Loading...
HomeMy WebLinkAbout625 S. PETERSON MULTI-FAMILY - PDP - PDP160005 - REPORTS - RECOMMENDATION/REPORT W/ATTACHMENTS (9)Staff Report — 625 S Peterson St Multi -family, PDP160005 Planning & Zoning Board Hearing, 8-11-2016 Page 17 ATTACHMENTS: 1. Zoning & Site Vicinity Map 2. Applicant's Modification of Standard Requests 3. 625 S Peterson St Multi -family Planning Document Set (Site Plan, Lighting Plan, Landscape Plan, and Architectural Elevations) 4. Findings of Fact for 625 S Peterson St Multi -family from the Landmark Preservation Commission Staff Report —625 S Peterson St Multi -family, PDP160005 Planning & Zoning Board Hearing, 8-11-2016 Page 16 D. The Project Development Plan complies with relevant standards of Article 3 — General Development Standards, provided the modification to Section 3.8.11(C)(3) is approved. E. The Project Development Plan complies with relevant standards located in Division 4.8 Neighborhood Conservation, Medium Density (NCM) of Article 4 — Districts, provided the modification to Section 4.8(E)(4) is approved. RECOMMENDATION: Staff recommends that the Planning and Zoning Board approve the 625 S Peterson St Multi -family, Modification of Standards and PDP160005 based on the findings of fact and conclusions found on pages 15-16 of the Staff Report. Staff Report — 625 S Peterson St Multi -family, PDP160005 Planning & Zoning Board Hearing, 8-11-2016 Page 15 Peterson St. Neighbors will retain their access to sunlight as outlined in the applicant's modification request for wall height. 6. Recommendation from Landmark Preservation Commission Since this project is within the Laurel School Historic District, this proposal went to the Landmark Preservation Commission for a final recommendation on May 11, 2016. The members of the Landmark Preservation Commission voted 6-0 to recommend approval of the 625 Peterson St Multi -family PDP. Committee members found the proposed building does not adversely affect the historic integrity of the property and area of adjacency. Other considerations the commission noted included the project's: • Traditional proportions and building modules • Similar massing to historic context • Historically scaled materials • Historic window patterns • Architectural forms similar to adjacent historic context • Similar pedestrian scale to that of the area of adjacency 7. Findings of Fact/Conclusion: In evaluating the request for the 625 S Peterson St Multi -family Project Development Plan, Staff makes the following findings of fact: A. The Project Development Plan complies with the process located in Division 2.2 — Common Development Review Procedures for Development Applications of Article 2 — Administration. B. The Modification of Standard to Section 3.8.11(C)(3) that is proposed with this Project Development Plan meets the applicable requirements of Section 2.8.2(H), in that the granting of the Modification would not be detrimental to the public good and the proposal submitted is equal to or better than a proposal that would meet the code. C. The Modification of Standard to Section 4.8(E)(4) that is proposed with this Project Development Plan meets the applicable requirements of Section 2.8.2(H), in that the granting of the Modification would not be detrimental to the public good and the proposal submitted equal to or better than a proposal that would meet the code. Staff Report — 625 S Peterson St Multi -family, PDP160005 Planning & Zoning Board Hearing, 5-11-2016 Page 14 enclosures are allowed in the setback area per Land Use Code section 3.19(A)(2). Table 2 - Dimensional Standards Standard Provided Min. lot width 50 feet 50 feet Min. front yard setback 15 feet 19 feet Min. rear yard setback 5 feet 15 feet Min. side yard setback See modification request #2 See modification request #2 Max. building height 2 stories 2 stories F. Section 4.8(F) — Development Standards The proposed building meets all applicable development standards including exterior wall angles, primary entrance features, roof pitch, front fagade character (covered entry feature), side fagade character (wall offset), and taking access off the alley behind Peterson St. 5. Neighborhood Meetinq In accordance with Land Use Code section 2.2.2, staff held a neighborhood meeting for this project on November 9, 2015. All property owners within 800 feet received notice of the meeting two weeks in advance of the meeting per the Land Use Code. 15 people attended the meeting and offered the following feedback: • Concern over the size of the structure and its density • Ensure neighboring properties have access to sunlight given the size of the building • Context is mainly single-family homes, worried about project changing the character of the block • Retain privacy of adjacent properties • Concern about parking impacts The applicant responded to this feedback by requesting a taller fence along a portion of the southern property line to minimize privacy concerns. To minimize the impact of the mass of the building, the addition is setback 70 feet from Staff Report — 625 S Peterson St Multi -family, PDP160005 Planning & Zoning Board