Loading...
HomeMy WebLinkAboutNORTH COLLEGE DRIVE THRU - PDP - PDP160014 - REPORTS - RECOMMENDATION/REPORT W/ATTACHMENTSAttachment 6 IV. CONCLUSIONS/RECOMMENDATIONS This study assessed the impacts of the 1603 & 1605 North College development on the short range (2021) street system in the vicinity of the proposed development. As a result of this analysis, the following is concluded: • The development of the 1603 & 1605 North College site is feasible from a traffic engineering standpoint. At full development, the 1603 & 1605 North College site will generate approximately 1240 daily weekday trip ends, 113 morning peak hour trip ends, and 82 afternoon peak hour trip ends. • Current operation at the North College/Willox and North College/Driveway intersections is acceptable with existing control, geometry, and signal timing. • Figure 10 shows a schematic of the short range (2021) geometry. It is important to note that a southbound right -turn deceleration lane at the North College/Site Access intersection is warranted with the short range (2021) total traffic volumes. Requirement of this auxiliary lane rests with the City of Fort Collins and CDOT. • In the short range (2021) future, given development of the 1603 & 1605 North College site and an increase in background traffic, the North College/Willox and North College/Site Access intersections will meet the City of Fort Collins Motor Vehicle LOS Standard, the warranted auxiliary lane. The increase in delay at the North College/Site Access intersection without the warranted auxiliary right -turn lane will not be significant. • Acceptable level of service is achieved for bicycle, and transit modes based upon the measures in the multi -modal transportation guidelines. Pedestrian level of service is achieved for all areas except for the residential neighborhood to the west of the site. This mobile home park was constructed without sidewalks. // LDELICH 1603 & 1605 North College TIS, April 2016 -7,1 [-ASSOCIATES Page 21 Attachment 6 TABLE 4 Short Range (2021) Total Peak Hour Operation Intersection Movement Level of Service AM PM North College/Willox (signal) EB LT C C EB T D C EB RT A A EB APPROACH C C WB LT C C WBT C D WB RT A C WB APPROACH C C NB LT A A NB T A B NB RT A B NB APPROACH A B SB LT A A SB T B B SIB RT A A SB APPROACH B B OVERALL B B North College/Site Access (RT-in/RT-out) EB RT B B —//'DELICH 1603 & 1605 North College TIS, April 2016 -71 rASSOCIATES Page 20 Attachment 6 Using the traffic volumes shown in Figure 9, the North College/Willox and North College/Site Access intersections operate in the short range (2021) total condition as indicated in Table 4. Calculation forms for these analyses are provided in Appendix E. The key intersections operate similar to the background operation with existing geometry, control, and signal timing in the morning and afternoon peak hours. The increase in delay at the North College/Site Access intersection without the warranted auxiliary right -turn lane will not be significant. Pedestrian Level of Service Appendix F shows a map of the area that is within 1320 feet of the 1603 & 1605 North College development. There are four pedestrian destinations within 1320 feet of the 1603 & 1605 North College development. These are: 1) the commercial area to the north of the site; 2) the commercial area to the east and northeast of the site; 3) the commercial uses to the south of the site; and 4) the residential neighborhood to the west of the site. The 1603 & 1605 North College site is located within an area termed as "activity center," which sets the level of service threshold at LOS B for all measured categories, except for street crossing which is LOS C. The Pedestrian LOS Worksheet is provided in Appendix F. Pedestrian level of service is achieved for all areas except 4) the residential neighborhood to the west of the site. This mobile home park was constructed without sidewalks. If this parcel redevelops, it is assumed that a new development would construct sidewalks. Bicycle Level of Service Appendix F shows a map of the area that is within 1320 feet of the 1603 & 1605 North College development. There are three bicycle destinations within 1320 feet of the 1603 & 1605 North College development. These are: 1) the commercial area to the north of the site; 2) the commercial area to the east and northeast of the site; and 3) the commercial uses to the south of the site. The Bicycle LOS Worksheet is provided in Appendix F. The minimum level of service for this site is C. This site is connected to bike lanes on North College Avenue and Willox Lane. Therefore, it is concluded that level of service C can be achieved. Transit Level of Service This area of Fort Collins is served by Transfort Routes 8 and 81. —// LDELICH 1603 & 1605 North College TIS, April 2016 -7,1 [-ASSOCIATES Page 19 Attachment 6 TABLE 3 Short Range (2021) Background Peak Hour Operation Intersection Movement Level of Service AM PM North College/Willox (signal) EB LT C C EB T D C EB RT A A EB APPROACH C C W B LT C C WBT C D W B RT A C WB APPROACH C C NB LT A A NB T A B NB RT A B NB APPROACH A B SB LT A A SB T B B SB RT A A SB APPROACH A B OVERALL B B North College/Driveway (RT-in/RT-out) EB RT B B --// i—DELICH 1603 & 1605 North College TIS, April 2016 -7,1 [—ASSOCIATES Page 18 Attachment 6 Willox Site Access - Existing Lane - Required Lane SHORT RANGE (2021) GEOMETRY N Figure 10 --/1 J DELICH -7 , I —ASSOCIATES 1603 & 1605 North College TIS, April 2016 Page 17 Attachment 6 Willox I,. u') o Co tz m o rn o / 1 721117 96/134 122/92 Site Access 61/54 U t 0 0 z 72/250 70/166 86/135 00 w 0 uO LO AM/PM SHORT RANGE (2021) TOTAL PEAK HOUR TRAFFIC N Figure 9 --// f DELICH 1603 & 1605 North College TIS, April 2016 1 rASSOCIATES Page 16 Attachment 6 LO co 1 � 6/5 Willox 3/2 � n� r IN N 6 V Site Access 55/39 t IN M --w— AM/PM SITE GENERATED PEAK HOUR TRAFFIC N Figure 8 —// L—DELICH —71 [—ASSOCIATES 1603 & 1605 North College TIS, April 2016 Page 15 Attachment 6 Trip Assignment Trip assignment is how the generated and distributed trips are expected to be loaded on the street system. The assigned trips are the resultant of the trip distribution process. Using the trip distribution shown in Figure 6, Figure 8 shows the assignment of the site generated peak hour vehicle traffic. Passby factors were applied according to The Trip Generation Handbook, ITE and distributed based upon the existing directional split on North College Avenue. The passby and assigned site traffic is reflected in Figure 8. The site generated vehicle traffic was combined with the background