HomeMy WebLinkAboutHARMONY TECH. PARK 2ND AMENDED ODP - 12-97E - CORRESPONDENCE -21. An amendment to the Harmony Road A -line may be needed. This process is
governed by CDOT with City assistance.
22. Utility Plans will be needed at the time of submittal. A Development Agreement
will be required prior to recording final documents. A Development Construction
Permit will be required prior to beginning site work. For further information,
please contact Marc Virata, 221-6605.
23. The construction phase will require a Fugitive Dust Permit from the Larimer
County Health Department if the property is under construction for over a certain
time period . Also, trash enclosures should be sized to accommodate various
containers for recycling. A single trash hauler should be used. An Ecological
Characterization Study will not be needed. For further information on natural
resource issues, please contact Doug Moore, at 221-6750.
24. For an estimate of the Capital Improvement Expansion Fee, payable at the time of
building permit issuance, please contact the Building Inspection Division, 221-
6760. This fee is adjusted annually.
25. The architectural character of the buildings must conform to the standards in
Section 3.5.1 and 3.5.3 of the Land Use Code. Please note that the building must
include a recognizable base, middle and top. Please be aware that if the buildings
feature flat roofs, a parapet. or cornice will be required to comply with this
standard.
26. Existing trees should be preserved. Signage should be strategically placed to
avoid conflicts with the foliage of the trees.
v
and drainage patterns. The report and grading plan must be prepared by a
professional engineer registered in Colorado. For water quality, extended
detention is the recommended method to treat the runoff and is required for
redevelopment of a site. This is a 40-hour sedimentation pond. Other acceptable
methods may be found in Volume Three of the materials published by the Urban
Drainage and Flood Control District.
13. One-half of the site drains north and one-half drains south. For the northern one-
half, stormwater flows into the barrow ditch along Harmony Road. This water
ultimately flows into the Fossil Creek Inlet Ditch. Erosion control structures, and
possibly ditch improvements, will be needed for draining into this outfall. For the
southern one-half, there are storm sewer outlets in Rock Creek Drive which is an
approved public outfall for this site. Detention pond volume must be designed for
the 100-year storm. According to the master drainage plan, the maximum
allowable release rate from the detention ponds is .5 cubic feet per second. For
further information, please contact Basil Harridan, 221-6700.
14. Please contact Matt Baker, 221-6605, to determine the Street Oversizing Fee and
the Larimer County Road Fee. " These fees are based on square footage, land use
and trip generation. Fees are adjusted annually and due at the time of building
permit issuance.
15. There will need to be a nine -foot utility easement dedicated behind the right of
way along Cambridge and any other local public street.
16. Upon completion of the enclave annexation, Staff will initiate a street name
change for Cambridge Avenue as this is a duplicate name. Since it is a collector,
the name can only be selected from the official list that has been adopted by City
Council.
17. The east -west street through the center may need to be public as it serves multiple
parcels and buildings.
18. Harmony/Cambridge intersection is eligible for a traffic signal in accordance with
the Access Control Plan.
19. The project will be responsible for constructing street improvements along all
abutting public streets, including Cinquefoil. In addition, the
Harmony/Cinquefoil intersection will need to be improved.
20. An eastbound deceleration lane will be needed along Harmony Road for the
Cinquefoil intersection. Cinquefoil cannot be blocked during construction as it
serves as the second point of emergency access for the Brookfield/Morningside
residential development.
W
5. If any Modifications of Standards are needed, then the request must be forwarded
to the Planning and Zoning Board either as a stand-alone Modification or in
conjunction with the Project Development Plan (P.D.P).
6. Bike racks must be provided near the entrance. Handicap parking spaces would
be required, one of which must be van -accessible. Foundation shrubs around the
buildings are required. Signs are reviewed separately by the Sign Code which is
not part of the P.D.P. process. For further information regarding the Sign Code,
please contact Gary Lopez, 221-6760.
7. There is existing electrical system along the south side of Harmony Road and an
underground vault at Cambridge. This system has adequate power to serve the
proposed land uses. Any new system extended to serve the site must be placed
within an easement. , I -
8. Transformers must be placed within ten feet of hard surface for emergency
change out. Normal site and development charges will apply. A Commercial
One ("C-1 ") Form must be completed by a licensed electrical contractor to
determine entrance capacity for each building. Please contact Light and Power
for the hand-out describing the development fees and charges. For further
information, please contact Bruce Vogel, 221-6700.
