HomeMy WebLinkAboutUNION PLACE - MAJOR AMENDMENT - MJA110003 - CORRESPONDENCE - (7)City, of
i
Department: Zoning
Community Devek. .ant and Neighborhood Services
281 North College Avenue
PO Box 580
Fort Collins, CO 80522
970.221.6760 970.224.6134 - fax fcgov.com
Contact: Peter Barnes, 970-416-2355, pbarnes(cDfcgov.com
Topic: Site Plan
Number: 1 Issue Originated: 08/25/2011
08/25/2011: It appears that the only trash dumpster location is at the entrance off Willox.
Are those two adequate? Also, the location would impede traffic if people stop in the
driveway to toss trash, whether entering or leaving the development. More'thought should
be given to location and/or providing a "loading zone" for cars to be able to park by the
enclosure without blocking the driveway. '
Number: 2 Issue Originated: 08/25/2011
08/25/2011: Two signs shown along Willox. Only one sign is allowed.
Number: 3 Issue Originated: 08/25/2011
08/25/2011: The building envelope depth is shown but not the width. Also, it looks like the
depth dimension includes the parking and the setback. The envelope dimension should
only be for the building.
Number: 4
Issue Originated: 08/25/2011
08/25/2011: The 8.5 x 18 parking stall dimensions are allowed only if there are no
compact spaces, per Section 3.2.2(L)(3) of the LUC. Either the compact spaces will have
to be changed to 8.5 x 18, or all of the 8.5 x 18 will have to be changed to 9 x 19.
Be sure and return all of your redlined plans when you re -submit.
If you have any questions regarding these issues or any other issues related to this project, please
feel free to contact me at 970-221-6206.
Sincerely,
Emma McArdle
City Planner
9
Staff Review Letter Generated: 9/6/2011 at 2:49 pm
City, of
Fort Collins
Department: Technical Services
Community Devel., ,ent and Neighborhood Services
281 North College Avenue
PO Box 580
Fort Collins, CO 80522
970.221.6760 970.224.6134-fax fcgov,com
Contact: Jeff County, 970-221-6588, icountvCa�fc4ov.com
Topic: Plat
Number: 1 Issue Originated: 08/31/2011
08/31/2011: The Subdivision Plat boundaries close.
Number: 2 Issue Originated: 08/31/2011
08/31/2011: Please change the Subdivision Plat name to "Union Place Subdivision First
Replat".
Number: 3 Issue Originated: 08/31/2011
08/31/2011: Please remove the"legal description per title commitment'.
Number: 4 Issue Originated: 08/31/2011
08/31/2011: Please add a lineal measurement statement per Statute 38-51-106(I).
Number: 5
08/31/2011: Please add to the sub -title, being a replat of ....
Number: 6
08/31/2011: There is one text over text issue on sheet 3.
Topic: Site Plan
Number: 7
08/31/2011: There are line over text issues.
Department: Traffic Operation
Contact: Ward Stanford, 970-221-6820, wstanford(a)fcgov.com
Topic: General
Number: 1
09/02/2011: No Issues with proposed changes to the development.
Department: Water -Wastewater Engineering
Contact: Roger Buffington, 970-221-6854, rbuffington(ilfcgov.com
Topic: Construction Drawings
Issue Originated: 08/31/2011
Issue Originated: 08/31/2011
Issue Originated: 08/31/2011
Issue Originated: 09/02/2011
Number: 1 Issue Originated: 08/30/2011
08/30/2011: Revise Note 8 pertaining to the abandonment of water services to require the
contractor to remove the curb stop and service line.
Number: 2 Issue Originated: 08/30/2011
08/30/2011: Are any irrigation taps planned?
Number: 3 Issue Originated: 08/30/2011
08/30/2011: See redlined utility plans for other comments.
Department: Zoning
8
Staff Review Letter Generated: 9/6/2011 at 2:49 pm
City of
F6rt Collins
Department: PFA
Community Devel,. ..ant and Neighborhood Services
281 North College Avenue
PO Box 580
Fort Collins, CO 80522
970.221.6760 970.224.6134-fax fcgov.com
Contact: Carie Dann, 970-219-5337, CDANN(rDpoudre-fire.om
Topic: General
Number: 1 Issue Originated: 08/30/2011
08/30/2011: As previously stated, minimum widths for Emergency Access Easements
are travel width for emergency apparatus, meaning a minimum EAE width of 20 feet. The
private drives shown that are 12 feet and 17 feet in width are not allowed. Also, as
previously stated, minimum turning radii is 25 feet inside, 50 feet outside. Necking down
the EAEs also does not meet the turning requirement.
Department: Stormwater Engineering
Contact: Wes Lamarque, 970-416-2418, wlamargue(a@fcgov.com
Topic: General
Number: 1 Issue Originated: 09/06/2011
09/06/2011: Please provide the lot corner elevations and the building F.F. elevations as a
minimum to the grading plan. At building permit, a more detailed grading plan can be
submitted with the detailed building footprints. The notes on the plans are adequate to
address this issue. The development agreement will also be modified to reflect this as
well.
