HomeMy WebLinkAboutKING SOOPERS, MILLER BROS. FOOTHILLS SUB. - NON-CONFORMING USE REVIEW - 14-97 - CORRESPONDENCE - (5)d. The storm sewer may not be adequate for the 100 year runoff. Therefore,
parking lot detention may be required to meet present Stormwater Utility
criteria.
Please contact Glen Schlueter at 221-6589 with any questions regarding these
comments.
8. The Poudre Fire Authority offers the following comments:
a. The expansion of the fire suppression system may trigger the need for a
second riser for water supply. The fire suppression system contractor should
be aware of this.
b. A 20 feet wide fire lane must be maintained at all times on the west side of
the building as this fire lane is the Poudre Fire Authority's only access to the
rear of the shopping center. Construction of the proposed expansion may
need to be staged to accommodate this fire access requirement.
9. The Current Planning Department offered the following comments:
a. As stated by the Zoning Department, the existing shopping center remains
classified as a Nonconforming Use. Please refer to Section 1.5.5(A) (Article
1, pages 18 -20) of the Land Use Code for information pertaining to the
Planning and Zoning Board's review of the proposed expansion.
b. As stated in Section 1.5.5(B) of the Land Use Code "the parcel of ground
upon which the building facility, equipment or structure is located shall be
brought into compliance with the applicable general development standards
contained in Article 3 and the applicable district standards contained in
Article 4 (N-C District is Article 4, pages 110-116) of this Land Use Code'.
C. A copy of the submittal requirements checklist was provided to the applicant.
d. As per the Director of Planning, Section 2.2.2 (Step 2: Neighborhood
Meeting) of the Land Use Code has been waived.
e. A geographical notification map is attached. The applicant is responsible for
obtaining the names and addresses of all property owners within this
boundary. Please submit one set of these names and addresses on mailing
labels (33 labels per 8.5 x11 sheet), one reproducible copy of the list on 8.5
x 11 sheet(s), and a $0.50 per name notification mailing fee with the
development application.
f. The Nonconforming Use Review fee is currently $1,216.
Please contact Mike Ludwig at 221-6206 with any questions regarding these
comments.
f. Existing and proposed parking needs must be addressed in the submittal
information.
Please contact Sheri Wamhoff at 221-6750 with any questions regarding these
comments.
6. The Building Inspections Department offers the following comments:
a. The applicant will need to obtain a separate permit to alter the existing .
sprinkler system for the store. The fire suppression system must be
continued into the proposed areas of expansion.
b. Please contact the Building Inspections Department as soon as possible to
discuss the fire wall rating for the south wall of the existing Buckaroos store.
The same fire wall rating that exists between the existing King Soopers and
Buckaroos will need to be constructed between the south wall of the
expanded King Soopers and the remainder of the existing shopping center
building.
Please contact Sharon Getz at 221-6760 with any questions regarding these
comments.
7. The Stormwater Utility offers the following -comments:
a. The site is platted as the "Replat of Miller Brothers Foothills Subdivision,
Filing 6." It is located in the Canal Importation Drainage Basin. The
Stormwater Development Fees for this basin are $6,181 per acre, subject to
a runoff coefficient reduction. However, it appears that the proposed
expansion is planned for an area that is already paved and therefore will not
be creating any additional impervious surface area. Stormwater
Development Fees will only apply to any newly created impervious surface
area.
b. The 1986 drainage report will need to be updated (verify existing
grading/drainage patterns and the effects of the expansion on the same) and
a standard drainage and erosion control report and plan will need to be
prepared by a registered engineer in the State of Colorado.
C. The existing storm sewer that runs beneath the existing shopping center
would not be allowed if it were proposed today. However, since it is existing,
it is "Grand fathered" in. The Stormwater Utility recommends consideration
of a safety outlet that would prevent a back up of the storm sewer from
entering the building. The applicant may.want to consider adding manholes
for this storm sewer.
t
appears that the Buckaroos portion of the shopping center building may be served
by a separate service than the existing King Soopers. The existing Buckaroos
service will need to be abandoned if the applicant intends to extend the King
Soopers service to the proposed areas of expansion. Please contact Roger
Buffington at 221-6681 with any questions regarding these comments.
