Department: Water Conservation
Contact: Eric Olson, 970-221-6704,
Topic: General
Comment Number: 1
eolson@fcgov.com
Comment Originated: 06/14/2016
06/14/2016: Irrigation plans are required no later than at the time of building
permit. The irrigation plans must comply with the provisions outlined in Section
3.2.1(J) of the Land Use Code. Direct questions concerning irrigation
requirements to Eric Olson, at 221-6704 or eolson@fcgov.com
Department: Water -Wastewater Engineering
Contact: Wes Lamarque, 970-416-2418, wlamargue@fcqov.com
Topic: General
Comment Number: 1
Comment Originated: 06/08/2016
06/08/2016: The utility plans are difficult to determine what is existing and
proposed. Please clarify with line types what is existing and proposed.
Comment Number: 2 Comment Originated: 06/08/2016
06/08/2016: The proposed public sewer main is roughly 12 feet from the north
easement line where 15 feet is required. Please revise the sewer layout to
provide 15 feet to the edge of the easement while maintaining 10 feet of
separation from the water line.
Comment Number: 3 Comment Originated: 06/08/2016
06/08/2016: Please show the curb stops and the meter pits for all the water
services on the Utility Plan.
Department: Zoning
Contact: Ali van Deutekom, 970-416-2743, avandeutekom@fcgov.com
Topic: General
Comment Number: 1 Comment Originated: 06/14/2016
The concept of two-family attached dwellings require that each owner pay the
capital expansion fees associated with a two family dwelling whether they use it
as two units or not. Please include this information when talking with potential
owners. This could be 10,000-20,000 in extra fees.
Comment Number: 1 Comment Originated: 06/14/2016
06/14/2016: Accessory studio units should be called studio dwelling units.
Comment Number: 1 Comment Originated: 06/14/2016
06/14/2016: What is the purpose of the community office? What happens to the
office when the lots are sold?
14
Comment Numb`` 6
lRt,mment Originated: 06/15/2016
06/15/2016: Please label the bearings on the boundary in a clockwise
direction. See redlines.
Comment Number: 7
Comment Originated: 06/15/2016
06/15/2016: Please make note of the discrepancies in the Boundary Line
Curve/Line Data Table. See redlines.
Comment Number: 8 Comment Originated: 06/15/2016
06/15/2016: Please define "RB" in the legend. See redlines.
Comment Number: 9
Comment Originated: 06/15/2016
06/15/2016: Please add bearings, distances, and/or curve data as marked.
See redlines.
Comment Number: 10
Comment Originated: 06/15/2016
06/15/2016: The plat needs a note explaining the 2 found pins for curve C2.
The Old Town North plat does not show this curve. See redlines.
Comment Number: 11 Comment Originated: 06/15/2016
06/15/2016: What is the 60' Easement per Book 2222 Page 2082 for, and who
is it dedicated to?
Comment Number: 12 Comment Originated: 06/15/2016
06/15/2016: There is text that needs to be rotated 180 degrees. See redlines.
Comment Number: 13
Comment Originated: 06/15/2016
06/15/2016: Curve C418 is missing from the Boundary Line Curve/Line Data
Table. See redlines.
Topic: Site Plan
Comment Number: 14
Comment Originated: 06/15/2016
06/15/2016: The title on all sheets needs to match the Subdivision Plat. See
redlines.
Comment Number: 15 Comment Originated: 06/15/2016
06/15/2016: Please make corrections to the legal description. See redlines.
Comment Number: 16 Comment Originated: 06/15/2016
06/15/2016: Please make corrections to the sheet index. See redlines.
Department: Traffic Operation
Contact: Nicole Hahn, 970-221-6820, nhahn@fcgov.com
Topic: General
Comment Number: 1
Comment Originated: 06/14/2016
06/14/2016: Comment pending further discussion -The current width of
Osiander Street can not functionally handle the on street parking and two way
traffic. There are a number of ways to modify the operations of the parking and
traffic to create a functional solution. Some ideas include:
1.) No on street parking, 2-way travel
2.) Parking on one side, 1 way travel
3.) Widen the section to accommodate parking on one or both sides and
two-way travel.
