HomeMy WebLinkAboutLOFTS AT CAMPUS WEST (THE) - PDP/FDP - 28-97 - CORRESPONDENCE - (9)Lofts at Campus West (page 2 of 2) July 8, 1998 Utility Plans Master Improvements Plan Provide a legend/key parking stalls and the • Provide dimensions for improvements specifically, drive through lane, drive lanes. • uth property line. What is the height of this? What are the The retaining wall along the so - currently a curb. What does a cross section of this area limits of this? What is it retaining look like? line (that is flush with the pavement) going • How is the walk on the south side of the property to transition up to match the landscaping and then drop for the ramps. Master Utility Plan • Show the pavement patch Master Grading Plan are too hi h The rise of approx 1 ft over 5 ft is • I still believe that the weirs (speed bumps) g too abrupt. I think there will be a problem with cars high centering on these and vehicles scraping on them/ taking chunks out of them and possibly causing the weir height to end up being lower than required. • At the weir locations need to indicate the curb height is at 30.8 or higher. Is there a curb around the trash enclosure pads? What is going to keep the water in here? Master Drainage and Erosion Control Plan • notes on this plan need to be submitted in writing The variance requests that are indicated as as separate items. The variance for allowable ponding depth in a parking lot will probably not be granted. It has not been for residential projects and has been a major concern of planing and zoning board. This is per conversation with Stormwater and was not caught by them and is not in there comments. See additional comments on plans. W DATE: June 4, 1998 TO: Engineering PROJECT: #28-97 Lofts @ Campus West - (LUC) Type I PDP AffseonuumWenust be received by Mike Ludwig no later than theliM098 reVi�wwmeatjngpded for all off -site work being done Site Plan Wednesday, July 8,1998 • Not meeting the landscape requirements on the north and East propertylines. A 5 foot landscape strip is required and this can not include vehicle overhang. An additional 2 %z feet of landscaping is needed to accommodate overhang and provide the landscape buffer required. Per section 3.2.2(N). • Label the retaining wall along the southern property line. Is the height of this wall adequate to prevent vehicle overhang? If not than curb stops are needed to prevent overhang. • Need to indicate where signage for compact spaces is to be located. For each site it needs to be placed so that it does not interfere with the pedestrian paths and the widths being provided. • No retaining walls or signage can be placed within the Row. Encroachment permits for fencing within the Row can be applied for. A yearly fee is assessed for such items within the Row. • Is the trash enclosure detail typical for all enclosures? • Show proposed signage locations for McDonalds signage. Want to make sure that it doesn't conflict with landscaping. Plat • Show the utility easements needed for the water services and shown on the utility plans. (Continued on next page) tar�.n.�nu�.a r�►sLd�� �or o1f �rS��O. wed, deru_ / I Date:g4 g Signature: W CBEECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS Plat ✓Site _ )Damage Report _ Other a �/ Utility iiRedline Utility elands* Citv of F.......Fort Colthis 3. The offsite drainage exhibit provided is insufficient. The off -site basins and design points need to be clearly delineated and labeled wherever applicable on the plans. RESPONSE: 4. Please recalculate the required detention volume using the correct rainfall intensities for the 100-year storm (repeat comment). RESPONSE: 5. There is concern about adjacent buildings in the Town Square shopping center flooding due to emergency overflow of the detention pond resulting from the orifice being clogged. Please provide flood -proofing measures. RESPONSE: 6. This project needs to address water quality issues since it is a new Land Use Code project. RESPONSE: Erosion/Sediment Control Comments Second Submittal Comments 1. Most of this site grades steeply from the north to the south and east onto existing asphalt. There'is no discussion in the report, and nothing shown on the plans defining how sediment transport is to be controlled on -site prior to paving, sod installation, etc. Please provide this information. 2. Effectiveness calculations use P-factors for straw bales and roughened ground. Calculations do not include a gravel inlet filter. Your report and your plan do not indicate roughened ground. What is the plan? In what sequence of the construction are any of these BMP's to be used?' Which BMP's? 3. The project schedule on the plan indicates silt fence is to be installed. There is no mention of this in the report and none shown on the plan. Is it is, or is it ain't?? 4. The project schedule indicates both seeding and sodding. Is this correct? If so, which goes where? 5. The plan needs standard erosion/sediment control notes. 6. The plan needs BMP drawings. MOTWON 4r Yt:�E u•l�yq'��,'/ DATE: June 4, 1998 TO: Stormwater PROJECT: #28-97 Lofts @ Campus West - (LUC) Type I PDP All comments must be received by Mike Ludwig no later than the staff review meeting: Wednesday, July 8,1998 1. Please show drainage easements from the site to west Elizabeth Street, including all alleys. Drainage easements for this area will need to be dedicated, if easements do not exist. Are the easements large enough to accommodate the increase in flow? Also provide signed agreements with the owners of the properties that will be affected with. the proposed construction. The letters of intent must be signed before the public hearing (repeat comment). RESPONSE: 2. The City Criteria Manual states that unlined open -channels may not exceed 4:1 side slopes. The report and plans show that the swale on the north side of the buildings has the left bank slope at 2:1, the maximum permissible variance is 3:1, we suggest making both sides 3:1 to take this restriction into account. Also, please compute and show a water surface profile in the report. RESPONSE: Date: cr5,.FshE t wA41ktkoFF M(W.E L-Wow Le - CM HERE IF YOU WISH TO RECENE COPIES OF REVISIONS � ��u D . ,/Flat Site--Bcab* RqW _n /Ublhl '4WZ u1 _ WS* City of of Fort Coffins I (,A'f �—�= REVISION COMMENT SHEET __- .