HomeMy WebLinkAboutBELLA VISTA - PDP - 45-01A - SUBMITTAL DOCUMENTS - ROUND 1 - CORRESPONDENCE-CONCEPTUAL REVIEWC�o���� o 0
urban design, inc.
14. Please Note: If there is a subdivision plat as part of this development request
the following requirement must be met:
The applicant must provide a copy of "Certificate of Taxes Due" with the
mylar of the subdivision plat when it is brought to the City's Current
Planning Department for recording. The certificate may be obtained from
the Larimer County Treasurer's Office and must reflect a zero (0) balance
before the City will accept the mylar. Larimer County is requiring this
document, showing no outstanding property taxes, before they will accept
and record subdivision plats.
So noted.
Sincerely,
Eldon Ward
Cityscape Urban Design, Inc.
cc: Chuck McNeal, Stanford Development, LLC
Javier Martinez Campos, Stanford Development, LLC
Frank Vaught, Vaught * Frye Architects
Bud Curtiss, Northern Engineering
COy'W o
urban design, inc.
e. There may be water quality issues associated with this development.
Water quality measures are included in the drainage plans.
Please contact Doug, at 224-6143, if you have questions about these comments.
9. Jeff Lakey of the Parks Planning Department indicated that each residential
dwelling unit will be subject to both the Neighborhood and the Community
Parkland fees, which are based on the square footage of the dwelling unit. The
fees will be collected at the time of issuance of building permits.
So noted.
10. The Planning Department has concerns about some of the potential uses in this
development. The project is intended to serve as a neighborhood center, which
typically includes residential uses and commercial uses that are more of a
personal services nature. The amount, type, and size of retail and food service
(restaurant) uses should be minimized.
Limitations on non-residential uses are included in the General Notes on the PDP
11. A neighborhood meeting must be held for this development proposal prior to
formal submittal of a PDP.
A neighborhood meeting was held on November 14m
12. This development request will be subject to the current Development Review Fee
Schedule that is available in the Current Planning Department office. The fees
are due at the time of submittal of the required documents for the Project
Development Plan and Final Compliance phases of development review by City
staff and affected outside reviewing agencies.
Required fees are included with the PDP submittal.
13. This development proposal is subject to the requirements as set forth in the
City's LUC, specifically Articles 2. Administration (Development Review
Procedures), Article 3. General Development Standards, and Article 4.
[Applicable Zoning] Districts.
To the best of our knowledge, the site has been designed accordingly, and in keeping
with the basic goals, principles and policies of City Plan.
CoM@@ o
urban design, inc.
g. Coordinate the necessary transformer locations with Light & Power. The
transformers must be within 10' of a paved area that is accessible to City
line trucks.
h. The City probably will install 2 street lights along East Horsetooth Road in
this area.
The site has been planned accordingly. As discussed at the Conceptual Review
Meeting, we anticipate the electric line extension along Horsetooth Road to be
located under the six foot walk, with vaults located in the adjacent tree lawn or
utility easement. The electrical engineer for the project will meet with Doug
regarding the details of service to the proposed buildings. We anticipate receipt
of street light locations from Light & Power at the requested Utility Coordination
Meeting, and will adjust street locations accordingly with PDP revisions.
Please contact Doug, at 224-6152, if you have questions about these comments.
8. Doug Moore of the Natural Resources Department offered the following
comments:
a. Native plant materials and grasses should be incorporated in the
Landscape Plan for the new residence. The use of bluegrass should be
minimized.
A "water wise" landscape approach — including turf areas with moderate irrigation
needs - has been used in the proposed landscape plan.
b. The trash enclosures should be designed to be able to include recycling
facilities.
An area for recycling polycarts has been included in the trash enclosure.
C. Please contact Tim Buchanan, the City Forester, to discuss the City's
tree protection standards pertaining to any existing trees on -site. Tim can
be reached at 221-6361.
There are no existing trees on this site.
d. A Fugitive Dust Control Permit will be required and this permit is issued by
the Larimer County Environmental Health Department. Please contact
them directly to discuss this requirement.
So noted.
urban design, inc.
the Traffic Operations Department, at 224-6062, and Tom Reiff of the
Transportation Planning Department, at 416-2040, to determine what
information is needed in the TIS pertaining to Level of Service for vehicle,
pedestrian, bicycle, and transit modes of transportation.
