Loading...
HomeMy WebLinkAbout626 S. WHITCOMB FOUR-PLEX - PDP/FDP - FDP140023 - CORRESPONDENCE -Comment N )er: 10 C nent Originated: 10/07/2014 02/23/2015: There are still line over text issues. See redlines. 10/07/2014: There are line over text issues. See redlines. Comment Number: 12 Comment Originated: 02/23/2015 02/23/2015: There is text that needs to be masked. Mask all text in hatched areas. See redlines. Comment Number: 13 Comment Originated: 02/23/2015 02/23/2015: Please add a legal description for the property to sheet Al. Department: Traffic Operation Contact: Martina Wilkinson, 970-221-6887, mwilkinson aRfcgov.com Topic: General Comment Number: 1 Comment Originated: 10/07/2014 10/07/2014: No comments from traffic operations or transportation planning. Department: Water Conservation Contact: Eric Olson, 970-221-6704, eolsono-fcgov.com Topic: General Comment Number: 1 Comment Originated: 10/02/2014 10/02/2014: Irrigation plans are required no later than at the time of building permit. The irrigation plans must comply with the provisions outlined in Section 3.2.1(J) of the Land Use Code. Direct questions concerning irrigation requirements to Eric Olson, at 221-6704 or eolson@fcgov.com Page 7 of 7 Comment Nt er: 1 Cr lent Originated: 10/07/2014 10/07/2014: No Comment from Erosion Control. This site; disturbs less than 10,000 sq-ft, is not in a sensitive area, and is not in a larger development under construction. Therefore, no submittal of erosion control material is needed. However, the site still must be swept and maintained to prevent dirt, saw cuttings, concrete wash, and other pollutants from entering the storm sewer at all times or BMPs will be required of the site. If you need clarification concerning this, or if there are any questions please contact Jesse Schlam 970-218-2932 or email @ jschlam@fcgov.com Department: Technical Services Contact: Jeff County, 970-221-6588, icounty(cDfcgov.com Topic: Building Elevations Comment Number: 1 Comment Originated: 10/07/2014 02/23/2015: There are still line over text issues. See redlines. 10/07/2014: There are line over text issues. See redlines. Topic: Construction Drawings Comment Number: 3 Comment Originated: 10/07/2014 02/23/2015: The benchmark statement must match the format shown in the previous comment. We would recommend using the updated 1984 description, rather than the 1934 description shown on the plans. 10/07/2014: The City has moved to the NAVD88 vertical datum. Please provide elevations for both the NAVD88 & NGVD29 (Unadjusted) datums, state the project datum, and provide an equation to get from NAVD88 to NGVD29 Unadjusted, i.e. NAVD88 = NGVD29 Unadjusted + X.XX'. Comment Number: 6 Comment Originated: 10/07/2014 02/23/2015: This has not been corrected. 10/07/2014: The benchmark descriptions on sheet 2 should match sheet 1. Comment Number: 7 Comment Originated: 10/07/2014 02/23/2015: There are still line over text issues. See redlines. 10/07/2014: There are line over text issues. See redlines. Comment Number: 15 Comment Originated: 02/23/2015 02/23/2015: There are text over text issues. See redlines. Comment Number: 16 Comment Originated: 02/23/2015 02/23/2015: There is text that is too bold. Please lighten it up. See redlines. Topic: General Comment Number: 14 Comment Originated: 02/23/2015 02/23/2015: FLOOR PLAN: There are line over text issues. See redlines. Topic: Landscape Plans Comment Number: 8 Comment Originated: 10/07/2014 02/23/2015: There are still line over text issues. See redlines. 10/07/2014: There are line over text issues. See redlines. Comment Number: 9 Comment Originated: 10/07/2014 02/23/2015: Please correct the spelling of "Edging" on sheet 2c. See redlines. 10/07/2014: The titles do not match the index on sheet 1. See redlines. Topic: Site Plan Page 6 of 7 Department: Light Am Contact: Justin Fields, Topic: General >wer 970-224-6150, ifields(&fcgov.com Comment Number: 1 Comment Originated: 10/07/2014 10/07/2014: The electric service to the existing duplex will need to be relocated around the new building. Comment Number: 2 Comment Originated: 10/07/2014 10/07/2014: System modification and development charges may exceed $2670. Contact Light and Power Engineering, 970-221-6700, for an estimate of these charges. Department: Stormwater Engineering Contact: Dan Mogen, dmogen(d)fcgov.com Topic: General Comment Number: 2 Comment Originated: 10/07/2014 02/26/2015: Please further distinguish contours from other site features. 10/07/2014: Please provide additional detail and improvement in readability (ie. existing and proposed contours use the same linetypes on the drainage & grading plan sheets. Comment Number: 3 Comment Originated: 10/07/2014 02/26/2015: Please provide additional detail with spot elevations to clarify breakpoints and basin deliniations. 