HomeMy WebLinkAboutMULBERRY & LEMAY CROSSING, LOT 2, CENTENNIAL BANK - MAJOR AMENDMENT - 36-96N - CORRESPONDENCE -4. Please either include a separate drawing for the floodplain information or include it on the grading plan. This plan should include the line showing the limits of the area removed from the floodplain, the BFE lines, the spot elevations to show all ground is still above the BFE, and the floor elevation. (refer to floodplain plan for the Home Depot as a reference) 5. A portion of the lot is still in the Poudre River floodplain and therefore is subject to the floatable materials regulation. The trash enclosure is in the area still in the floodplain. Therefore, the trash dumpster and recycle container must be anchored to the ground or wall so as to not float. Please include a detail of this anchoring.. One alternative is to move the trash enclosure to an area that was removed from the floodplain. Another alternative is to request a variance from the Water Board, which may be justified in this cae due to the fill placed at the Mulberry and Lemay Crossing project. The fill does not meet FEMA requirements, but the flow is blocked in reality. Please see Human Bean PDP utility plans for an anchoring detail example, if needed. 6. Please include a note on the grading plan that "no floatable materials may be stored in the floodplain area (This includes vehicles left overnight). 7. The elevation listed on sheet 2 for benchmark 8-02 is incorrect. However, the benchmark on sheet 3 is ok. Please review and revise as necessary. 8. A floodplain use permit and $25 permit fee will be required prior to the building permit being issued. Please include this note on the floodplain plan. Contact Marsha Hilmes- Robinson at 224-6036 if you have questions about the permit. 9. A FEMA Elevation Certificate completed by a licensed professional engineer or surveyor must be completed and approved prior to issuance of the Certificate of Occupancy. Please allow two weeks for review and changes. Please include this note on the plans. Department: Zoning Topic: zoning Issue Contact: Peter Barnes Number: 5 Created: 6/10/2005 [6/10/051 The internal parking lot landscaping in the south lot seems to be a little sparse. Add another landscape island in the middle of the southernmost row of parking. Be sure and return all of your redlined plans when you re -submit. If you have any questions regarding these issues or any other issues related to this project, please feel free to call me at (970) 221-6750. Yours Truly, Ted Shepard City Planner Page 3 which provided visual context to the river by adding larger cobble mulch and some native plant materials to their landscaped islands and along the eastern side of their building, Wal- Mart provided some native planting throughout their landscape and the over all development designed their detention pond with native wetland plantings. Centennial Banks buildings in this region I my opinion would typically meet this standard because of the sensitivity that their designs usually have due to the western character and color schemes that they choose and should be able to easily fit this standard, please contact Doug Moore at (970) 224-6143 to further discuss this issue. Department: PFA Issue Contact: Michael Chavez Topic: General Number: 3 Created: 6/6/2005 [6/6/05] PREMISES IDENTIFICATION: Approved numerals or addresses shall be provided for all new and existing building in such a position as to be plainly visible and legible from the street or road fronting the property. 1997 UFC 901.4.4 Number: 4 Created: 6/6/2005 [6/6/05] WATER SUPPLY: Commercial No commercial building can be greater then 300 feet from a fire hydrant. Fire hydrants are required with a maximum spacing of 600 feet along an approved roadway. Each hydrant must be capable of delivering 1500 gallons of water per minute at a residual pressure of 20 psi. 1997 UFC 901.2.2.2 Department: Police Issue Contact: Joseph Gerdom Topic: General Number. 8 Created: 6/15/2005 [6/15/05] Need photometric plan including under canopy area. Also, trash enclosure landscaping (dogwoods) offers areas for concealment - suggest orienting it toward building, provide lighting 1.0fc, and use lower plant materials. Department: Stormwater Utility Issue Contact: Wes Lamarque Topic: Stormwater Number. 6 Created: 6/14/2005 [6/14/05] Major Amendement is ready for a hearing. Additional comments may arise at final compliance. Topic: Stormwater-floodplain Number: 7 Created: 6/14/2005 [6/14/051 1. Most of the site, including the building, is within the area removed from the Poudre River floodplain by a LOMR-Fill dated 4/3/02. 2. One of the conditions of the LOMR-Fill is that all buildings and HVAC would be elevated 18" above the flood level. The flood level at the northwest comer of the building is 4932.5 based on the plans for the Home Depot and therefore the regulatory flood protection elevation is 4934. The proposed floor elevation of 4935.2 meets the elevation criteria. However, this issue needs to be discussed in the drainage letter. 3. Please include a note on the plans that the HVAC must be elevated to 4934. Page 2 STAFF PROJECT REVIEW City of Fort Collins VF RIPLEY ASSOCIATES Date: 6/21/2005 CATHY MATHIS 401 W MOUNTAIN AVE, SUITE 201 FORT COLLINS, CO 80521 Staff has reviewed your submittal for MULBERRY & LEMAY CROSSING, LOT 2, CENTENNIAL BANK MAJOR AMENDMENT, TYPE II, and we offer the following comments: ISSUES: Department: Engineering Issue Contact: Sheri Wamhoff Topic: General Number: 9 Created: 6/17/2005 [6/17/05] The title of the plans should be "Mulberry and Lemay Crossing, Filing No 3, Lot 2 —Centennial Bank..." Number. 10 Created: 6/17/2005 [6/17/05] Please show the building envelope on the utility plans (include the drive thru canopy). Number. 11 Created: 6/17/2005 (6/17/05] Label the easements. Number: 12 Created: 6/17/2005 [6/17/051 Mostly for your information there is a private no -build easement located in the plaza to the north of the property. I do not have any information on the dimensions of this. It may not impact this site at all — just wanted you to be aware of it. Number. 13 Created: 6/17/2005 (6/17/051 Ramps are shown at all driveway crossings except for the ones at the western driveway. I know that the Home Depot had planed for a bunch of the curb line to be flusth with the pavement, but_it is not clear if that is what is happening here. The utility plans have a note around part of this curb that it is outfall curb and gutter. Number: 14 Created: 6/17/2005 [6/17/05] 1 did not receive a landscape plan — I will review that next round. Department: Light & Power Issue Contact: Doug Martine Topic: Electric Number. 1 Created: 5/27/2005 [5/27/051 Developer will need to coordinate the transformer location and electric development charges with Light & Power Engineering (970)221-6700. Department: Natural Resources Issue Contact: Doug Moore Topic: General Number: 2 Created: 5/30/2005 [5/30/05] Since this project is located within the vicinity of the Poudre River Corridor we ask that this project comply with section 3.4.1 (1)(1)Design and Aesthetics, Project Design. Examples of how other projects in this area have met this standard include; Home Depot Page