Matt Delich, our traffic consultant, has contacted Eric and Tom, and prepared the
TIS accordingly.
b. What is the status of East Horsetooth Road regarding ultimate width, turn
lanes, and bicycle lanes?
Cross sections illustrating the proposed configuration for East Horsetooth Road
are included with the PDP. We are proposing improvements to the north side of
Horsetooth meeting current City Standards; and are suggesting a section that will
allow a narrow bike lane to be retrofitted into the existing improvements on the
south side between Landings Drive and Spin Drift Court-
C
. Pedestrian access to the existing Aspen Leaf Apartments should be
provided from this development.
We have included a pedestrian link to the Aspen Leaf site at a logical location.
Please contact Tom, at 416-2040, if you have questions about these comments.
7. Doug Martine of the Light & Power Department offered the following
comments:
a. This development will be subject to the standard electric development
charges.
b. This development will probably require 3-phase power, which could be of
concern to the City. Please coordinate power requirements with Light &
Power.
C. There is not yet an electric line along East Horsetooth Road.
d. It could be expensive to provide for long electric service lines.
e. There are Code requirements for the amount of cover over electric lines.
This development probably will be served with gang meters, which must
be accessible to City line trucks.
urban design, inc.
Department, at 416-2040, to determine what information is needed in the
TIS pertaining to Level of Service for vehicle, pedestrian, bicycle, and
transit modes of transportation.
The required TIS is included with the PDP submittal.
C. Any additional street right-of-way that is needed must be dedicated with
this development. All necessary easements must also be dedicated.
The site has been designed accordingly.
d. The design of East Horsetooth Road will be subject to the Larimer County
Urban Area Street Standards.
Horsetooth Road has been fully constructed to the east, west, and at the south
curb, gutter and walk as per the standards in effect at that time. We are
proposing right-of-way on the north half; adjacent to this site that meets the new
standards. We have also included street cross sections showing existing and
proposed conditions along Horsetooth Road. As a small in -fill site street design
standards cannot be applied here in the same manner they are applied at new
developments in out -lying locations.
e. All access points must meet the sight distance standards.
A site distance easement has been noted related to the proposed full movement
access and the visibility of northbound traffic on Stanford.
f. The standard utility plan submittal requirements will apply to this
development request.
So noted.
g. Both a Development Agreement and a Development Construction Permit
will be required for the site improvements.
So noted.
Please contact Katie, at 221-6750, if you have questions about these comments.
6. Tom Reiff of the Transportation Planning Department offered the following
comments:
a. A TIS, addressing all modes of transportation, will be required with your
Project Development Plan (PDP) submittal. Please contact Eric Bracke of
CUkn@@P@
urban design, inc.
The site grading and drainage plans have been prepared accordingly; and as per
the October 315t letter from Nicholas Haws of Northern Engineering to Wes
Lamarque at the Stormwater Utility.
While there is high ground water at other sites in the area, the geotechnical
survey for this property did not rind such conditions here.
Please contact Glen Schlueter, at 224-6065, if you have questions about these
comments.
4. Ron Gonzales of the Poudre Fire Authority offered the following comments:
a. A fire hydrant must be located within 300' of each building and spaced no
further than 600' apart.
b. The buildings will have to fire sprinklered.
C. Fire flows of 1,500 gallons per minute at a residual pressure of 20 pounds
per square inch must be provided.
d. Addressing for the buildings (minimum 6" high numerals) must be visible
from the closest street that that they front on.
e. An unobstructed fire lane, a minimum of 20' in width, must be provided
across the above -grade parking lot.
The site has been designed accordingly.
Please contact Ron, at 221-6570, if you have questions about these comments.
5. Katie Moore of the Engineering Department offered the following comments:
a. Street oversizing fees will apply to this development request. The fees will
be collected at the time of issuance of building permits. Please check with
Matt Baker of the Engineering Department, at 224-6108, for the fees
based on the land uses.
So noted.
b. A Transportation Impact Study (TIS), addressing all modes of
transportation, will be required with your Project Development Plan (PDP)
submittal. Please contact Eric Bracke of the Traffic Operations
Department, at 224-6062, and Tom Reiff of the Transportation Planning
C�o����caa o 0
urban design, inc.
d. The City's water conservation standards for landscape and irrigation will
apply to this development.
e. Plant investment fees and water rights will apply and they will be collected
at the time of issuance of building permits.
f. Maintain an easement for the sanitary sewer, 15' each side of the main.