13
IF NGVD29 UNOUSTED DATUM IS REQUIRED FOR ANORPOSE,
THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED
= NAVD88 - X.XX'.
Comment Number: 22 Comment Originated: 06/15/2016
06/15/2016: All benchmark statements must match on all sheets.
Comment Number: 23
Comment Originated: 06/15/2016
06/15/2016: Why is the Basis Of Bearings statement different from the
Subdivision Plat?
Comment Number: 24
Comment Originated: 06/15/2016
06/15/2016: There are line over text issues. See redlines. The sheets marked
are just showing examples of the issues. Please correct all issues throughout
the plan set.
Comment Number: 25
Comment Originated: 06/15/2016
06/15/2016: There are text over text issues. See redlines. The sheets marked
are just showing examples of the issues. Please correct all issues throughout
the plan set.
Comment Number: 26 Comment Originated: 06/15/2016
06/15/2016: There is text that needs to be masked. Mask all text in hatched
areas. See redlines. The sheets marked are just showing examples of the
issues. Please correct all issues throughout the plan set.
Topic: Landscape Plans
Comment Number: 17
Comment Originated: 06/15/2016
06/15/2016: The title on all sheets needs to match the Subdivision Plat. See
redlines.
Topic: Lighting Plan
Comment Number: 18 Comment Originated:
06/15/2016
06/15/2016: The title needs to match the Subdivision Plat. See redlines.
Topic: Plat
Comment Number: 1 Comment Originated:
06/15/2016
06/15/2016: Please make corrections to the sub -title as marked. See redlines.
Comment Number: 2 Comment Originated:
06/15/2016
06/15/2016: Please provide current acceptable monument records for the
aliquot corners shown. These should be emailed directly to Jeff at
jcounty@fcgov.com
Comment Number: 3 Comment Originated:
06/15/2016
06/15/2016: Please show who owns & maintains the Tracts. See redlines.
Comment Number: 4
Comment Originated: 06/15/2016
06/15/2016: Please check the area in the Statement Of Ownership And
Subdivision. See redlines.
Comment Number: 5
Comment Originated: 06/15/2016
06/15/2016: Please add dedication information for all street rights of way. See
redlines.
12
Comment Numbt 5 IRmment Originated: 06/08/2016
06/08/2016: The drainage report discusses that the SWMM model produced
with this report for the 36-inch storm sewer under Suniga Dr. does not include
the original planned flows to the west. The model needs to include all flows that
are currently planned to flow into this storm sewer and the additional flows of this
development, including the swale just south of Suniga Road. Please revise the
SWMM model.
Additional conveyance may be required to convey the flows from this
development to the regional detention pond.
Comment Number: 6 Comment Originated: 06/08/2016
06/08/2016: The design information for the NECCO 36-inch storm sewer plan
and profile needs to be from the as -built drawings. Please clarify what
information is currently shown.
Comment Number: 7
Comment Originated: 06/08/2016
06/08/2016: The Low Impact Development standards are required for this
development per the Conceptual Review comments. Please reference these
comments for details.
Comment Number: 10
Comment Originated: 06/14/2016
06/14/2016: There may be more comments forthcoming upon further review of
the plans associated with this project.
Department: Technical Services
Contact: Jeff County, 970-221-6588, icounty@fcgov.com
Topic: Building Elevations
Comment Number: 19 Comment Originated: 06/15/2016
06/15/2016: The title needs to match the Subdivision Plat. See redlines.
Topic: Construction Drawings
Comment Number: 20 Comment Originated:
06/15/2016: Please make corrections to the sub -title as marked. See redlines.
Comment Number: 21 Comment Originated:
06/15/2016: Please provide the following information for the Benchmark
Statement in the EXACT format shown below.