- DATE: -June 23, 1998-DEPT:- Water/Wastewater PROJECT: #28-97 Lofts @ Campus West — (LUC) Type I PDP All comments must be received by Mike Ludwig no later than the staff review meeting: Wednesday, July 8, 1998 -Show all water/sewer mains and service on landscape plans and provide required landscape/utility separations. -Coordinate landscape design with civil design. -Place all curb stops adjacent to meter pits and provide a 4 foot separation distance from curb stop to seating walls. -Provide profile of proposed sanitary sewer main. Provide copy of easement for offsite sewer service or include easement on plat. -See landscape, site and utility plans for other comments. Date: G / 191 Signature: CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS X Plat X Site _ Drainage Report _Other X Utility X Redline Utility X Landscape h. to redlined set of the Plat, Site Plan, Landscape Plan, Plaza Detail, Building Elevations, and Lighting Plan is attached. Please make all revisions as requested and return the redlined set with plan revisions. 9. Comments and redlined utility plans from the Engineering Department are attached. Please return all redlined documents with plan revisions. 10. Comments and redlined utility plans from the Water and Wastewater Utility are attached. Please return all redlined documents with plan revisions. ---- - ----- ----------- - 11. Comments and redlined utility plans from the Stormwater Utility are attached. Please return all redlined documents with plan revisions. As you are aware, the City is implementing a new development review process. Plan revisions may now be submitted at any time. A Planning and Zoning Board date will not be assigned by City Staff until all issues have been addressed. Please contact me for the number of folded revisions required for each document prior to the submittal of plan revisions. Please submit a written response addressing each of the comments. Please contact me at 221-6206 if you have any questions or concerns related to these comments. Sincerely, N-0:4 Michael Ludwig, AICP City Planner xc: Sheri Wamhoff Stormwater Utility file/Project Planner e. If there are existing significant trees to be retained, then tree protection specifications must be added to the landscape plan pursuant to Section 3.2.1(G) of the Land Use Code. 8. The Current Planning Department offers the following comments: ✓a. Directional signage is needed for the proposed reconfiguration of the McDonald's drive thru. Please show the locations of upright (pole mounted) directional signage on the landscape plan so that any conflicts with landscaping'are-eliminated.-_ ✓b. The proposed parking east of module C does not comply with the Land Use Code. The proposed dimensions of the stalls along the north property line creates a two foot vehicle overhang into the landscape strip leaving only a 3 foot landscape buffer. A minimum five foot wide landscape strip is required along the north edge of the parking. The proposed dimensions of the stalls on the south side of the parking area creates a two foot overhang onto the sidewalk. This overhang, combined with the tree grates, and parking along the main entrance drive does not leave a 4 foot wide clear space for handicap access. Staff suggests elimination of the spaces along the north / property line. The parking along the south property line creates a 2 foot overhang over the proposed sidewalk. The western three spaces should be eliminated and an island created with pedestrian access provided to the south and east. /d. The proposed parking exceeds the required parking by 20- spaces. It appears that the additional parking is creating conflicts with sidewalks, landscaping and storm drainage. As previously stated, Staff recommends the removal of the excessive parking. e. The plaza area indicates a proposed retaining wall and fence in the. right-of- way. The applicant must submit documentation to the Engineering Department for a permit to encroach into the right-of-way and pay associated fees. The Engineering Department will review the paper work for both the wall and the fence. However,, while a fence may be allowed, it is unlikely that a retaining wall would be allowed. A fence is easier to remove / replace than a retaining wall. This issue is further complicated if there are utility easements in this area. The project signage may not be located in the right- of-way. Decreasing the size of the plaza may help. f. The trash collection areas are shown within the detention pond area and could pose health code issues. g. The proposed speed bumps are unnecessary and are causing mini -dams in the middle of the parking lot. gallons of water per minute at a residual pressure of 20 psi. Hydrants shall be of an approved type as defined by the Water Utility and the Fire Department. No commercial building can be greater than 300 feet from afire hydrant. A fire hydrant is required to be located by the entrance drive of the project for Module "C'. v1c. A turn -around is required for the proposed project. The turnaround must have an outside turning radius of forty feet or more, and an inside turning radius of twenty feet. 5. The Light and Power Utility offers the following comments: /a. It appears that the electric vault at the southeast comer of the site will need to be relocated (at the developer's expense). It may be easier and cheaper for the trash