HomeMy WebLinkAboutREDTAIL MAJOR AMENDMENT - FDP - 26-01C - CORRESPONDENCE -.Department: Stormwater-Water-Wastewater Issue Contact: Basil Hamdan Topic: Stormwater Number: 20 Created: 5/ l/2007 [9/ 18/07] Please provide an amended drainage report with the revised pipe size calculations. [5/ 1 / 07] Please include the amended letter in the original drainage report. Original report can be retrieved from Stormwater so that no new reports have to be produced (my contribution to earth day). Please explain, in the amended letter explicitly what pipe sizes were changed from the original design in order to accommodate the increased flows. The private pipe running behind lot 6 is within a 5 foot drainage easement. This is too narrow to allow any maintenance on this pipe.. Since the pipe is shallow a minimum of a 10-foot wide easement should be provided in this case. Please extend easement to tie into row where the pipe bends to tie into the inlet on Conejos drive. Please add spot elevations in the rear of Lot 6 to ensure proper drainage is maintained. Add top and bottom of wall elevations. All sheets that are being changed should show all original information, that will remain valid after these changes as well as the new information. All changes should be bubbled. Revision block title should describe the proposed changes. City staff is ready to accept mylars for the Redtail Major Amendment documentation. However, these few current comments have to be addressed on the mylars before staff will approve and sign the plans. Be sure and return any red -lined plans you may still have when you submit the mylars. If you have any questions regarding these issues or any other issues related to this project, please feel free to call me at 221-6341. As T Olt City Planner cc: Susan Joy Basil Hamdan North Star Design King Surveyors, Inc. Planning & Zoning file #26-01B/C Page 2 STAFF PROJECT REVIEW City of Fort Collins Jon Prouty Date: 9/26/2007 Lagunitas Redtail, Inc 3944 JFK Parkway, Suite 12E Fort Collins, CO 80525 Staff has reviewed your submittal for REDTAIL MAJOR AMENDMENT - FINAL PLANS, and we offer the following comments: ISSUES: Department: Current Planning Issue Contact: Dana Leavitt Topic: Photometric Plans Number: 36 Created: 5 / 2 / 2007 [9/ 12/07] The back side shield prevents the actual light fixture from being a visual intrusion into the natural area/wetlands. After market back side shields are available and can be mounted to the pole and fixture. Again, include exterior shielding for fixtures adjacent to the natural areas and wetlands. [7/4/07] Fixture with built in house -side shield is insufficient to screen light from fixtures. If consultant does not understand comment, have them contact Dana Leavitt (224-6143) or Steve Olt (221-6341) for a complete explanation of standard as referenced below. In the luminaries schedule add descriptor for exterior house -side shield. [5/2/07] The proposed fixtures on the east and south edges of the new parking lots adjacent to the buffer areas are to be screened from the buffer area and the adjacent City -owned natural area with house -side shields. To meet the standards in 3.4.1(E)(1) of the LUC, the actual fixture is to be screened as a mitigation measure adjacent to the wetlands and natural areas. Department: Engineering Issue Contact: Susan Joy Topic: General Number: 52 Created: 9 / 6 / 2007 [9/6/07] Just need to show and label the vacated portion of the utility easement vacated by separate document on all plan sets. Please e-mail a word document of the legal description and PDF of the exhibit. I'll need a check to Larimer County for the filing fees (amount to be determined) and I'll get that recorded. Ready for mylars. Page 1