HomeMy WebLinkAboutWORTHINGTON AVENUE RESIDENCES - PDP - PDP160023 - REPORTS - RECOMMENDATION/REPORT W/ATTACHMENTS (11)Staff Report —Worthington me Residences, PDP160023
Planning & Zoning Board 10-13-2016
Page 18
4. Centre for Advanced Technology 241h Filing Plat
5. Worthington Avenue Residences Planning Document Set (includes site plan,
landscape plan, elevations, and photometric plan)
6. Walking Distance to New Mercer Commons Open Space
7. Worthington Avenue Residences Ecological Characterization Study
8. Worthington Avenue Residences Traffic Impact Study
9. Neighborhood meeting summary — July 14, 2016
Staff Report —Worthington }. ,iue Residences, PDP160023
Planning & Zoning Board 10-13-2016
Page 17
a mailing two weeks in advance. Seven community members participated in the
neighborhood meeting. Most of the community members' questions dealt with
unit construction, unit layout, leasing, the development timeline, amongst other
general questions. No community member raised a concern about the proposed
development.
6. Findings of Fact/Conclusion:
In evaluating the request for the Worthington Avenue Residences Project
Development Plan, Staff makes the following findings of fact:
A. The Project Development Plan complies with the process located in Division
2.2 — Common Development Review Procedures for Development
Applications of Article 2 — Administration.
B. The Project Development Plan complies with relevant standards of Article 3 —
General Development Standards.
C. The Modification of Standard to Section 4.27(D)(2) that is proposed with this
Project Development Plan meets the applicable requirements of Section
2.8.2(H), in that the granting of the Modification would not be detrimental to
the public good and the proposal submitted promotes the general purpose of
the code standard equal to or better than would a compliant plan.
D. The Modification of Standard to Section 4.27(D)(5) that is proposed with this
Project Development Plan meets the applicable requirements of Section
2.8.2(H), in that the granting of the Modification would not be detrimental to
the public good and the proposal submitted promotes the general purpose of
the code standard equal to or better than would a compliant plan.
E. The Project Development Plan complies with relevant standards located in
Division 4.27, Employment (E) of Article 4 — Districts, so long as the board
approves the modifications to Sections 4.27(D)(2) and 4.27(D)(5).
RECOMMENDATION:
Staff recommends that the Planning & Zoning Board make a motion to approve
Worthington Avenue Residences, PDP160023 based on the findings of fact found on
page 17 of the staff report.
ATTACHMENTS:
1. Zoning & Site Vicinity Map
2. Statement of Planning Objectives
3. Applicant's Modification Requests
Staff Report —Worthington ,nue Residences, PDP160023
Planning & Zoning Board 10-13-2016
Page 16
gained preliminary approval from Poudre Fire Authority for meeting all
applicable code requirements.
4. Compliance with Article 4 of the Land Use Code — Division 4.27,
Employment District (E):
The project complies with all applicable Article 4 standards as follows:
A. Section 4.27(B)(3)(a) — Permitted Uses
The proposed use, two-family dwellings, is permitted in the E zone district
and is consistent with the district's intent to be a setting to have a mix of
uses that support primary employment districts.
B. Section 4.27(D)(4)(a) — Maximum Building Height
The maximum building height is four stories. All of the proposed buildings
are one story.
C. Section 4.27(D)(7) — Access to a Park, Central Feature or Gathering Place
90% of the dwellings in a residential development shall be located within
1.4 mile of either a neighborhood park, a privately owned park or a central
feature or gathering place that is located either within the project or within
adjacent development, which distance shall be measured along street
frontage without crossing an arterial street. A privately owned park must
be at least 10,000 square feet, highly visible from streets, open to the
public, and contain a mix of facilities for various age groups to utilize.
The site plan shows a park/community space that is accessible and visible
from the private drive. This park, however, is not 10,000 square feet in
size. This development is within '/4 mile of New Mercer Commons, which
has a 2.49-acre park that is open to the public. With the combination of
having a park on -site and accessibility to the park at New Mercer
Commons, this development meets this code requirement.
5. Public Outreach Summary
The applicant held a neighborhood meeting in accordance with Land Use Code
section 2.2.2. The applicant held the meeting on July 14, 2016 and staff had sent
Staff Report —Worthington h ,we Residences, PDP160023
Planning & Zoning Board 10-13-2016
Page 15
15 feet from the private street with the garages more than 20 feet from
where the driveway meets the sidewalk.