Department: Technical Services
Contact: Jeff County, 970-221-6588, icountv(rDfcgov.com
Topic: Building Elevations
Number: 9
08/31/2011: No comments.
Topic: Construction Drawings
Issue Originated: 08/31/2011
Number: 11 Issue Originated: 08/31/2011
08/31/2011: Please change the Utility Plans title to "Union Place Subdivision First Replat".
Number: 12 - Issue Originated: 08/31/2011
08/31/2011: The description of the Northeast corner of Section 2-7-69 on the cover sheet
does not match the Subdivision Plat (replat).
Topic: Landscape Plans
Number: 8
08/31/2011: There are line over text issues.
Topic: Lighting Plan
Number: 10
08/31/2011: No comments.
Topic: Plat
V4
Issue Originated: 08/31/2011
Issue Originated: 08/31/2011
Staff Review Letter Generated: 9/6/2011 at 2:49 pm
City of
Fort Collins
Department: Environmental Planning
Contact: Lindsay Ex, 970-224-6143, lex(cDfcgov.com
Topic: General
Number: 1
08/31/2011: No comments.
Department: Internal Services
Community Devel,_,ient and Neighborhood Services
281 North College Avenue
PO Box 580
Fort Collins, CO 80522
970.221.6750 970.224.6134 - fax fcgov.com
Contact: Emma McArdle, 970-221-6206, emcardle[cDfcgov.com
Topic: Plat
Issue Originated: 08/31/2011
Number: 1 Issue Originated: 09/02/2011
09/02/2011: Tracts "A", "F" and "P" were purchased by the City in January of 2010. The
notes on the subdivision says these are owned and maintained by Union Place. -
Comment made by Helen Matson, Real Estate Services, City of Fort Collins
Department: Light And Power
Contact: Justin Fields, 970-224-6150, ifields(cafcgov.com
Topic: General
Number: 1 Issue Originated: 08129/2011
08/29/2011:
The existing single phase electric system will need to be upgraded to three phase to
accommodate the proposed changes. Please contact Justin Fields (970-224-6150) to
review this upgrade. In particular we will need to coordinate transformer and meter
locations. In addition, we will need to have a completed C-1 form for each building. The
C-1 form is available online at
hftp://www.fcgov.com/utilities/img/site_specific/uploads/c-1 _form.pdf.
Department: Outside Agencies
Contact: Emma McArdle, 970-221-6206, emcard le0fcgov.com
Topic: General
Number: 1 Issue Originated: 09/06/2011
09/06/2011: The City of Greeley routing was sent to Greeley's Planning Department rather
than the Water and Sewer Division. I have called Sylvia the person we dealt with for the
last project to see if they have any issues with the newly proposed community garden in
the easement location.
Department: PFA
Contact: Carie Dann, 970-219-5337, CDANN(cDpoudre-fire.org
Topic: General
6
Staff Review Letter Generated: 9/6/2011 at 2:49 pm
F,Ciity of
Collins
Department: Engineering Development Review
Community Dave,_,..aent and Neighborhood Services
281 North College Avenue
PO Box 580
Fort Collins. CO 80522
970.221.6750 970.224.6134 - fax fcgov.com
Contact: Andrew Carney, 970-221-6501, acarney(cDfcgov.com
Topic: General
Number: 2 Issue Originated: 09/02/2011
09/02/2011: As this new utility plan set is a stand alone set, it will need to include
everything and not reference the old Union Place set. Therefore, the complete details will
need to be included, along with all applicable sheets. See redline notes on cover sheet
and throughout the set.
Number: 3 Issue Originated: 09/02/2011
09/02/2011: Any items that are currently constructed need to be shown as existing
throughout the set. The existing items need to be in a clearly legible grey scale with no
crosshatches. Currently the grayscale is difficult to read due to crosshatching and will not
meet the City's scanning requirements. Any item that is in a solid dark line weight should
be a currently proposed improvement or a improvement that is proposed to be altered (ie
water services). Any item that is currently built will need to be shown as existing in a solid
grey line weight. See redlines.
Number: 4
Issue Originated: 09/02/2011
09/02/2011: Please dimension the existing ROW adjacent to the property on both Willox
Lane and Mason Street as well as any easements.
Number: 5
Issue Originated: 09/02/2011
09/02/2011: More off -site context and grading is needed. Please show at least what was
shown on the original utility plan with everything that is currently constructed shown as
existing.
Number: 6
Issue Originated: 09/02/2011
09/02/2011: Is there any phasing proposed? If so, please clearly show any phase lines.
Number: 7
Issue Originated: 09/02/2011
09/02/2011: Dimensions are needed on the utility sheet for ROW, Easements, Sidewalks,
Drive isles, Parking stalls, etc.
