configurations and heights to avoid repetition and monotony. On the building side, please consider adding more trim and detail to the garage openings and doorways. Recessing the garage openings to the maximum extent would accentuate the sills. Giving the doorways more of an entryway or foyer would add interest. Also, please consider creative lighting that could be combined with doorways, landscaping and garage openings. Comment Number: 25 Comment Originated: 09/07/2016 09/07/2016: Referring back to first round comment number 15 regarding showing the recesses and projections, thank you for the graphic depicting the extent of the modulation along the north and south elevations as well as the roof lines. Staff remains concerned, however, that the modulation consists only of the balcony module, which, by itself adds a measure of articulation. Staff finds that the balcony module is repeated a bit excessively and that these two long facades would benefit from additional wall plane articulation. The repeated horizontal module creates a ribbon effect and perhaps could be could be broken up with a more vertical element that offers a slight contrast to the sole reliance on the balcony modulation. Again, a building step back would accomplish this but lacking that, other techniques to achieve wall plane variety should be explored. Comment Number: 26 Comment Originated: 09/07/2016 09/07/2016: On the west elevation, the architectural elevations indicate that there are to be screen walls in front of the mesh screens of the parking garage. Please indicate the height of the screen wall. Is the landscaping shown to be planted on top of the screen wall? I'm not seeing how the screen wall and landscaping are integrated. Perhaps a detail would help. Department: Stormwater Engineering Contact: Basil Harridan, 970-224-6035, bhamdan@fcgov.com Topic: Erosion Control Comment Number: 17 Comment Originated: 08/01/2016 08/01/2016: No Erosion Control Plans or Report were submitted as part of this original submittal. These will need to be provided and ESC issues should be addressed at an FDP level submittal. Contact: Heather McDowell, 970-224-6065, hmcdowell@fcgov.com Topic: Construction Drawings Comment Number: 3 Comment Originated: 07/19/2016 09/01/2016: Please note, the bldg foundation and wall section will need to be included in the detail at Final design. 07/19/2016: Grading Plan. The sidewalk along the south side of the building looks like its elevated higher than the finished floor of the building. With the Final Utility Plans, please provide a detail and/or cross-section of this. E Comment Number: 14 Comment Originated: 08/03/2016 08/03/2016: Section 3.10.5(F)(3) requires that buildings in the Transit -Oriented Development Overlay Zone (T.O.D.) that are greater than two stories must be designed so that upper portions of the building are stepped back from the base. The adequacy of the upper floor step -backs will be evaluated by the extent to which they advance objectives related to providing a pedestrian scale along sidewalks, enhancing compatibility with the scale and massing of nearby buildings, preserving sunshine patterns in adjacent spaces and preserving views. It appears that the upper floors are not stepped back. Staff is mostly concerned about the pedestrian experience along the south elevation and the relationship between the treatment along the garage and the ten foot wide sidewalk. The pedestrian scale and experience walking along the screen walls for the garage needs to be considered in the architectural design of the south elevation. Carried Over: See below. Comment Number: 15 Comment Originated: 08/03/2016 08/03/2016: On the architectural elevations, we need to be able to evaluate the extent of the recesses and projections of the building modules. While the perspective renderings are helpful, no dimensions are provided. Please include a plan view line, with dimensions, that describes the variation in the massing of the building at the ground level that corresponds to the architectural elevation. Carried Over: See below. Comment Number: 18 Comment Originated: 08/03/2016 08/03/2016: There are a series of windows on the ends of the east and west elevation that appear flat in relationship to the fagade. The overall articulation of the building would be improved if these windows were upgraded with additional trim, or sills or lintels. Comment Number: 19 