9. There is a 16-inch diameter water main in Cambridge. There is a 12-inch water
main stubbed to the southwest portion of site. Water mains should be looped .
through the site by extending the 12-inch main over to Cinquefoil. A repay is due
on the 16-inch line in Cambridge.
10. The water conservation standards for landscape and irrigation will apply to the
project. Development fees and water rights will be due at time of building permit.
For further information, please contact Jeff Hill, 221-6700.
11. The site will be served by the Poudre Fire Authority. All addresses must be
clearly visible from the public street on which the buildings front. A fire
protection system is required for hood and duct systems in the restaurants and
convenience store. All portions of the exterior of the building must be within 150
_feet of the private access drives. (Poudre Fire does not consider Harmony Road
an appropriate roadway for fire -fighting.) Any internal fire access roadway must
be dedicated as a public emergency access easement, with pavement markings
and curbs painted red. If this cannot be accomplished, then an automatic fire
extinguishing system must be installed. There are no tap fees for automatic fire
sprinkler lines. For further information, please contact Ron Gonzales, 221-6570.
12. This site is in the McClelland -Mail Creek drainage basin where the new
development fee is $3,717/acre which is subject to runoff coefficient reduction.
The drainage and erosion control report will need to address the imperviousness
ITEM: Harmony Technology Park Amended Overall Development
Plan, Parcels G, H and I.
MEETING DATE: January 26, 2004
APPLICANT: Mr. Les Kaplan c/o Mr. Bruce Hendee, B.H.A. Design,
4803 Innovation Drive, Fort Collins, CO 80525
LAND USE DATA: Request to amend Parcels G, H, and I in order to accommodate a
mix of primary and secondary uses for a proposed commercial development within
Harmony Technology Park. The site is located at the southeast corner of Harmony Road
and Cambridge Avenue. Combined, the parcels comprise approximately, 12.61 acres.
COMMENTS:
The site is zoned H-C, Harmony Corridor which permits the bank as a primary
use. The hotel is considered a secondary use, as are the uses associated with the
Convenience Shopping Center. The proposed amendment must not result in more
than 25% of the entire O.D.P. being devoted to secondary uses.
2. The Convenience Shopping Center must comply with the parameters as defined in
Article Five of the Land Use Code. It cannot exceed seven acres in size and must
include four or more business establishments with separate exterior entrances,
located in a complex which is planned, developed and managed as a single unit,
and located within and intended to primarily serve the consumer demands of the
adjacent employment areas.
An 80-foot landscape buffer is required along Harmony Road. This setback area
must feature an eight -foot wide meandering sidewalk, undulating berms, and
predominance of oak trees. Buildings along Harmony will be required to connect
to the public walk with private walkways on a per building basis. Such walks
should not cross a parking lot drive aisle or driveway. Parking lots are prohibited
in the setback zone.
4. The placement of commercial buildings and the relationship with public
sidewalks is governed by the build -to line standards. These standards are in
Section 3.5.3 and require that the buildings along a collector street (Cambridge
Avenue) be located no further than 15 from the right-of-way.
COMMUNITY PLANNING AND ENVIRONMENTAL SERVICES 281 N. College Ave. P.O. Box 580 Fort Collins, CO 80522-0580 (970) 221-6750
CURRENT PLANNING DEPARTMENT
Comm Ay Planning and Environmenta. ervices
Current Planning
City of Fort Collins
February 6, 2004
Mr. Bruce Hendee
BHA Design, Inc.
4803 Innovation Drive
Fort Collins, CO 80525
Dear Bruce:
For your information, attached is a copy of the Staff s comments for Harmony
Technology Park Amended Overall Development Plan which was presented before
the Conceptual Review Team on January 26, 2004.
The comments are offered by staff to assist you in preparing the detailed components of
the project application. Modifications and additions to these comments may be made at
the time of formal review of this project.
If you should have any questions regarding these comments or the next steps in the
review process, please feel free to call me at 970-221-6750.