Loading...
HomeMy WebLinkAboutHARMONY TECH. PARK AMENDED ODP - 12-97C - CORRESPONDENCE - ALTERNATIVE COMPLIANCE REQUEST (3)r, Cambridge Avenue locations fall along property boundaries of the landowners involved in the proposed ODP. While the street spacing exceeds 660', the level of connectivity provided between the ODP parcel and the adjacent development parcel is equal to that which would be provided by streets at 660' spacing. The proposed street layout meets the purpose of Section 3.6.3(F) equally as well as the spacing required by this section. Area 3 — Harmony Road Access Points. As a Major Arterial and State Highway, Harmony Road is unique in that the allowed access points have been predetermined. The ODP shows street connections at the access points set forth by the Harmony Corridor Access Control Ylan and the City of Fort Collins Master Street Plan: Area 4 — E/W Street Connection along Cambridge Avenue south of County Properties In this area, we have modified the street spacing from the 660' minimum to accommodate existing residential properties along Cambridge Avenue. An `outparcel' of County properties exists along Cambridge Avenue south of Harmony Road. At the south end of these properties, the 660' minimum spacing would require a street connection to travel through the middle of one of these existing properties. While the same number of street connections has been shown, the connection has been moved slightly south to accommodate these existing properties. The level of connectivity provided between the ODP parcel and the adjacent development parcel is equal to that which would be provided by streets at 660' spacing. The proposed street layout meets the purpose of Section 3.6.3(F) equally as well as the spacing required by this section. We are not requesting alternative compliance at the north end of these county properties. Alternative compliance cannot be requested in this location due to the adjacency of the county properties to Harmony Road. In discussions with City staff (Traffic Operations), the location of the proposed future street must be shown crossing the county properties in this area to accommodate the needs of the intersection at Harmony Road and Cambridge Avenue. We have instead shown a temporary transportation connection north of the county properties, with a future connection further south to be implemented when the County properties redevelop as required by Traffic Operations. Conclusion We believe that in each of these areas, the proposed street layout responds to the unique existing conditions and topographic features of the parcel and the specific land uses allowed within the Harmony Corridor zone district, but still accomplishes the purposes of Section 3.6.3(F) equally well or better than would a plan and design which complies with the standard. :-r Alternative Compliance Request Harmony Technology Park Amended ODP The Harmony Technology Park Amended ODP is the result of a collaborative effort between several landowners in the area south of Harmony Road and east of County Road 9. These landowners have joined to develop an overall development plan for several development projects within this area in order to help ensure a cohesive plan that responds to a wider range of patterns for transportation and land use. The Amended ODP illustrates proposed traffic circulation systems including all Collector streets or larger as required by the Land Use Code. These streets have been designed to respond to: 1. Existing road locations 2. Natural areas and unusual topographic features adjacent to the site 3. Pre -determined access points along Harmony Road (S.H. 68) as regulated by CDOT 4. Existing properties that are not a part of the overall development plan 5. Development plans for adjacent undeveloped properties 6. Development plans and land uses for the proposed ODP area. Alternative Compliance Request Land Use Code Section 3.6.3 Street Pattern and Connectivity Standards Purpose. This section is intended to ensure that the local street system is well designed with regard to safety, efficiency and convenience for automobile, bicycle, pedestrian and transit modes of travel. Alternative design must minimize the impacts on natural areas and features, fosters non - vehicular access, provide for distribution of the development's traffic without exceeding the level of service standards, enhance neighborhood connectivity and provide direct sub -arterial street access to neighborhood features within or adjacent to the development. There are four locations of the Harmony Technology Park CDP planned area which require that we request alternative compliance for spacing of sub -arterial street connections as defined in section 3.6.3(F) of the Fort Collins Land Use Code which states ... 'All development plans shall provide for future public street connections to adjacent developable parcels by providing'a local street connection spaced at intervals not to exceed six hundred sixty (660) feet along each development plan boundary that abuts potentially developable or redevelopable land.' Area 1 - East boundary of ODP area. We request alternative compliance for the provision of future street connections along the east boundary of the. ODP area in order to minimize impacts on natural areas and topographic features adjacent to the Fossil Creek Inlet Ditch. At the edge of the property, the slope drops off steeply to the Fossil Creek Inlet Ditch, and then falls further toward County Road 7. The slopes in this area are up to 50% in steepness, and providing public road access to the east perpendicular across these slopes would require substantial earthwork that would have severe impacts on the landform, the irrigation ditch and the natural features in this area. The ODP plan provides connection to County Road 7 to the south with a road alignment that responds to the topographic features and to the alignment of the ditch. We have also designated a natural areas buffer zone as requested by the Natural Resources Department to further protect this area. Area 2 — Rock Creek Drive east of Cambridge Avenue. In this area, we have modified the street spacing from the 660' minimum to respond to existing road locations and to accommodate the street patterns of the proposed neighborhoods to the south. The existing Cinquefoil Lane and a� E Ron Fuchs - harmony tech park odp µ Page 1 From: "Angela Milewski" <amilewski@bhadesign.com> To: "Ron Fuchs" <rfuchs@ci.fort-collins.co.us> Date: Wed, Sep 6, 2000 11:05 PM Subject: harmony tech park odp Ron, I reviewed the digital base file for the street connections along Ziegler Road today after our phone conversation. As you indicated, our road alignments do exceed the 660' minimum spacing along Ziegler Road. The distance from centerline to centerline between Rock Creek Drive and the proposed east/west road adjacent to the Celestica property line is approximately 1380'. By aligning the third access point midway between the roads, we would have a separation of 690', exceeding the required distance by 30'. We would like to request alternative compliance as allowed by this section of the code for the street spacing due to existing approved development in this area. 1. The approved centerline alignment of Rock Creek Drive west of Ziegler (Harvest Park) does not fall on the property boundary as would be expected. We are aligning with the approved centerline which moves this portion of the road 25' south of our south property boundary. 2. We would like to align the proposed east/west road south of the Celestica property immediately adjacent to the Celestica property boundary in order to allow direct access by Celestica and to avoid an unused land sliver that could be a potential maintenance issue. Since the existing property boundary is set, this places the road approximately 1380' north of Rock Creek Drive (centerline to centerline). 3. We would like to add only one road between these two roads for the following reasons: a)Hewlett-Packard has been working with the City through the Pilot Process program for the development of this portion of the ODP. The proposed access point facilitates the master plan for this area which will allow large employment facilities in a campus setting. The central access point provides identity to each of the buildings and provides visibility and pedestrian access directly to the central 'campus' area. I have sent a reduced copy of this master plan by fax to illustrate the campus areas. Other parking access points along Ziegler Road may be requested at the time of PDP when more detail is known about the potential users in this area, but we would like to ensure the location of the main access point at this location at the ODP stage. b)The distance only slightly exceeds the maximum allowed (30' each direction) and alternative compliance is a viable option for this layout. Please let me know if you need additional information on this matter. thanks, Angie ni .v.'�.'.:s^.'.:C�k��n:+lliv�i'E]..$F�,-%J"rN, E�d3ca.&v �,'#`uL*:'?wi4.r,.miJ,1�a.�t{+u.^'GA.c�Kr�i13ti2,A%�?ekelifv3%2'i4:R.;h'Sa<1.La:'s"i....t.,ur_v�i3tiY-.'iU�.kr�ii�ex za'�..F784:4�Sv�"iAc'�a ���:2`k�+aka^�eF�ifAtn�9�ix�.�_�Yw�'ni�.� hr%�✓o-._