HomeMy WebLinkAboutCENTERPOINT PLAZA - FDP - FDP160027 - CORRESPONDENCE - (5)07/01/2016: The irrigation plan is incomplete. Please refer to the provisions
outlined in Section 3.2.1(J) of the Land Use Code. Identify pressure reducing
heads and nozzles in legend. Irrigation code requires all spray heads to have
PRS (Pressure Reducing Stems) and check valves. Direct questions
concerning irrigation requirements to Eric Olson, at 221-6704 or
eolson@fcgov.com
Comment Number: 2
Comment Originated: 02/06/2017
02/06/2017: The irrigation plan is incomplete. Please refer to the provisions
outlined in Section 3.2.1(J) of the Land Use Code. Identify pressure reducing
heads and nozzles in legend. Irrigation code requires all spray heads to have
PRS (Pressure Reducing Stems) and check valves. Direct questions
concerning irrigation requirements to Eric Olson, at 221-6704 or
eolson@fcgov.com
Department: Water -Wastewater Engineering
Contact: Wes Lamarque, 970-416-2418, wlamargue@fcciov.com
Topic: General
Comment Number: 1
Comment Originated: 07/06/2016
02/10/2017: Repeat Comment
07/06/2016: Repeat comment.
12/01 /2015: Reminder comment for Final Compliance.
10/14/2015: Reminder comment for Final Compliance.
08/12/2015: Please show the proposed wet utilities on the landscape plan and
provide the required separation distances.
Comment Number: 2 Comment Originated: 07/06/2016
02/10/2017: Repeat Comment. Fire Hydrant Assembly has one, but not the fire
service.
07/06/2016: Please provide a thrust block for the swivel tee at the fire service.
Comment Number: 3 Comment Originated: 07/06/2016
02/10/2017: Repeat Comment. Please show the fire service to the building.
The fire service may need to be south of the water service to provide the
required separation from the sanitary service.
07/06/2016: Repeat comment.
12/01/2015: Please provide 10 feet separation between the water and sewer
services.
Comment Number: 4
Comment Originated: 02/10/2017
02/10/2017: There is a conflict with the fire hydrant and the tree within the
landscape island.
spillway elevation, invert at the outlet structure, etc.
Comment Number: 7 Comment Originated: 07/06/2016
02/10/2017: Repeat Comment
07/06/2016: Please label slope of concrete pan in pond bottom.
Comment Number: 8 Comment Originated: 07/06/2016
02/10/2017: Please place the pavers location on the Horizontal Control Plan as
well and label.
07/06/2016: Please clarify the exact location of the porous pavement areas,
Area 1 and Area 2.
Comment Number: 9
Comment Originated: 07/06/2016
02/10/2017: Repeat Comment
07/06/2016: City recommends using scour stop, or equal, at the storm sewer
outlet into the pond as well.
Comment Number: 10
Comment Originated: 07/06/2016
02/10/2017: Repeat Comment
07/06/2016: Please use the City's most current standard details.
Comment Number: 11
Comment Originated: 07/07/2016
02/10/2017: Repeat Comment
07/07/2016: Please round out the corners of the contours in the detention basin
to create a more natural looking bottom to the basin.
Department: Technical Services
Contact: Jeff County, 970-221-6588, icounty@fcgov.com
Topic: Construction Drawings
Comment Number: 7
Comment Originated: 07/05/2016
02/08/2017: *Repeat Comment* There are line over text issues. See redlines.
07/05/2016: *Repeat Comment* There are line over text issues. See redlines.
Comment Number: 8
Comment Originated: 07/05/2016
02/08/2017: *Repeat Comment* Some of the easement descriptions shown
are incorrect. If they are going to stay on the plan, they should match what is
shown on the Subdivision Plat.
07/05/2016: *Repeat Comment* Some of the easement descriptions shown
are incorrect. If they are going to stay on the plan, they should match what is
shown on the Subdivision Plat.
Comment Number: 9
02/08/2017: There are text over text issues. See redlines.
Topic: Site Plan
Comment Number: 1
Comment Originated: 02/08/2017
Comment Originated: 07/05/2016
02/08/2017: *Repeat Comment* There are line over text issues. See redlines.
07/05/2016: *Repeat Comment* There are line over text issues. See redlines.