Hearing, 8-11-2016 Page 13 4. Compliance with Article 4 of the Land Use Code — Neighborhood Conservation, Medium Density (NM, Division 4.8: The project complies with all applicable Article 4 standards as follows: A. Section 4.8(B)(3)(a) — Permitted Uses Multi -family dwellings up to 4 units per building constructed on a lot that contained a structure on October 25, 1991 in a street -fronting principal building is an allowed use subject to review by the Planning and Zoning Board. B. Section 4.8(D)(1) — Required Lot Area The minimum lot size required for a multi -family dwelling is 6,000 square feet. The lot at 625 Peterson is 12,000 square feet. C. Section 4.8(D)(2)(a)(4) —Allowable Floor Area on Lots For uses other than single-family dwellings and buildings accessory to single-family dwellings, the allowable floor area shall not exceed 40% of the lot area. Since the lot is 12,000 square feet, the maximum floor area is 4,800 square feet (12,000 * .4 = 4,800). The proposed floor area for the building is 4,332 square feet, which is below the maximum allowed. D. Section 4.8(D)(3) — Allowable Floor Area on Rear Half of Lots The allowable floor area on the rear half of the lot shall not exceed 33% of the rear 50% of the lot. On a 12,000 foot lot, this means the maximum floor area allowed in the rear half of the lot is 1,980 square feet (6,000 * .33 = 1,980). 92 square feet of the proposed building will be in the rear half of the lot. E. Section 4.8(E) — Dimensional Standards The NCM zone district has various setback and building height standards. Barring the maximum building wall height standard, the proposed plan meets all of the dimensional requirements of the zone district. Please note the front yard setback was measured to the building as opposed to the porch since porches are allowed in the setback area per Land Use Code section 3.8.19(A)(10). Please also note the rear yard setback was measured to the nearest parking space since walls for trash and recycling Staff Report — 625 S Peterson St Multi -family, PDP160005 Planning & Zoning Board Hearing, 8-11-2016 Page 12 various sizes. Most of the houses on Peterson contain a front porch, sloping roof forms, and a combination of brick or wood siding. Some of the houses contain additions or additional houses that have been built in the rear of the lot. One multi -family apartment building, The Chateau, is located on the parcel adjacent to 625 Peterson to the north. The Chateau is a 2-story, 16-unit apartment building that was built in 1969. The Chateau has a flat roof with brick and board and batten siding. On the west side of the alley that serves Peterson Street, the development pattern is more varied and contains larger structures. Three apartment complexes occupy most of the block that fronts on Mathews Street behind 625 Peterson Street. These apartments were all built between 1965 and 1969. 634 Mathews contains 24 units with similar architectural qualities to the Chateau. 620 Mathews contains 48 units in a 2.5-story brick building with a flat roof and outdoor balconies for each unit. 625 Peterson Street fits within the context on Peterson and Mathews streets in terms of building size, height, bulk, mass, and scale. Many of the architectural features of the building addition reflect similar features in the homes surrounding including wood siding, gable roofs, scalloped siding, a front porch, and period appropriate windows. While the building will be amongst the tallest residential structures in the immediate vicinity, the design of the building will make the height less imposing. The tallest portions of the addition will be setback more than 70 feet from the property line. The second -story gables are also stepped back on the addition to prevent the building from looming over its neighbors. Outdoor Storage Areas/Mechanical Equipment The proposed plan is consistent with the requirements of the Land Use Code in regards to the location of outdoor storage, screening of storage areas, and screening of rooftop mechanical equipment from public view. Operational/Physical Compatibility The proposed plan is consistent with the requirements of the Land Use Code in regards to hours of operation, placement of trash receptacles and location and number of off-street parking spaces. O. Section 3.6.6 — Emergency Access The proposal meets the standards for providing adequate access for emergency vehicles and emergency service providers as required in Chapter 9 of the City Code, which satisfies this code section. Staff Report — 625 S Peterson St Multi -family, PDP160005 Planning & Zoning Board Hearing, 8-11-2016 Page 11 M. Section 3.2.4 - Site Lighting The proposed lighting plan is consistent with the requirements of the Land Use Code in regards to the general standard, lighting levels and design standards. N. Section 3.2.5 - Trash and Recycling Enclosures Trash and recycling enclosures must be provided in locations abutting refuse collection or storage areas, shall be designed to allow walk-in access without having to open the main service gate, shall be screened from public view and shall be constructed