PROJECT DATUM: NAVD88
BENCHMARK # w/ DESCRIPTION
ELEVATION:
BENCHMARK # w/ DESCRIPTION
ELEVATION:
PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL
DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29
UNADJUSTED FOR THEIR VERTICAL DATUMS.
06/15/2016
06/15/2016
11
Department: Stormwaterfogineering •
Contact: Jesse Schlam, 970-218-2932, jschlam@fcqov.com
Topic: Erosion Control
Comment Number: 1
Comment Originated: 06/03/2016
06/03/2016: Erosion Control Material for this site is based off the old
standards, therefore Erosion and Sediment Control Materials need to be
submitted for FDP. The erosion control requirements are in the Stormwater
Design Criteria under the Amendments of Volume 3 Chapter 7 Section 1.3.3.
and can be found at www.fcgov.com/erosion . See redlines for corrections in
the Erosion Control Plan. The Erosion Control Report (Stormwater
Management Control) submitted was incomplete and not current neither for City
Erosion Control Requirements nor for State SWMP requirements. The Site will
also have to supply an Erosion Control Escrow Calculations based on the
correct calculation method. If you need clarification concerning the erosion
control section, or if there are any questions please contact Jesse Schlam
970-218-2932 or email @ jschlam@fcgov.com
Contact: Mark Taylor, 970-416-2494, mtaylor@fcqov.com
Topic: Floodplain
Comment Number: 9
Comment Originated: 06/14/2016
06/14/2016: Add notes to the appropriate pages stating that an approved
floodplain use permit prior to beginning any work proposed within the existing
floodplain.
Topic: General
Comment Number: 8
Comment Originated: 06/14/2016
06/14/2016: It is difficult to decipher what is proposed and what is existing.
Please do a better job of differentiating.
Contact: Wes Lamarque, 970-416-2418, wlamargue@fcqov.com
Topic: General
Comment Number: 2
Comment Originated: 06/08/2016
06/08/2016: The Grading plan is difficult to read and hard to depict flow
patterns. The city suggests a 1 inch = 30 ft scale.
Comment Number: 3 Comment Originated: 06/08/2016
06/08/2016: The F.F. elevations are required for all the proposed structures.
Also, the lot corner elevations are not labeled on the furthest northern lots.
Comment Number: 4 Comment Originated: 06/08/2016
06/08/2016: The conveyance for basins 4,5,6 & 9 after flows leave the parking
areas is not depicted on the grading or drainage plan. Please show on the
plans how flows will leave the hard surface and enter the swale. Please label
any curb cuts, inlets, etc. and show the proposed conveyance through the
proposed sidewalk.
10
Comment Numb(` 7 IRmment Originated:
06/15/2016
06/15/2016: For the single family detached elevations, there is no scale. But it
appears that houses are exceptionally narrow. Please note that on a 35-foot
wide lot, minus the two 5-foot wide sideyard setbacks, there remains 25 feet of
lot width for a building envelope. The elevations appear as if the width of the
houses is considerably less than 25 feet. The applicant is encouraged to take
advantage of the parking being in the alley and make the front porches as wide
as the house.
Comment Number: 8 Comment Originated:
06/15/2016: For the two-family attached dwellings, Staff appreciates the effort
to provide two building styles. Please indicate on the site plan how these two
styles are distributed. In order to mitigate the potential of the alley becoming
overly repetitive, Staff encourages the design team to consider either
introducing and additional building style or further individualizing the Unit A
entrances so that there is a greater degree of distinctiveness among the 24
entrances divided among the 12 buildings.
Comment Number: 9
06/15/2016
Comment Originated: 06/15/2016
06/15/2016: Since Unit A does not really have any available and functional
outdoor space, please provide a dimension for the second floor balconies and
decks.
Comment Number: 10 Comment Originated:, 06/15/2016
06/15/2016: For readability, please remove contour lines from the site plan.
