HomeMy WebLinkAboutHARMONY TECHNOLOGY PARK, 1ST, CELESTICA - FDP - 12-97B - CORRESPONDENCE - REVISIONSJAN-26-99 12.09 FROM.YOUNC•NRICHT 969-3522 ID. PACE 2/25 Young+Wright Memorandum Archhocu Inc. ,f To City of Fort Collins Community Planning and Environmental Services From Robert 0. Macpherson, Associate Re Celestica Colorado Date January 26, 1998 172 SL George Sweet lob No. 9704fi Toronto, Ontario M5R 2M7 TEL: 41 &%8-3522 FAX: 416r96o.o172 We have prepared a point by point response to the City of Fort Collins Community Planning and Environmental Services Staff memo, dated January 13, 1998. Each number below corresponds to the Staff memo comment numbers; items not responded to below will be addressed by BHA Design under separate cover. 1. At present, Celestica is studying options for nitrogen supply, with the preferred solution being a nitrogen production plant and an adjacent storage tank. We are advised that installation specifications will be submitted to the City of Fort Collins with the building permit application. 2. High Pile storage is anticipated. The building design for the area containing high pile storage will conform with Article 81 of the Uniform Fire Code. 3. Celestica Colorado has prepared a list of hazardous materials expected to be used and stored at the site, identified in a memo dated November 11, 1997, with an addendum memo "Chemical Usage for New Building", dated January 21 1998; both documents are attached. 8. All garbage and recycling processes will be located in the building interior. There will be sufficient space allocated to recycling requirements in the final design. 10. The building will be designed in accordance with the City of Fort Collins Non-residential Energy Code (ASHRAE 90.1 with locally adopted amendments). Please advise if we can provide any further information or clarification of the above. copy Vidya Welling, Celestica Inc. 1448 5663 Angie Milewski, BHA Design Inc. / 970 223 1827 design height. The maximum building height has been defined as 39'-6" to allow for parapet walls as necessary to screen any rooftop mechanical equipment. 12. Done. 13. Done. 14. A note has been added to both the Site and Landscape Plans. 15. The transit stops have been indicated on the Site Plan. 16. Done. 17. Done. 18. Done. 19. Done. Please feel free to call if you have any questions or need additional information. Sincerely, bh ign inc. by Bruce A. January 26, 1998 Mr. Ted Shepard City of Fort Collins Planning 281 N. College Avenue Fort Collins, CO 80521 RE: Celestica Colorado Drawing Revisions Dear Ted, Thank you for your comments of January 12, 1998, and your additional comments over the phone. We have addressed many of the comments through our revisions to the Final Compliance Plans. Outlined below is a response to specific items mentioned in your letter relating to planning comments. Attached is a separate letter from the architects relating to your comments on the architecture. Our response numbers correspond with your letter number. 1-3 These comments are addressed in a separate letter from Young+Wright Architects. 4. All specified uses have been contained within dedicated easements shown on the plat. 5. We have added a note to the landscape plan (Sheet 3 of 6) specifying the required separations from streetlights as they are located. 6. All grading in this area is contained within the right-of-way or easements illustrated on the plat. 7. Done. 8. This comment has been addressed in a separate letter from Young+Wright Architects. 9. Accessible routes of travel have been illustrated on the site plans (Sheets 1 and 2). Slopes in these areas meet the specified requirements and crosswalks are designated where necessary. 10. This comment has been addressed in a separate letter from Young+Wright Architects. 11. We have adjusted the building height to specifically indicate the proposed design LANDSCAPE ARCHITECTURE URBAN DESIGN PLANNING BHA DESIGN, INC. 4903 INNOVATION DRIVE FT. COLLINS, CO 80323 TEL 970 223-7577 FAX 900 223-/027