on a concrete pad. The proposed trash and recycling enclosure abuts the alley, allows walk-in access without having to open the main service gate, is screened from public view, and is built on a concrete pad. O. Section 3.4.7 — Historical Resources The project is located in the Laurel School Historic District. The Laurel School Historic District is listed on the National Register of Historic Places. Due to this historic designation, the property is subject to the requirements in 3.4.7 of the Land Use Code and review by the Landmark Preservation Commission (LPC). LPC reviewed this project and provided a final recommendation at their regular meeting on May 11, 2016. Historic Preservation staff and the LPC found the project to be in compliance with all elements of this section of the Land Use Code and recommended approval of the project. P. Section 3.5.1 - Building and Project Compatibility The proposed plan is consistent with the requirements of the Land Use Code in regards to building and project compatibility including building size, height, bulk, mass, scale, mechanical equipment screening and operational/physical compatibility. Size, Height, Bulk, Mass and Scale Peterson Street contains a mix of one and two-story structures. Most of the structures on Peterson Street are single-family detached houses of Staff Report — 625 S Peterson St Multi -family, PDP160005 Planning & Zoning Board Hearing, 8-11-2016 Page 10 Section 3.2.2(J) - Setbacks The proposed parking lot is setback further than the 10-foot minimum from non -arterial streets and 5-foot minimum along a lot line required per the Land Use Code. J. Section 3.2.2(K) — Off -Street Parking Requirements The site plan shows 7 parking spaces to serve the proposed development. Based on the standards for multi -family developments, the minimum amount of parking for this development is 7 spaces. Table 1 - Parking Requirements Min. Parking Parking Provided One bedroom unit 1.5 spaces 1 unit * 1.5 2 spaces Two bedroom units 3.5 spaces 2 units * 1.75 3 spaces Three bedroom unit 2 spaces 1 unit * 2 2 spaces Total 7 spaces 7 spaces K. Section 3.2.2(K)(5) - Handicap Parking Parking lots with 1-25 parking spaces are required to provide one handicap parking space with an 8-foot access aisle to make the space van accessible. The site plan shows one handicap parking space, which is in close proximity to entrances on the west side of the building. The site plan also shows the handicap space having an 8 foot access aisle to make the space van accessible. L. Section 3.2.3 - Solar access, orientation, shading All developments must be designed to accommodate active and/or passive solar installations and must not deny adjacent properties access to sunshine. The proposed building is designed and located to minimize the casting of shadows on adjacent properties and could accommodate future active and/or passive solar installations. Staff Report — 625 S Peterson St Multi -family, PDP160005 Planning & Zoning Board Hearing, 8-11-2016 Page 9 mitigation trees on -site. Each mitigation tree satisfies the caliper size requirement for a mitigation tree. E. Section 3.2.2(C)(4)(b) - Bicycle Parking Space Requirements For multi -family residential, one bike parking space is required per bedroom with at least 60% provided in an enclosed space. The proposed development will contain 8 bedrooms, which will require a total of 8 bicycle parking spaces with 5 provided in an enclosed space. On the proposed site plan 9 bicycle parking spaces are shown. All 9 spaces are provided next to the parking area with 5 covered by an overhead roof and the remaining 4 uncovered. F. Section 3.2.2(C)(5) - Walkways Walkways must be provided to link sidewalks with building entries through parking lots. These walkways must also provide direct connections to off - site pedestrian and bicycle destinations. A series of walkways are shown to provide proper pedestrian access to the each unit. Each of the rear units has a walkway that connects to the parking area in the rear of the site. This walkway then connects to a series of 24" square precast concrete pavers that acts as a connection to the sidewalk along Peterson Street. The front unit will retain the existing sidewalk connection to Peterson Street. Bicycles will have direct access to the alley and to Peterson St. G. Section 3.2.2(D) — Access and Parking Lot Requirements All vehicular use areas in any proposed development shall be designed to be safe, efficient, convenient and attractive, considering use by all modes of transportation that will use the system. The proposed parking area meets these requirements by providing unobstructed access to vehicles, separating modes, and providing parking in an appropriate location off the alley. H. Section 3.2.2(E) - Parking Lot Layout The proposed parking lot layout is consistent with requirements of the Land Use Code in regards to circulation routes, orientation, and points of conflict. Staff Report — 625 S Peterson St Multi -family, PDP160005 Planning & Zoning Board Hearing, 8-11-2016 Page 8 3. Compliance with Article 3 of the Land Use Code — General Development Standards: The project complies with all applicable General Development Standards as follows: A. Section 3.2.1(D)(2) - Tree Planting Standards - Street Trees The Land Use Code requires canopy shade trees to be planted at 30'-40' spacing in the center of parkway areas where the sidewalk is detached from the street. Peterson Street already contains two Kentucky Coffee Trees spaced 25' apart. The proposed landscape plan shows these trees to remain in place. B. Section 3.2.1(E)(3) — Water Conservation All proposed landscaping should be designed to incorporate water conservation materials and techniques. The annual water use should not exceed 15 gallons/square foot over the site. The proposed landscaping uses low water use plants and has an overall annual water budget of 12.05 gallons/square foot. C. Section 3.2.1(E)(4) - Parking Lot Perimeter Landscaping Parking lots with six or more spaces must be screened from abutting uses and the street through fences or walls in combination with plant material. The proposed landscape plan shows both a fence and a series of shrubs to screen the new parking area from adjacent properties. Six (6) proposed evergreen trees are shown on the northern property line along with nine (9) evergreen trees on the south property line adjacent to the parking area to provide further year-round screening. D. Section 3.2.1(F) — Tree Protection and Replacement To the extent feasible, existing significant trees should be preserved. Numerous trees in fair or poor health exist on the site currently but are proposed to be removed as part of this plan. The tree mitigation plan submitted shows 19 trees being removed. These 19 trees to be removed require 22.5 mitigation trees. The proposed landscape plan shows 23 Staff Report — 625 S Peterson St Multi -family, PDP160005 Planning & Zoning Board Hearing, 8-11-2016 Page 7 Staff finds that the proposed plan meets the general purpose of the standard equal to or better than a proposal that would comply with the code. The purpose of this standard is twofold: to prevent looming structures that cast shadows on adjacent properties and to minimize privacy concerns with residents in the second floor of a new building looking down into adjacent properties. 625 Peterson has a unique context in that a multi -family building called the Chateau is located immediately to the north. The Chateau is a two-story, multi -family structure and has a 25' strip of lawn that abuts 625 Peterson St. Since the proposed addition is two -stories and the abutting property is two -stories as well with a large strip of lawn acting as a buffer, the looming and privacy concerns are not as pronounced as other areas of the NCM. The privacy and looming issues are minimized on the property to the south as 625 Peterson is proposing an 8- foot high fence to minimize privacy concerns. Due to these unique circumstances, the primary concern is the architectural form of the building. The building could use a hip roof or dutch hip roof to meet this standard. However, very few buildings in the area utilize hip or dutch hip roofs in the area. The predominant roof form on Peterson St is a gable roof, which is the roof pattern proposed for 625 Peterson St. Since this property is located in the Laurel School Historic District, complementary architecture is paramount. The proposed roof forms were well received by the Landmark Preservation Commission and complement the existing architecture on Peterson St. The building wall height would also be lowered if the property was not in a floodplain, which is an existing physical hardship outside the control of the property owner. A plan that is not compliant with the City's floodplain requirements poses a far greater concern than a wall that is marginally taller than permitted in the Land Use Code. This proposed plan complies with the floodplain requirement and provides an attractive architectural treatment to allow the building to fit in to the neighborhood. So, while the proposed wall heights do not meet the requirements outlined in Land Use Code section 4.8(E)(4), the proposed plan meets the code better than would a compliant plan. The unique context, architecturally compatible roof forms, and design that meets the floodplain requirements has resulted in a design that meets the code equal to or better than a plan that would be compliant with the code. Staff Report — 625 S Peterson St Multi -family, PDP160005 Planning & Zoning Board Hearing, 8-11-2016 Page 6 Modification #2 Description: The applicant requests a Modification to Section 4.8(E)(4) — Minimum Side Yard and Maximum Wall Height to have a building wall that exceeds 18 feet in height and does not step back at a ratio of 1 foot for every 2 feet in wall height over 18 feet. Land Use Code Standard Proposed to be Modified (areas underlined and bolded for emphasis): Land Use Code 4.8(E)(4): Minimum side Vard width shall be five (5) feet for all interior side yards. Whenever any portion of a building wall alonq a side lot line exceeds eighteen (18) feet in height, as measured from the natural grade at the interior