T. Section 3.5.2(E)(3) — Side and Rear Yard Setbacks
For residential buildings, the minimum side yard setback is 5 feet and the
minimum rear yard setback is 8 feet. Each building complies with the 5
foot side yard setback and the 8 foot rear yard setback.
U. Section 3.5.2(F) — Garage Doors
Garage doors should be integrated into the development to prevent the
streetscape from being dominated by protruding garage doors. The
Director may allow alternative garage door treatments if the proposed
structures meet the intent of the code to line streets with active living
spaces, create pedestrian -oriented streetscapes and provide variety and
visual interest in the exterior design of residential buildings per Section
3.5.2(F)(5)(b).
All of the garages recess behind front porches. Each porch exceeds the
minimum required to meet this code section. These porches are not fully
covered, however, and so the garage door treatment must meet the
alternative compliance measures outlined in Section 3.5.2(F)(5)(b).
The proposed garage door treatments meet the intent by lining the street
with generous front porches that extend beyond the garage doors.
Pergolas and low fences define each porch to draw attention to the
outdoor space and front entrance to each duplex. Landscaping lines each
porch, which draws attention away from the garages. All of the garages
feature windows to make each garage door look more integrated into the
building. Due to all of these enhancements, staff finds the proposed plan
to meet this code section.
V. Section 3.6.6 — Emergency Access
All proposed developments shall provide adequate access for emergency
vehicles and for those persons rendering fire protection and emergency
services. The proposed development's emergency access plan has
Staff Report —Worthington ;nue Residences, PDP160023
Planning & Zoning Board 10-13-2016
Page 14
New developments shall be compatible with the established architectural
character of the area. This includes using similar materials, buildings that
are of a similar size, height, bulk, mass, and scale, and minimizing the
infringement on adjacent property owners' privacy.
The Centre for Advanced Technology has an eclectic mix of uses and
structures. All of the buildings along Worthington Circle are between one
and three stories in height. The uses include multi -family residential, a
long-term care facility, medical offices, and general office. Each building
contains sloped roof forms. The surrounding buildings also contain a mix
of materials including brick, lap siding, stucco, and stone.
The proposed buildings fit into this context by being single story, using
sloped roof forms, and using high quality materials such as lap siding,
brick, and cultured stone.
Q. Section 3.5.2(C) — Housing Model Variety Variation Among Buildings
Any development containing fewer than 100 units shall have three
different types of housing models with three characteristics that distinguish
each building from other housing models. The proposed site plan shows
fiver different models. Each model has a different mix of materials, unit
size, porches, entry features, garage configuration, and roof forms to
differentiate them from other models.
R. Section 3.5.2(D) — Relationship of Dwellings to Streets and Parking
Every front door shall face the adjacent street to the extent reasonably
feasible. Alternatively, front doors may face onto a major walkway spine
as long as the front door is no more than 350 feet from a street sidewalk.
Each unit faces the private street and has a walkway that connects the
front door to the sidewalk, which satisfies this requirement.
S. Section 3.5.2(E)(2) — Setbacks from Non -arterial Streets
The minimum setback for residential buildings from non -arterial streets is
15 feet. Garages must be setback at least 20 feet from where the
driveway meets the sidewalk. All of the buildings are setback more than
Staff Report — Worthington r. .we Residences, PDP160023
Planning & Zoning Board 10-13-2016
Page 13
L. Section 3.2.3 —Solar Access, Orientation, Shading
All development shall be designed throughout to accommodate active
and/or passive solar installations to the extent reasonably feasible while
minimizing the casting of shadows onto adjacent developments. All of the
proposed buildings could be retrofitted to handle solar arrays and are
oriented to prevent the casting of shadows onto adjacent developments.
M. Section 3.2.4 — Site Lighting
The proposed lighting plan is consistent with the requirements of the Land
Use Code in regards to the general standard, lighting levels and design
standards.
N. Section 3.4.1(D)(1) — Ecological Characterization Study
Applicants must submit an Ecological Characterization Study (ECS) when
a site contains or is within 500 feet of a natural habitat or feature. The
applicant must submit an ECS at least 10 days before submittal of the
Project Development Plan. This study must show how wildlife uses the
site and the extent of any natural features. Depending on the results of the
ECS, the applicant may need to provide enhancements to the site to
minimize the development's impacts on natural habitat features.