traffic to determine the total forecasted vehicle traffic at the key intersections. Figure 9 shows the short range (2021) total peak hour vehicle traffic at the key intersections. Signal Warrants As a matter of policy, traffic signals are not installed at any location unless warrants are met according to the Manual on Uniform Traffic Control Devices. The North College/Willox intersection is currently signalized. The North College/Site Access intersection will not meet peak hour signal warrants, nor do the two intersections meet signal spacing criteria. Geometry Figure 10 shows a schematic of the short range (2021) geometry. A southbound right -turn deceleration lane is shown to be warranted at the North College/Site Access intersection. The right -turn lane is required based upon the CDOT State Highway Access Code and LCUASS criteria. The CDOT criterion requires a right -turn lane at more than 50 vehicles per hour (right-tums). This is exceeded by 26 and 5 vehicles in the respective peak hours. Utilizing Figure 8-4 (LCUASS), the threshold requiring a right-tum lane is exceeded by 35 and 12 vehicles in the respective peak hours. Based upon the recent street improvements on North College Avenue, it is not known whether this right-tum lane will be required. That decision rests with the City of Fort Collins and CDOT. Operation Analysis Operation analyses were performed at the North College/Willox and North College/Site Access intersections. The operation analyses were conducted for the short range analysis, reflecting a year 2021 condition. The current City signal timing was used for the North College/Willox intersection. The following analyses reflect the warranted right -turn deceleration lane at the North College/Driveway intersection. Using the short range (2021) background peak hour traffic volumes, the North College/Willox and North College/Driveway intersections operate as indicated in Table 3. The key intersections operate acceptably with existing control, geometry, and signal timing in the morning and afternoon peak hours. Calculation forms for these analyses are provided in Appendix D. --/y LDELICH 1603 & 1605 North College TIS, April 2016 -7,1 I —ASSOCIATES Page 14 Attachment 6 N lA O C0 o 00 0 a� m 0 U L 0 O Z 72/250 --a— 70/166 80/130 Willox 72/117 J I( 96/134 Co Co 119/90LO C Lo Co cc Driveway 6/15 0 0 rn v AM/PM SHORT RANGE (2021) BACKGROUND PEAK HOUR TRAFFIC d Figure 7 —// L—DELICH 1603 & 1605 North College TIS, April 2016 -7/ [—ASSOCIATES Page 13 Attachment 6 N 0 0 N 10% 20% H � � WIIIOX ------------ O O 01 N O U r 0 z SCALE: V=600' TRIP DISTRIBUTION Figure 6 —/I I DELICH 1603 & 1605 North College TIS, April 2016 % 1 —ASSOCIATES Page 12 Atta hment 6 SCALE: 1"=30' . - !1 �4 - 500 s.f. Fastfo with drive thru DRIVETHRU -� BIOSWALE NNW- �. e SITE PLAN !!A Figure 5 _—// I DELICH -71 [--ASSOCIATES 1603 & 1605 North College TIS, April 2016 Page 11 Attachment 6 III. PROPOSED DEVELOPMENT The 1603 & 1605 North College development is a proposed fast-food restaurant development. Figure 5 shows a site plan of the 1603 & 1605 North College development. Access to the 1603 & 1605 North College site will be via an existing right- in/right-out access to/from North College Avenue. The short range analysis (Year 2021) includes development of the 1603 & 1605 North College site and an appropriate increase in background traffic, due to normal growth, and other approved or expected developments in the area. Trip Generation Trip generation is important in considering the impact of a development such as this upon the existing and proposed street system. A compilation of trip generation information contained in Trip Generation, gth Edition, ITE was used to estimate trips that would be generated by the 1603 & 1605 North College project. Land Use Code 934 — Fast -Food Restaurant with Drive -through was used for the trip generation calculation. Table 2 shows the daily and peak hour trip generation for 1603 & 1605 North College project. Full development of the 1603 & 1605 North College site resulted in 1240 daily weekday trip ends, 113 morning peak hour trip ends, and 82 afternoon peak hour trip ends. TABLE 2 Trip Generation AWDTE AM Peak Hour PM Peak Hour Code Use Size Rate Trips Rate In Rate Out Rate In Rate Out 934 Fast -Food 2.5 KSF 496.12 1240 23.16 58 22.20 55 16.98 43 15.67 39 Restaurant Trip Distribution Trip distribution for the 1603 & 1605 North College development was based on existing/future travel patterns, land uses in the area, consideration of trip attractions/ productions in the area, and engineering judgment. Figure 6 shows the trip distribution for the short range (2021) analysis future. The trip distribution was agreed to by City of Fort Collins staff in the scoping emails. Background Traffic Projections Figure 7 shows the short range (2021) background peak hour traffic projections. Background traffic projections for the short range were obtained by reviewing the North Front Range Regional Transportation Plan, and engineering judgment. Based upon these sources, it was determined that the traffic volumes would increase by approximately 1.0 percent per year. —// I DELICH 1603 & 1605 North College TIS, April 2016 -71 [—ASSOCIATES Page 10 Attachment 6 Bicycle Facilities Bicycle lanes exist along North College Avenue and Willox Lane within the study area. Transit Facilities Currently, this area of Fort Collins is served by Transfort routes 8 and 81. —// LDELICH 1603 & 1605 North College TIS, April 2016 -71 [—ASSOCIATES Page 9 Attachment 6 TABLE 1 Current Peak Hour Operation Intersection Movement Level of Service — AM PM North College/Willox (signal) EB LT C C EB T D C EB RT A A EB APPROACH C C W B LT C C WBT C D W B RT A C WB APPROACH C C NB LT A A NB T A B NB RT A B NB APPROACH A B SB LT A A SB T A B SB RT A A SB APPROACH A B OVERALL B B North College/Driveway (RT-in/RT-out) EB RT B B --/J l---DELICH 1603 & 1605 North College TIS, April 2016 -7,1 [—ASSOCIATES Page 8 Attachment 6 N m 0 U L 0 O N CCG O Z (D CO CD69/239 a) r °' f 67/159 76/123 Willox 69/111 / 92/128 — I( r) r, rn 114/86 LO M W v Driveway 6/15 0 0 M ti v f AM/PM FACTORED/BALANCED RECENT PEAK HOUR TRAFFIC Figure 4 --/I L—DELICH 1603 & 1605 North College TIS, April 2016 %,1 [—ASSOCIATES Page 7 Attachment 6 m 0 U r C N 0 Z u7 Ln O `—° o 67/232 65/154 65/114 Willox 67l108 f 89/124 — 97/79 V N LO M Driveway 6/15 f LO Co 0 c') ti f AM/PM RECENT PEAK HOUR TRAFFIC Figure 3 _—// I DELICH 1603 & 1605 North College TIS, April 2016 % ,1 [—ASSOCIATES Page 6 Attachment 6 Existing Traffic Figure 3 shows recent peak hour traffic