HomeMy WebLinkAboutREDTAIL RESIDENTIAL - FDP - 26-01A - SUBMITTAL DOCUMENTS - ROUND 3 - VARIANCE REQUESTSVO SNJ sm I I I E ECTRI ELECTRIC II G PHONE I I E E W CAB IE 5 1 - -APPROXIMATE LOCATION OFF W EXISTING ELECTRIC LINE - - ELEC _......_L- 'ELEC ---- —. I _.__... I z II W ELECTRIC Q •� ® �� �� ��_.. PHONE CABLE �'' W - ELEC C GAS I 0 APPROXIMATE LOCATION OF EXISTING 2" GAS LINE J I I S I I I E I I O vJ Alftl`-Q I -- — — — — — — — — — — — — — — — I q� NOTES 1. SLEEVE SIZE SHALL BE CORDINATED WITH THE UTILITY PROVIED PRIOR TO INSTALLATION. 2. GAS LINE TO BE PLACE IN SEPATATE TRENCH. ONE SLEEVE TO BE INSTALLED AT THIS LOCATION. 3. ELECTRIC, PHONE AND CABLE TO BE JOINT TRENCHED. THREE SLEEVES TO BE INSTALLED AT THESE LOCATIONS. 4. UTILITY LAYOUT PER UTILITY COORDINATION MEETING ON 2/23/05. 20 10 0 20 40 SCALE: 1- - 40• SHEET 1 OF 1 DATE: 8/10/05 UTILITY EXHIBIT VARIANCE #9 North Star ,�" design, inc. Windsor, osor,,Colors n80 5011 Phone: 970-686-6939 SCALE: 1 " = 40' DRAWN BY: TDS JOB NO.: 173-03 Fax:970-686-1188 North Star �4%ft, design, inc. August 10, 2005 Ms. Susan Joy City of Fort Collins Engineering 281 North College Avenue PO Box 580 Fort Collins, Colorado 50522-0580 Re: Redtail Request for Variance #9 — Variance to place a retaining wall in the utility easement along the west side of College Avenue. Proj: 173-03 Dear Susan: The following is a request for variance from Section 12.3.1 Utilities in the "Larimer County Urban Area Street Standards, October 1, 2002". This variance request is to allow the placement of a retaining wall within a utility easement. A utility coordination meeting was held on February 23, 2005 with the local utility providers. During that meeting it was decided that the retaining walls are acceptable within the utility easement. Conditions of acceptance included adding sleeves under the retaining wall for each of the utility providers. A joint trench will be utilized for phone, cable and electric. Gas will be placed in its own trench. The retaining walls are necessary with the current site layout to maintaining acceptable street, sidewalk and parking area slopes. The retaining wall also helps to minimizes the amount of steps required at the entry of the multi -family buildings located along Fossil Boulevard. A Sleeving Plan has been included into the Redtail construction plans with the conditions from the utility coordination meeting being met. This variance from the above standard will not be detrimental to the public health. All utilities are available to the development using typical utility installation guidelines. Issues that may compromise public safety and welfare have been addressed to the greatest extent possible. Please call with any questions or additional information that you may need for the approval of this variance. Troy Spr a P.E. ,� •., North S esign, In . FSSi.: e,'cr1G�� 700 Automation Drive, Unit I Windsor, Colorado 80550 970-686-6939 Phone • 970-686-1 1 88 Fax