Loading...
HomeMy WebLinkAboutMAGNOLIA/WHEDBEE REPLAT - PDP/FDP - FDP150032 - CORRESPONDENCE - (3)Neighborhood Meeting . e a great way to get public feedback and jid potential hiccups that may occur later in the review process. 6. Please see the Development Review Guide at www.fcgov.com/drg. This online guide features a color coded flowchart with comprehensive, easy to read information on each step in the process. This guide includes links to just about every resource you need during development review. 7. This development proposal will be subject to all applicable standards of the Fort Collins Land Use Code (LUC), including Article 3 General Development Standards. The entire LUC is available for your review on the web at http://www.colocode.com/ftcollins/landuse/begin.htm. 8. If this proposal is unable to satisfy any of the requirements set forth in the LUC, a Modification of Standard Request will need to be submitted with your formal development proposal. Please see Section 2.8.2 of the LUC for more information on criteria to apply for a Modification of Standard. 9. Please see the Submittal Requirements and Checklist at. http://www.fcgov.com/developmentreview/applications.php, 10. The request will be subject to the Development Review Fee Schedule that is available in the Community Development and Neighborhood Services office. The fees are due at the time of submittal of the required documents for the appropriate development review process by City staff and affected outside reviewing agencies. Also, the required Transportation Development Review Fee must be paid at time of submittal. 11. When you are ready to submit your formal plans, please make an appointment with Community Development and Neighborhood Services at (970)221-6750. a review of the trees sl, oe conducted with Tim Buchanan, City FC, ,(er (221 6361) to determine the status of the existing trees and any mitigation requirements that could result from the proposed development. Department: Engineering Development Review Contact: Sheri Langenberger, 970.221 6573, slangenberger(a�fcgov.com 1. The City's Transportation Development Review Fee (TDRF) is due at the time of submittal. For additional information on these fees, please see: http://www.fcgov,com/engineering/dev-review.php 2. This project is responsible for dedicating any easements that are necessary for this project. 3. The replat will need to be prepared by a Colorado licensed surveyor and meet the City standards and requirements for a plat. Department: Electric Engineering Contact: Coy Althoff, , CAlthoff(cDfcgov.com 1. If the 404 Whedbee lot is split up, it may be necessary to dedicate a utility easement for the underground service feeding the house from the ally way. Please contact Light & Power Engineering if you have any questions at 221-6700. Planning Services Contact: Clay Frickey, 970.224-6045, cfrickey(aftgov.com 1. The attached landscape plan does not clearly differentiate between the two properties. Please show property lines on the landscape plan. 2. What will the new dimensions be of each parcel? There is a minimum lot size requirement of 5,000 sq. ff. for single family homes per Land Use Code section 4.8(D)(1). It appears this proposal would push 404 Whedbee close to the minimum lot size required for the home. 3. 404 Whedbee will lose its detached garage as part of this proposal. Since 404 Whedbee has 50 feet of street frontage, you will need to provide one off-street parking spot per Land Use Code section 3.2.2(K)(1)(c). Please show where this parking spot will be located. 4. This project is located in the Eastside Neighborhood, which is part of the Old Town Neighborhoods Plan update. We encourage you to participate in this planning process as it will deal with issues like architectural compatibility and density of development amongst others. For more information about the project, please visit our website at fcgov.com/otnp or e-mail me at cfrickey@fcgov.com. 5. The proposed development project is subject to a Type 1 review and public hearing, the decision maker for Type 1 hearings is an Administrative Hearing Officer. The applicant for this development request is not required to hold a neighborhood meeting for a Type 1 hearing, but if you would like to have one to notify your neighbors of the proposal, please let me know and I can help you in setting a date, time and location for a meeting. setback appears to be ut 12' so the new rear setback can never , ess than 12' 3. If the change requires a reduction of lot frontage a minimum of 40 feet is still required for any lot frontage. Similarly the new lot at 517 E Magnolia can never be less than it's current lot size which appears to be 4500 s.f. Obviously the applicant is attempting to enlarge the lot so I'll stop belaboring the point. Department: Water -Wastewater Engineering Contact: Wes Lamarque, 970-416.2418, wlamarque(a)fcgov.com 1. Existing water and sewer mains in the vicinity include a water main on the north side of Magnolia St. and an eight inch sewer main in the alley to the east. 2. The water conservation standards for landscape and irrigation will apply. Information on these requirements can be found at: http://www.fcgov.com/standards 3. Development fees and water rights will be due at building permit. Department: Traffic Operations Contact: Martina Wilkinson, 970-221-6887, mwilkinson(cDfcgov.com 1. This proposal is not expected to generate any additional traffic and as such there is no requirement for a traffic impact study. Department: Stormwater Engineering Contact: Wes Lamarque, 970-416-2418, wlamargue(Dfcgov.com 1. If there are no site improvements that require grading or an increase in impervious area, there are no Stormwater requirements. Please contact Water Utilities Engineering if site improvements are anticipated. Department: Fire Authority Contact: Jim Lynxwiler, 970.416.2869, jlynxwiler(a)poudre-fire.org 1. Fire access and water supply requirements have been achieved through the existing street and utility infrastructure. No further fire department comment needed. Department: Environmental Planning Contact: Kelly Kimple, , kkimple(aDfcgov.com 1. With respect to landscaping and design, the City of Fort Collins Land Use Code, in Article 3.2.1 (E)(2)(3), requires that you use native plants and grasses in your landscaping or re landscaping and reduce bluegrass lawns as much as possible. 2. The applicant should make note of Article 3.2.1(C) that requires developments to submit plans that "...(4) protects significant trees, natural systems, and habitat". Note that a significant tree is defined as a tree having DBH (Diameter at Breast Height) of six inches or more. If any of the trees within this site have a DBH of greater than six inches, Fort of Community Development and Neighborhood Services 281 North College Avenue PO Box 580 Fort Collins, CO 80522 970.221.6750 970.224,6134 - fax fcgov.com August 28, 2015 Mark Mcfann 517 E Magnolia St Fort Collins, CO 80524 Re: 517 E Magnolia - Replat Description of project: This is a request to replat two properties located 517 E Magnolia and 404 Whedbee (Parcel #'s 9712334015 and 9712334017). The proposal calls for the rear half of 404 Whedbee to become part of 517 E Magnolia. The two parcels have the same owner. The parcels are located in the Neighborhood Conservation — Medium Density (NCM) zone district. This proposal will be subject to Administrative (Type 1) review. Please see the following summary of comments regarding the project request referenced above. The comments offered informally by staff during the Conceptual Review will assist you in preparing the detailed components of the project application. Modifications and additions to these comments may be made at the time of formal review of this project. If you have any questions regarding these comments or the next steps in the review process, you may contact the individual commenter or direct your questions through the Project Planner, Clay Frickey, at 970-224-6045 or cfrickey@fcgov.com. Comment Summary: Department: Zoning Contact: GaryLopez, 970-416-2338, glopez(c)fcgov.com 1. As these are lots are already platted and no additional lots are created a non -regulated property land transfer with property line adjustment might be the only requirement. A new legal description for both properties must be given to us which was recorded at the courthouse. Now there may be some other considerations I've not been made aware of in requiring a re -plat. 2. Without seeing the proposed lot line adjustment or re -plat my only comment is that any noncompliant standards such as setback, floor area ratios, etc. cannot exceed or increase the current non-compliance. In other words the lot line change cannot result in a standard being further out of compliance then it already is. An example would be the south property line at 517 E Magnolia. It can move south but not north as it is considered the rear property line which requires a 15' setback. Currently the rear