counts at the North College/Willox and North College/Driveway intersections. The traffic counts at the North Collegemillox intersection were obtained in July 2013 by the City of Fort Collins. Since there is a closure on the west leg of Willox Lane (bridge out), these traffic counts were deemed to be appropriate. The traffic counts at the North College/Driveway intersection were obtained in March 2016. This driveway is located approximately 450 feet south of Willox Lane. Raw traffic count data is provided in Appendix B. Since the counts were done in different years, the counts at the North College/Willox intersection were factored up to reflect a year 2016 condition. The volumes between the two intersections were then balanced. The factored/balanced recent peak hour traffic is shown in Figure 4. Existing Operation The North College/Willox and North College/Driveway intersections were evaluated using techniques provided in the 2010 Highway Capacity Manual. Calculation forms are provided in Appendix C. Using the morning and afternoon peak hour traffic shown in Figure 4, the peak hour operation is shown in Table 1. The current City signal timing was used for the North College/Willox intersection. A description of level of service for signalized and unsignalized intersections from the 2010 Highway Capacity Manual is provided in Appendix C. Table 4-3 (revised per staff comments regarding type of intersection) showing the Fort Collins Motor Vehicle LOS Standards (Intersections) are also provided in Appendix C. This site is in an area termed "Community Commercial District" on the Fort Collins Structure Plan. The North College/Willox intersection is assumed to be in an area termed "Commercial Corridor." In areas termed "Commercial Corridor," acceptable overall operation at signalized intersections during the peak hours is defined as level of service D or better. At signalized intersections, acceptable operation of any leg and any movement is level of service E. At arterial/arterial and arterial/collector or local stop sign controlled intersections, there is no acceptable level of service indicated. The North College/Willox and North College/Driveway intersections will meet the City of Fort Collins Motor Vehicle LOS Standard during in the morning and afternoon peak hours. Pedestrian Facilities There are sidewalks along the east side of North College Avenue and along Willox Lane, east of North College Avenue. There are sidewalks along the south side of Willox Lane, west of North College Avenue, and along both sides of North College Avenue. This area of North College Avenue has been under construction with the North College Improvements. —/y LDELICH 1603 & 1605 North College TIS, April 2016 % 1 [-ASSOCIATES Page 5 Attachment 6 Willox Driveway -u -as - Denotes Lane EXISTING INTERSECTION GEOMETRY N Figure 2 --// I DELICH 1603 & 1605 North College TIS, April 2016 - FASSOCIATES Page 4 Attachment 6 Willox 1603 & 1605 y North Colleg L m m E a� y O J U r 0 z Vine SCALE: 1 "=2000' SITE LOCATION Figure 1 --//LDELICH -7,1 rASSOCIATES 1603 & 1605 North College TIS, April 2016 Page 3 Attachment 6 II. EXISTING CONDITIONS The location of the 1603 & 1605 North College development is shown in Figure 1. It is important that a thorough understanding of the existing conditions be presented. Land Use Land uses in the area are primarily commercial and residential. There are residential uses to the west of the site. There are commercial uses to the north, south, and east of the site. The center of Fort Collins lies to the south of the proposed 1603 & 1605 North College site. Land adjacent to the site is flat (<2% grade) from a traffic operations perspective. Roads The primary streets near the 1603 & 1605 North College site are North College Avenue and Willox Lane. The existing geometry at the key intersections is shown in Figure 2. North College Avenue is to the east of (adjacent to) of the proposed 1603 & 1605 North College site. It is a north -south street classified as a four -lane arterial according to the Fort Collins Master Street Plan and an NRB category highway according to CDOT. North College Avenue has recently been improved. Currently, North College Avenue has a four -lane cross section with a raised center median. At the North College/Willox intersection, North College Avenue has northbound and southbound left - turn lanes, two through lanes in each direction, and northbound and southbound right - turn lanes. The North College/Willox intersection has signal control. The posted speed limit in this area of North College Avenue is 40 mph. South of Willox Lane, on the west side of North College Avenue, there is a 12-foot wide lane (10 feet plus 2 foot gutter pan) that is designated as a bike lane. Given this width, it also functions as a right -turn lane for the access to the Conoco/McDonalds site in the southwest quadrant of the North College/Willox intersection. South of the access, the curb/gutter tapers to become a standard bike lane to the south (adjacent to the existing car wash/storage use and beyond). There is an 8-foot sidewalk, parkway, and street light standards in this area. Willox Lane is to the north of the proposed 1603 & 1605 North College site. It is an east -west street classified as a two-lane arterial according to the Fort Collins Master Street Plan. Currently, Willox Lane has a two-lane cross section with a center median lane. At the North College/Willox intersection, Willox Lane has eastbound and westbound left -turn lanes, one through lane in each direction, and eastbound and westbound right -turn lanes. The posted speed limit in this area of Willox Lane is 30 mph. --/! LDELICH 1603 & 1605 North College TIS, April 2016 -71 [—ASSOCIATES Page 2 Attachment 6 I. INTRODUCTION This intermediate transportation impact study (TIS) addresses the capacity, geometric, and control requirements at and near the proposed 1603 & 1605 North College development. The proposed 1603 & 1605 North College development is located south of Willox Lane and west of (adjacent to) North College Avenue in Fort Collins, Colorado. During the course of the analysis, numerous contacts were made with the owner/developer (Peak to Peak Properties), the project planner (Ripley Design, Inc.) and the Fort Collins Traffic Engineering staff. This study generally conforms to the format set forth in the Fort Collins transportation impact study guidelines contained in the "Larimer County Urban Area Street Standards" (LCUASS). Appendix A contains the Transportation Impact Study Base Assumptions form and related attachments for the 1603 & 1605 North College development. The study involved the following steps: • Collect physical, traffic, and development data; • Perform trip generation, trip distribution, and trip assignment; • Determine peak hour traffic volumes; • Conduct capacity and operational level of service analyses on key intersections; • Analyze signal warrants; • Conduct level of service evaluation of pedestrian, bicycle, and transit modes of transportation. —// it DELICH 1603 & 1605 North College TIS, April 2016 1 [—ASSOCIATES Page 1 Attachment 6 LIST OF FIGURES 1. Site Location............................................................................................................. 