The applicant delivered the ECS 10 days in advance of the Project
Development Plan. The ECS recommends a 50-foot setback from the
Larimer County Canal No. 2 and the New Mercer Ditch, enhanced
plantings in the buffer zone, and to direct lighting away from the buffer
zone. The site plan shows buildings developed outside of the 50-foot
buffer from Larimer County Canal No. 2 and the New Mercer Ditch. The
landscape plan shows cottonwood trees and other plants and shrubs in
the buffer area to provide higher quality habitat for songbirds. The lighting
plan shows that lighting will not spill into the buffer zone. All of these
elements satisfy the recommendations of the ECS and this code standard.
O. Section 3.4.1(E) — Establishment of Buffer Zones
Irrigation ditches and canals require a 50-foot buffer that disallows
disturbances. The site plan shows no disturbances in the buffer zone.
P. Section 3.5.1 — Building and Project Compatibility
Staff Report —Worthington ,nue Residences, PDP160023
Planning & Zoning Board 10-13-2016
Page 12
These walkways allow pedestrians to move within the site without
encountering vehicles or bicycles.
G. Section 3.2.2(C)(5) — Walkways
Walkways must be located and aligned to directly and continuously
connect areas or point of pedestrian origin and destination. Each walkway
shown on the proposed site plan connects to the entry of each duplex.
These walkways connect to the private drive that runs through the site. All
of the walkways lead directly to the sidewalks on Worthington Circle.
H. Section 3.2.2(C)(6) — Direct On -Site Access to Pedestrian and Bicycle
Destinations
Pedestrian and bicycle facilities provided on site must connect to or allow
for direct connections to major pedestrian and bicycle destinations. The
sidewalk network connects to the sidewalks on Worthington Circle, which
provide direct connections to major destinations.
Section 3.2.2(C)(8) — Transportation Impact Study
A Transportation Impact Study is required for developments that could
have an impact on the traffic conditions surrounding the development.
The applicant supplied a Transportation Impact Study in accordance with
the City's guidelines. The study showed that the project meets the City's
level of service requirements for all modes of transportation.
J. Section 3.2.2(D) — Access and Parking Lot Requirements
The proposal meets the requirements outlined in Land Use Code section
3.2.2(D) including the separation of vehicles and pedestrians,
unobstructed vehicle access, location of off-street parking areas,
pavement material, and lighting.
K. Section 3.2.2(K) — Parking Lots — Required Number of Off -Street Spaces
for Type of Use
Two bedroom units require 1.75 parking spaces per unit minimum. For a
34-unit development, 60 parking spaces are required. Each unit has a 1-
or 2-car garage. All of the garages in the development provide 53 parking
spaces. The development also has nine surface parking spaces for
guests. This results in 62 parking spaces for the whole development.
Staff Report —Worthington r. .oue Residences, PDP160023
Planning & Zoning Board 10-13-2016
Page 11
C. Section 3.2.1(D)(3) — Minimum Species Diversity
To prevent uniform insect or disease susceptibility and eventual uniform
senescence on a development site or in the adjacent area or the district,
species diversity is required and extensive monocultures are prohibited.
The maximum percentage of any one species when there are 60 or more
trees on site is 15%. No species consists of more than 15% of the overall
amount of trees provided.
D. Section 3.2.1(D)(4) — Tree Species and Minimum Sizes
All trees provided must meet the minimum sizes as follows:
Typ e
Minimum Size
Canopy Shade Tree
2.0" caliper balled and burlapped or
equivalent
Evergreen Tree
6.0' height balled and burlapped or
equivalent
Ornamental Tree
1.5" caliper balled and burlapped or
equivalent
Shrubs
5 gallon or adequate size consistent
with design intent
Canopy Shade Tree as a street tree
1.25" caliper container or equivalent
on a Residential Local Street Only
The trees shown on the landscape all meet these minimum requirements.
E. Section 3.2.1(E)(3) — Water Conservation
All landscape plans must be designed to incorporate water conservation
materials and techniques in order to meet the Xeriscape principals
established in the Land Use Code. Total annual water use shall not
exceed 15 gallons/square foot over the site. The landscape plan meets
the Xeriscape principals in the Land Use Code and has an annual water
use of 3.9 gallons/square foot over the site.