Comment Originated: 08/03/2016 08/03/2016: The person doors on the north, south and west elevations are not very well demarcated on the elevations. They appear as simple recesses without any other components that benefit the overall articulation. Please consider highlighting these person doors with additional features so that the ground floor of the building continues to contribute to the pedestrian scale. Carried Over: See below: Comment Number: 24 Comment Originated: 09/07/2016 09/07/2016: Referring back to first round comment number 14 regarding no upper floor building step backs, staff remains concerned that the revisions that enhance the south walkway may not be sufficient to address the central issue of mitigating the overall building mass and creating a sensible pedestrian scale. Based on the revised plans, staff is assuming that upper floor building step backs will likely not be considered. As mitigation, therefore, the applicant is Comment Number. 3 L,umment Originated: 07/08/2016 07/08/2016: FIRE LANE CONNECTION TO THE MAX TRANSIT LINE > The proposed fire lane connection to the Max Transit line will have to be approved by the City Transportation Department and Poudre Fire Authority. Currently, the connection point is undersized at approximately 8'. Any gate design less than 20' width will require approval by the fire marshal, but shall be no less than 16' wide. Turning radii may need to be adjusted so as to allow full vehicle movement. > In addition, the connection will require an approved electric, functioning gate for emergency access only. The opening mechanism should comply with existing Max corridor access standards although an Opticon function may also be warranted. Further discussion will be needed. Comment Number: 6 Comment Originated: 09/07/2016 09/07/2016: FIRE LANE SIGNS The limits of the fire lane shall be fully defined. Fire lane sign locations should be indicated on future plan sets however the applicant should understand that additional signage may be required at time of inspection and final CO. Code language provided below. > IFC D103.6: Where required by the fire code official, fire apparatus access roads shall be marked with permanent NO PARKING - FIRE LANE signs complying with Figure D103.6. Signs shall have a minimum dimension of 12 inches wide by 18 inches high and have red letters on a white reflective background. Signs shall be posted on one or both sides of the fire apparatus road as required by Section D103.6.1 or D103.6.2. Comment Number: 7 Comment Originated: 09/08/2016 09/08/2016: LANDSCAPING The landscape plan appears to create a tree location conflict with the proposed hydrant location on the building's east side. T of clear space is required around any hydrant, now and at time of landscape maturity. Code language provided below. > IFC 507.5.5: CLEAR SPACE AROUND HYDRANTS - A 3-foot clear space shall be maintained around the circumference of fire hydrants except as otherwise required or approved. Department: Planning Services Contact: Ted Shepard, 970-221-6343, tshepard@fcgov.com Topic: General Comment Number: 8 Comment Originated: 08/03/2016 08/03/2016: Standard notes will be provided to be added to the Site Plan. Carried Over: For note number 12, please add ...to concrete and not interfere with walkways or landscaping. KA Comment Number: 2 Comment Originated: 07/29/2016 07/29/2016: Electric Capacity Fee, Building Site charges and any system modification charges necessary will apply to this project. Comment Number: 3 Comment Originated: 07/29/2016 07/29/2016: Contact Light and Power Engineering to coordinate the transformer and electric meter locations, please show the locations on the utility plans. 'Please note that minimum clearances around transformers are 3' around the back and sides and 8' clearance from the front.