HomeMy WebLinkAboutELEVATIONS CREDIT UNION - PDP - PDP160021 - REPORTS - RECOMMENDATION/REPORT W/ATTACHMENTS (13)Elevations Credit Union PDP #160021
Type 1 Hearing, September 28, 2016
Page 6
3. Landscape Plans
4. Building Elevations and Perspective Renderings
5. Utility Plans
6. Photometric Plan
7. Ecological Characterization Study (ECS) Memo
Elevations Credit Union PDP #160021
Type 1 Hearing, September 28, 2016
Page 5
D. Division 3.10 — Transit -Oriented Development (TOD) Overlay Zone
• The site planning in the TOD Overlay requires street -fronted primary
buildings, gathering spaces, and outdoor spaces. The proposed
building is fronted on the corner of Arthur Drive and College Avenue
and provides an outdoor gathering space along the College Avenue
side.
• The character and image in the TOD Overlay requires similar
articulation as noted above (Sec. 3.2.3) but also requires specific
roofline treatment and high quality materials that add to pedestrian
interest. The proposed building has a three-dimensional cornice
treatment and the predominant material is a 5/8 inch fiber cement
product (see material sample.) The base will be constructed with sand
blasted concrete.
5. Findings of Fact/Conclusion
In evaluating the request for the Elevations Credit Union Project Development Plan,
PDP #160021, Staff makes the following findings of fact:
A. The P.D.P. complies with process located in Division 2.2 — Common
Development Review Procedures for Development Applications of Article
2 — Administration.
B. The P.D.P. complies with relevant standards located in Article 3 — General
Development Standards.
C. The P.D.P. complies with relevant standards located in Division 4.21,
General Commercial (C-G) of Article 4 — Districts.
RECOMMENDATION:
Staff recommends approval of the Elevations Credit Union Project Development Plan,
PDP #160021
ATTACHMENTS:
1. Statement of Planning Objectives
2. Site Plan
Elevations Credit Union PDP #160021
Type 1 Hearing, September 28, 2016
Page 4
3) 3.2.4 Site Lighting:
• A photometric plan was submitted for the project. As proposed, the
project complies with the standards for light levels and directional
down -lit fixtures.
B. Division 3.4 — Environmental, Natural Area, Recreational and Cultural
Resource Protection Standards
1) 3.4.1 Natural Habitats and Features:
• The project provided an Ecological Characterization Study (ECS)
memo which reveals that the Sherwood lateral (irrigation ditch across
Arthur Drive) is of low ecological value thus a buffer will not be applied.
The project proposes to use native plants as recommended in the ECS
memo.
C. Division 3.5 — Building Standards
• Per section 3.5.3(C) Relationship of Buildings to Streets, Walkways
and Parking, the building is oriented toward the southeast corner
(College Avenue and Arthur Drive) of the lot. The plan provides
pedestrian access from the street sidewalks and parking spaces to
primary and secondary entrances. The building is setback 23 feet 5
inches from the property line on College Avenue to comply with the
build -to line of 10 — 25 feet. It is setback 10 feet from the Arthur Drive
property line to comply with the build -to line of 0 — 15 feet.
• The proposed building provides a custom site -specific design. There is
a great deal of variation in massing with strongly modulated masses
varying in height and wall length.
• Section 3.2.3(D)(1) requires horizontal masses not to exceed a
height:width ratio of 1:3 without "substantial variation". Each mass
provides material changes, windows, plane changes, and projections
within the noted span of height:width ratio.
• Section 3.2.3(E)(2) requires that no wall facing a street or connecting
walkway have a blank or uninterrupted length exceeding 30 feet. Each
wall of each side is highly articulated and provides architectural
features such as eaves, windows, plane changes, material changes,
and doors in a far less distance than every 30 feet. See attached
building elevations.
Elevations Credit Union PDP #160021
Type 1 Hearing, September 28, 2016
Page 3
B. Section 4.21(D) — Land Use Standards
1) Section 4.21(D) The maximum building height shall be four stories.
• The proposed building is one story in height (20 feet maximum).
C. Section 4.21(E) — Development Standards
1) Section 4.21(E)(2) Pedestrian -oriented outdoor spaces shall be
placed next to activity areas that generate the users (such as street
corners, shops, stores, offices, day care and dwellings).