3 2. Existing Intersection Geometry ..................................................................................4 3. Recent Peak Hour Traffic.......................................................................................... 6 4. Balanced/Adjusted Recent Peak Hour Traffic........................................................... 7 5. Site Plan.................................................................................................................. 11 6. Trip Distribution....................................................................................................... 12 7. Short Range (2021) Background Peak Hour Traffic ................................................ 13 8. Site Generated Peak Hour Traffic........................................................................... 15 9. Short Range (2021) Total Peak Hour Traffic........................................................... 16 10. Short Range (2021) Geometry ................................................................................ 17 APPENDICES A. Base Assumptions Packet B. Recent Peak Hour Traffic C. Current Peak Hour Operation/Level of Service Descriptions/Fort Collins LOS Standards D. Short Range (2021) Background Peak Hour Operation E. Short Range (2021) Total Peak Hour Operation F. Pedestrian/Bicycle Level of Service --// 'DELICH 1603 & 1605 North College TIS, April 2016 -71 r-ASSOCIATES Attachment 6 TABLE OF CONTENTS I. INTRODUCTION........................................................................................................1 II. EXISTING CONDITIONS..........................................................................................2 LandUse.........................................................................................................................2 Roads.............................................................................................................................. 2 ExistingTraffic................................................................................................................. 5 ExistingOperation...........................................................................................................5 Pedestrians Facilities...................................................................................................... 5 BicycleFacilities..............................................................................................................9 TransitFacilities.............................................................................................................. 9 III. PROPOSED DEVELOPMENT...............................................................................10 TripGeneration.............................................................................................................10 TripDistribution............................................................................................................. 10 Background Traffic Projections..................................................................................... 10 TripAssignment............................................................................................................ 14 SignalWarrants.............................................................................................................14 Geometry......................................................................................................................14 OperationAnalysis........................................................................................................ 14 Pedestrian Level of Service........................................................................................... 19 Bicycle Level of Service................................................................................................ 19 Transit Level of Service................................................................................................. 19 IV. CONCLUSIONS/RECOMMENDATIONS..............................................................21 LIST OF TABLES 1. Current Peak Hour Operation.................................................................................... 8 2. Trip Generation.......................................................................................................10 3. Short Range (2021) Background Peak Hour Operation..........................................18 4. Short Range (2021) Total Peak Hour Operation..................................................... 20 --// t—DELICH 1603 & 1605 North College TIS, April 2016 -7,1 rASSOCIATES Attachment 6 1603 & 1605 NORTH COLLEGE TRANSPORTATION IMPACT STUDY FORT COLLINS, COLORADO APRIL 2016 Prepared for: Peak to Peak Properties P.O. Box 102291 Denver, CO 80250 Prepared by DELICH ASSOCIATES 2272 Glen Haven Drive Loveland, CO 80538 Phone: 970-669-2061 FAX: 970-669-5034 Project #1605 e' Attachment 5 2. Right now that's a pretty tight turn. Will it work for the traffic volume expected for a drive -through? A. You're right, it's a tight turn. We will be widening this driveway to about 36 feet in width and softening the turning radii to provide an easier right turn off North College Avenue which is also State Highways 287 and 14 combined. With the truck traffic, we are aware of the nature of the traffic on the highway and turning right without the benefit of an exclusive right -turn deceleration lane. 3. Any problem with mixing traffic for multiple businesses with one driveway? A. Not really, but we will be adding striping to help direct drivers to either north (carwash and storage) or south (drive -through restaurant). 4. With the median, it looks like access will be controlled and limited to southbound traffic only. Is that the case? A. Yes, our driveway will be limited to right-in/right-out only turns. 