10/07/2014: Please identify the different drainage basins in the plans. Comment Number: 7 Comment Originated: 10/07/2014 02/26/2015: Please provide table including new impervious area, impervious area treated by LID, new pavement area, porous pavement area, etc. Please email me at dmogen@fcgov.com and I will provide a sample LID table. 10/07/2014: Please provide a table showing that LID requirements are met. Comment Number: 8 Comment Originated: 10/07/2014 02/26/2015: Please document off -site flows in the drainage letter. 10/07/2014: Off -site flows are undocumented. Please provide additional details documenting any off -site flows entering this property and any flows from this site that drain to adjacent properties. Comment Number: 10 Comment Originated: 02/26/2015 02/26/2015: Per discussions, please update the underdrain for the permeable pavers to drain to the east into the alley. Discussion was to increase to 6" PVC and provide detail on outfall daylighting thru a short retaining wall. Comment Number: 11 Comment Originated: 02/26/2015 02/26/2015: Please provide additional detail on the profile for the permeable paver section and provide calculations to support the storage volume of 437 cubic feet listed in the drainage letter. City detail D-54 available at: http://www.fcgov. com/utilities/img/site_specific/uploads/D54. pdf Comment Number: 12 Comment Originated: 02/26/2015 02/26/2015: Please update discharge rate and location for basin 2. Contact: Jesse Schlam, 970-218-2932, ischiam(a)fcgov.com Topic: Erosion Control Page 5 of 7 Comment Nt er: 1 Cc lent Originated: 09/24/2014 09/24/2014: Building Permit Pre -Submittal Meeting Pre -Submittal meetings are offered to assist the designer/builder by assuring, early on in the design, that the new commercial or multi -family projects are on track to complying with all of the adopted City codes and Standards listed below. The proposed project should be in the early to mid -design stage for this meeting to be effective and is typically scheduled after the Current Planning conceptual review meeting. Applicants of new commercial or multi -family projects are advised to call 416-2341 to schedule a pre -submittal meeting. Applicants should be prepared to present site plans, floor plans, and elevations and be able to discuss code issues of occupancy, square footage and type of construction being proposed. Construction shall comply with the following adopted codes as amended: 2012 International Building Code (IBC) 2012 International Residential Code (IRC) 2012 International Energy Conservation Code (IECC) 2012 International Mechanical Code (IMC) 2012 International Fuel Gas Code (IFGC) 2012 International Plumbing Code (IPC) as amended by the State of Colorado 2011 National Electrical Code (NEC) as amended by the State of Colorado Accessibility: State Law CRS 9-5 & ICC/ANSI A117.1-2009. Snow Load Live Load: 30 PSF / Ground Snow Load 30 PSF. Frost Depth: 30 inches. Wind Load: 100- MPH 3 Second Gust Exposure B. Seismic Design: Category B. Climate Zone: Zone 5 Energy Code Use 1. Single Family; Duplex; Townhomes: 2012 IRC Chapter 11 or 2012 IECC. 2. Multi -family and Condominiums 3 stories max: 2012 IECC residential chapter. 3. Commercial and Multi -family 4 stories and taller: 2012 IECC commercial chapter. Fort Collins Green Code Amendments effective starting 1-1-2012. A copy of these requirements can be obtained at the Building Office or contact the above phone number. Whitcomb duplex — project specific concerns: 1. Fire -sprinkler systems are required. Anew code amendment effective in 2014 will require a residential sprinkler system. 2. Bedroom egress windows required below 4th floor regardless of fire -sprinkler. 3. All windows above the 1st floor require minimum sill height of 24" 4. If the duplexes are connected then it changes to a 4-plex multi -family building under the IBC and must be sprinkled with a 13 system and the project scope will change. 5. New Green Code requires: a. Upgraded insulation is required for buildings using electric heat or cooling.. b. Low -flow Watersense plumbing fixtures (toilet, faucets, shower heads) are required. c. Special combustion safety requirements for natural draft gas appliances. d. Low VOC interior finishes. City of Fort Collins Building Services Plan Review 416-2341 Page 4 of 7 Comment N oer: 1 C. nent Originated: 10/07/2014 10/07/2014: The submitted architectural elevations were evaluated under Municipal Code Section 14-72 and were determined to not have any adverse impacts to the existing historic building. Therefore, there is no further Historic Preservation Department review of these plans. Department: Internal Services Contact: Russell Hovland, 970-416-2341, rhovland(a)fcgov.com Topic: Building Insp Plan Review Page 3 of 7 Comment Nt er: 10 Cr lent Originated: 10/06/2014 02/23/2015: On the elevations sheet A5, it appears the labels for the east and west elevations were transposed. Comment Number: 11 Comment Originated: 10/06/2014 02/23/2015: The response comments note the lighting catalog cut sheets made it on to a sheet 10, but I did not see a sheet 10 with this submittal. Comment Number: 12 Comment Originated: 02/25/2015 2/26/2015: The land use table on the site plan should be updated: the parcel size should be listed as 9,500 square feet and should not include any area within the public right-of-way. The floor area ratios / coverage areas should also be updated with new calculations using a parcel size of only 9,500 square feet. Comment Number: 13 Comment Originated: 02/27/2015 10/07/2014: From the City's GIS Department: Projects with three or more tenant units require the Unit Level Addressing form to be completed and submitted to the GIS Department once plans have met final approval through Development Review and are recorded with the City. This can occur anytime during construction, but before any utilities or address signs are installed. All addressing will be determined by the GIS Department and submitted to Poudre Fire Authority, USPS, Building Services, and Fort Collins Utilities. Failure to contact GIS and determining addresses through other means may result in address changes. The Unit Level Addressing form can be obtained by contacting the GIS office at gis@fcgov.com or (970) 416-2483. Department: Engineering Development Review Contact: Marc Virata, 970-221-6567, mvirata(&fcoov.com Topic: Construction Drawings Comment Number: 5 Comment Originated: 02/24/2015 02/24/2015: On the approval block of the cover sheet, please correct the alignment of the titles underneath the signature lines. Topic: General Comment Number: 6 Comment Originated: 02/24/2015 02/24/2015: It should be verified with City Stormwater whether a development agreement will be required with this project and coordinate development agreement language after a public hearing. Comment Number: 7 Comment Originated: 02/24/2015 02/24/2015: The tree protection/mitigation plan shows the removal of trees outside of the development plan on the property to the north. Do we have written okay (letter of intent) from that property owner to remove the trees? Department: Environmental Planning Contact: Lindsay Ex, 970-224-6143, Iex(a)fcoov.com Topic: General Comment Number: 1 10/03/2014: No comments. Comment Originated: 10/03/2014 Department: Historical Preservation Contact: Josh Weinberg, 970-221-6206, iweinberg(cDfcgov.com Topic: General Page 2 of 7 City of Fort Collins February 27, 2015 Dick Anderson Anderson Assoc. Architects/Engineers LLC 422 E. Oak St Fort Collins, CO 80524 RE: 626 S. Whitcomb Four Plex, FDP140023, Round Number 2 Community Development and Neighborhood Services 281 North College Avenue PO Box 580 Fort Collins, CO 80522 970.221.6750 970.224.6134 - fax fcgov. corn/developmentmview Please see the following summary of comments from City staff and outside reviewing agencies for your submittal of the above referenced project. If you have questions about any comments, you may contact the individual commenter or direct your questions through the Project Planner, Ryan Mounce, at 970-224-6186 or rmounce@fcgov.com. Comment Summary: Department: Planning Services Contact: Ryan Mounce, 970-224-6186, rmounce(cDfcgov.com Topic: General Comment Number: 3 Comment Originated: 10/06/2014 02/23/2015: For potential consideration, there may still be room to add back in an additional parking stall using long-term vehicle dimensions and a portion of the bluegrass lawn, and still leaving an adequate hammerhead/turnaround. Long-term vehicle dimensions are 8.5' wide and 18' long. If an additional space is added to the parking lot, the requirement for the parking lot fence on the south and north side will remain. If the existing parking configuration remains, the parking stalls need to be widened slighlty to 8.5'. Comment Number: 5 Comment Originated: 10/06/2014 02/23/2015: Prior to the public hearing, some additional information is needed for each of the modification of standards requests. Each request should identify the specific rationale for the modification (see handout for a list of the justifications) along with an explanation of how that justification applies. For instance, prior discussions for the modification to LUC 3.8.30(F)(1) on the multifamily buffer yard have focused on the first rationale of providing an equal to or better than experience through protection of privacy, landscaping/screening elements, and building design. Comment Number: 7 Comment Originated: 10/06/2014 02/23/2015:: Please provide a digital copy of the communications with the adjacent property owner regarding removal of the trees to be included as an attachment for the public hearing. Page 1 of 7