Loading...
HomeMy WebLinkAboutHOME2 SUITES AT HARMONY VILLAGE - FDP - FDP160016 - CORRESPONDENCE - (3)Comment Number: 7 Uomment Originated: 04/26/2016 04/26/2016: Please change the sheet numbers to match the index on sheet 1. See redlines. Topic: Site Plan Comment Number: 1 Comment Originated: 04/26/2016 04/26/2016: Some of the sheet titles in the sheet index do not match the sheet titles on the noted sheets. See redlines. Department: Water Conservation Contact: Eric Olson, 970-221-6704, eolson@fcgov.com Topic: General Comment Number: 1 Comment Originated: 04/25/2016 04/25/2016: Irrigation plans are required no later than at the time of building permit. The irrigation plans must comply with the provisions outlined in Section 3.2.1(J) of the Land Use Code. Direct questions concerning irrigation requirements to Eric Olson, at 221-6704 or eolson@fcgov.com Department: Water -Wastewater Engineering Contact: Shane Boyle, 970-221-6339, sboyle@fcgov.com Topic: General Comment Number: 1 Comment Originated: 04/18/2016 04/18/2016: Please label Utility Easements on the Utility Plan. If the proposed fire hydrant is not within an existing Utility Easement, one will need to be dedicated. Comment Number: 2 Comment Originated: 04/18/2016 04/18/2016: Please see redlines for additional comments. Department: Zoning Contact: Noah Beals, 970-416-2313, nbeals@fcqov.com Topic: General Comment Number: 1 Comment Originated: 04/26/2016 04/26/2016: Where are the elevations of the accessory structures? 4 Department: Stormwater Engineering Contact: Jesse Schlam, 970-218-2932, ischiam@fcgov.com Topic: Erosion Control Comment Number: 4 Comment Originated: 04/19/2016 04/19/2016: Erosion Control Report was acceptable. Erosion Control Plan needs to address some redlines and based off those changes the erosion control escrow will need to be recalculated. Contact: Shane Boyle, 970-221-6339, sbovle@fcgov.com Topic: General Comment Number: 1 Comment Originated: 04/18/2016 04/18/2016: Please label existing easements on the Grading Plan. If the proposed bioretention facilities are not located within an existing Drainage Easement, one will need to be dedicated with this project. Comment Number: 2 Comment Originated: 04/18/2016 04/18/2016: Some of the calculations provided in the Drainage Report do not follow Fort Collins approved methodology. Please see redlines and revise accordingly. Comment Number: 3 Comment Originated: 04/18/2016 04/18/2016: Please see Utility Plan and Drainage Report redlines for additional comments. Department: Technical Services Contact: Jeff County, 970-221-6588, jcounty@fcgov.com Topic: Building Elevations Comment Number: 3 Comment Originated: 04/26/2016 04/26/2016: Please clean up the fuzziness around the text and/or line work. See redlines. Comment Number: 4 Comment Originated: 04/26/2016 04/26/2016: Please change the titles to match other plans. See redlines. Comment Number: 5 Comment Originated: 04/26/2016 04/26/2016: Please add sheet numbers. See redlines. Topic: Construction Drawings Comment Number: 8 04/26/2016: No comments. Comment Originated: 04/26/2016 Topic: Landscape Plans Comment Number: 2 Comment Originated: 04/26/2016 04/26/2016: There are line over text issues. See redlines. Topic: Lighting Plan Comment Number: 6 Comment Originated: 04/26/2016 04/26/2016: Please change the titles to match other plans. See redlines. c order to confirm and to pass along clear direction to the contractor, please add a note on the architectural sheets that the "Beacon" will not be internally or externally illuminated. Comment Number: 4 Comment Originated: 04/27/2016 04/27/2016: Please add the cornice detail back on to the architectural elevation sheets. Comment Number: 5 Comment Originated: 04/27/2016 04/27/2016: On the Site Plan Cover Sheet, under Note Number 6, please add: "Under canopy lighting must be fully recessed and installed with a flush mount, flat lens." This installation is the only way to shield the light source. Department: Engineering Development Review Contact: Katie Sexton, 970-221-6501, ksexton@fcqov.com Topic: General Comment Number: 1 Comment Originated: 04/26/2016 04/26/2016: Water/stormwater comments indicate you may need to dedicate additional easements. More information regarding the easement dedication process can be found here: http://www.fcgov.com/engineering/pdf/Easrowdedications20l O.pdf Comment Number: 2 Comment Originated: 04/26/2016 04/26/2016: Larimer County doesn't need to approve plans, please remove the signature block. Department: Environmental Planning Contact: Kelly Kimple, 970-416-2401, kkimple@fcgov.com Topic: General Comment Number: 1 Comment Originated: 04/26/2016 04/26/2016: Please add the following note to the landscape plans: "All tree removal shown shall be completed outside of the songbird nesting season (Feb 1 - July 31) or a survey will be conducted of the trees to be removed to ensure that no active nests are present." Comment Number: 2 Comment Originated: 04/26/2016 04/26/2016: In regard to LED light fixtures, cooler color temperatures are harsher at night and cause more disruption to circadian rhythms for both humans and wildlife. Please consider choosing the warmer color temperature (warm white, 3000K or less) for your LED light fixtures, when available. Please also consider fixtures with dimming capabilities so that light levels can be adjusted as needed. Department: Internal Services Contact: Russell Hovland, 970-416-2341, rhovland@fcqov.com Topic: General Comment Number: 1 Comment Originated: 04/15/2016 04/15/2016: This applicant needs to schedule a pre -submittal building code review meeting as soon as possible. Russ Hovland 416-2341. 2 Fort Collins Community Development and Neighborhood Services 281 North College Avenue PO Box 580 Fort Collins. CO 80522 970.221.6750 970.224.6134 - fax fcgov. com/developmentreview April 29, 2016 Ken Merritt JR ENGINEERING ON BEHALF OF EAST AVENUE DEVELOPMENT LLC 2900 SOUTH COLLEGE AVENUE Fort Collins, CO 80525 RE: Home2 Suites at Harmony Village, FDP160016, Round Number 1 Please see the following summary of comments from City staff and outside reviewing agencies for your submittal of the above referenced project. If you have questions about any comments, you may contact the individual commenter or direct your questions through the Project Planner, Ted Shepard, at 970-221-6343 or tshepard@fcgov.com. Comment Summary: Department: Planning Services Contact: Ted Shepard, 970-221-6343, tshepard@fcqov.com Topic: General Comment Number: 1 Comment Originated: 04/27/2016 04/27/2016: It appears that architectural elevations are not the latest set of revised plans. Please note that the amount of Loveland Buff (not "Bluff") Sandstone has been reduced along east (front) and south (side) elevations. Please restore the amount of stone per the approved P.D.P. In addition, the five columns along the north elevation that were previously called out to be stone have been replaced by what appears to be steel (TS-1.) All of these columns must be restored to stone. Also, the window treatments (stone sills in lintels) that we agreed to at P.D.P. is not shown. Please restore all architectural details per the P.D.P. Comment Number: 2 Comment Originated: 04/27/2016 04/27/2016: 1 will need a sample of the "Laminated White Frosted Glazing "Beacon" in order to evaluate its opacity. Also, please describe in a detail what exactly is the "White SS Frame." Comment Number: 3 Comment Originated: 04/27/2016 04/27/2016: Neither the Lighting Plan or the cut sheets indicate any fixture for the purpose of internally illuminating the aforementioned beacon. Thank you for responding to our earlier comments and concerns in a positive manner. In