• The proposed site plan includes a plaza/courtyard along the
College Avenue frontage. It includes planters, benches and seat
walls.
3. Compliance with Article 3 of the Land Use Code — General
Development Standards
The project complies with all applicable General Development Standards; with the
following relevant comments provided:
A. Division 3.2 — Site Planning and Design Standards
1) 3.2.1 Landscaping and Tree Protection:
• A detailed tree mitigation plan is provided with this P.D.P. in
coordination and with the approval of the City Forester.
2) 3.2.2 Access, Circulation and Parking:
• The project is providing a 10 foot -wide detached sidewalk along
College Avenue, consistent with the Midtown in Motion Plan, and
maintaining the existing four foot -wide attached sidewalk along Arthur
Drive and Spring Court.
• Access is taken off of College Avenue via a right -in -only drive, and a
full -movement access onto Arthur Drive.
• Required minimum parking for financial services is 2 spaces per 1,000
square feet for a total minimum requirement of 10 parking spaces. The
proposal is providing 25 parking spaces.
Elevations Credit Union PDP #160021
Type 1 Hearing, September 28, 2016
Page 2
• The P.D.P. complies with process located in Division 2.2 — Common
Development Review Procedures for Development Applications of Article 2 —
Administration.
• The P.D.P. complies with relevant standards located in Article 3 — General
Development Standards, with conditions.
• The P.D.P. complies with relevant standards located in Division 4.21, General
Commercial District (C-G) of Article 4 — Districts.
COMMENTS:
1. Background:
The subject property was annexed into the City of Fort Collins in 1957 with the South
College Avenue Consolidated Annexation. The existing development has been a gas
station and convenience store for many years. The proposed project will demolish the
gas station and convenience store.
The surrounding zoning and land uses are as follows:
Direction
Zone District
Existing Land Uses
North
General Commercial (GC)
Commercial: pet service and auto service
South
General Commercial (GC)
Commercial: bike shop and mattress store
East
General Commercial (GC)
Commercial strip mall
West
General Commercial (GC)
Residential duplexes
2. Compliance with Article 4 of the Land Use Code — General Commercial
(C_G):
The project complies with all applicable Article 4 standards as follows:
A. Section 4.21(B) — Permitted Uses
The proposed land use, Offices and Financial Services, are permitted
subject to Administrative Review (Type 1).
City of
Fit Collins
ITEM NO 1
MEETING DATE 9-28-16
STAFF Lorson
ADMINISTRATIVE PUBLIC HEARING
PROJECT: Elevations Credit Union Project Development Plan, PDP #160021
APPLICANT: Cara Scohy, CS Design, Inc.
2519 S. Shields St. #129
Fort Collins, CO 80526
OWNER: Elevations Credit Union
C/O Mike Tressler
2300 55th Street
Boulder, CO 80301
PROJECT DESCRIPTION:
This is a request for consideration of a Project Development Plan (P.D.P.) for Elevations
Credit Union. The project is located on a 0.72 acre lot at the northwest corner of south
College Avenue and Arthur Drive.
The project proposes a one-story, 5,000 square foot financial services building with two
drive -through teller lanes and 25 parking spaces. The project includes a plaza with rain
gardens, planters and benches along the College Avenue frontage. The construction
will include the demolition of an existing retaining wall that travels along the north
property line diagonally to the west side of the lot. A new retaining wall, with an
approximate height of between 9 feet and 0.5 feet, is proposed along 97 feet of the
north property line and along 117 feet of the west property line. See attached Utility
Plans for more details. The proposed financial services use is permitted in the General
Commercial (CG) zone district by review and approval from a hearing officer at a Type 1
public hearing.
RECOMMENDATION: Approval of Elevations Credit Union Project Development Plan,
PDP #160021
EXECUTIVE SUMMARY:
The approval of Elevations Credit Union Project Development Plan complies with the
applicable requirements of the City of Fort Collins Land Use Code (LUC), more
specifically:
Planning Services 281 N College Ave — PO Box 580 — Fort Collins, CO 80522-0580
fcgov.com/developmentreview/ 970.221.6750