*'* Comment Number: 4 Comment Originated: 07/29/2016 07/29/2016: Multi -family buildings are treated as commercial services; therefore a(C-1) form must be filled out and submitted to Light & Power Engineering. All secondary electric service work is the responsibility of the developer and their electrical consultant or contractor. Please provide a one line diagram and a C-1 form to Light and Power Engineering. The C-1 form can be found at: http://zeus.fcgov.com/utils-procedures/files/EngWikiMikiPdfs/C/C-1 Form.pdf Comment Number: 5 Comment Originated: 07/29/2016 07/29/2016: You may contact FCU Light & Power, project engineering if you have questions. (970) 221-6700. Please also reference our Electric Services Standards (ESS) document at the following link. http://www.fcgov.com/utilities/img/site_specific/uploads/ElectricServiceStandar ds_FINAL_17June2016.pdf Comment Number: 6 Comment Originated: 07/29/2016 07/29/2016: Please contact Light & Power Engineering if you have any questions at 221-6700. Please reference our policies, development charge processes, and use our fee estimator at http://www.fcgov.com/utilities/business/bu ilders-and-developers. Comment Number: 7 Comment Originated: 09/06/2016 09/06/2016: The storage unit and cell tower properties to the north of this project will likely need to be re -fed from a different direction and possibly with their own dedicated transformer. System modification charges will apply and it will likely be necessary that this project dedicates a new utility easement for that effort. Department: PFA Contact: Jim Lynxwiler, 970-416-2869, jlynxwiler@poudre-fire.org Topic: General Comment Number: 2 Comment Originated: 07/08/2016 07/08/2016: EMERGENCY ACCESS EASEMENT The limits of the fire lane shall be fully labeled on the plat and shown on the plans as an Emergency Access Easement (EAE). 0 pre -submittal meet.,..j. Applicants should be prepared to presern .,,,e plans, floor plans, and elevations and be able to discuss code issues of occupancy, square footage and type of construction being proposed. Comment Number: 2 Comment Originated: 07/22/2016 07/22/2016: Adoption of the 2015 I -Codes is anticipated for January 2017. Be advised that permit applications submitted after the code adoption date will be subject to the new codes and standards, as amended. For more information, contact Sarah Carter, Plans Examiner at 970-416-2748 or scarter@fcgov.com. Comment Number: 3 Comment Originated: 07/22/2016 07/22/2016: Construction shall comply with adopted codes as amended. Current adopted codes are: 2012 International Building Code (IBC) 2012 International Residential Code (IRC) 2012 International Energy Conservation Code (IECC) 2012 International Mechanical Code (IMC) 2012 International Fuel Gas Code (IFGC) 2012 International Plumbing Code (IPC) as amended by the State of Colorado 2014 National Electrical Code (NEC) as amended by the State of Colorado Fort Collins has amendments to most of the codes listed above. See the fcgov.com/building web page to view them. Accessibility: State Law CRS 9-5 & ICC/ANSI A117.1-2009. Snow Load Live Load: 30 PSF / Ground Snow Load 30 PSF. Frost Depth: 30 inches. Wind Load: 100- MPH 3 Second Gust Exposure B. Seismic Design: Category B. Climate Zone: Zone 5 Energy Code Use 1. Single Family; Duplex; Townhomes: 2012 IRC Chapter 11 or 2012 IECC. 2. Multi -family and Condominiums 3 stories max: 2012 IECC residential chapter. 3. Commercial and Multi -family 4 stories and taller: 2012 IECC commercial chapter. Comment Number: 4 Comment Originated: 07/22/2016 07/22/2016: City of Fort Collins IBC amendments require a full NFPA-13 sprinkler system in multifamily units with an exception for buildings with up to 6 dwelling units that are not more than 2 stories nor more 5000 sq.ft. per floor. Comment Number: 5 Comment Originated: 07/22/2016 07/22/2016: Building code and State statute CRS 9-5 requires project provide accessible units. This project has 72 units and will need to achieve at least 36 points. Department: Light And Power Contact: Coy Althoff, , CAlthoff@fcgov.com Topic: General Comment Number: 1 Comment Originated: 07/29/2016 07/29/2016: Both single phase & 3-phase power facilities are running along the south and the west side of the property lines. 5 Department: Forestry Contact: Tim Buchanan, 970-221-6361, tbuchanan@fcgov.com Topic: Landscape Plans Comment Number: 1 Comment Originated: 07/29/2016 09/07/2016: Continued: Thank you for arranging the on -site meeting. Tree inventory and mitigation information provide by the City Forester needs to be incorporated on the plan. Provide the required number of upsized mitigation trees that meet the following sizes. Canopy Shade trees 3.0 inch caliper Ornamental trees 2.5 inch caliper Evergreen trees 8 feet height 07/29/2016: Contact the City Forester for an on -site meeting to conduct an existing tree inventory and receive information for a tree mitigation plan. This information will need to be placed on the landscape