Loading...
HomeMy WebLinkAboutPETERSON PLACE (611 S. PETERSON) - PDP - 35-00 - CORRESPONDENCE -9. Historic Preservation: a. The property is in the historic Laurel School District. b. The existing house is eligible for landmark designation. c. See section 3.4.7 of the LUC for information on historic preservation regulation that may apply. d. The new construction must be sympathetic to the existing house. e. An information packet was given out during the meeting specific to the historical status of this property. 10. Current Planning: 7 a. Refer to Section 3 (General Development Standards), and Section 4ALLMN ' Zoning District) in the Land Use Code for the standards that apply to your propose development. The Land Use Code is available to view on the internet at www.ci.fort-collins.co.us/CITY HALL; CODES. b. A five foot wide landscape strip is required between the alley right-of-way and the parking lot. c. A direct pedestrian path is required to connect the primary entrances to the 4-plex units and the street sidewalk along Peterson without requiring pedestrians to go around any buildings. d. This project may be processed as a type 1 review, or it may be reviewed as a type 2 review. The process that will be used lies in the interpretation of the Land Use Code section 4.7(B)(2)(a)(2) vs. 4.7(B)(3)(1). It seems that a type 1 review is allowed if the "dwellings are constructed on a vacant lot or parcel which did not contain a structure on October 25, 1991," whereas if that lot did contain a structure on that date, it becomes type 2. It seems it could be interpreted either way, because on the one hand, the lot that did exist on that date was not vacant; but on the other hand, the physical land area of the replatted lot would have been vacant on that date. I'm inclined to think it should be type 2 but after further discussion among staff, it may be determined that type 1 is more ap o rtate. We will determine this at t e time o ormal submittal of a eve opment review application. M 4. Water & Wastewater Utility: a. 16-inch water and 15-inch sewer in Peterson; 8-inch sewer in alley W of property. b. Each building must have separate water/sewer services. Easements will be required for the services which must cross the adjoining lot. c. If the sewer service for the SF residence connects to the sewer in the alley, relocation of that service will be required to avoid the conflict with the proposed building. d. The water conservation standards for landscape and irrigation will apply to this project, and plant investment fees and water rights will be due at time of building permit. 5. Natural Resources: a. If there are any trees that you are planning on removing, conctact Tim Buchanan, the City Forester, to determine proper mitigation. b. We ask that a single trash hauler be used to minimize traffic impacts. c. Native grasses and plant materials should be used wherever appropriate, and bluegrasses should be minimized. d. If construction lasts for more than 6 months, you will have to file a permit for fugitive dust control with Larimer County. 6. Fire Department: a. Address must be visible from Peterson Street using a minimum 6" numerals on a contrasting background. b. Due to access problems, sprinklers would be required for the 4-plex, or a 20 foot wide access off Peterson Street with turn around must be provided. c. A fire hydrant must be within 300' of every building (measured as a hose would lay) with a capacity of 1500 g.p.m @ 20 p.s.i. 7. Light and Power: a. The electric service to the existing house goes under the new location. Light and Power will relocate the service line at developer's expense. b. There is an existing transformer on the side of the apartment next door. c. Development charges apply, and would be approximately $3000 including the relocation charge. d. Contact Light and Power to coordinate a meter location. e. All power service lines must be in easements. 8. Transportation: a. Contact Eric Bracke (automobile traffic), Mark Jackson (pedestrian, bicycle, and transit), and Gayleene Rossiter (transit) to determine if a traffic impact study is needed, and what scope of information is needed. b. You will be required to provide direct bicycle and pedestrian access to Peterson Street from the rear lot. c. Bicycle parking racks are required for the 4 plex. 3 COMMENTS: 1. Zoning Department: a. If the lot is to remain as one lot, a second building on that lot would be limited to 800 square feet. b. In order to build the proposed building more than 800 square feet in size, the lot must be replatted into two lots. The lot for the existing single family house must remain at least 5000 square feet in size. c. The lot for the 4-plex must be at least 6000 square feet in size, and at least equivalent of two times the total floor area of the building. d. For each 2-bedroom unit in the 4-plex, 1.75 parking spaces are required. e. The parking space on your conceptual plan that is closest to the alley would not be allowed without a 5-foot wide landscape buffer between the alley. f. Bicycle parking must be provided for the 4-plex. g. 6% of the area of the parking lot must consist of a landscaped area. h. Height setbacks apply. 