Fossil Creek Parkway is classified as a collector street. Based upon
City design criteria, the design speed for a collector street is 40 mph.
it :will be posted at:30-35 mph. The corner sight distance is 400 feet in
both,directions from the intersection. This segment of. Fossil Creek
Parkway does not currently exist. However, from available plan:: and
profile drawings for this street, the corner sight distance at the proposed
access exceeds 400 feet. There appears to be a ^mound" on the west side
of Fossil Creek Parkway, just to the south of the proposed access. This
mound may need to be modified in order to have proper sight lines when the
access is built. This should be further evaluated as the site plan is
refined. The design drawing for Fossil Creek Parkway shows that the
roadway is 40 feet wide at the proposed access. This width provides for
one travel lane in each direction and 8 foot bike lanes on each side of the
street. There is no provision for a center -turn lane on Fossil Creek
Parkway. This access goes into a 137 space parking lot. No evaluation of
the need for a southbound left -turn lane on Fossil Creek Parkway has been
conducted. This evaluation would be made as part of the traffic study for
Fossil Creek Park. However, be aware that if a left -turn lane were needed
on Fossil. Creek Parkway, it would extend across the proposed bridge over
Fossil Creek. The bridge, as shown on the design drawings, is not wide
enough to accommodate the width of a center -turn lane.
TOTAL P.03
NO)-22-2eOO 14:38 r eL
MEWRANt)UH
Go
Ch
t
.�
TO: Roger Sherman, BHA Design
•' '
9'R4M: Matt Delich
C)
CO
op 'o
DATE: November 22, 2000
(�
~
�
SZISJBCT: Fossil Creek Park - Locations of proposed accesses to
•
Fossil Creek Park (File: 9994ME01)
ZO
d
LL
At your request, I evaluated the locations of the proposed
accesses to the Fossil Creek Park. The accesses are:
•
r
(O
N
1. A full -movement intersection on the west side of Lemay
>
e
Avenue, located approximately 400 feet (on -centers) south
of Muirfield way (access to Southridge Greens Golf
�j
Course).
2. A right-in/right-out intersection on the west side of
2
Lemay Avenue, located approximately 1400 feet (on-
centers) south of Muirfield Way., This provides access to
0
the park maintenance area and, as such, will not be used
N
(L
by the public.
C
N
3. A full -movement intersection on the east side of Fossil
N
Creek Parkway (future), located approximately 150 feet
south of the bridge across Fossil Creek.
Lemay Avenue is classified as an arterial street. Based upon
City design criteria, the design speed for an arterial street is 50
mph. It will be posted at 35-45 mph. The corner sight distance is
500 feet in both directions from the intersection (stopped vehicle).
From available site plans, the corner sight distance at the proposed
full -movement access to Lemay Avenue exceeds 500 feet. The crest of
the hill to the: south of this access is greater than 500 feet from
the access. It is my understanding that widening of Lemay Avenue in
this area will occur on the west side of the current Lemay Avenue
Ld
alignment. It is expected that the cross section of Lemay Avenue in
a;n
this area will be the same as the existing cross section to the
?
north. As such, there will be provision for a northbound center
w
:W
left -turn lane on Lemay Avenue approaching this access. There will
_.
not be left -turn conflicts.at any nearby intersections. The proposed
(�
location of the proposed full -movement access to Lemay Avenue is
s
W
acceptable. It is not likely that traffic signal warrants would be
J
met at the proposed full -movement access to Lemay Avenue. However,
W;z
o
at the times when there is a mass exit from a large park event, there
will be delays to traffic exiting to Lemay Avenue, particularly left
turns from the park to northbound Lemay Avenue. The average delay
•
7
can be calculated from the forecasted traffic analysis as part of the
a
traffic study for Fossil Creek Park.
BOO
fo W
The proposed right-in/right-out access is shown at/near the
W
crest of the hill on Lemay Avenue. The corner sight distance to the
'U
right (north) should be 500 feet. From available site plans, it
appears that the sight distance exceeds 500 feet. The site plan
jr—
shows some landscaping on the west side of Lemay Avenue to the north
Q
:~
of the proposed access. This location and size of the landscaping
should be evaluated in greater detail as the site plan is refined.