Comment Number: 11 Comment Originated: 06/15/2016
06/15/2016: On the Lighting Plan, by using only five fixtures, there appears to
be excessive illumination in close proximity to each fixture which overly impacts
the adjoining dwellings. Perhaps using additional fixtures, but at lower lumens,
these hot spots could be eliminated. Perhaps the parking lot light fixtures could
be eliminated with illumination being provided by building -mounted lighting.
Comment Number: 12
Comment Originated: 06/15/2016
06/15/2016: If the public alley is to be named, please be sure that the name is
not a duplicate or phonetic sound -alike with any existing name within the
boundary of the Larimer Emergency Telephone Authority. Here is the link to the
Larimer County list of existing street names: http://www.larimer.org/streets/
Comment Number: 13 Comment Originated: 06/17/2016
06/17/2016: A meeting was held on June 17, 2016 with City Staff from Traffic
Operations, Engineering and Planning to discuss issues related to adding new
housing on the north side of Osiander given the existing width of Osiander. At
this meeting, it was determined that the applicant will provide a series of
pull-outs on the north side of Osiander to provide a widening in case two cars
passing each other, with a parked car on the south side of Osiander, do not feel
comfortable passing and need extra room. The applicant agreed to provide a
schematic design for Staff review in advance of the second round submittal.
0
Department: Planning Aces •
Contact: Ted Shepard, 970-221-6343, tshepard@fcgov.com
Topic: General
Comment Number: 1 Comment Originated: 06/15/2016
06/15/2016: For the two-family attached dwellings, the site plan does not seem
to match the plat. Where the site plan shows a space between each pair of two
family attached buildings, the plan shows no such separation. The documents
need to fully describe and explain the ownership arrangement of this space.
The site plan indicates this space to be common area with a walkway but the
plat indicates that this space would be divided equally between the two
adjoining lots. If the arrangement shown on the plat is to prevail, how is the
space between buildings to be established and maintained? One option would
be to dedicate on the plat a five-foot access easement on each side of the
property line within which the connecting walkway would be constructed. Notes
on both the Plat and Site Plan would be needed to state the purpose of the
easement, the extent of the sidewalk, and the long term maintenance
responsibilities.
Comment Number: 2
Comment Originated: 06/15/2016
06/15/2016: The site plan indicates that the easterly four parcels are to be part
of a future development but the plat calls out these lots to be Lots 29 — 32.
Please reconcile.
Comment Number: 3
Comment Originated: 06/15/2016
06/15/2016: For the two-family attached dwellings, the plan view typical on the
site plan does not match the architectural elevations. The site plan typical
indicates that the entrance to the ground floor studio unit B is on the side of the
building. But, the elevations indicate that the entrance is on the �front� which I
take to mean 6north.� In order to strengthen the building -to -street relationship,
and to tie the entrance to the connecting walkway out to Suniga, staff prefers the
arrangement indicated on the architectural elevations. Or, if two entrances are
intended, please indicate. In any event, please reconcile.
Comment Number: 4 Comment Originated: 06/15/2016
06/15/2016: For the two-family attached dwellings, the walkways between
buildings are lost in all the linework on both the site and landscape plans.
Please expand the plan view typical on the site plan to show the location and
width of this walkway.
Comment Number: 5
Comment Originated: 06/15/2016
06/15/2016: Please re -label the out -building as a community building or
community clubhouse.
Comment Number: 6
Comment Originated: 06/15/2016
06/15/2016: For the single family detached, side yard fencing, please add a
standard note on the site plan and a typical on the architectural elevations that
indicates that the street -facing fencing located just behind the front building line
will be a common design for ten feet in length for two lots versus individual
designs five feet in length on an individual lot basis. This will emulate the
treatment on the existing lots across the street.
a
Comment Numb 3
9mment Originated: 06/10/2016
06/10/2016: Contact Light and Power Engineering to coordinate the
transformer and electric meter locations, please show the locations on the utility
plans.