side lot line adjacent to the wall, such portion of the building wall shall be set back from the interior side lot line an additional one (1) foot, beyond the minimum required, for each two (2) feet or fraction thereof of building wall height that exceeds eighteen (18) feet in height, except as provided for in subparagraph (a) below. Summary of Applicant's Justification: The applicant requests that the Modification be approved and provides the following justification based upon Criterion 1 (proposal submitted is equal to or better than a proposal that would meet the code): Applicant's Justification for Modification #2: • The finished floor of the addition had to be positioned nearly 2 feet higher than the existing house due to floodplain issues. • The rooflines could be altered to be compliant but the roof form proposed is more appropriate with the neighborhood context. Staff Finding: Staff finds that the request for a Modification of Standard to section 4.8(E)(4) is justified by the applicable standards in 2.8.2(H)(1). A. The granting of the Modification would not be detrimental to the public good B. The project design satisfies 2.8.2(H)(1): the plan as submitted will promote the general purpose of the standard for which the modification is requested equally well or better than would a plan which complies with the standard for which a modification is requested. Staff Report — 625 S Peterson St Multi -family, PDP160005 Planning & Zoning Board Hearing, 8-11-2016 Page 5 (4) the plan as submitted will not diverge from the standards of the Land Use Code that are authorized by this Division to be modified except in a nominal, inconsequential way when considered from the perspective of the entire development plan, and will continue to advance the purposes of the Land Use Code as contained in Section 1.2.2. Any finding made under subparagraph (1), (2), (3) or (4) above shall be supported by specific findings showing how the plan, as submitted, meets the requirements and criteria of said subparagraph (1), (2), (3) or (4). Summary of Applicant's Justification: The applicant requests that the Modification be approved and provides the following justification based upon Criterion 1 (proposal submitted is equal to or better than a proposal that would meet the code): Applicant's Justification Modification #1: • The neighbor to the south requested a taller fence to provide enhanced privacy during the development review process. Staff Finding: Staff finds that the request for a Modification of Standard to Section 3.8.11(C)(3) is justified by the applicable standards in 2.8.2(H)(1). A. The granting of the Modification would not be detrimental to the public good B. The project design satisfies 2.8.2(H)(1): the plan as submitted will promote the general purpose of the standard for which the modification is requested equally well or better than would a plan which complies with the standard for which a modification is requested. Staff finds that the proposed plan equal to or better than a plan that would met the code. The adjacent property owner to the south is currently building an addition to their house that would have a bedroom near the fence to the property at 625 Peterson St. A fence with two feet of additional height will reduce the privacy concerns of this neighbor from the new two-story addition proposed as part of this project. The fence will line up with the addition that is currently under construction and will return to a height permissible in this Land Use Code section for the remainder of the fence. This context sensitive design of the fence will alleviate concerns of a two-story structure looking down upon this new addition next door. Since the fence will meet the code for majority of its length and will respond appropriately to feedback from a neighbor, staff finds the proposed plan is equal to or better than a plan that would meet the code. Staff Report —625 S Peterson St Multi -family, PDP160005 Planning & Zoning Board Hearing, 8-11-2016 Page 4 2. Compliance with Section 2.8.2(H) of the Land Use Code - Modification of Standards Modification #1 Description: The applicant requests a Modification to Section 3.8.11(C)(3) — Fences and Walls to build a fence in a side yard setback area in a rear yard that exceeds 6 feet in height. Land Use Code Standard Proposed to be Modified (areas underlined and bolded for emphasis): Land Use Code 3.8.11(C)(3): Fences shall be ... (3) no more than six (6) feet high if located within any required rear yard setback area or within any side yard setback area in a rear yard; Land Use Code Modification Criteria: "The decision maker may grant a modification of standards only if it finds that the granting of the modification would not be detrimental to the public good, and that: (1) the plan as submitted will promote the general purpose of the standard for which the modification is requested equally well or better than would a plan which complies with the standard for which a modification is requested, or (2) the granting of a modification from the strict application of any standard would, without impairing the