F. Section 3.2.2(C)(1) — Safety Considerations
To the maximum extent feasible, pedestrians shall be separated from
vehicles and bicycles. The proposed development will have an extensive
system of sidewalks and walkways separated from the roadway by a curb.
Staff Report —Worthington. nue Residences, PDP160023
Planning & Zoning Board 10-13-2016
Page 10
in difficulty achieving other code requirements such as building setbacks and
buffer distance from natural features.
Worthington Avenue Residences also fits into the Centre for Advanced
Technology well with the proposed density of the project. Most of the Centre for
Advanced Technology around Worthington Ave. features short buildings with
ample open space. All of the surrounding buildings range from one story to three
stories in height with green space to serve each development. The proposed
Worthington Avenue Residences fits this context with its emphasis on shared
open space and ranch style homes.
As discussed in the previous modification request, this project will help meet a
defined community need in City Plan. Without this modification request, the
design of the development would be compromised from the end user's
perspective. One-story buildings function better for seniors. This development's
proximity to health care services makes it an ideal site for senior housing. This
development also fits in with the established context of the area at the proposed
density. For these reasons, staff finds the modification request is justified.
3. Compliance with Article 3 of the Land Use Code — General Development
Standards:
The project complies with all applicable General Development Standards as
follows:
A. Section 3.2.1(D) — Tree Planting Standards
All developments must establish groves and belts of trees along all city
streets, in and around parking lots, and in all landscape areas that are
located within 50 feet of any building or structure in order to establish at
least a partial urban tree canopy. The proposed landscape plan shows
trees that line the private drive that runs through the development that will
provide a tree canopy along the street and near each building.
B. Section 3.2.1(D)(2) — Street Trees
Developments that front on streets with a landscape parkway must
provide canopy shade trees at 30-40 foot spacing in the center of such
parkway areas. The proposed landscape plan shows canopy shade trees
along the private drive and the entrance to the development from
Worthington Circle.
Staff Report — Worthington �, oue Residences, PDP160023
Planning & Zoning Board 10-13-2016
Page 9
equally well or better than would a plan which complies with the standard for
which a modification is requested, and
C. The project design satisfies 2.8.2(H)(2): the granting of a modification from
the strict application of any standard would, without impairing the intent and
purpose of this Land Use Code, substantially alleviate an existing, defined
and described problem of city-wide concern or would result in a substantial
benefit to the city by reason of the fact that the proposed project would
substantially address an important community need specifically and expressly
defined and described in the City's Comprehensive Plan or in an adopted
policy, ordinance or resolution of the City Council, and the strict application of
such a standard would render the project practically infeasible.
The purpose for the minimum density requirement in the Employment zone is to
ensure a consistent character between different uses. Most primary uses will
have a more dense character than developments typical of a neighborhood with
mainly single-family houses. This minimum density requirement falls between the
maximum allowed in the Low Density Mixed -Use Neighborhood (LMN) and
Medium Density Mixed -Use Neighborhood (MMN) zone districts. This allows for
flexibility on residential density depending on the context. Some business parks
are suburban in character and amenable to lower -density residential
development. Others feature taller structures and a denser character and would
lend themselves better to a dense residential development.
To meet the minimum density requirement, Worthington Avenue Residences
would have to provide at least 36 dwelling units. The proposed plan shows 34
units in one-story buildings. A compliant plan could utilize the height allowances
of the Employment zone to provide multi -family dwellings containing apartments
or condominiums. A compliant plan could also feature townhomes with more than
two units to achieve the minimum density of the zone district. Worthington
Avenue Residences could achieve compliance but the question is would these
compliant plans serve the end user better than what is proposed given the
context of the site?
The target demographic for these homes is seniors aged 55 and over. As such,
Worthington Avenue Residences shows single story buildings to prevent
residents from climbing up and down stairs. While this serves the residents better
than multi -story buildings, this design choice reduces the density of the project.
