Loading...
HomeMy WebLinkAboutKMART PLAZA, FULLER'S TEXACO - PDP - 38-97A - CORRESPONDENCE - REVISIONS (3)Transportation Planning Dept. I ] We will provide pedestrian walkway to existing retail shop north of subject property. 2] Bike parking for 5 bikes is provided just west of the Texaco building. 3] Transit stop on Drake will be planned for with additional paving as shown on revised plan. Traffic Operations 1 ] We understand the comment re: access on Drake Road. Please review the timeframe. 10. Current Planning a] General note on lighting will be added to drawings New photometric plan is submitted as part of these revisions. b] Details of pole light is included. c] Lights are shown on the site/landscape plan.. d] Foundation plantings are added as requested. e] 30" Hedge planting has been added to replace the [e] junipers. as per discussions with staff. f] The Jiffy Lube site is not included as part of this PDP and has been so noted and treated on the drawings. g] Landscape plan is labeled and sheet numbers have been added. h] Pedestrian crossings have been included at both access points. i] Three parking spaces have been eliminated per discussions with staff. j] A direct pedestrian connection has been provided as requested from Drake road through both sites. k] Bike parking is shown just west of the Texaco building. 1] Further discussions with staff, together with additional pedestrian connections, does not necessitate the reverse layout plan approach. m] A pedestrian crossing sign has been added at the exit of the car wash per discussions with staff. n] ok o] ok p] ok q] ok r] ok s] ok t] More canopy trees have been added per comment. u] Trash area has been screened with additional planting. v] Detail of trash enclosure is included. w] Color sample has been included. Brick color has been redefined. x] ok y] ok 11. Advanced Planning Dept. a], b] The Site Plan is submitted in accordance with further discussions with staff. Sincerely, Carr Bieker Carr Bieker Glenn Konen Donald Bundy June 5. 1998 TO: Leanne A. Harter, AICP, City Planner FROM: The Architects' Studio, Carr Bieker RE: Written response to Staff Comments on Kmart Plaza, Fuller Texeco PDP, #38-97. The following is a response to the items listed in your April 3, 1998 letter: 1. Zoning Dept. a} ok b} We discussed this further with Planners and jointly agreed a centrally located enclosure was desirable. c] ok 2. Building Inspections Comments understood and accepted. 3. Poudre Fire Authority There is an existing fire hydrant located in an planting island near the southeast comer of the Kmart building, it is within approximately 170' of the southeast corner of the Texaco building, well within the 300' criteria. ♦ Other comment understood and accepted. 4. Water Conservation Comments understood and accepted. 5. Engineering Dept. See response by Stewart Engineering. 6. Stormwater Utility See response by Stewart Engineering. 7. Water/Wastewater Utility Comments re: landscape plan coordination with utility separations completed. See response by Stewart Engineering. Architecture Planning 151 West Mountain Avenue Fort Collins, Colorado 80524 970-482-8125 FAX 970-482-8450