5. Will there be access north into McDonald's and the fuel facility? A. Not at this time. An access easement is in place on the carwash property, which we own, that continues north to the south property line of McDonald's but they have to agree to make the connection. We have not yet contacted them about this possibility but plan on doing so as part of this process. 6. With no end -user, will you build a speculative restaurant? A. No. Our approach is to entitle the site per the City's standards through the normal course of the development review process. After entitlement, we may sell or lease to an end -user. If the end -user needs to make changes to the approved plans, then the City has a Minor Amendment process in place for that purpose but only as long as the proposed amendments do not change the character of the entitled plan. 7. Will there be enough stacking onsite without spilling over into the access driveway? A. Yes, we think there is sufficient stacking onsite. If the stack lane is too long, customers will either drive on past or pull in to park. 2 Attachment 5 NEIGHBORHOOD INFORMATION MEETING PROJECT: 1603 — 1605 North College Avenue — Drive -Through Restaurant LOCATION: Same DATE: March 24, 2016 APPLICANT: Chad Hirschfield CONSULTANTS: Russ Lee, VF Ripley Cody Snowden, Northern Engineering CITY PLANNER: Ted Shepard, Chief Planner The meeting began with a description of the proposed project. As proposed, the project consists of developing the vacant parcel at 1603 —1605 North College Avenue for a drive -through restaurant. The parcel is .69 acre and just south of the carwash. The name of the drive -through restaurant is not known at this time. The building would be approximately 2,500 square feet in size. The drive -through lane would be on the south side of the building. There would be roughly 34 parking spaces. An outdoor patio is included. Access from North College would be shared with the carwash to the north. The site zoned C-S, Service Commercial. On August 19, 2010, the Planning and Zoning Board approved a P.D.P. for Taco Johns drive -through restaurant on this site. Taco Johns then withdrew their request prior to completing final review. Unless otherwise noted, all responses are from the applicant or consulting team. Questions, Comments, Concerns 1. Will the access driveway be shared with the carwash? A. Yes, the existing driveway off North College Avenue that presently serves the carwash and storage facility will also serve the proposed drive -through restaurant. NORTH COLLEGE DRIVE THRU A TRACT OF LAND LOCATED IN THE NORTHEAST QUARTER OF SECTION 2, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH PRINCIPAL MERIDIAN, CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO ------ -�- -- -, ,._i I I LOTI cwv*w a�ecae,Lnswm vu,ltiEasl�v OFZP'6 q,1 LEGEND can�,(v p,gC4YBhv5PLD ITM1NEA iulUSfNLLf LiC ® NORTH A s Iw,u YZr mrl ry•A\ W Z J `a 00 U-j OV LLLL LL0 OW IF- �a U 9� W2 NORTH COLLEGE DRIVE THRU A TRACT OF LAND LOCATED IN THE NORTHEAST QUARTER OF SECTION 2, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH PRINCIPAL MERIDIAN, CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO [w YI vv. br,Y• Pre. Y Y sryrM •evle •(r Ylvy 1vY Imt' rr... P.s®v.irm•nrrmfrfnv.rr.Yx.svp.a+a.u. il...l,.+wml,ya awr.r r> w. r�..ry wem. nn.r r.n caw cwn.f �®. f:.rolr. rf w. P.rrxYr Y.rre. us., EnIrrcelYmm).T—, 4M Wfrx Wnr 0-ru1V.. tir Hla, Ci,w 6urq •,Yrrm,irof Cau,Y uwnuP bu:e w'�•vi' ww, vJ..p Ji eevl, inm mnrcrlvne c.....rr,,.e .r rk .',.,„a .a.,. a,.e �r,,.::,a. .,.w amr.. sw mPmr ax, . m •e ,x m.m 'r l" w Am{W 'e. 1101Y•W. W pW .•u{'m IOM % •. Jmr MJ P .Mffi sW wpm ' xmw i _ ..ra SIN 79'I '.n !1 nN .mrlr n. vlmE 0..urywn IWSW :E•.GP lui ,.r.w N X,rrnnrry,e nwn„Y.11 pw lsmoew rA. mor,als ,. rwrm.a w rx......m. i. r.l.� Iwlw•:n,� . w Ivn.«,�rriur�w..`i`.err�rl...n., :`•X �rr:,�m•• �m.,m w. w e,mvummmN wrNrwLxmn Plu Mnpu uYNllpmor¢uhYlw Nq Yelx6 Y f r r r,e rr arw rr. -r"4 r rlr w rem r �mww-. w .a evp.ae m'awrco-v«�m e.w, rTbYOyrr Yrrrl�rww Tb. Ygq•in. ,r rrlN,yY rr.Y �w rY.rYY:rL.PeY,.e. rru Irr. rYl •••. m rr•••• a w•�r..., wr...:� wr.rrr+..rr—rr�. r,r.r �w.r 4.« �.: -,. _.uM:a�.:+. r..rr.arraarr Yrrrr aes w rrwrr r r,ly YYr re a°Nm�. �n wrm n:,�". "+.r"�W`rr�eww�r :�`�fr�i. ww.�wwrfrr rY.r•N�..w w,m9r.. w: q .rcmma .! mr. mrw r aY r r..P r iw r rr� rr a�a . r.aYr Y Y .m r.m.e. rw. rwmerY.rf wYr e.ww wrewa•Y tee.. w'a.rr.r.aprc..l.....,:-o,.,..wr.•.w.....l..r r,®..rrnb w...,ll..rrl.re�Y. eemrw m«rl.w,,,u.l.rr ewuYl,w,.aw.amw:Iwrfi e•e. r.•Y.W Wewlr.rw rrw• w w...rmmr a.�wrY wrw«vl .., re. r..orYrwwr.rcJlrrr•Yrwxr ..rwr, vo...r.wwr... w.eY.r rb.n,w..,w.Yrrm mmeu-n ranMr a.area r..f.r. w:.l.,ne„ Irr r.rw a. a.:re rn, amaYn. W w••a. rtw.em oMm. r Iwr Eb or mr YnyuM•Y.r. ar MerPM.eIUMXA Yf u,CWf. m..rWv.uewu.r:rrwur.l.ie irrrrr.mnu amm sYCIN.w^e. e...rv. a T. awn Tn:E0i N10MCO 1 F Cq.T'ryQ Wp.®, 1 lYwlr:Y.swWPel•MFYPrr_4r ID�N wlemeYrar.rewr n—�r+.waPlra fr os rrf ..rras.wran. r.P:irw WlrarrrrrwrrrrrWrsbmxfrrr r,nvY• if fA•r. Y Y r 11r r+�r,r, Y Y Ywwr Y Y wrYf Y rwfY er r o.ww. rYrrrrr rr+rw.nr^rYrY�i..rrquwarr�.r>LY..f u iyr.rrf. weP�YrYYrY,r CrP rPYr ..wrrrY yrwrr +IY r..i. rr r r.,Yv. P.Y., rlYf..r Yr a r,s +f •wr. r r+•. YY•. P4•++.Y r rrlwYrrYrrwY.aw�w,w,w+.rw.wrrlr.rr..+.+n.r.r. h o.. w rr r.r.,ew.. � r ea �.rl.r r e •rw YY...awrr. wr.+s mf.I�Yrwl�w Pr•r,rrr,rraa'IYOPr Yiwrrrr W�PYYswlr.Ww.i .y. u r,.r.,r ry ar Ymymr•rr m Ww•wl'rlwP wrwrrar Yawrw4 are n�.iYumr.wrl.�.uriwlrtl.4Y ..Yi,JY.fiY1w.M4 •.�YrY. rirW �rlWSOJ Y�nwf rwm....,P.rreYrwllmrrmnrYwrrwarrbrra.. r Ywfirs rY rx•lrrerhr aYemY,W wfYr ra..e am Xeen Ym a mYraf rr. r.rrn f:Peal �r w r frw wPra rer. r.r. b r cb a: �M iTmr...r,.. r„ I...«wwe ewaw rwr rPrmarYrrrrrerr.wrrYr f�,.emm..r,.., r.r.,,rmr „r nr, nw rwrwrrr .ieY�W,Y�e�IrY.��•Yl�ll.•�4Ywex.•frl.wia® evelwmWrOnPrYYrY `.r_U• `rv4 ewb �rer� w�v.ePev�•tllew �y.y..+vrr.r r wr Y r rrm r e_ r. r.� wre.airP, r r.fr r.rr ✓ s r,rl ifY ar rr YMrY,pvy �M1Y.wrI,�Yn YeMY� I••rf�lwesr� LM1.srlr.bYPAYIYYr wP� m.ma r r wraf rv_wr..I,rwYu.yP.,w.w..,.yr rrrr r �ranYgWel r oPrrbemef•ro..errmwrrrrn.r,rrr, �frrr PeXibwwrfwrr r4 rw eur rrr ✓. Y wl wwlY r 4 lY elf rwwl i L riY l.0 tlr w Yr r rJ boYh.rs rra rY•+nr MoPr w of 4.4P Yswr er r wa rr IrYW lrr rYrr•I eY,.w r+s®r«.rYrr.rrurrw'rrrYPIW rl•rbm..�. bewYfrY. nr PXMNtlr, ILMn.w,lY. YWlrlw hrwir wrr ewr yoY f•r Sl11CM1Ma bm01.1 aAn,. r M1 W Ca .mo mr Y. vrrwa^rrrra.,.a haYro- r. mlmmmxwwr.. rn •r.sf pw.,, vlrr r,r, ,Yv MYY• 1 feY.i,, Ir ('•[6YY a •v, r r,ai M Y rLY vl PSM N l.r Csq. mwe rYh r•..rrs fo«Y q v by rwY. Mm. w u lame u pml q Laa...,CX,xlrne W,mfllefuY 9tAVm➢urteID�4 411i, C Trfr • Gw• a•yr•f NwIr11J Mn.l+f e!r w r f W YY W Y Pll w tq.tl M. •me, �•.rw,mr�+w•w.iY�ww..elw.rv... rf.,..