Comment Number: 4 Comment Originated: 06/10/2016
06/10/2016: Streetlights will be placed along public streets. A 40 feet
separation on both sides of the light is required between canopy trees and
streetlights. A 15 feet separation on both sides of the light is required between
ornamental trees and streetlights.
Comment Number: 5
Comment Originated: 06/10/2016
06/10/2016: The location of the water and electric services will need to be
coordinated with Light and Power Engineering.
Comment Number: 6
Comment Originated: 06/10/2016
06/10/2016: Please contact Light & Power Engineering if you have any
questions at 221-6700. Please reference our policies, development charge
processes, and use our fee estimator at
http://www.fcgov.com/utilities/business/builders-and-developers.
Department: PFA
Contact: Jim Lynxwiler, 970-416-2869, ilynxwiler@poudre-fire.org
Topic: General
Comment Number: 1
Comment Originated: 06/09/2016
06/09/2016: HYDRANTS
Hydrant number and placement exceeds minimum standards. The project may
continue as currently planned or decrease by two hydrants as per redlines.
Code language provided below.
> IFC 508.1 and Appendix B: RESIDENTIAL REQUIREMENTS: Within the
Urban Growth Area, hydrants to provide 1,000 gpm at 20 psi residual pressure,
spaced not further than 400 feet to the building, on 800-foot centers thereafter.
Comment Number: 2 Comment Originated: 06/09/2016
06/09/2016: PREMISE IDENTIFICATION
Some concerns still remain with regard to wayfinding.
> All entrances to alley should be posted with "Vehicle Access to Residences
on Suniga Road" along with hundred block numbers as applicable.
> Addressing of Suniga Road residences (odd no's lots) are proposed to be
posted on both front and alley side to alleviate any confusion. PFA approves
this plan.
> In addition, addressing of Osiander Street residences (even no's lots) should
also be posted on both front and alley side to alleviate confusion.
> Other issues need to be resolved with addressing if the alley is to be named.
> Further discussion is required.
Comment Number: 3
Comment Originated: 06/09/2016
06/09/2016: NO PARKING IN ALLEYS
PFA is seeking verification that no parking is being proposed along the length
of the public alley. No parking signs locations should be labeled on the plans.
7
Construction soomply with the following adopted codes a0ended
2012 International Building Code (IBC)
2012 International Residential Code (IRC)
2012 International Energy Conservation Code (IECC)
2012 International Mechanical Code (IMC)
2012 International Fuel Gas Code (IFGC)
2012 International Plumbing Code (IPC) as amended by the State of Colorado
2014 National Electrical Code (NEC) as amended by the State of Colorado
Fort Collins has amendments to most of the codes listed above. See the
fcgov.com web page to view them.
Accessibility: State Law CRS 9-5 & ICC/ANSI A117.1-2009.
Snow Load Live Load: 30 PSF / Ground Snow Load 30 PSF.
Frost Depth: 30 inches.
Wind Load: 100- MPH 3 Second Gust Exposure B.
Seismic Design: Category B.
Climate Zone: Zone 5
Energy Code Use
1. Single Family; Duplex; Townhomes: 2012 IRC Chapter 11 or 2012 IECC.
2. Multi -family and Condominiums 3 stories max: 2012 IECC residential
chapter.
3. Commercial and Multi -family 4 stories and taller: 2012 IECC commercial
chapter.
Old town north 3rd — project specific concerns:
1. Fire -sprinkler systems are required for townhomes and duplexes.
2.3. All windows above the 1 st floor require minimum sill height of 24"
3. Building code and State statute CRS 9-5 requires project provide accessible
units.
4. Upgraded insulation is required for buildings using electric heat or cooling.
5.7. Low -flow Watersense plumbing fixtures (toilet, faucets, shower heads) are
required.