intent and purpose of this Land Use Code, substantially alleviate an existing, defined and described problem of city-wide concern or would result in a substantial benefit to the city by reason of the fact that the proposed project would substantially address an important community need specifically and expressly defined and described in the city's Comprehensive Plan or in an adopted policy, ordinance or resolution of the City Council, and the strict application of such a standard would render the project practically infeasible; or (3) by reason of exceptional physical conditions or other extraordinary and exceptional situations, unique to such property, including, but not limited to, physical conditions such as exceptional narrowness, shallowness or topography, or physical conditions which hinder the owner's ability to install a solar energy system, the strict application of the standard sought to be modified would result in unusual and exceptional practical difficulties, or exceptional or undue hardship upon the owner of such property, provided that such difficulties or hardship are not caused by the act or omission of the applicant; or Staff Report — 625 S Peterson St Multi -family, PDP160005 Planning & Zoning Board Hearing, 8-11-2016 Page 3 1 : 625 5 Peterson St Multi-tanlily Lonlnq & tiae Vic E Mayuolia St VI ![�:]FE:1 E Myrtle SI rSite tanlannid Sr 4 gt cc E Laurel SI NCB EMulberry St N E m LId NCIW E Plum St f Leammp r 9nW AT-= =9 HE NC 1 inch = 333 feet 625 Peterson - Multi -family Vicinity Map 4��` Staff Report — 625 S Peterson St Multi -family, PDP160005 Planning & Zoning Board Hearing, 8-11-2016 Page 2 • The Modification of Standard to Section 3.8.11(C)(3) that is proposed with this Project Development Plan meets the applicable requirements of Section 2.8.2(H), in that the granting of the Modification would not be detrimental to the public good and the proposal submitted is equal to or better than a proposal that would meet the code. • The Modification of Standard to Section 4.8(E)(4) that is proposed with this Project Development Plan meets the applicable requirements of Section 2.8.2(H), in that the granting of the Modification would not be detrimental to the public good and the proposal submitted is equal to or better than a proposal that would meet the code. • The Project Development Plan complies with relevant standards of Article 3 — General Development Standards, provided the modification to Section 3.8.11(C)(3) is approved. • The Project Development Plan complies with relevant standards located in Division 4.8 Neighborhood Conservation, Medium Density (NCM) of Article 4 — Districts, provided the modification to Section 4.8(E)(4) is approved. COMMENTS: 1. Background The property was part of the Original Town Site Annex on January 16, 1873. The property was platted as the north half of Lot 3, Block 146 as indicated on the Fort Collins 1873 Map. Initially, the site contained a single-family home built in 1898. The property owners renovated the property in the 1930's and 1970's. At some point in the 1980's or 1990's the house was converted into a duplex. The surrounding zoning and land uses are as follows: Direction Zone District Existing Land Uses North Neighborhood Conservation — Medium Residential Density NCM South Neighborhood Conservation — Medium Residential, school Density NCM East Neighborhood Conservation — Medium Residential Density NCM Neighborhood Conservation — Medium West Residential Density (NCM) Below is a zoning and site vicinity map. City of fit Collins ITEM NO _ MEETING DATE STAFF August 11`", 2016 Clay Frickey PLANNING & ZONING BOARD PROJECT: 625 S Peterson St Multi -family, PDP160005 APPLICANT: Brad Massey alm2s 712 Whalers Way Building B, Suite 100 Fort Collins, CO 80525 OWNERS: Heitmann Properties LLC 1421 Rollinwood Ln Fort Collins, CO 80525 PROJECT DESCRIPTION: This is a request for a Project Development Plan to redevelop an existing two -unit house at 625 South Peterson St into a 4-unit building by constructing an addition in the rear. According to Larimer County property records, the original house was built in 1898 with additions and/or renovations in the 1930's and 1970's. The current main floor is a 2-bedroom/ 1 bathroom unit while the upper level is also a 2-bedroom/ 1 bath unit. When exactly it was converted into a duplex is unknown, but is generally believed to be in the late 80's or early 90's. The site is located in the Neighborhood Conservation - Medium Density District (NCM) zone district. RECOMMENDATION: Staff recommends approval of 625 S Peterson St Multi -family, P D P 160005. EXECUTIVE SUMMARY: Staff finds the proposed 625 S Peterson St Multi -family Project Development Plan complies with the applicable requirements of the City of Fort Collins Land Use Code (LUC), more specifically: • The Project Development Plan complies with the process located in Division 2.2 — Common Development Review Procedures for Development Applications of Article 2 — Administration. Planning Services 281 N College Ave — PO Box 580 — Fort Collins, CO 80522-0580 fcgov.com/developmentreview/ 970.221.6750