Loading...
HomeMy WebLinkAboutHABITAT SKYLINE SUBDIVISION - BASIC DEVELOPMENT REVIEW - BDR160015 - SUBMITTAL DOCUMENTS - ROUND 1 - DRAINAGE RELATED DOCUMENTk Cross Section for Overflow Swale Project Description Flow Element: Irregular Section Friction Method: Manning Formula Solve For: Normal Depth Section Data Roughness Coefficient: 0.030 Channel Slope: 0.80000 ft/ft Normal Depth: 0.52 ft Elevation Range: 0.00 to 1.24 ft Discharge: 31.00 ft%s TOP OF FOUNDATION N Ch 0.52 rt Workshop! for Overflow Swale 0+07 012 Worksheet for Overflow Swale Project Description Flow Element: Irregular Section Friction Method: Manning Formula Solve For: Normal Depth Channel Slope: 0.80000 ft/ft Discharge: 31.00 ft3/s Current Roughness Weighted Methc ImprovedLotters Open Channel Weighted Roughness ImprovedLotters Closed Channel Weighted Roughne Hortons Roughness Coefficient: 0.030 Water Surface Elevation: 0.52 It Elevation Range: 0.00 to 1.24 ft Flow Area: 1.73 ft' Wetted Perimeter: 6.71 ft Top Width: 6.62 ft Normal Depth: 0.52 ft Critical Depth: 1.07 ft Critical Slope: 0.01623 ft/ft Velocity: 17.95 Ws Velocity Head: 5.01 ft Specific Energy: 5.53 ft Froude Number: 6.19 Flow Type: Supercritical Segment Roughness Start Station End Station Roughness Coefficient (-0+06. 1 24) (0+07, 0.82) 1.030 Section Geometry Station Elevation -0+00 124 0+00 0.00 SUMMARY DRAINAGE SUMMARY TABLE Design Point Tributary Sub -basin Area (ac) c (10) c (100) tc (10) (min) tc (100) (min) 0(2)tot (cfs) O(10not (cfs) 0(100)tOt (cfs) REMARKS a A 0.14 0.40 0.50 7.1 6.3 0.1 0.2 0.6 0 Page 11 Interwest Consulting Group RATIONAL METHOD PEAK RUNOFF (City of Fort Collins, 100-Yr Storm) LOCATION: Habitat for Humanity - Skyline House PROJECC NO: 1291-02540 COMPUTATIONS BY: sb DATE: 8/15/2016 100 yr storm. C1= 1.25 DIRECT RUNOFF CARRY OVER AL REMARKS Des. Poini Area Design. A (ac) C Cf IC (min) i (inthr) O (100) (CIS) from Design Point O (100) (Cts) O(1 D0)tot (cfs) a A 0.14 0.50 62 9.15 0.6 0.6 0 O=CiA FLOW(08-15-16).xin O = peak discharge (cfs) C = runoff coefficient i = rainfall intensity (in/hr) from City of Fort Collins IDF curve (4/16/99) A = drainage area (acres) i = 84.682 / (10. tcf°1 RATIONAL METHOD PEAK RUNOFF (City of Fort Collins. 10-Yr Storm) LOCATION: Habitat for Humanity - Skyline House PROJECT NO: 1291-025-00 COMPUTATIONS BY: sb DATE: 8/152016 10 yr storm. Cf = 1.00 DIRECT RUNOFF ICARRY OVER[TOTAL IREIIIIAMS Design Point Trbulary A SUDnasin (ac) C CI Ic (min) I (inRa1 O (10) (d6) tram Design Paint O (10) (CIS) 0(10)tot (CIS) a A 0.14 0.40 7.1 4.30 02 0.2 0 Q=CICiA FLOW(Oa-15-16).xis Q = peak discharge (cis) C = runoff coefficient Cr = frequency adjustment factor i - rainfall intensity (in/hr) from City of Fort Collins IDF curve (4/16/99) A = drainage area (acres) i = An." 1(10, 1cff' Inter est Consulting Group RATIONAL METHOD PEAK RUNOFF (City of Fort Collins. 2-Yr Storm) LOCATION: Habitat for Humanity - Skyline House PROJECT NO: 1291-025-(1l1 COMPUTATIONS BY: sb DATE: 8115/1016 2 yr storm. Cf = 1.00 DIRECT RUNOFF CARRY OVER ITOTAL IREMARKS Design Point Tributary Su"asin A (ant C Cf tc (min) i (inihn O (2) (cts) from Design Point O (2) (cis) 0(2)101 (CIS) a A L 4 0.40 7.1 2S2 0.1 0.1 O=CICiA FLOW(09-15-16)..xls O = peak discharge (cfs) C = runoff coefficient C, = frequency adjustment factor i - rainfall intensity (inthr) from City of Fort Collins IDF curve (4/16/99) A = drainage area (acres) 1- 24.221 t n 0. lc)'' Interwest Consulting Group Interwest Consulting Group STANDARD FORM SF-2 TIME OF CONCENTRATION -100 YR LOCATION: Habitat for Humanity - Skyline