6. Special combustion safety requirements for natural draft gas appliances.
7. Low VOC interior finishes.
Department: Light And Power
Contact: Coy Althoff, CAlthoff@fcgov.com
Topic: General
Comment Number: 1 Comment Originated: 06/10/2016
06/10/2016: Single phase electric facilities exist along the N. side of Osiander
St. and also dead -ended at the end of Blodel St.
Comment Number: 2
Comment Originated: 06/10/2016
06/10/2016: Development charges, electric Capacity Fee, Building Site
charges and any system modification charges necessary will apply to this
development.
n.
Comment Numb' 34 11mment Originated: 06/15/2016
06/15/2016: 34. See plans for additional comments.
Department: Environmental Planning
Contact: Rebecca Everette, 970-416-2625, reverette@fcqov.com
Topic: General
Comment Number: 1 Comment Originated: 06/14/2016
06/14/2016: City Code and the Land Use Code require that any prairie dogs
inhabiting a site must be humanely eradicated (see Section 3.4.1(N)(6) of the
Land Use Code). A prairie dog removal plan will need to be provided at the
time of Final Plans, and documentation of the removal activities should be
provided prior to the issuance of a Development Construction Permit.
Additionally, should this project gain approval and proceed to construction, a
burrowing owl survey, in accordance with the Division of Parks and Wildlife
standards, shall be conducted prior to construction by a professional, qualified
wildlife biologist.
Topic: Landscape Plans
Comment Number: 2 Comment Originated: 06/14/2016
06/14/2016: 1 appreciate the attention to the seed mixes. Both the water quality
and native seed mixes include a nice variety of native species that are well
suited to this area. Thank you!
Comment Number: 3 Comment Originated: 06/14/2016
06/14/2016: 1 will review the detailed planting plan for the shrub/perennial areas
when it is provided - final plan is OK for Environmental Planning.
Department: Internal Services
Contact: Russell Hovland, 970-416-2341, rhovland@fcgov.com
Topic: Building Insp Plan Review
Comment Number: 1 Comment Originated: 06/15/2016
06/15/2016:
Building Permit Pre -Submittal Meeting:
Pre -Submittal meetings are required to assist the designer/builder by assuring,
early on in the design,
that the new commercial or multi -family projects are on track to complying with
all of the adopted City
codes and Standards listed below. The proposed project should be in the early
to mid -design stage for
this meeting to be effective and is typically scheduled after the Current Planning
conceptual review
meeting. Applicants of new commercial or multi -family projects are advised to
call 416-2341 to schedule
a pre -submittal meeting. Applicants should be prepared to present site plans,
floor plans, and elevations
and be able to discuss code issues of occupancy, square footage and type of
construction being proposed.
5
Comment NumPer: 25 41omment Originated: 06/15/2016
06/15/2016: 25. The alley sections — For drainage to one side — need to show
that the roll curb is located within the alley section. This means that the drive
able surface width will be reduced by 17 inches. Also need to show the 1 foot
by 1 foot concrete edge on the other side. You also show an alley section that is
proposed to have the center pan — how do you propose that these two sections
work together. Also by doing this all alleys will have to be constructed fully in
concrete. Also the alley section with the center pan is showing it too deep and
exceeding the 2% cross slope.
Comment Number: 26
Comment Originated: 06/15/2016
06/15/2016: 26. Pavement sections are not to be shown on the plans.
Pavement design is based on the final soils report which is done after all the
utilities are installed and the grading completed. It is at that time that a
pavement design can be proposed, reviewed and approved based on the
existing soil conditions.
Comment Number: 27 Comment Originated:
06/15/2016: 27. The plans need to provide curve and design information for
the alleys so it can be reviewed and make sure that meets standards and can
be navigated by PFA trucks.
Comment Number: 28 Comment Originated:
06/15/2016: 28. The driveways into the parking lots need to be built per detail
706.2 with the flare in order for the sidewalks to meet ADA standards.