Department: Water Conservation
Contact: Eric Olson, 970-221-6704, eolson@fcgov.com
Topic: General
Comment Number: 1 Comment Originated: 07/01/2016
01/31/2017: REVISE LIMITS OF EAE ON PLAT
> The Emergency Access Easement on the building's south side (Curve C32)
should be adjusted to include a 25' turn radius.
> The EAE on the far south end of the site should be adjusted to include the full
width of the drive lane at this point.
Comment Number: 5
Comment Originated: 01/31/2017
01/31/2017: REVISE FIRE LANE SIGN PLACEMENT
Revise "No Parking - Fire Lane" sign placement per redlines. If not already
provided, fire lane signage is required for the existing building to the north.
Refer to sign detail per updated LUCASS #1418. Code language provided
below.
> IFC D103.6: Where required by the fire code official, fire apparatus access
roads shall be marked with permanent NO PARKING - FIRE LANE signs
complying with Figure D103.6. Signs shall have a minimum dimension of 12
inches wide by 18 inches high and have red letters on a white reflective
background. Signs shall be posted on one or both sides of the fire apparatus
road as required by Section D103.6.1 or D103.6.2.
Department: Stormwater Engineering
Contact: Basil Harridan, 970-224-6035, bhamdan@fcgov.com
Topic: Erosion Control
Comment Number: 1 Comment Originated: 06/28/2016
02/07/2017: Please use an alternative method to protect the pond outlet as the
single rock sock as shown will allow a significant amount of sediment to exit the
pond. Please check redlines for additional comments.06/28/2016: Erosion
control plans and report have significant issues left to be resolved, most notably
outlet protection at the detention pond. Please see redlines and address all
comments in report and plans.
Contact: Wes Lamarque, 970-416-2418, wlamargue@fcqov.com
Topic: General
Comment Number: 2
Comment Originated: 07/06/2016
02/10/2017: Please remove existing contours for Sheet 7.
07/06/2016: Please remove the existing contours on the Utility Plan, sheet 5
and the Drainage Plan, sheet 7.
Comment Number: 3
Comment Originated: 07/06/2016
02/10/2017: Repeat Comment
07/06/2016: Please revise the Landscape Plan to match the Utility Plans.
Pond configuration is out of date as well as the paver areas.
Comment Number: 4 Comment Originated: 07/06/2016
02/10/2017: Repeat Comment
07/06/2016: Riprap pad can be removed on the south side of the detention
pond due to scour stop being proposed in this same location.
Comment Number: 5
Comment Originated: 07/06/2016
02/10/2017: Repeat Comment
07/06/2016: Please add more spot elevation to the grading plan including the
City of Fort Collins
Building Services
Plan Review
416-2341
Department: Light And Power
Contact: Tyler Siegmund, 970-416-2772, tsiegmund@fcgov.com
Topic: General
Comment Number: 1
Comment Originated: 07/06/2016
07/06/2016: Light and Power has electric facilities along the south side of
Midpoint Dr. that can be utilized to provide power.
Comment Number: 2
Comment Originated: 07/06/2016
07/06/2016: Please provide a one line diagram and Commercial Service Form
(C-1 form) to Light and Power Engineering. The C-1 form can be found at:
http://zeus.fcgov.com/utils-procedures/files/EngWiki/WikiPdfs/C/C-1 Form.pdf
Comment Number: 3 Comment Originated: 07/06/2016
07/06/2016: Electric capacity fees, development fees, building site charges
and any system modification charges necessary to feed the site will apply to this
development. Please visit the following website for an estimate of charges and
fees:
http://www.fcgov.com/utilities/business/builders-and-developers/plant-investmen
t-development-fees
Comment Number: 4
Comment Originated: 07/06/2016
07/06/2016: Light & Power will need AutoCAD files of the approved site plan,
utility plans, and landscape drawings before design of the electric facilities will
begin.
Comment Number: 5
Comment Originated: 07/06/2016
07/06/2016: The transformer must have a front clearance of 10 ft and side/rear
clearance of 3 ft minimum. It appears that the parking lot light pole will need to
be relocated away from the transformer to provide a minimum of 10ft clear.