•Y.arrrYb.PpYY .�e•Testmmer.i YYri.Mer rw1Pe, wwtlwrNlf rr:c..�+r aerw rfw... OFZP' 6 4.1 orva� wwPPuourr I.NIOKME MCNITECT tiwY•rm uc WrYN.f moY, wl sl'rY r•NaNeY�w e.e..mp..w Im w.Rv10 wa�r�w Y1 wwvevow rr.rmw�wa.�r C rNmr w A+r4r . i, J� V GNRV MYP noNnf ,. brafa.r�rranra.: rrrc rr_rrrw.u_ brrwrr�frd,rrr YYffwr Yws•f YOry YPe:fJIV GwYr OYv rC�n C•r W � r NrOY.f Y,r f416k 1. ae.rraw.YYerrrfrrvn.r,N.sfYrxrx.rrrrx.,wra.uamru• Wrrvr.r...r.r lY YYr..wYlr+ff Yr.a.fvYrawl x.rasw.r w.e�,rfrs. ROfNNf41.PTrb rrTlf•U�(u�l.irlrwrll>Ylf . irYr.rewwrlw.,r.ruwi.rlYll.wrY.Yr.r�.�,YPwnv� .Yrr,irw.orbl,.v lila.ls,naranw f. rmYre.YflL1,n.4.Ywa�Yw FA WO Zr J` 00 U � 0 OU LL 0 LL OW Y r f- UU m2� q 9 vwuPe* row. Ns NECNNrxrx 909EEN PER EGRr COLLM Lu.G 11� p� �q •/M.00ITbNt MPURI£W.NCE9 rtlGLV.T:U Wfin lE •MVO®UBE 9NLL1 lE NTiOVFNh1V 50EENE0 i0i EORi COttl W {AW U9E f.00E ^SOUTHWESTCORNER nRORTHNIESTCORRgI ietrne. 4 EASTELEVATION(COLLEGE AVE) OTT"ELEVA710N L'l s..� OTT" 2 VIEW ELEVATION /1SOUTH ELEVATION YVAnR..+r _ O F rr uocr rlaruetoeow�eE oerAR. NORTH COLLEGE DRIVE THROUGH �rrFF�r.y. iruFFntiVY POP 94BM1ITµ RYErt.4 ARCHITECTURAL ELEVATIONS 60F6 — — _..............._.._.._.._ cl on TREE MITIGATION LEGEND NORTH COLLEGE O L GE DRIVE • n.e 1 !a•WW aw ! a•am! 1�1. al�� asap • �'� 1{ IN• i �I.all a• M1 Y 11 YiB • SIN YI If IM• IS II M6Y • IIObFMN AAg1 M Mll li Iy • u�eNoonvFam r rNF u • aYpXp110 Mewrm mawr • aaaNaa ! ..w. a IamFwr ar•rui a• roan a ram•awr PROJECT DEVELOPMENT PLAN •WMv{ii01•IN1M0� rw'r'L�..o�.i—�� TME MMGATIoN suMMARY PROVIDED TREE MMGATION illMixf l W 0 F W i 1!i M A{IA401apaa1011{ 1.1. fluL�•Ye10[lld. V WPalY110IfaAN011YFNW1. LL OgNOI1NlI0 V LWIO1 W�Ya•1••lYImMYM. IS •LaO�lla� F�tlON�Y�®YYYYNPI WINMHrt. L MWMIOYOMVNM®MM•FNL16�1LLMRIVBENa Ma2W 1ayMnMMYNUOFR•ndw/inliNF �wvFnmxomnu�•rrm 11®f W1MCNlfM •INIftlYYtt R9aNOlItM®QIL WEY/Il M1m aYO1 � N m•d •v M .V N•fF �OaY 61YlF•1!i R•i•d. L 1F® �•E wlwEliiu •FYIO�FM�9MOE FFM1OFMTN�BPMFOM W LV OL F.1111• IMT.11E MLL • VIFFu xN.•IU• M� AI�MYFF•RD TOI N WigRMMYI•�4 laa! MIIrIMYFI WIIFMnFY •0Ia6MN�Vi WI11F•�M.YO MYa Off• W M •Fum Fa TREE MITIGATION PLAN ss 5OF6 GENERAL LANDSCAPE NOTES ..aw %w.wwm.ww.e. m.w,w..Ya,YYsw.wem. Y..®NwIO.wM.wYO.F�,w,.Wuld.,p e,y Y.oYwEm.1Xw M.w[�w„Y.W,. v.,ro� ivi. TREE PROTECTION NOTES WATER USE TABLE ...vw w.Nn a� xnaYn .�.Y�. . w..Y.i ww m �� w �w M rm W _ . .Y mrK �i.. wwn ...wMs,wsuwwwww..rwn� �mY.ew.wraY,.o�,..,wwYrY..w. sY.ww..,wsWW �..uvwY wu.l..>`A,OwwuO.wswm��e us.,c�m nerv+e�rma,vnYsu.Y��aw,ea srsawwwr.�r Yew .u�.wrw.sNss +�r�n N . N . N . NY tl OK1,. M &CONIFER TREE PLANTING DETAL -WOOD POSTS . �\ TREE PLANTING DETAR- WOOD POSTS r1 SHRUB PLANTING DETAIL '^"^�"""""^�` Y.. Y. m NORTH COLLEGE DRIVE THROUGH PROJECT DEVELOPMENT PLAN LANDSCAPE NOTES AND DETAILS 40F6 PLANT SCHEDULE NORTH COLLEGE DRIVE THROUGH w®n..mo.no. m a mn mmxnurmroxxn®.v ... r un®rarmarv, noe x aw�m.ouoor.�®.m ,wiwnm.ar� u. r u•.mw.,noam PROJECT DEVELOPMENT PLAN +w ...e.uo�e���o.r�ue,vn.aoe• u a.re.wwuuar'mne�r�mnamirn�e. .0 ..s a�wnvmurim �.. �nr .rc�mru rg^ y� � .a x w®rwazwiora+-.wuwwu�wmr'wnrwurawn�.ry � ffi ... v uv�r.opmnu�anonnmr�rwarminm�mw��aws .tau. a.. a amw.�rimsauwncwr�rac�c.wvww000 manr�.urums.cnarmw.+�w�rui `aiusrimwnm �' .ar e� a r .�aa.�vn uwaw.wM.'.vrrxrwon+Na 'a atia.�z•mc rwomr�swomuw nwr+..r�..+r... wcrw.w rwaFncr�wrwam .mw,runrenro..a,a.mrww�rmenu. .rr....r.. w .ww�n,.noocw. m eur�u.n ao�wrw��uvc soil _ ...•�:.�•�� rw.ee. �.wr�a. �+eaa+x�c. M t� .Ap.•Ertq sy/rp1�I�Ypiµ1.IC .pM rnnwrt __ MATERIAL LEGEND LEGEND .a •eecnc,o...e,e. .rasLL � o`a •.un..veaEnar.xaur TREE LEGEND f�41R •.m.iu..n imnr •YIIIMM1 Et1 V 1 ER.ti MYiY • Wr.nle.rr.re• . rBTp{y1Ury •4®YisBIR VIWF 1MOtd! TREE SPECIES DIVERSITY FENCE DETAIL i.YRp u u q.�. �• "—` LANDSCAPE PLAN 3OF6 I I I i I I I I I I I I 1 I I I I I I I I I I I I I I I 1 ' I I I I I I I uarr+ M xwv aa�.•..� •'t'� emc rA 3 RIP nn I`Y GOI[rt� ]SW 9F F19T F00 � G! eFinn ammlz� _ ) IF-Fw�1iw m .. •.I wry.ime� . nrelarF+rm .aq yrt ----- ------------- LEGEND SITE PLAN NOTES NORTH COLLEGE DRIVE THROUGH �` aw. •Wrrxry rv�v maulon a.. PROJECT DEVELOPMENT PLAN z IW.wir w®a..wr®m.n�w •Ran iliM. Wse Wes uv..oe _ .�a� ., vw���>nYrrWn •P1MIrl U1 Y1YIr I/rWAR w+�w��oa wmns n.w -n@MIL IIM. eN ,oyNN� ua�savua ®W .oroefK Y�L'IK URm .wemwram AaIY ONw Nury ®�wW.�m'c ri.¢� w .vwFrl.!'R11lt.VL MPr varwwWa.w n�m uuaWrn . YM1MY �VIV1r �__n W.a.f.rFnriOONNOens .IRV6.W610 fLLnl a.lr. mr.iwvsnae au wmnmwevwn.e W�waw�r.nlea non saislma Nv�eu' � ane wnnwv rr �W.Nw..� a�.w. �•� G���•vi ,r,G„ pylr 'rW orgsA YG � uNwlxWIeCIF SITE PLAN sE.. oluxma Floe 2OF6 NORTH COLLEGE DRIVE THROUGH PROJECT DEVELOPMENT PLAN OWNER'S CERTIFICATE M LM6Kad OOBI.IOE W F6R11.TMTEEILIKMUKELL4F11AOFMM,L COIPIIW Ma�IE[TOa IiTPFIxwLEOaRaP. TMTNIl4dfM pNRRpgNIEI iEK wvp waa_.ry K rybaYaOx t»aYE aMK W MM.VaOMON YN PLANNING CERTIFICATE /.E.IEpMOIMO[Giq CI NYWMIT OMRMID KKaIwCCOKMCUw Mmr>.dF: (�:�. W WMCC wireL_w.aE�Fa_. nwr4r. LEGAL DESCRIPTION MM10 MKIIEKVi0.'MMV WCIYLMaaaOKM WfILf6 WJxwFKKTWMR0. VJExOVff@KRK6nW x0. ib®F.MOEwifpiOME11EEitiOEaQ MUG6n.YUMLYf uKLi aaiLC!xa MEaLKxba MPNiaayMiTIICfO�YaIOY®al�ld �4 ]O�LmNx a'lEINFBF•Mi RF', n0R941W M.TKLKu01a ME�l,f1llRMa�lM�afua Cwnr w4 w'O EVF E6aaaKM. aYPxlaT W i �u as[[�, �x[x:E LFpxptiEnF xw u�x or uO+fcEn� WNEWFY.pYMFFMI W[EaaFLFIiO FxE spn�p BEGunxp. COxiuxL W,>ll WwRF EFE� w o W xCNL4pllwlb. VICINITY MAP LAND USE CHART ilaOlEif x. R� RIaYa®IOFIIU®.lai � SHEETINDEX aRILK n�FnamaaE I � .FIIWRIYYMEOa NORTH COLLEGE DRIVE THROUGH PROJECT DEVELOPMENT PLAN • NME.YY�nNw•un. vl YMxxMn�n• OEWMF OTM W NCIMY6 Y�1 . EILiM W M�4�aaa COVER �K K�a�a1�R pMMI16111I1BE% 1 OF 6 Attachment 2 land planning landscape architecture urban design entitlement North College Drive Thru Project Development Plans Planning Objectives: North College Drive Thru is a commercial development that sits on a 0.693 acre site located on the west side of North College Avenue, between Willox Lane and Cherry Street. The site is zoned Service Commercial (CS). The proposed development consists of a new 2,500 square foot building with a drive thru lane and parking. The goal of the project is to entitle and design a lot that will serve a user that requires a drive thru. A specific tenant is unknown at this time. The development will share an access off College Avenue with the adjacent car wash to the north. The shared access is proposed to have a softened southbound right turn movement by increasing the turn radius and enlarging the entrance. This will keep cars on southbound College from slowing down to speeds