06/15/2016
06/15/2016
Comment Number: 29 Comment Originated: 06/15/2016
06/15/2016: 29. Reminder minimum flowline grade is .5% and that is what is
required going into a low point in the street or alley.
Comment Number: 30
Comment Originated: 06/15/2016
06/15/2016: 30. For the head in parking areas that are off the side of the alley
that has the roll curb — need to show that curb extending across the parking
area.
Comment Number: 31
Comment Originated: 06/15/2016
06/15/2016: 31. The intersection detail will be checked when full profiles are
provided. Transition lengths will need to be labeled on the intersection details.
Will need intersection details for the street/ alley and alley/alley intersections as
well.
Comment Number: 32 Comment Originated:
06/15/2016: 32. Based on the plans right now the following additional details
are needed: 702 — roll curb for alley section, 1202, 1201, 1606a, 706.2,
sidewalk chase — if in City ROW City detail must be used - if on private
property you can use D-11 or create your own detail.
Comment Number: 33 Comment Originated:
06/15/2016: 33. The site has shallow water — Please know that sump pumps
can only be tied into an approved drainage facility and cannot be drained out
across sidewalks or into the curb and gutter or into the streets/ alleys. A
paragraph will be added into the development agreement giving builders and
property owners notice of this. This needs to accounted for in your design and
plans.
06/15/2016
06/15/2016
a
Comment Numb' 15 9mment Originated: 06/15/2016
06/15/2016: 15. The following notes need to be added to the site plan: 1)
Fences, Garages and all other structures shall be setback a minimum of 8 feet
from alley rights -of -way. 2) Driveway flares shall comply with eh City of Fort
Collins Engineering Design Standards. See Engineering Drawings.
Comment Number: 16 Comment Originated: 06/15/2016
06/15/2016: 16. The radii at the alley entrances are to be 5 feet.
Comment Number: 17 Comment Originated: 06/15/2016
06/15/2016: 17. If the topo survey is to be a part of the utility plan set then it
needs to have a signature block added to it.
Comment Number: 18 Comment Originated: 06/15/2016
06/15/2016: 18. General Note #41 — you need to identify if the stationing is to
be based on Centerline or Flowline of the roads. I will need this information in
order to be able to review the profiles once they are provided.
Comment Number: 19
Comment Originated: 06/15/2016
06/15/2016: 19. Line weights need to be adjusted so we can tell what is
existing and what is proposed. No way to tell looking at it now.
Comment Number: 20
Comment Originated: 06/15/2016
06/15/2016: 20. The ramps at the NE corner of Blondel and Osiander need to
be updated to directional ramps. This needs to be shown on the plans.
Comment Number: 21 Comment Originated: 06/15/2016
06/15/2016: 21. Any utilities to the community office? Currently there are no
services shown.
Comment Number: 22
Comment Originated: 06/15/2016
06/15/2016: 22. IF the sidewalk along Redwood Street adjacent to this
property isn't already installed it will need to be installed with this project.
Comment Number: 23 Comment Originated: 06/15/2016
06/15/2016: 23. Per the City's driveway details the drainage as you have
shown it going into the parking lots off of the alley will not work as the area will
slope back into the alley rather than into the parking lot. Probably need to do a
driveway chase in these areas in order to get the drainage to the north, provide
the driveway requirements and meet ADA requirements on the sidewalk you
have planned along here.
Comment Number: 24
Comment Originated: 06/15/2016
06/15/2016: 24. The cross section for Osiander Street needs to be changed —
if parking does remain on only one side of the roadway it will be on the south
side — not the north as you show.
3
Comment Nume€r: 4
q0mment Originated: 06/15/2016
06/15/2016: 4. The TDRFees did not include the community building — is it a
1,000 sq ft or 2,000 sq ft? not sure since the plan says 1,000, but also says 2
story. Nor did the fees include the extra 4 lots included in the plat. If they are to
be included in the project the fees are due for these lots as well.
Comment Number: 5 Comment Originated: 06/15/2016
06/15/2016: 5. Plat — the planning approval language is old.
