HomeMy WebLinkAbout431 E. LAUREL STREET REPLAT (ROLLINS SUB.) - PDP - 30-10 - SUBMITTAL DOCUMENTS - ROUND 1 - APPLICANT COMMUNICATIONNo Text
11. Comments A, B, C, and E noted. For comment D see attached email from
Joe Olsen that indicates that no traffic study is required, for the proposed
replat.
12. Comment noted.
13. Comments noted and design will comply. Regarding comment 13.D, with
the replat the only change in the impervious areas will be less than 5,000
square feet.
14. Comments noted.
Ted if there is any additional information that you require please let me know.
Sincerely,
Ruth Rollins
Applicant
G
Compliance with Development Standards
The City of Fort Collins has a section of the Land Use Code with specific
Development Standards for the NCM zoning District. It is important to note that
the proposed Rollins Subdivision will comply with the following standards that
address building design and height:
1) 4.8.F.i.a — orientation of exterior walls.
2) 4.8.F.1.b — primary entrance will be from Whedbee Street and will include
an architectural feature such as a front porch, landing or portico.
3) 4.8.F.i.d - if a second floor is designed it will not overhang the lower front
or side exterior walls.
4) 4.8.F.i.e - front porches shall be limited to one (1) story, and the front
facades of all one- and two-family dwellings shall be no higher than two
(2) stories.
5) 4.8.F.i.f — the project will be designed to front onto Whedbee Street.
6) 4.8.F.i.g - The minimum pitch of the roof of any building shall be 2:12 and
the maximum pitch of the roof of any building shall be 12:12. Additionally,
the roof pitch of a dormer, turret or similar architectural feature may not
exceed 24:12 and the covered porch may be flat whenever the roof of such
porch is also considered to be the floor of a second -story deck.
7) 4.8.F.2.a.i —regarding building height, the maximum building height will
be 2 stories.
Additional Response to Conceptual Review Staff Comments
Each of the comments provided in the Conceptual Review letter dated June 8,
2009 is addressed below.
1. Request for Modification of Standard described above.
2. The existing home will not exceed the maximum floor -to -area ratio. The
future residential use will be designed to accommodate the 66o feet
maximum floor area in the rear 50% of the lot.
3. The existing shed will be located 6 to 7 feet from the new lot line. This
satisfies the 5400t side yard setback.
4. The existing house will be 20 feet from the new rear lot line. This exceeds
the 15-foot rear yard setback.
5. This comment is addressed in the Contextual Setback section.
6. A Modification of Standard is requested for the parking requirements for
the existing house. See above description.
7. Any easements required to provide utility service to the existing residential
unit at 431 East Laurel Street will be provided.
8. Comment noted.
9. Comments noted.
io. Comment noted.
church functions. Residents parking on -street, using bicycles, and walking
have historically satisfied the need for parking spaces at the existing
residential unit. This demand for on -street parking has not exceeded the
supply of parking within the directly adjacent neighborhood.
Recognizing this historical condition, it is concluded.that the requirement
for parking typically found in off-street locations has been meet in a
different way that has nominal impacts within the neighborhood.
A future proposed residential unit on the new parcel would be designed to
comply with all off-street parking space requirements.
In recognizing the historical characteristics of the existing residential unit,
the conclusion is that the requested modification of the standard
application of parking requirements would be nominal and
inconsequential.
Use of Contextual Setback
Contained within the Conceptual Review staff letter was a comment on the
requirement of a 15 feet front yard and 15 feet rear yard setback. A 10 feet front
yard setback is requested. This request would comply with Section 3.8.19B of the
Land Use Code.
Section 3.8.19B states "Contextual Setbacks. Regardless of the minimum front
setback requirement imposed by the zone district standards of this Land Use
Code, applicants shall be allowed to use a "contextual"front setback. A
"contextual"front setback may fall at any point between the front setback
required in the zone district and the front setback that exists on a lot that abuts,
and is oriented to, the same street as the subject lot. If the subject lot is a corner
lot, the "contextual" setback may fall at any point between the zone district
required front setback and the front setback that exists on the lot that is
abutting and oriented to the same street as the subject lot."