4. The Engineering Department offers the following comments:
a. West Elizabeth Street west of Taft Hill Road has been reclassified as a minor
arterial street. The 'h R.O.W. width for a minor arterial is 42 feet from the
centerline. Please verify the existing R.O.W. width along West Elizabeth
adjacent to this site. Improvements along Elizabeth Street must be in
accordance with the minor arterial street standard.
b. The Street Oversizing Fee is currently $19,443 per acre for the new portions
of the expansion.
C. A Transportation Impact Study which addresses vehicle, bicycle and
pedestrian levels of service is due at the submittal of the development
application. Please contact Eric Bracke of the Transportation Department
at 221-6615 with any questions regarding the content or information required
in the TIS.
d. Standard utility plans must be submitted and a development agreement will
be required for all public improvements.
5. The Transportation Planning Department offers the following comments:
a. Bicycle, pedestrian and transit accessibility must be addressed in the
Transportation Impact Study.
b. It appears that two ramps are missing along the pedestrian route to the
shopping center from the transit stop on W. Elizabeth (northwest of the King
Soopers).
C. Bike racks are needed in front of the grocery store for customer use. The
applicant should provide bike lockers for employee use.
d. There is an existing 10 foot wide walkway from the adjacent residential
neighborhood on the west side of the building. Options for a more direct
access to the center from this walkway must be addressed in the
Transportation Impact Analysis.
e. Pedestrian circulation through the parking lot to the store must be clearly
designated. Painted, patterned, and/or raised delineations must be provided
at the crossings of vehicular drives.
�1
CONCEPTUAL REVIEW STAFF COMMENTS
City of Fort Collins
MEETING DATE: April 14, 1997
ITEM: King Soopers Store #9 Expansion.
APPLICANT: Michael Bray, AIA
Michael Bray Architects
P.O. Box 733
Parker, CO 80134
LAND USE DATA: Request for a 5,165 square feet expansion to the south side of
the existing store. In addition the applicant will be renovating
5,625 square feet of existing building directly adjacent (south)
of the existing King Soopers. The property is located at the
southwest corner of Taft Hill Road and West Elizabeth Street
in the Cedarwood Plaza.
COMMENTS:
1. The Zoning Department stated that the property is zoned N-C, Neighborhood
Commercial and that the Cedarwood Plaza Shopping Center remains classified as
a Nonconforming Use. The proposed expansion is subject to a non -conforming use
review by the Planning and Zoning Board. Please contact Gary Lopez at 221-6760
with any questions regarding these comments.
2. The Light and Power Utility stated that there is an existing transformer on the
north side of the building which should not be affected by the proposed expansion.
If the proposed expansion causes a change in the size of the service required, a "C-
1" electrical use form must be submitted and the transformer may need to be
changed at the developers expense. If there is a conflict between the proposed
expansion and the existing transformer on the south side of the building which
serves the remainder of the center, it must be relocated at the developer's expense.
This will also result in system modification and out -time charges. Please contact
Alan Rutz at 221-6700 with any questions regarding these comments.
3. The Water and Wastewater Utility stated that Water Conservation Standards for
Landscaping and Irrigation will be applicable. The applicant indicated that no
changes to the existing service or additional services will be needed. However, it
COMMUNITY PLANNING AND ENVIRONMENTAL SERVICES 281 N. College Ave. P.O. Box 580 Fort Collins, CO 80522.-0580 (970) 221-6750
PLANNING DEPARTMENT
8
Community Planning and Environmental Services
Current Planning
City of Fort Collins
April 22, 1997
Michael Bray, AIA
Michael Bray Architects
P.O. Box 733
Parker, CO 80134
Dear Michael,
For your information, attached is a copy of the Staff's comments concerning a request for
the King Soopers Store #9 Expansion, which was presented before the Conceptual
Review Team on April 14, 1997.
This is a request for a 5,165 square feet expansion to the south side of the existing store.
In addition the applicant will be renovating 5,625 square feet of existing building directly
adjacent (south) of the existing King Soopers. The property is located at the southwest
comer of Taft Hill Road and West Elizabeth Street in the Cedarwood Plaza.
The comments are offered informally by Staff to assist you in preparing the detailed
components of the project application. Modifications and additions to these comments
may be made at the time of formal review of this project.
If you should have any questions regarding these comments or the next steps in the review
process, please feel free to call me at 221-6206.
Sincerely,
fiw4l i
Michael Ludwig
Project Planner
xc: Stormwater Utility
Project Planner