House PROJECT NO: 1291-025-(K) COMPUTATIONS BY: sb DATE: 8/15/2016 100-yr storm Cf = 1.25 from Table RO-12 of City of Fort Collins Stormwater Code, Volume I SUB -BASIN DATA INITIAL /OVERLAND TIME (1t) TRAVEL TIME / GUTTER OR CHANNEL FLOW (n) tc CHECK (URBANIZED BASIN) FINAL tc REMARKS DESIGN PONIT SUBBASIN(s) (1) Area (ac) (2) C (3) C'Cf Length (ft) (4) Slope M) (5) ti (min) (6) Length (ft) (7) Slope (%) (8) n Manning rough. Vel. (f/s) (9) R (min) (10) tc = ti+n (11) Total L M (12) tc=(V180)+10 (min) (13) (min) (14) a A 0.14 0.40 0.50 32 2.0 5.0 86 0.6 0.022 1.1 1.3 6.3 118 10.7 6.3 EQUATIONS: tc=ti+It ti=(1.87(1.1-CC,)0.1]/S113 tt = L/Vel. Velocity from Manning's Equation with R=0.1 (corresponds to Figure 3-3 of City of Fort Collins Design Manual) final tc = minimum of ti + it and urbanized basin check min. tc = 5 min. due to limits of IDF curves FLOW (08-15-16).xls Interwest Consulting Group STANDARD FORM SF-2 TIME OF CONCENTRATION - 2 and 10 YR LOCATION: Habitat for Humanity - Skyline House PROJECT NO: 1291-0251K) COMPUTATIONS BY: sb DATE: 8/15/2016 2 and 10-yr Storm Cf = 1.00 Irom Table RO-12 of City of Fort Collins Stormwater Code. Volume I SUB -BASIN DATA INITIAL/OVERLAND TIME (ti) TRAVEL TIME / GUTTER OR CHANNEL FLOW (tt) to CHECK (URBANIZED BASIN) FINAL to REMARKS DESIGN PONIT SUBBASIN(s) (1) Area (ac) (2) C (3) Length (ft) (4) Slope N) (5) li (min) (6) Length (ft) (7) Slope (%) M n Manning rough. Vol. (ft/s) (9) tt (min) (10) is = ti. ft (11) Total L (ft) (12) Ic=(U78o)+10 (min) (13) (min) (14) a A 0.14 0.40 32 2.0 5.9 86 0.6 0.022 1.1 1.3 7.1 118 10.7 7.1 EQUATIONS: tc=ti+tt ti = [1.87 (1.1 - CC, ) Lo.s ] / S. 1/3 If = L/VeL Velocity from Manning's Equation With R=0.1 (corresponds to Figure 3-3 of City of Fort Collins Design Manual) final tc = minimum of ti + tt and urbanized basin check min. tc = 5 min. due to limits of IDF curves FLOW(08-15-16).zis Interwest Consulting Group RUNOFF COEFFICIENTS & %IMPERVIOUS LOCATION: Hublrat fir Humanin, - S'kplinc House PROJECT NO: 1291-025-00 COMPUTATIONS BY: sb DATE: 811"n16 Recommended Runoff Coefficients from Table RO.11 of City of Fort Collins Stormwater Code, Volume I Recommended % Impervious from Table RO-3 Urban Storm Drainage Criteria Manual, Volume I Type B Soils Streets, parking lots (asphalt) Sidewalks (concrete) Roofs Gravel or Pavers Lawns, sandy soil (Flat <2%) Runoff % coefficient Impervious C 0.95 100 0.95 96 0.95 90 0.50 40 0.10 0 SUBBASIN DESIGNATION TOTAL AREA (W.) TOTAL AREA (50) ROOF AREA (e0.11) PAVED AREA (30) SIDEWALK AREA (s0.fl) LANDSCAPE AREA (sO.B) RUNOFF COEFF, (C) % Impsrvlous REMARKS A 0.14 61003 1,540 600 0 3.863 0.00 33 Calculated C coefficients & % Impervious are area weighted C=£(CiAi) /At Cl . runoff coefficient for specific area, Ai Ai . areas of surface with runoff coefficient of Ci n . number of different surfaces to consider At . total area over which C is applicable; the sum of all Ai's FLOW(OB-16-16).sls Interest Consulting Group RUNOFF COEFFICIENTS & % IMPERVIOUS LOCATION: Habitat far Hronanhy - Sk-Wine House PROJECT NO: 1291-025-M COMPUTATIONS BY: ab DATE: 8/15/1016 Recommended Runoff Coefficients from Table RO-11 of City or Fort Collins Slormwater Code, Volume I Recommended % Impervious from Table R0-3 Urban Storm Drainage Criteria Manual, Volume I Type B Soils Streets, parking lots (asphalt) Sidewalks (concrete) Roofs Pavers Lawns, sandy loll (Flat <2%) Runoff coefficient Impervious C 0.95 100 0.95 96 0.95 90 0.50 40 0.10 0 SUBBASIN DESIGNATION TOTAL AREA (ae.) TOTAL AREA ( .11) ROOF AREA I .II PAVED AREA niqlff PAVERS