The proposed subdivision is a corner lot. The lot directly south of the project,
Calvary Church, is oriented to Whedbee Street. The front of the church was
surveyed to determine the front yard setback to both the enclosed vestibule and
the main part of the building. The front yard setback to the face of the vestibule
is 4.47 feet and to the face of the main part of the building is lo.65 feet. The use
of a io feet front yard setback would be in compliance with the contextual setback
established by this adjacent parcel.
3
• The current City parking code requires 4 parking spaces for the
existing duplex.
• The modification is seeking that no parking is required for the
existing home (duplex).
Request for Modifications of Standard
The following description is provided to allow for the granting of the requests for
Modifications of Standard.
i. Modification to 4.8(D)(1). It is our understanding that this standard was
developed in an effort to minimize the residential lots, within the older
areas of Fort Collins that could subdivide. It is an overall standard that is
applied throughout Fort Collins in the NCM districts. However, within the
neighborhood surrounding the proposed project, the majority of the
"corner" lots have been subdivided.
A plan size Figure r is provided that highlights the location of the project
and each of the subdivided "corner" lots within the immediate
neighborhood. Only single lots that were subsequently divided into two,
three or four lots are included. As depicted on the figure, most of the
corner lots within the immediate area of the proposed Subdivision have
been subdivided. The parcel size of each of these nearby corner lots is
provided on Table 1. The table provides the address, parcel number and
parcel size (in square feet). The data provided on the table is grouped
together for each original corner parcel. As shown in the table, of the 56
lots 42 are less then the current minimum lot size of 5,000 sq. ft.
The proposed Rollins Subdivision as submitted with the 4,000 sq. ft.
parcel will not diverge from this standard except in a nominal way when
considered within the context of the surrounding neighborhood. The
subdivision will actually better reflect the character of the existing
neighborhood. Moreover, each of the contiguous corner parcels adjacent
to the Laurel/Whedbee intersection is subdivided.
2. Modification to Section 3.2.2(K)(1)(a). This section provides standards on
the number of off-street parking spaces that are required. Based upon the
requirements set forth in this section the existing residential unit at 481
East Laurel Street would require 3.75 parking spaces, which would result
in 4 parking spaces.
Currently there are no off-street parking spaces provided for the existing
residential unit. Our records indicate that this has been the condition for
at least the last io years. The southern area of the property was used by
the church (adjacent to the property) for parking during services and other
December 31, 2010
Mr. Ted Shepard
Planning, Development and Transportation Services
281 N. College Avenue
Fort Collins, Colorado 80522
Re: Project Description/Objectives
431 East Laurel Street — Rollins Subdivision
Dear Mr. Shepard:
The following documentation provides a description of the proposed Rollins
Subdivision, the requested Modifications of Standard, the contextual setback,
noted design compliance and additional information regarding the Conceptual
Review, Staff Comments, dated June 8, 2009.
Project Description/Objectives:
The project is for a replat/subdivision of the property located at 431 East Laurel
Street in Fort Collins, Colorado. The replat would result in a 5,000 sq. ft. lot for
the existing 431 East Laurel and a new 4,000 sq. ft. lot that would front to
Whedbee Street. It is important to note that this property is a "corner" lot located
at the southwest corner of Laurel and Whedbee Streets. It is the objective of the
Rollins Subdivision to use the new parcel for residential use. Therefore if
appropriate, the land use could be limited to residential uses.
The following two Modification of Standards are being requested as part of the
Subdivision:
1. A modification to Section 4.8(D)(i) Density/Intensity of Development.
Minimum lot area shall be the equivalent of two (2) times the total floor
area of the building(s), but not less than the following: five thousand
(5,000) square feet for a single-family or two-family dwelling and six
thousand (6,000) square feet for all other uses.
• The proposed project is requesting a new lot of 4,000 square feet.
2. A modification to Section 3.2.2(K)(1)(a) for the existing home (duplex) at
431 E Laurel. This standard requires the following minimum parking
spaces:
One or less bedrooms 1.5 spaces per unit
Two bedrooms 1.75 spaces per unit
Three bedrooms 2.0 spaces per unit.