The site could accommodate two additional units but this introduces tradeoffs. A
greater number of units with a similar configuration would result in less open
space. Adding two units would likely result in reducing unit size and would result
Staff Report —Worthington . :nue Residences, PDP160023
Planning & Zoning Board 10-13-2016
Page 8
Summary of Applicant's Justification:
The applicant requests that the Modification be approved and provides the
following justification based upon Criterion 1 (proposal is equal or better than
provisions in the Land Use Code) and Criterion 2 (proposal will help address a
community need specifically described in the city's Comprehensive Plan):
• The proposed alternative plan seeks to provide a substantial benefit to the
City by addressing an important community need specifically and
expressly defined and described in the policies of the February 2011 City
Plan:
Policy LIV 7.5 — Address Special Needs Housing
o Plan for and meet the housing needs of special populations within
the community. Disperse residential care facilities, shelters, group
homes, and senior housing throughout the Growth Management
Area.
o The proposed plan is in a location that is desirable for housing
targeting older adults due to its proximity to the existing Columbine
Health Campus. This project will provide opportunities for
convenient living for this demographic.
o The proposed alternative plan continues to improve the design,
quality and character of new development by exceeding the
building standards set forth in Section 3.5. The use of high quality
residential building materials, building articulation, projections and
recesses, along with pitched roof elements ensures sensitivity to
and compatibility with the surrounding neighborhood.
o The site is encumbered on all four sides by irrigation ditches and a
detention pond. In addition, there is a requirement for 10,000
square feet for a park, central feature or gathering area. Therefore,
out of the 8.157 acres, only 5.01 acres are usable for the
development of the buildings and streets. This equates to 6.71
dwelling units per acre, which is short by .29 dwelling units per
acre.
Staff Finding:
Staff finds that the request for a Modification of Standard to section 4.27(D)(2) is
justified by the applicable standards in 2.8.2(H)(1) and 2.8.2(H)(2).
A. The granting of the Modification would not be detrimental to the public good;
B. The project design satisfies 2.8.2(H)(1): the plan as submitted will promote
the general purpose of the standard for which the modification is requested
Staff Report —Worthington, .oue Residences, PDP160023
Planning & Zoning Board 10-13-2016
Page 7
zone district, which states, "This District also is intended to accommodate
secondary uses that complement or support the primary workplace uses..."
Since this development would support the primary uses surrounding,
Worthington Avenue Residences meets the intent of this code section.
Worthington Avenue Residences will also help address a defined, community
wide need identified in City Plan. City Plan discusses senior housing as a
community wide need in Policy LIV 7.5. The Fort Collins Social Sustainability
Gaps Analysis from 2014 also notes that the population of seniors in the
community will grow rapidly in the coming years. The Gaps Analysis projects the
number of seniors in Fort Collins to double by 2030. Fewer seniors live in an
institutionalized setting, furthermore, which means more seniors will require
additional housing arrangements/options as the senior population grows. Only
1 % of 65-74 year olds live in an institutionalized setting per the Gaps Analysis.
Since this community will be targeted towards individuals aged 55 and older,
Worthington Avenue Residences will help fulfill a community wide need.
Staff finds that by supporting the primary uses in the district and addressing a
defined, community wide need that the modification is justified by criteria 1 and 2.
Modification #2 Description:
The applicant requests a Modification to Section 4.27(D)(5) — Density/Intensity to
pursue a development below the minimum net density required of 7 dwelling
units per acre.
Land Use Code Standard Proposed to be Modified (areas underlined and
bolded for emphasis):
Land Use Code 4.27(D)(5):
All residential development in the E Employment District shall have an overall
minimum average density of seven (7) dwelling units per net acre of
residential land.
Staff Report —Worthington . :nue Residences, PDP160023
Planning & Zoning Board 10-13-2016
Page 6
pitched roof elements ensures sensitivity to and compatibility with the
surrounding neighborhood.
Staff Finding:
Staff finds that the request for a Modification of Standard to section 4.27(D)(2) is
justified by the applicable standards in 2.8.2(H)(1) and 2.8.2(H)(2).