Comment Number: 6 Comment Originated: 06/15/2016
06/15/2016: 6. Plat - need to identify who will own and maintain the tracts.
Comment Number: 7 Comment Originated: 06/15/2016
06/15/2016: 7. Plat - Need to address the vacation of the existing easements
on the property.
Comment Number: 8
Comment Originated: 06/15/2016
06/15/2016: 8. Plat - does the alley need to be named?? If so that needs to
be included on the plat.
Comment Number: 9
Comment Originated: 06/15/2016
06/15/2016: 9. Ten foot by ten foot ROW corners need to be provided at the
intersection of each alley and street and alley and alley intersection.
Comment Number: 10 Comment Originated: 06/15/2016
06/15/2016: 10. Per the plans there is a portion of the alley that curves across
Tract D and that needs to be in ROW as well.
Comment Number: 11
Comment Originated: 06/15/2016
06/15/2016: 11. The alleys at the east end of the property do not meet
separation requirements. The new alleys need to align with the alleys across
the street or they need to meet separation distances.
Comment Number: 12 Comment Originated: 06/15/2016
06/15/2016: 12. For the future lots — they either need to be included in the
plans or not included in the plans. If you wish to plat and plan these lots then
they need to be shown as a part of the site, landscape, utility plans and be
approved. They can be a phase 2, but will be subject to the vesting limitations.
Either they are a part of the approval or they are not — it can't be both.
Comment Number: 13 Comment Originated:
06/15/2016: 13. 1 don't know that a 12 foot wide alley for two way traffic will be
acceptable. It is something that will need to be looked at and discussed if you
wish to propose that.
Comment Number: 14 Comment Originated:
06/15/2016: 14. If the Osiander solution is one in which there is only parking on
the south side of the street then no parking signs need to be shown to be
installed along the north side of the street and this note needs to be added to
the site plan. On street parking is to occur on the southern side of Osiander
Street only. No parking signs will be placed at a minimum of 250 foot intervals
along the north side of the road.
06/15/2016
06/15/2016
2
•
City of
Fort Collins
June 17, 2016
Terry Palmos
Greeley Associates
419 Canyon Ave #200
Fort Collins, CO 80521
RE: Old Town North 3rd Filing, PDP160017, Round Number 1
Community Development and
Neighborhood Services
281 North College Avenue
PO Box 580
Fort Collins, CO 80522
970.221.6750
970.224.6134 - fax
tcgov. com/developmentreview
Please see the following summary of comments from City staff and outside reviewing
agencies for your submittal of the above referenced project. If you have questions about
any comments, you may contact the individual commenter or direct your questions through
the Project Planner, Ted Shepard, at 970-221-6343 or tshepard@fcgov.com.
Comment Summary:
Department: Engineering Development Review
Contact: Sheri Langenberger, 970-221-6573, slangenberger@fcqov.com
Topic: General
Comment Number: 1
Comment Originated: 06/15/2016
06/15/2016: 1. Osiander — It doesn't work as is with parking on one side and
two way traffic. Here area few options that we have identified that might work:
1) remove parking - no parking on either side of Osiander and allow 2-way
traffic. 2) keep parking on the south side of the road and restrict the roadway to
one-way traffic. 3) widen the roadway by 4 feet - this would allow parking on the
south side and two way traffic. 4) widen the roadway by 12 feet - this would
allow parking on both sides of the road and two way traffic. One or more of
these ideas or solutions will impact the neighborhood and will require
coordination with and input from the rest of the neighborhood. These options
need to be considered and then come back with your proposal and ideas.
Comment Number: 2
Comment Originated: 06/15/2016
06/15/2016: 2. The community building is not shown on the plat. As currently
shown that area is a blanket easement and no BP for this structure could be
issued.
Comment Number: 3 Comment Originated: 06/15/2016
06/15/2016: 3. The community building was not included as a use in the
traffic study.