Department: PFA
Contact: Jim Lynxwiler, 970-416-2869, ilynxwiler@poudre-fire.org
Topic: General
Comment Number: 3 Comment Originated: 01/25/2017
01/25/2017: SITE PLAN TURNING RADII
The radius at C32 does not meet minimum code requirements for a 20' wide
fire lane. Minimum turning radius is 25'. Code language provided below.
> IFC 503.2.4 and Local Amendments: The required turning radii of a fire
apparatus access road shall be a minimum of 25 feet inside and 50 feet
outside.
Comment Number: 4 Comment Originated: 01/31/2017
Comment Number: 1
07/12/2016:
Comment Originated: 07/12/2016
Building Permit Pre -Submittal Meeting:
Pre -Submittal meetings are required to assist the designer/builder by assuring,
early on in the design,
that the new commercial or multi -family projects are on track to complying with
all of the adopted City
codes and Standards listed below. The proposed project should be in the early
to mid -design stage for
this meeting to be effective and is typically scheduled after the Current Planning
conceptual review
meeting. Applicants of new commercial or multi -family projects are advised to
call 416-2341 to schedule
a pre -submittal meeting. Applicants should be prepared to present site plans,
floor plans, and elevations
and be able to discuss code issues of occupancy, square footage and type of
construction being proposed.
Construction shall comply with the following adopted codes as amended:
2012 International Building Code (IBC)
2012 International Residential Code (IRC)
2012 International Energy Conservation Code (IECC)
2012 International Mechanical Code (IMC)
2012 International Fuel Gas Code (IFGC)
2012 International Plumbing Code (IPC) as amended by the State of Colorado
2014 National Electrical Code (NEC) as amended by the State of Colorado
Fort Collins has amendments to most of the codes listed above. See the
fcgov.com web page to view them.
Accessibility: State Law CRS 9-5 & ICC/ANSI Al17.1-2009.
Snow Load Live Load: 30 PSF / Ground Snow Load 30 PSF.
Frost Depth: 30 inches.
Wind Load: 100- MPH 3 Second Gust Exposure B.
Seismic Design: Category B.
Climate Zone: Zone 5
Energy Code Use
1. Single Family; Duplex; Townhomes: 2012 IRC Chapter 11 or 2012 IECC.
2. Multi -family and Condominiums 3 stories max: 2012 IECC residential
chapter.
3. Commercial and Multi -family 4 stories and taller: 2012 IECC commercial
chapter.
Centerpoint — project specific concerns:
1. Upgraded insulation is required for buildings using electric heat or cooling.
2. Exterior walls and roof must meet a STC (sound resistance) rating of 40 min.
if building located within 1000ft to train tracks.
3. Low -flow Watersense plumbing fixtures (toilet, faucets, shower heads) are
required.
4. Low VOC interior finishes.
Fort Collins
Community Development and
Neighborhood Services
281 North College Avenue
PO Box 580
Fort Collins, CO 80522
970.221.6750
970.224.6134 - fax
fcgov. com/developmen [review
February 10, 2017
Keith Moore
RMG ARCHITECTS
2910 AUSTIN BLUFFS PKWY
Colorado Springs, CO 80918
RE: Centerpoint Plaza, FDP160027, Round Number 2
Please see the following summary of comments from City staff and outside reviewing
agencies for your submittal of the above referenced project. If you have questions about
any comments, you may contact the individual commenter or direct your questions through
the Project Planner, Clay Frickey, at 970-224-6045 or cfrickey@fcgov.com.
Comment Summary:
Department: Engineering Development Review
Contact: Katie Andrews, 970-221-6501, kandrews@fcgov.com
Topic: General
Comment Number: 6
Comment Originated: 02/07/2017
02/07/2017: Plans look good - we have started working on the DA. I believe an
excavation permit will be required prior to starting work - I'll confirm this and let
you know soon.
Department: Forestry
Contact: Tim Buchanan, 970-221-6361, tuchanan@fcgov.com
Topic: Landscape Plans
Comment Number: 10 Comment Originated: 07/08/2016
07/08/2016:
Written acknowledgment of the approval of the Landscape Plan needs to be
provided from Platte River Power Authority for trees to be planted in their
easement.
Department: Internal Services
Contact: Russell Hovland, 970-416-2341, rhovland@fcgov.com
Topic: Building Insp Plan Review