A. The granting of the Modification would not be detrimental to the public
good;
B. The project design satisfies 2.8.2(H)(1): the plan as submitted will promote
the general purpose of the standard for which the modification is
requested equally well or better than would a plan which complies with the
standard for which a modification is requested, and
C. The project design satisfies 2.8.2(H)(2): the granting of a modification from
the strict application of any standard would, without impairing the intent
and purpose of this Land Use Code, substantially alleviate an existing,
defined and described problem of city-wide concern or would result in a
substantial benefit to the city by reason of the fact that the proposed
project would substantially address an important community need
specifically and expressly defined and described in the City's
Comprehensive Plan or in an adopted policy, ordinance or resolution of
the City Council, and the strict application of such a standard would render
the project practically infeasible
The intent of this code standard is to allow for a mix of uses while retaining a
character predominated by primary employment uses. Staff has interpreted the
25% maximum secondary use regulation to apply to the Employment district as a
whole rather than just at the level of an individual development plan. Currently,
the Centre for Advanced Technology contains 22.1% secondary uses. While
Worthington Avenue Residences will consist of 100% secondary uses, the
overall Centre for Advanced Technology will only contain 25.8% secondary uses
if the Planning & Zoning Board approves this project.
Context is critical when determining the appropriate primary/secondary use split
for an Employment district. In this particular context, many of the primary
employers are health care providers. Most of these health care providers serve
elderly individuals that are able to live independently but require regular care. As
such, an appropriate secondary use for this area would be residential uses
targeted towards seniors. Worthington Avenue Residencess is a senior oriented
residential project in close proximity to health care providers. This is an
appropriate secondary use in line with the purpose statement of the Employment
Staff Report —Worthington t.. _nue Residences, PDP160023
Planning & Zoning Board 10-13-2016
Page 5
physical conditions such as exceptional narrowness, shallowness or topography,
or physical conditions which hinder the owner's ability to install a solar energy
system, the strict application of the standard sought to be modified would result
in unusual and exceptional practical difficulties, or exceptional or undue hardship
upon the owner of such property, provided that such difficulties or hardship are
not caused by the act or omission of the applicant; or
(4) the plan as submitted will not diverge from the standards of the Land Use
Code that are authorized by this Division to be modified except in a nominal,
inconsequential way when considered from the perspective of the entire
development plan, and will continue to advance the purposes of the Land Use
Code as contained in Section 1.2.2.
Any finding made under subparagraph (1), (2), (3) or (4) above shall be
supported by specific findings showing how the plan, as submitted, meets the
requirements and criteria of said subparagraph (1), (2), (3) or (4).
Summary of Applicant's Justification:
The applicant requests that the Modification be approved and provides the
following justification based upon Criterion 1 (proposal is equal or better than
provisions in the Land Use Code) and Criterion 2 (proposal will help address a
community need specifically described in the City's Comprehensive Plan):
Applicant's Justification:
• The proposed alternative plan seeks to provide a substantial benefit to the
City by addressing an important community need specifically and
expressly defined and described in the policies of the February 2011 City
Plan:
Policy LIV 7.5 — Address Special Needs Housing
Plan for and meet the housing needs of special populations within the
community. Disperse residential care facilities, shelters, group homes, and
senior housing throughout the Growth Management Area.
• The proposed plan is in a location that is desirable for housing targeting
older adults due to its proximity to the existing Columbine Health Campus.
This project will provide opportunities for convenient living for this
demographic.
• The proposed alternative plan continues to improve the design, quality
and character of new development by exceeding the building standards
set forth in Section 3.5. The use of high quality residential building
materials, building articulation, projections and recesses, along with
Staff Report —Worthington nue Residences, PDP160023
Planning & Zoning Board 10-13-2016
Page 4
2. Compliance with Section 2.8.2(H) of the Land Use Code - Modification of
Standards
Modification #1 Description:
The applicant requests a Modification to Section 4.27(D)(2) — Secondary Uses to
pursue a development with 100% secondary uses.
Land Use Code Standard Proposed to be Modified (areas underlined and
bolded for emphasis):
Land Use Code 4.27(D)(2):
All secondary uses shall be integrated both in function and appearance
into a larger employment district development plan that emphasizes
primary uses. A secondary use shall be subject to administrative review or
Planning and Zoning Board review as required for such use in Section
4.27(B). The following permitted uses shall be considered secondary
uses in this zone district and together shall occupy no more than
twenty-five (25) percent of the total gross area of the development
plan ... (d) Residential uses (except mixed -use dwellings when the
residential units are stacked above a primary use which occupies the
_ground floor).
