HomeMy WebLinkAboutHARMONY TECHNOLOGY PARK-CELESTICA - ODP - 12-97 - CORRESPONDENCE - REVISIONSdesign Ted Shepard Harmony Technology Park ODP Page 4 Road sites will be reserved for high profile businesses. 23. Done 24. Done 25. Harmony Technology Park will consist primarily of large footprint users. For example, the first phase of Celestica, which is the first development within the park will be a 200,000SF building with the potential for expansion to 600,000SF. Also, each of the large users will be engaged in acitivities that require a secure campus. The site requirements to accommodate these large users combined with the need for secured entrances makes if difficult or impossible to provide the 660' intersection spacing intervals. 26. Our understanding of the specific future use of the adjacent areas, especially to the south and east is as yet undetermined. Additionally, in a phone conversation with the transportation department,and with our traffic consultant, it is unclear whether Cambridge will be extended farther to the south. Because of these uncertainties, it is difficult to commit to a specific treatment of these edges. I would like to point out, however, that we have established specific setbacks, screening and buffering requirements for landscaping within the design guidelines that are currently being formulated by Hewlett Packard. This concludes our responses. We have attached 10 copies of the revised ODP plan for your use. Please call if we need to meet to discuss or if you need more prints. Sincerely, bha sign inc. b Bruce A. ndee, ASLA Principal design Ted Shepard Harmony Technology Park ODP Page 3 15. A 12" water line is now shown down the central spine road ( Technology Parkway) at this time. It is possible to revise the ODP at a later date if it is decided that the east side of the site is a better location. 16. We have located the future lift station at the southeast corner to facilitate this 17. We have located the future lift station at the southeast corner to facilitate this 18. The preliminary estimate of 3600 gallons per day per acre was used for water and wastewater. This is equivalent to water usage of 6 units per acre which is consistent with the City of Fort Collins Water and Wastewater Utility. More detailed flows will become available with each new user. 19. Caution is noted. 20. Noted. 21. Thank you for pointing out the stormwater issues associated with quantity, quality, and character of off site drainage release. The intent is to obtain the required off site easement across the adjacent property. This may not occur in time for the first development on the property. If it is not obtained, a retention volume will be provided within the park that meets the requirements for retention based on the developed area. The detailed aspects of this issue will be addressed at the time of the first PDP. 22. We have divided the ODP into the bubbles requested with the exception of the convenience retail. This activity may or may not occur depending on future businesses at the business park. The location will be determined as the future of the business park tenants becomes more clear. It is anticipated that the user will occupy an interior site of approximately 3 acres. More prominent Harmony design Ted Shepard Harmony Technology Park ODP Page 2 like to have the flexibility to work with their site plan needs. We are aware of the City standards and requirements and will coordinate closely with the City during plan development. 4. Addressed by Matt Delich. 5. Addressed by Matt Delich. 6. Addressed by Matt Delich. Plan has been labeled. 7. A buffer zone has been indicated. 8. No response. 9. Addressed by Matt Delich. 10. Addressed by Matt Delich. 11. Addressed by Matt Delich. 12. Addressed by Matt Delich.. Each major street within the HTP will be dedicated and will meet city standards for bike lanes and pedestrian walks. 13. A Tranfort bus shelter will be located along CR9 ( Fossil Creek Road) if appropriate however, Technology Parkway is anticipated to be the major circulation roadway for this park. Technology Parkway will be a major circulation roadway for employers with significant employment on both sides of the roadway. For that reason we would like to have the City consider the potential for a future Transfort stop (or 2) along this roadway. 14. It is understood that this is the case and future developments in design will follow the above advise. design June 27, 1997 LANDSCAPE ARCHITECTURE URBAN DESIGN Mr. Ted Shepard PLANNING Senior Planner City of Fort Collins Planning 281 N. College Fort Collins, CO. 80522-0580 RE: Harmony Technology Park ODP BHA DESIGN, INC. 2000 VERMONT Dear Ted, FT. COLLINS, CO 80325 TEL 303 213-75]] Thanks you for your letter of June 6, 1997 regarding planning and other staff 1^1 113 11'-3855 comments to the proposed ODP plan for the Harmony Technology Park (HTP). Matt Delich has responded to the comments from transportation regarding the TIS. I have added my two cents where it seemed appropriate to elaborate. I have attached a copy of his response for your records. Outlined below are responses to other comments. The comments are numbered according to their number on your original letter. Also, for the purposes of initiating discussion on a street name, CR9 has been named Fossil Creek Road. Of course we understand there needs to be dialogue, or this is the City's decision but, we would like to get a permanent name for the road so that we can accurately indicate it in our covenants, design standards, and master plan drawings. Addressed by Matt Delich. The first phase of development (Celestica will takes its phase one access off of CR 9. The access control plan modification is beginning currently. It is anticipated that by the time the second phase is ready to commence ( 1 '/s years +-), the permit will have been addressed completely through CDOT. The north/south street through the site is to be called Technology Parkway. The ODP has been modified to reflect this change. 2. Addressed by Matt Delich. 3. Addressed by Matt Delich. The layout has been modified to indicate a preliminary internal street system. Please keep in mind that each user will have separate requirements and that most users are likely to be large footprint users. To accommodate these large users we would