plan. Existing trees will need to be identified by species, size , condition and the mitigation requirement. Comment Number: 3 Comment Originated: 07/29/2016 09/07/2016: Continued: Skymaster English Oak is used on the plan for a substitution for the crabapple trees. This cultivar has been taken out of production so availability is uncertain. Consider using another species in this location such as Bur Oak. 07/29/2016: Along the south perimeter planting use canopy shade trees in place of the 6 Radiant Crab. Comment Number: 5 Comment Originated: 09/07/2016 09/07/2016: Species Selection: The October Glory Red maple is not adapted to the soils in Fort Collins and does not survive or thrive long term. Substitute it with another canopy shade tree. Suggested substitution trees: Bur Oak Chinkapin oak Catalpa This information was also provided to the applicant at the site meeting. Department: Internal Services Contact: Sarah Carter, 970-416-2748, scarter@fcgov.com Topic: Building Insp Plan Review Comment Number: 1 Comment Originated: 07/22/2016 07/22/2016: Please schedule a pre -submittal meeting with Building Services for this project. Pre -Submittal meetings assist the designer/builder by assuring, early on in the design, that the new projects are on track to complying with all of the adopted City codes and Standards listed below. The proposed project should be in the early to mid -design stage for this meeting to be effective. Applicants of new projects should email scarter@fcgov.com to schedule a 4 Comment Number. 11 winment Originated: 08/30/2016 08/30/2016: Is there a reason the 12' Utility Easement running through the property can't be vacated via the Plat? Is this a private easement or an easement that wasn't originally dedicated to the City? Comment Number: 12 Comment Originated: 08/30/2016 08/30/2016: Both the 15' access easement and the 20' emergency access easement need to define the starting elevation. Does the easement terminate 18 from finished grade, finished floor grade, etc. Please provide a station or elevation. Department: Environmental Planning Contact: Stephanie Blochowiak, 970-416-4290, sblochowiak@fcgov.com Topic: General Comment Number: 2 Comment Originated: 07/26/2016 090716: Thank you for providing further detail for landscape plan. Native Seed Mix looks good and Staff support addition of (orbs (specifically several wildflower species) to the mix; this will aid in more rapid establishment, help the native plants outcompete weed species, add to the site aesthetic while in bloom, and provide nutritional resources for local pollinator species. 07/26/2016: A more detailed Landscape Plan will be required and should include scientific names of all species proposed, including detailed information (species and seeding rate) for Native Seed Mixdenoted on current plan. Note the City of Fort Collins Land Use Code requires that to the extent reasonably feasible, all plans be designed to incorporate water conservation materials and techniques [3.2.1 E(3)]. This includes use of low- water -use plants and grasses in landscaping or re -landscaping and reducing bluegrass lawns as much as possible. Native plants and wildlife -friendly (ex: pollinators; songbirds) landscaping and maintenance are also encouraged. Please refer to the Fort Collins Native Plants document available online and published by the City of Fort Collins Natural Areas Department for guidance on native plants; the link is: hftp://www.fcgov.com/naturalareas/pdf/nativeplants20l3.pdf. Comment Number: 6 Comment Originated: 07/26/2016 090716: Thank you for selecting energy efficient and warmer color (3000K or less) luminaires and clearly identifying the selection on plans. 07/26/2016: Regarding site lighting and light fixtures, please note that The American Medical Association (AMA) and International Dark -Sky Association (IDA) both recommend using lighting that has a corrected color temperature (CCT) of no more than 3000 degrees Kelvin, in order to limit the amount of blue light in the night environment. Blue light brightens the night sky and creates more glare than any other color of light and exposure to blue light at night has been shown to affect human health and endanger wildlife. Therefore, use of warmer color temperature (warm white, 3000K or less) for light fixtures is preferred in addition to fixtures with dimming capabilities. For further information regarding