that could cause stacking concerns before making the turn. Currently, the site is comprised of two vacant lots that create a gap in the revitalized commercial district that is North College. This development looks to fill that gap by providing a property for a commercial use that requires a drive thru, since this zone district is one of the few that allow such use. The site will utilize permeable pavers and a raingarden as a drainage solutions, as well as enhance the appearance of the North College street improvements. A native landscape with upsized trees will help to screen the development from its neighbors and screen the car headlights generated by the proposed drive thru lane. By combining forward thinking site improvements with updated contemporary architecture and a native landscape, this development is designed to expand the potential of a burgeoning commercial district. Thinking outside of the box for over two decades 419 Canyon Ave. Suite 200 c Fort Collins, CO 80521 z tel. 970.224.5828 : fax 970.224.1662 www.ripleydesigninc.com ............................. SHARED ACCESS WITH CARWASH TO NORTH PAVERS - s ............... EXISITNG STREETTREES r~ PATIO A ` TURF r C� RIVETHRU ........ PLANTING BED ..... am w \'. Z I land planning #' landuape whnectum urban dmign entitlement 1 inch = 400 feet 1603/1605 N College Ave w� e The City of Fort Collins will make reasonable accommodations for access to City services, programs, and activities and will make special communication arrangementsforpersons with disabilities. Auxiliary aids and services are available forpersons with disabilities. V/TDD: Dial 711 for Relay Colorado. Fsta es una notifrcaa'6n sabre la reunion de su vecindario o sobre una audiencia ptiblica sabre el desarrollo o proyecto en la propiedad cerca de donde usted es el dueno de propiedad. Si usted desea que esta notificaci6n sea traducida al espanol sin costo alguno, favor enviar un correo electr6nico en espanol a la siguiente direcci6nelectr6nica• translatena m2v.com. Agenda item 2 • In the short range (2021) future, given development of the 1603 and 1605 North College site and an increase in background traffic, the North College / Willox and North College / Site Access intersections will meet the City of Fort Collins Motor Vehicle LOS Standard, the warranted auxiliary (right -turn) lane. The increase in delay at the North College / Site Access intersection without the warranted auxiliary right -turn lane will not be significant. • The site project is served by Transfort Route Eight. 4. Neighborhood Meeting: A neighborhood meeting was held on March 24, 2016. A summary of this meeting is attached. Those attending the meeting expressed no opposition to the project. 5. Findings of Fact/Conclusion: In evaluating the request for the North College Drive -Through P.D.P, Staff makes the following findings of fact: A. The proposed land use, drive-in restaurant, is a permitted land use in the Service Commercial zone, subject to Planning and Zoning Board review. B. The P.D.P. complies with the applicable General Development Standards of Article Three and the C-S zone district standards of Article Four. RECOMMENDATION: Staff recommends that the Planning and Zoning Board make a motion to approve the North College Drive -Through P.D.P., #160014, based on the Findings of Fact on page six of the staff report. ATTACHMENTS 1. Rendered Site Plan (PDF) 2. Planning Objectives (PDF) 3. Site, Landscape, Architectural Elevations (PDF) 4. Plat (PDF) 5. Neighborhood Meeting Summary (DOCX) 6. Transportation Impact Study (PDF) Item # 2 Page 6 Agenda Item 2 Section 3.5. 1 (B) (C) (E) (F) - Building Project and Compatibility This standard is designed to ensure compatibility of new buildings with the surrounding context. In this case, there are no existing buildings in the vicinity that feature distinctive architecture or are representative of any particular architectural style. The building, as designed, represents a commercialized yet contemporary style that uses traditional materials (brick, synthetic stucco, lap siding) that will both blend in and upgrade the immediate vicinity. J. Section 3.5.3(B)(1) - Relationship of Buildings to Streets, Walkways and Parking - Orientation to a Connecting Walkway As mentioned, there are two direct connecting walkways out to public sidewalk along North College Avenue without crossing a driveway. One leads to the main entry and one leads to an employee entry/exit. K. Section 3.5.3(B)(2)(a) - Relationship of Buildings to Streets, Walkways and Parking - Build -to Lines North College Avenue is classified as a four -lane arterial street. The building is brought up to 19 feet of the right-of-way, thus not exceeding the required 25 foot build -to line. L. Section 3.5.3(D)(1 - 6) - Character and Image The 2,500 square foot building features four-sided architecture. The base is a dark brick. The field is mostly synthetic stucco but accented by fields of brick and lap siding. The top is a synthetic stucco cornice with two, two-inch in -steps. The north facing entry is highlighted by a horizontal overhang. The south elevation includes the dispensing window which is also accented by an overhang. The flat roof is broken up by vertical features that exceed the roofline. (Architects now refer to these as "blades".) In general, the building is articulated by a variety of wall planes and windows to mitigate the box -like character that is typical of drive -through restaurant industry. M. Section 3.6.4 - Transportation Level of Service Requirements According to the Transportation Impact Study: • The development of North College Drive -Through P.D.P. is feasible from a traffic engineering standpoint. • The joint access driveway intersection with North College Avenue is now restricted to right- in/right-out only turns due to the recent construction of a median in North College Avenue. • Current operation at the North College/Willox and North College/Driveway intersections is acceptable with existing control, geometry and signal timing. • Acceptable level of service is achieved for bicycle, and transit modes based upon the measures in the multi -modal transportation guidelines. Pedestrian level of service is achieved for all areas except the residential neighborhood to the west of the site as this mobile home park was constructed without sidewalks. Item # 2 Page 5 Agenda Item 2 B. Section 3.2. 