Land Use Code Modification Criteria:
"The decision maker may grant a modification of standards only if it finds that the
granting of the modification would not be detrimental to the public good, and that:
(1) the plan as submitted will promote the general purpose of the standard for
which the modification is requested equally well or better than would a plan which
complies with the standard for which a modification is requested; or
(2) the granting of a modification from the strict application of any standard
would, without impairing the intent and purpose of this Land Use Code,
substantially alleviate an existing, defined and described problem of city-wide
concern or would result in a substantial benefit to the city by reason of the fact
that the proposed project would substantially address an important community
need specifically and expressly defined and described in the city's
Comprehensive Plan or in an adopted policy, ordinance or resolution of the City
Council, and the strict application of such a standard would render the project
practically infeasible; or
(3) by reason of exceptional physical conditions or other extraordinary and
exceptional situations, unique to such property, including, but not limited to,
Staff Report — Worthington , nue Residences, PDP160023
Planning & Zoning Board 10-13-2016
Page 3
Staff Report —Worthington nue Residences, PDP160023
Planning & Zoning Board 10-13-2016
Page 2
• The Project Development Plan complies with relevant standards of Article 3 —
General Development Standards.
• The Modification of Standard to Section 4.27(D)(2) that is proposed with this
Project Development Plan meets the applicable requirements of Section
2.8.2(H), in that the granting of the Modification would not be detrimental to the
public good and the proposal submitted promotes the general purpose of the
code standard equal to or better than would a compliant plan.
• The Modification of Standard to Section 4.27(D)(5) that is proposed with this
Project Development Plan meets the applicable requirements of Section
2.8.2(H), in that the granting of the Modification would not be detrimental to the
public good and the proposal submitted promotes the general purpose of the
code standard equal to or better than would a compliant plan.
• The Project Development Plan complies with relevant standards located in
Division 4.27, Employment (E) of Article 4 — Districts, so long as the board
approves the modifications to Sections 4.27(D)(2) and 4.27(D)(5).
COMMENTS:
1. Background
The property was annexed into the City of Fort Collins as part of the College Fourth
Annexation in September 1965. The parcel was included as Parcel B on the CSURF
Centre for Advanced Technology Overall Development Plan (ODP) in February 2003.
The parcel has since sat vacant.
The surrounding zoning and land uses are as follows:
Direction
Zone District
Existing Land Uses
North
Medium Density Mixed -Use
Neighborhood MMN
Multi -family
South
Employment (E), Neighborhood
Commercial (NC)
Multi -family, medical office, office, retail,
restaurant
East
Employment (E)
Vacant
West
Employment (E)
Multi -family, medical office
The next page contains a zoning and site vicinity map.
City of
Fort Coltins
MEETING DATE
STAFF
Oct. 13, 2016
ClaV FrickeV
PLANNING & ZONING BOARD
PROJECT: Worthington Avenue Residences, PDP160023
APPLICANT: Cathy Mathis
TB Group
444 Mountain Ave.
Berthoud, CO 80526
OWNERS: Colorado State University Research Foundation
2537 Research Blvd.
Fort Collins, CO 80526
PROJECT DESCRIPTION:
This is a request for a Project Development Plan to develop 34 single- family attached
living units in 17 buildings with the objective of creating a synergy with the Columbine
Health Systems surrounding development and to create a campus for an aging- in place
senior community. The units range in size from 1460 square feet to 1640 square feet.
The duplex homes will be targeted toward a 55-65 year old population, with full services
available such as nurse calls and home health care provided by Columbine Health
Systems. The development will consist of 1- and 2-bedroom units with attached 1- and
2-car garages. 9 guest parking spaces will be available. A central park/ gathering area
will be accessed by walk -able pathways throughout the development. The 8.15-acre site
is located on Parcel B of the Centre for Advanced Technology ODP, north of
Worthington Circle. The site is zoned (E) Employment.
RECOMMENDATION: Staff recommends the Planning & Zoning Board approve
Worthington Avenue Residences, PDP160023.
EXECUTIVE SUMMARY:
Staff finds the proposed Worthington Avenue Residences Project Development Plan
complies with the applicable requirements of the City of Fort Collins Land Use Code
(LUC), more specifically:
• The Project Development Plan complies with the process located in Division 2.2
— Common Development Review Procedures for Development Applications of
Article 2 — Administration.
Planning Services 281 N College Ave — PO Box 580 — Fort Collins, CO 80522-0580
fcgov.com/developmentreview/ 970.221.6750