2. Stormwater Utility Department: a. This site is located in the Old Town drainage basin where the new development fee is $4,150/acre and it is subject to the runoff coefficient reduction. It is in inventory grid #8I. b. The property is in the Old Town floodplain; therefore, a floodplain use permit is required. Please contact the Floodplain Administrator Marsha Hilmes-Robinson for all the floodplain requirements. She can be reached at 224-6036. Some of the requirements are: a. No basements are allowed; b. The bottom of the crawl space must be 18 inches above the 100 year water surface elevation; c. Old Town floodplain is a "no -rise" floodplain which means a detailed HEC-2 analysis is required to show no -rise. This can be done sometimes by lowering the ground around the structure or obtaining easements from all affected properties; d. The existing structures would need to follow the substantial improvement policy if any improvements are proposed. This process is part of the floodplain use permit process. c. The standard drainage and erosion control reports and plans are required and they must be prepared by a professional engineer registered in Colorado. Onsite water quality extended detention is required. Water quantity detention is required if the imperviousness in the Old Town Master Plan is exceeded. 3. Engineering Department: a. Street Oversizing Fees are $901/unit for townhomes. Check with Matt Baker for the specific amount of this fee for your project. b. It is possible that we would require ROW and/or easement dedication along the front property line along Peterson as part of the replat. c. The alley will have to be paved and improved to Myrtle if it is not already improved. d. A traffic impact study may be required. e. You will be required to have a Development Agreement, a Development Construction Permit, and Utility Plans. I CONCEPTUAL REVIEW STAFF COMMENTS City of Fort Collins MEETING DATE: November 15, 1999 ITEM: 4-plex on the back pan of the lot at 611 S. Peterson Street APPLICANT: Bruce M. Froseth B.K. Maxwell Co. 524 Spring Canyon Ct. Fort Collins. CO 80525 LAND USE DATA: The existing lot at 611 S. Peterson is 12,000 square feet. There is existing multifamily housing to the south and west of the property. The existing house at 611 S. Peterson will remain as a single family residence. The applicant is proposing to build a rental 4-plex on the rear portion of this lot. DEPARTMENTAL CONTACTS Current Planning- Troy Jones 221-6750 Zoning Department- Jennv Nuckols 221-6760 Engineering Department- Mark McCallum 221-6605 Street Oversizing Coordinator- Matt Baker 221-6605 Poudre Fire Authority- Ron Gonzales 221-6570 Stormwater Utility- Glen Schlueter 224-6065 Water & Sewer Utilities- Roger Buffington 221-6854 Natural Resources Development Planner Kim Kreimeyer 221-6750 Licht and Power Doug Martine 221-6700 Transportation Services (ped. & transit) Kathleen Reavis 221-6608 Transportation Services (traffic) Eric Bracke 221-6608 Z Transfort (local bus service) Gaylene Rossiter 224-6195 Park Planning Janet Meisel -Burns 221-6367 Historic Preservation Karen McWilliams 224-6078 COMMUNITY PLANNING AND ENVIRONMENTAL SERVICES 281 N. College Ave. PO. Box 580 Fort Collins, CO80522-0580 (970) 221-6750 CURRENT PLANNING DEPARTMENT Commt v Planning and Environmental Current Planning City of Fort Collins Bruce M. Froseth B.K. Maxwell Co. 524 Spring Canyon Ct. Fort Collins, CO 80525 Dear Mr Froseth: rvices November 23, 1999 For your information, attached is a copy of the Staff s comments construction of a 4-plex at 611 S. Peterson presented before the Concept'aal Review Team November 15, 1999. The comments are offered informally by Staff to assist you in preparing the detailed components of the project application. Modifications and additions to these comments may be made at the time of formal review of this project. If you should have any questions regarding these comments or the next steps in the review process, please feel free to call me at 221-6206. Siricerely, Vv Triv . Jon ks City Planner cc: Eric Bracke, Streets Department Stormwater Department Project Planner File 281 North College Avenue • PO. Box 580 • Fort Collins, CO 80522-0580 • (970) 221-6750 • FAX (970) 416-2020