1 (E) (4) (a) -Parking Lot Perimeter Landscaping To the west and south, the vehicle use area will be effectively screened with a new six-foot solid wood fence. The height of the fence will be extended by two feet by an open weave design that adds a measure of opacity and thus contributes to parking lot screening. The existing fence will be demolished. The parking lot perimeter is landscaped along the shared access driveway along the north property line with three shade trees. There is a mix of shade and evergreen trees along the west property line. To the south is a stormwater detention pond is upgraded with a mix of ornamental trees and a variety of deciduous and evergreen shrubs. C. Section 3.2.1(E) (5) - Parking Lot Interior Landscaping The parking lot has 35 parking spaces which require a minimum of 6% interior landscaping in the form of islands. The parking lot features three islands and interior landscaping and, therefore, exceeds the required minimum. D. Section 3.2.1(F) - Tree Protection and Mitigation Several Siberian Elms will be removed requiring no mitigation due to being an invasive species. One deciduous shade tree will be removed requiring mitigation. As a result, six new shade trees will be up -sized from 2.5 to 3.0 inches in caliper as per the requirements of the City Forester. E. Section 3.2.1(E)(6) - Screening The headlight glare from the drive -through lane will be screened with a hedge of seven evergreen shrubs that are placed on a low earthen berm. Trash and recycling containers will be attached to the west side of the building and not visible from North College Avenue. F. Section 3.2.2(t3) - Access Circulation and Parking and Section 3.2.2(C)(5) - Walkways Sole access is gained by the shared driveway along the north property line. There are two direct connecting walkways that link the building to the new public sidewalk along North College Avenue without an intervening drive aisle. Internally, a private walk will connect to the mobile home park at the southwest corner of the site. G. Section 3.2.4 - Site Lighting Parking lot lighting and building -mounted exterior lighting will feature down -directional and sharp cut-off fixtures. Pole lights located along the western and southern edges will feature house -side shields to minimize light intrusion along the shared property line with the mobile home park- H. Section 3.2.5 - Trash and Recycling Enclosures As mentioned, the trash and recycling enclosure will be attached to the west side of the building. This allows the enclosure to read as if it were an integral part of the building versus a stand- alone enclosure in a remote part of the parking lot. In addition, the enclosure is designed to accommodate containers for used cooking oil. Item # 2 Page 4 Agenda Item 2 Zoning History B-G, General Business, from 1965 to 1976; H-B, Highway Business from 1976 to 1997; C-N, Commercial North College, from 1997 to 2009; C-S, Service Commercial, from 2009 to present. All current and previous zone districts permitted drive -through restaurants. Between 2000 and 2005, building permit records indicate that there were repeated violations with regard to dangerous and unsafe conditions of the buildings at 1603 and 1605 North College Avenue. The notification letters to the owner indicate that there was a history of vagrants illegally occupying the structures and frequent instances of vandalism and fire. Finally, in 2005, the buildings were demolished. In June of 2010, Taco John's International Inc. submitted the North College Taco John's P.D.P. (13- 10/A) for a drive -through restaurant. The P.D.P. was approved on August 19, 2010. On September 1, 2010, the Final Plan was submitted. On December 1, 2010, the applicants withdrew the Final Plan. The City recently completed the North College Capital Improvement Project which included the frontage along the subject parcel. The overall project budget was roughly $12 million for design, right-of-way acquisition, and construction. Funding consisted of the following sources: • Responsible Acceleration of Maintenance and Partnerships (RAMP); • Transportation Enhancement (TE); • Surface Transportation Program (STP) • Keep Fort Collins Great; • City Capital Projects Fund Reserves; • City General Fund Reserves, • City savings from the Vine to Conifer Capital Project. 2. Service Commercial Zone District: A. Permitted Uses Drive-in restaurants are a permitted use in the Service Commercial zone, subject to Planning and Zoning Board Review. B. Land Use Standard The building is one story, thus below the maximum height of three stories. 3. Compliance with Applicable General Development Standards: A. Section 3.2.1(C)(D) - Landscaping and Tree Protection The P.D.P. provides full tree stocking and foundation shrubs around the building where there are no conflicts with paved areas. Street trees were planted along North College Avenue in conjunction with the recently completed City of Fort Collins capital improvement project. Item # 2 Page 3 -1 COMMENTS: 1. Background: Agenda Item 2 1 inch = 400 feet North College Drive -Through P.D.P. ? The surrounding zoning and land uses are as follows N: C-S; Carwash and Self -Storage, Drive -through Restaurant and Fuel Facility S: C-S; Mobile Home Park E: C-S; Shopping Center [Drive -through and Fast Food Restaurants, Bank, Retail, Fuel Facility, Vehicle Minor Repair, Retail Store with Vehicle Servicing and vacant space (former Albertson's)] W: C-S: Mobile Home Park Item # 2 Page 2 Agenda Item 2 PROJECT NAME NORTH COLLEGE DRIVE -THROUGH PDP#160014 STAFF Ted Shepard, Chief Planner PROJECT INFORMATION PROJECT DESCRIPTION: This is a request to re -develop the now -vacant parcel at 1603 —1605 North College Avenue for a drive -through restaurant. The parcel is .69 acre and on the west side of North College Avenue and immediately south of the existing carwash. The building would be approximately 2,500 square feet in size. The drive -through lane would be on the south side of the building. There would be 35 parking spaces. An outdoor patio is included. Access from North College would be shared with the carwash to the north. The site zoned C-S, Service Commercial. On August 19, 2010, the Planning and Zoning Board approved a P.D.P. for Taco John's drive - through restaurant on this site. Taco John's then withdrew their request prior to completing final review. APPLICANT/OWNER: Mr. Chad Hirschfield and Mr. Jon Sites c/o Ripley Design, Inc. 419 Canyon Avenue, Suite 200 Fort Collins, CO 80521 RECOMMENDATION: Approval EXECUTIVE SUMMARY The proposed land use is permitted in the Service Commercial zone district. The P.D.P. satisfies the applicable criteria of the General Development Standards of Article Three and the C-S district standards of Article Four. Item # 2 Page 1