HomeMy WebLinkAboutYORKTOWN CORNER - GROUP HOME REVIEW - 10-97 - CORRESPONDENCE - (3)s a) Please submit a letter of intent on offstreet parking for employees and the number of average daily trips (the driveway allows for off-street parking). b) There should be access to Care -A -Van (must be to ADA standards). Please contact Fred Jones at 221-6820 if you have questions about these comments. 8. The Current Planning Department offered the following comments: a) You will need to submit an A.P.O. (a list of affected property owners). b) A neighborhood meeting will be required and this should be held at the Unitarian Church. Please contact Leanne Lawrie at 221-6750 if you have questions about these comments. Y Please contact Glen Schlueter at 221-6589 if you have questions about these comments. 3. The Light and Power offered the following comments: a) Please call utility billing to change from residential rate to commercial rate. 4. The Water and Wastewater Departments offered the following comments: a) You will need to install a water meter. b) Please note that you will be charged at commercial rate. Please contact Jeff Hill at 221-6674 if you have questions about these comments. 5. The Building Inspections Department offered the following comments: a) After Planning and Zoning approval, you will then' need to go to the building inspections department for a change of occupancy on the building permit. (Building permit review requires a floor plan (what was submitted for conceptual review is fine). This establishes the change of C.O., and the cost is $15.00. b) With more than five (5) clients, you must have an automatic fire extinguishing system. Please contact Sharon Getz at 221-6760 if you have questions about these comments. 6. The Poudre Fire Authority offered the following comments: a) A fire sprinkler system requires a separate permit from the Poudre Fire Authority. b) Each room needs to have a smoke detector as well as the hallway. It should be set up so that when one goes off, they all go off. c) Please install fire extinguishers. d) The Poudre Fire Authority signs off on the State License. e) The fire alarm system should be wired to a monitoring company. Please contact Roger Fresco at 221-6570 if you have any questions about these comments. 7. The Traffic Operations offered the following comments: t 1: imCONCEPTUAL REVIEW STAFF COMMENTS City of Fort Collins MEETING DATE: ITEM: APPLICANT: LAND USE DATA: February 24, 1997 1933 Yorktown —Group Home Marie Mohn 2119 Ayrshire Drive Fort Collins, Colorado 80526 Request for personal board and care home consisting of four (4) bedrooms for up to eight (8) individuals on a 12, 480 square foot lot. Proposed 24-hour care supported by staff assistance with no more than two employees at a time, serving 30% Medicaid patients. COMMENTS: 1. The Zoning Department offered the following comments: a) The property is in the RL-Residential Low Density Zoning District. b) The lot size allows up to seven (7), not eight (8), based upon the lot size. c) Under the new Land Use Code, it will be a Type II, Planning and Zoning Board review. Please contact Gary Lopez at 221-6760 if you have questions about these comments. 2. The Stormwater Utility offered the following comments: a) This site is located within the Spring Creek basin where fees are $2,175/acre and it is subject to the runoof coefficient reduction. This applies only if an addition or parking lot were proposed. b) If a parking lot is proposed, a drainage study would be required. Also, an erosion control plan could be required. COMMUNITY PLANNING AND ENVIRONMENTAL SERVICES 281 N. College Ave. P.O. Box 580 Port Collins, CO80522-0580 (970) 221-6750 PLANNING DEPARTMENT w Community Planning and Environmental Services Current Planning City of Fort Collins February 27, 1997 Marie Mohn 2119 Ayrshire Drive Fort Collins, Colorado 80526 RE: Conceptual Review for 1933 Yorktown —Group Home Dear Ms. Mohn: For your information, attached is a copy of the Staffs comments concerning the request for the proposed Group Home at 1933 Yorktown which was presented before the Conceptual Review Team on February 24, 1997. The comments are offered informally by Staff to assist you in preparing the. detailed components of the project application. Modifications and additions to these comments may be made at the time of formal review of this project. If you should have any questions regarding these comments or the next steps in the review process, please feel free to call me at 221-6750. Sincerely, ov� Leanne Lawrie Project Planner xc: Eric Bracke Stormwater Utility/Glen Schlueter Project Planner / 281 North College Avenue • PO. Box 580 • Fort Collins, CO 80522-0580 • (970) 221-6750 FAX (970) 221-6378 • TDD (970) 224-6002