health effects please see: http://darksky.org/ama-report-affirms-human-health-impacts-from-leds/ Comment Number: 5 Comment Originated: 08/01/2016 08/30/2016: Detail will be needed at final on the offsite improvements to the south as well as the sidewalk connections to the MAX Station. (Curb/driveway removal, etc.) 08/01/2016: More information is needed for the two sidewalks connecting to the MAX station. It appears that these walks will be crossing the existing drive aisle. Will this development propose removing the access? Based on existing conditions, ramps will be needed to get to the MAX station. Comment Number: 6 Comment Originated: 08/01/2016 08/30/2016: A letter of intent from the whole foods site will be needed prior to hearing. This offsite easement will be needed to be dedicated to the City and follow the City's easement dedication process. This easement will need to be shown on the plat as well. 08/01/2016: An offsite access easement will be needed to connect to the whole foods site to the south. This agreement will be needed prior to hearing. Comment Number: 8 Comment Originated: 08/30/2016 08/30/2016: Why has the 10' multi -use path to the south of the property been reconfigured? The 10' width should be maintained throughout and should try to maintain the direct connection from College Avenue. As proposed, the jog in the path around the tree will not work and could potentially pose a safety issue. Please work with Transportation Planning to determine a suitable sidewalk configuration. Comment Number: 9 Comment Originated: 08/30/2016 08/30/2016: There needs to be an access easement for the drive connection to the whole foods site along the driveway within the property. The portion of the multi -use path to the south that deviates from the direct path will also need to be included in an access easement. Please verify with Utilities which portions of the water services need to be within a Utility Easement. Comment Number: 10 Comment Originated: 08/30/2016 O8/30/2016: Add the private drive notice to the Plat. The following shall be placed on the plat set apart from the other notes in a box labeled as "NOTICE" when private drives are utilized on the property: "ALL RESPONSIBILITIES AND COSTS OF OPERATION, MAINTENANCE AND RECONSTRUCTION OF THE PRIVATE STREETS AND/OR DRIVES LOCATED ON THE PRIVATE PROPERTY THAT IS THE SUBJECT OF THIS PLAT SHALL BE BORNE BY THE OWNERS OF SAID PROPERTY, EITHER INDIVIDUALLY, OR COLLECTIVELY, THROUGH A PROPERTY OWNERS' ASSOCIATION, IF APPLICABLE. THE CITY OF FORT COLLINS SHALL HAVE NO OBLIGATION OF OPERATION, MAINTENANCE OR RECONSTRUCTION OF SUCH PRIVATE STREETS AND/OR DRIVES NOR SHALL THE CITY HAVE ANY OBLIGATION TO ACCEPT SUCH STREETS AND/OR DRIVES AS PUBLIC STREETS OR DRIVES." K of Fotrt Collins Community Development and Neighborhood Services 281 North College Avenue PO Box 580 Fort Collins, CO 80522 970.221.6750 970.224.6134 - fax fcgov. com/developmentreview September 10, 2016 Don Berland BERLAND DEVELOPMENT GROUP, INC 13394 E CONTROL TOWER RD Englewood, CO 80112 RE: Spring Creek Place, PDP160020, Round Number 2 Please see the following summary of comments from City staff and outside reviewing agencies for your submittal of the above referenced project. If you have questions about any comments, you may contact the individual commenter or direct your questions through the Project Planner, Ted Shepard, at 970-221-6343 or tshepard@fcgov.com. Comment Summary: Department: Engineering Development Review Contact: Marc Ragasa, 970.221.6603, mragasa@fcqov.com Topic: General Comment Number: 3 Comment Originated: 08/01/2016 08/30/2016: The easement for the multi -use path should be an access easement, not a sidewalk easement. 08/01/2016: An emergency access easement will be needed for the fire lane and an access easement will be needed for the 10' multi -use path to the south. These will need to be dedicated on the plat with any other easements that will be needed for drainage and utilities. Comment Number: 4 Comment Originated: 08/01/2016 08/30/2016: Utility Plans need to clearly delineate the building envelope to verify that portions of the building does not encroach into an easement. 08/01/2016: There are portions of the building to the west that encroach into the Utility easement. There is also the existing 12' utility easement that runs through the building. No easements can be within the building's footprint.