HomeMy WebLinkAbout2601 CANTON CT. - PDP/FDP - FDP160033 - CORRESPONDENCE - REVISIONSComment Number 8: Text masked on elevations where necessary.
Comment Number 9: The benchmark information is shown in the EXACT format as dictated.
Comment Number 10: The benchmark information has been modified to match in both locations.
Comment Number 11:1 did not receive redlines from Technical Services but attempted to remedy all line
over text issues where found.
Comment Number 22: 1 did not receive redlines from Technical Services but attempted to remedy all
hatch over text issues where found.
Landscape Plan.
Comment Number 5: Line over text issues addressed.
Lighting Plan
Comment Number 6: Text over text issues addressed.
Site Plan
Comment Number 1: Legal description revised.
Comment Number 2: Sheet titles revised.
Comment Number 3: Line over text issues addressed.
Comment Number 4: Text masked as necessary.
Department: Water Conservation
Comment Number 1: Irrigation plan to be submitted with building permit application.
Department: Water -Wastewater Engineering
Comment Number 1: 5'separation is maintained between the fire line and water service.
Comment Number 2: MEP is providing the justification letter.
Comment Number 3: Redline comments have been addressed.
Department: Zoning
Comment Number 1: Solid metal, 6' high fence to be installed. Color to match building. No barbed wire
is proposed.
Department: Stormwater Engineering
Comment Number 2: A letter of intent is forthcoming — this is the same owner so it will not be an issue.
Comment Number 3: The bio-swale has been regraded to have a 2' wide bottom.
Comment Number 4: Labels have been changed from Grassed Swale to Bio Swale.
Comment Number 5: An LID table and exhibit are included in the drainage report. We meet the 10:1
ratio. The rain garden was not able to work in this location due to the depth being less than 12".
Comment Number 6: The outlet structure detail has been updated to include only a water quality plate
since detention is anticipated to be provided off site in the Natural Resources ponds.
Comment Number 7: A section was added to Section 3 discussing the 4 step
Comment Number 8: References have been changed from Grassed Swale to Bio Swale.
Comment Number 9: Changes to page 4 were made as requested.
Comment Number 10: The Hydrologic Computations have been updated.
Comment Number 11: We are pursuing an easement with Natural Resources which would allow us to
detain in the existing ponds to the east of this site therefore this comment would no longer apply.
Comment Number 12: We are pursuing an easement with Natural Resources which would allow us to
detain in the existing ponds to the east of this site therefore this comment would no longer apply.
Comment Number 13: The WQCV calculation has been included in the report.
Comment Number 14: Acknowledged.
Comment Number 15: The grading has been corrected and the curb opening has been eliminated. See
revised grading plan
Comment Number 16: The grading has been corrected and no grading is occurring off site to the north.
Comment Number 17: Notes have been added to indicate curb types.
Comment Number 18: A concrete pan has been added.
Comment Number 19: Slope labels been added.
Department: Erosion Control
Comment Number 1: See revised Erosion Control Plan, Erosions Control Report and Escrow/Security
Calculation based upon the redline comments.
Department: Technical Services
Comment Number 7: Building elevation line over text issues resolved.
Department: Light and Power
Comment Number 1: Power will probably be accessed from Canton Court. Will coordinate service with
Light and Power.
Comment Number 2: Understood typical service charges will apply.
Comment Number 3: Transformer located to south of driveway from Canton Court.
Comment Number 4: C-1 form will be provided with building permit application. Electrical design not
completed but anticipate service will be 3-phase, 1200 amp. '
Department: PFA
Comment Number 1: Fire sprinkler system is being provided in this building
Comment Number 2: An emergency access easement will be dedicated in the north drive aisle by
separate document
Comment Number 3: Fire lane no parking signs are shown on the utility plan and a detail is shown on
the detail sheet.
Comment Number 4: Security gate shall be provided with means of fire department entry. Gates will
comply with IFC requirements.
Comment Number 6: Building address to be located as required by IFC.
Department: Planning Services
Comment Number 1: No off -site easements.
Comment Number 2: Shade trees added to south side and west side of property. Shade tree added to
new parking island.
Comment Number 3: 6% interior landscaping provided, landscaped island added to west end of parking,
14 parking spaces provided.
Comment Number 4: Building sidewalk 6' wide. Face of building 8' from parking.
Comment Number 5: Dimensions added to site plan. EAE added to site plan.
Comment Number 6: Bicycle parking provided on west landscape island.
Comment Number 7: Colors/finishes added to elevations.
Comment Number 8: Rear yard will be used for storing landscape materials and other construction
materials. Limited vehicle use in this area. Solid metal, 6' high fence proposed. Color to match building.
Comment Number 9: Signature block updated.
2601 Canton Court FDP 160033
Review Round 2 Comment Responses
Department: Engineering Development Review
Comment Number 1: The fire line routing has been revised so that an offsite easement will not be
required.
Comment Number 2: The water service routing has been revised to connect at the end of the existing
water service.
Comment Number 3: The plat from the original subdivision shows a 6' utility easement— I don't know
where the 15' easement originated therefore we are now showing the 6' easement.
Comment Number 4: The proposed sidewalk width is labeled as 4.5' wide.
Comment Number 5: The driveway layout is now radial to the cul de sac.
Comment Number 6: The driveway has been regraded to eliminate the need for the sidewalk chase.
Comment Number 7: This detail has been updated.
Department: Environmental Planning
Comment Number 1: Off -site detention pond included on site and landscape plans. Upland seed mix
noted on Landscape Plan.
Comment Number 2: Area to be seeded depicted on Landscape Plan.
Department: Forestry
Comment Number 1: Tree inventory and mitigation included on Landscape Plan.
Comment Number 2: Cockspur Hawthorn changed to Honey Locust.
Comment Number 3: Shrubs realigned to protect existing trees.
Comment Number 4: Tree protection specifications added to Landscape Plan.
Department: Internal Services
Comment Number 1: Permit pre -submittal meeting will be scheduled to address building department
concerns.