AREA • .Ip SIDEWALK AREA fa .ill LANDSCAPE AREA la .II RUNOFF COEFF. IC) % IMPBNIOue REMARKS Exlalln Lot 0.14 61003 0 0 0 0 6,003 0,10 0 Pro bed Lot 0,14 6.003 1.540 600 0 0 3.663 0.40 33 Eouations - Calculated C coefficients & % Impervious are area weighted C = E (CI Ai)I At Ci = runoff coefficient for specific area, Al Al - areas of surface with runoff coefficient of Cl n - number of different surfaces to consider At = total area over which C is applicable; the sum of all At's FLOW(06-15-16).aIS No Text Ms. Heather McDowell August 15, 2016 Page 2 of 2 SWMM Master Plan that City Stormwater is modeling and it was confirmed that the output change was minimal and within the margin of error. As shown on the attached SWMM printout from the Master Plan there is 31 cfs of off -site runoff coming through the lot during the 100-year event. This flow will be routed on the south side of the property through a swale that will drain any overtopping stormwater from the street curb and gutter east through the church property to the ultimate outfall which is the canal that runs along the east side of the church property. During the 100-year event there is approximately 15" of free board from the top of foundation to the water surface of the Swale. Please see the attached channel calculation that shows the proposed grading can accommodate this overflow without impacting the house. Thank you for reviewing the proposed stormwater improvements for the proposed single family home. If you have any questions or comments please contact meat (970) 460-1091. Sincerely, Skylar Brower, P.E. Colorado Professional Engineer No. 44248 Reviewed By: Robert Almirall, P.E. Colorado Professional Engineer No. 33441 l INTl RRIetT CONSULTING GROUP August 15, 2016 Ms. Heather McDowell City of Fort Collins Storm Water Utility 700 Wood Street Fort Collins, CO 80522 Re: Drainage Memorandum — Habitat for Humanity Skyline House Dear Heather, Please accept the following letter on behalf of Habitat for Humanity to demonstrate that the proposed single family home on Skyline Drive is in compliance with current City Code. Please note that a separate erosion control / stormwater management report has been prepared for this project and erosion control is not addressed in this letter. INTRODUCTION The proposed project includes the subdivision of the existing Westminster Presbyterian Church property located in the southeast comer of W Elizabeth Street and Skyline Drive. The subdivision will consist of 0.14 acres. Habitat for Humanity will be placing one single family home on this new lot which will front Skyline Drive and is adjacent to existing single family homes in the area. EXISTING CONDITIONS The 0.14 acres of land that will be subdivided from the church is located in the southwest corner of the church property. This space is currently open space covered with natural grasses and is 100% pervious. This property is in the Canal Importation Basin Master Plan. PROPOSED DEVELOPMENT As previously mentioned, the proposed project will consist of constructing one single family home on the subdivided property. The proposed impervious area associated with the improvements is 2,140 square feet. The proposed property is located in Basin 549 of the Canal Importation Basin Master Plan which is assumed to be 45% imperviousness. The additional 2,140 sf of impervious area that will be added to this basin and the additional 0.6 cfs of runoff that it will produce will have a negligible impact to the overall drainage of the area. The additional impervious area was input into the