An alternate width may be considered when utility plans are submitted.
g. Grease interceptors are required for any restaurants.
Utility plans have been designed with 'a' through 'e' (above) in mind.
Regarding the easement width for the existing sanitary sewer: Because the
sewer is relatively shallow at this location; because there are no manholes on -
site; because this is only a short stretch of a very long existing 20' wide
easement; and because this is a small, constrained site, we are proposing that
the easement remain at 20' wide. Some additional width on the side of the
easement away from the buildings could be provided if needed. We will review
this item further at the requested Utility Coordination Meeting.
Any food service uses included are anticipated to be small in size, and are
unlikely to include deep fat fryers and the like. It is our understanding therefore,
that grease interceptors may not be needed.
Please contact Roger, at 221-6854, if you have questions about these
comments.
3. Glen Schlueter of the Stormwater Utility offered the following comments:
a. This site is in the City's Foothills Drainage Basin. The new development
fee is $6,525 per acre, which is subject to the runoff coefficient reduction.
b. The standard drainage and erosion control reports and constructions
plans are required and they must be prepared by a professional engineer
registered in the State of Colorado.
C. On -site water quality extended detention is required.
d. An off -site drainage easement may be required.
e. The 100-year flows must go into the streets, not the parking garage.
f. There is high groundwater in this area
COYPIQo
urban design, inc.
alternative — constructed — amenity approach to providing visual relief in the
upper level parking area.
d. Parking bays shall extend no more than 15 parking spaces without an
intervening tree, landscape island or landscape peninsula, as set forth in
Section 3.2.1(E)(5)(e).
* (See `c' above).
e. The trash enclosure locations appear to be inconvenient to most of the
buildings.
We have — in this case — given priority to aesthetic and livability considerations
over convenient access to the trash enclosure. The degree of inconvenience is
reduced by the fact that initial trash collection will be handled within the
elevator/service cores of the occupied buildings. Maintenance personnel and
employees of the non-residential uses will convey refuse from the buildings to the
trash enclosure.
f. This property is in the Residential Neighborhood Sign District, which is
more restrictive than areas excluded from this District. The City's Sign
Code, administered by the Zoning Department, will determine the
allowable signage for this development.
So noted.
Please contact Jenny, at 221-6760, if you have questions about these
comments.
2. Roger Buffington of the Water/Wastewater Department offered the following
comments:
a. There is an existing 20" water main in East Horsetooth Road and an
existing 12" water main in Stanford Road.
b. There is an existing 8" sanitary sewer main in East Horsetooth Road,
along the east % of the site, and an existing 8" sewer main that crosses
the southwest corner of the site in a west-northwest orientation.
C. Separate water and sanitary sewer services are required for the
commercial and residential portions of the mixed -use buildings.
November 28, 2001
Steve Olt
City of Fort Collins
Community Planning and Environmental Services
P.O. Box 580
Fort Collins, CO 80522
RE: Bella Vista PDP — Conceptual Review Comments
Dear Steve;
coovs§@P(P
urban design, inc.
3555 Stanford road, suite 105
fort collins, colorado 80525
(970) 226-4074
fax (970) 226-4196
e@cityscapeud.com
Included below are the comments received from City Staff regarding the October
29th Conceptual Review for this project. An explanation (in italics) of how issues have
been addressed follows each comment.
COMMENTS:
1. Jenny Nuckols of the Zoning Department offered the following comments:
a. The property is in the T — Transition Zoning District. The property will have
to be rezoned to be able to be developed.
A request for MMN — Medium Density Mixed Use Neighborhood zoning, has
been submitted.
b. This property is not yet platted; therefore, a subdivision plat must be
included in the Project Development Plan (PDP) submittal package.
A plat is being submitted concurrently with the PDP package.
C. The surface parking (above parking garage) must provide for at least 6%
interior landscaping, as set forth in Section 3.2.1(E)(5) of the Land Use
Code (LUC).
It is our understanding that this requirement has not been imposed on the upper
decks of any other structured parking facilities in Fort Collins. It is not clear why
this parking structure should be held to a different standard. We are in fact
proposing a significant amount of planting above the underground parking in
planter boxes around the perimeters of the occupied building structures. The
extreme cost and structural engineering considerations relating to providing
landscape planting areas above structured parking have caused us to be
judicious in the placement of such plantings. We are therefore suggesting an