enclosure to be placed elsewhere. If the electric vault must be 1 relocated, additional easements may be required. V b. It appears that space for electric, gas, phone and cable television facilities is very limited. V C. A utility coordination meeting is needed prior to approval. The Water Conservation Specialist stated that the landscape plan shall include the total area (in square feet) for each landscape category. Landscape categories are distinguished by their water requirements and intended maintenance level. Examples of possible categories include, but are not limited to, high water turfgrass, low water turfgrass, low water planting beds, moderate water planting beds, and non -plant areas (paved areas, etc.). IJ The City Forester offers the following comments: a. Pursuant to Section 3.2.1(F) of the Land Use Code, please provide a written explanation as the why existing trees can not be saved to the extent reasonably feasible. b. Pursuant to Section 3.2.1(F) of the Land Use Code, the Site and Landscape Plans need to identify all existing significant trees with intent to remove, transplant, or protect. C. Pursuant to Section 3.2.1(F)(1) of the Land Use Code, the applicant needs to contact the City Forester to determine the number of mitigation trees required. d. Pursuant to Section 3.2.1(F)(1) a - c of the Land Use Code, the Landscape Plan must clearly designate mitigation trees and specify the size. v more stringent, the Colorado revised Statute, Title 9, Article 5, Section 111 also applies to apartment projects. Though not administered at the municipal level, similar requirements are contained in State and Federal civil rights legislation (Fair Housing Acts). Where provided in a project containing accessible dwellings, a portion of garages or covered parking must be accessible. 4 VK Accessible exterior wheelchair routes and parking facilities shall be provided with each phase of the development in accordance with Uniform Building ___.Code Chapter-_11,_Appendix Chapter.11, Division 1 and the American National Standards Institute Publication A117.1-1992 titled Accessible and Usable Buildings and Facilities. Accessible parking spaces are eight feet wide with a five feet wide adjacent access aisle. Slopes for parking and access aisle shall not exceed 1:50 in any direction. c Buildings larger than 5000 square feet shall be equipped with an automated fire suppression system throughout or compartmentalized in accordance with Uniform Building Code Section 904.1.1 as amended by the City of Fort Collins. > Buildings shall be designed to comply with the Fort Collins Energy Codes. The residential code is an amended version of the 1995 Model Energy Code and the nonresidential code is based on ASHRAE/IES (American Society of Heating, Refrigerating and Air-conditioning Engineers / Illuminating Engineering Society) 90.1-1989. 3. The Mapping Department offers the following comments: a. The'point of beginning should be shown on the Plat. ? b. The legal description starts at the northwest comer of Town Square, but it does not end at the same point. 4. The Poudre Fire Authority offers the following comments: tea. Fire apparatus access -roads shall be provided for every facility, building or portion of a building, hereafter constructed or moved into or within the jurisdiction when any portion of the facility or any potion of the exterior wall of the first story of the building is located more than 150 feet from fire apparatus access as measured by an approved route around the exterior of the building or facility. This fire land shall be submitted for approval prior to installation. Any building not meeting this criteria shall be equipped with an automated fire suppression system. All three modules are out of access, and therefore roust be equipped with an automated fire suppression system. ✓b. Fire hydrants are required with a maximum spacing of 600 feet along an approved roadway. Each hydrant must be capable of delivering 1000 Communi,y Planning and Environmental S_ vices Current Planning City of Fort Collins July 8, 1998 Timberline Property Management c/o Carl Glaser Glaser Associates Architects 215 N. Jefferson Street Fort Collins, CO 80524 Dear Carl, Staff has reviewed your revisions for the Lofts at Campus West Project Development Plan (PDP) that were submitted on June 4, 1998, and would like to offer the following comments: The Zoning Department offers the following comments: /a. Directional signage will be required for the McDonalds drive-thru lanes. Signage should not contain any McDonalds logos, etc. `yk �te�b Two trees are required along the north property line between the parking and the property line. �c. Please clarify what the "AE" designation represents. The landscape schedule key does not presently provide information regarding this designation. ✓d. The stairway at the west end of the building must be 15 feet from the City Park Avenue right-of-way line. Presently it scales to 15 feet, but the dimension should be added. 2. The Building Inspections Department offers the following comments: /a. Dwelling units accessible and adaptable for use by persons with disabilities must be provided in accordance with the 1997 Uniform Building Code as amended by the City of Fort Collins. Buildings containing four or more units in a single structure are subject to these provisions. The 1992 edition of the American National Standard Institute publication #A117.1 "Accessible and Usable Buildings and Facilities" should be used in the design of accessible/adaptable dwelling units. A local amendment to the UBC requires that accessible units with numbers of bedrooms and other amenities be provided in numbers proportionate to the remainder of the project. When 281 North College Avenue • PO. Box 580 • Fort Collins, CO 80522-0580 • (9; 0) 221-6750 • FAX (970) 416-2020