Number: 8
Issue Originated: 09/02/2011
09/02/2011: On sheet PP01, please do not show the paving and C&G on Mason and
Willox as proposed in a darker line weight, they are constructed and considered existing.
Number: 9
Issue Originated: 09/02/2011
Please add the following note to the new plat under the heading "Development Agreement
Notice". "The Union Place Subdivision Development Agreement (Reception #
20090074634) dated October 23rd, 2009, between the City and Union Place, LLC, shall
apply to the property shown on this replat. This agreement should be viewed for additional
stipulations or requirements that may encumber the property."
Number: 10
Issue Originated: 09/02/2011
09/02/2011: Please see the redlined plans for more complete notes. Only items required
prior to hearing were checked so additional comments may arise in later rounds of review.
Department: Environmental Planning
Contact: Lindsay Ex, 970-224-6143, lex(&fcgov.com
5
Staff Review Letter Generated: 9/6/2011 at 2:49 pm
City of
Fort Collins
Department: Current Planning
Community Devei. _ .ent and Neighborhood Services
281 North College Avenue
PO Box 580
Fort Collins, CO 80522
970.221.6750 970.224.6134-fax fcgov.com
Contact: Emma McArdle, 970-221-6206, emcardle(c fcgov.com
Topic: Site Plan
Number: 10 Issue Originated: 08/31/2011
08/31/2011: Section 3.2.2
- (C)(1)(a) Separation of vehicles and peds. Can we get a paving differentiation at the
service bays? Maybe keep as concrete or colored/stamped paving. (Also reiterated in
Section 3.2.2(C)(5)(b))
- (C)(3) Site amenities - I would like to see the plan get into details like benches, water
fountains, etc. to encourage walking around the neighborhood.
- (C)(4) Bike facilities - can we get some racks closer to the entryways?
- (c)(5) Walkway directness and continuity - Please add a sidewalk from the central
parking lot toward the park across the street.
- (C)(6) Direct on -site access for ped and bicycle destination, reiterates the need for a
few sidewalk links from parking lot to park.
- (D)(1) Ped and Vehicle separation - reiterates the need for differentiated walk for peds
in service area.
- (13)(3)(d) lighting for off street parking areas needs to prevent spillover into residential
use, not shown yet
- (E)(2) traffic control devices - please show stop signs on site plan.
- (E)(5) - Points of conflict - reiterates the need for differentiated sidewalk through
service area.
- (K)(1) - Mod of standard in process.
- (K)(6) Loading zones - service areas accommodate this for residential. Are any
needed for commercial buildings?
- (L) Parking Stall Dimensions - Previous Mod of Standard reduced spaces on street to
7' wide, new parking stalls meet standards for long term parking (8.5' x 18'. Drive aisles
meet standards of 20' for single loaded and 24' for double loaded (after code clarification).
Currently, not using 2' overhang in sidewalk, which would be a wash if you choose to use
it. You could consider angled tree grates, where the corners go into the parking stalls,
maybe could save you some space to provide tree grates?
a. Long-term spaces work for residential, but the spaces adjacent to commercial should
be standard width/length (Lot 3 Block 5).
- (M)(1) Landscape coverage - these calculations need redone to count drive aisles.
Keep in mind perimeter landscaping counts for this too, so I would expect that you'll meet
this with no problem, especially adding the tree grates.
Department: Engineering Development Review
Contact: Andrew Carney, 970-221-6501, acarnev(&fcgov.com
Topic: General
Number: 1
Issue Originated: 09/02/2011
09/02/2011: The title of the utility plans can not have the words "Major Amendment", please
remove. Also, the title of the set will need to be different than the first set, so "Union Place
Subdivision" can not be used. See Technical Services comments for more detail.
4
Staff Review Letter Generated: 9/6/2011 at 2:49 pm
City of
F6rt Collins
Department: Current Planning
Community Devei,. ,ent and Neighborhood Services
281 North College Avenue
PO Box 580
Fort Collins. CO 80522
970.221.6750 970.224.6134-fax fcgov.com
Contact: Emma McArdle, 970-221-6206, emcardlecDfcaov.com
Topic: Landscape Plans
Number: 9 Issue Originated: 08/31/2011
08/31/2011: Sect. 3.2.1
- (D)(1) minimum plantings - full tree stocking questionable on rear of building
- (D)(3) Min Diversity - table needs updated.
- (E)(1) Buffering between incompatible uses - With a parking lot adjacent to the south
property line, we need to provide a little more buffering to the south for neighboring
residents. I've suggested a few trees on the plan to help buffer car lights. I again would
like to see some tree grates in the sidewalk along the building to help break up the large
structure from the view from the south and to provide a better environment for the
residents.
- (E)(2) Foundation Plantings - not met on multi -family building in view of Mason. Tree in
grates and some dispersed foundation planting areas will accommodate this standard.
- (E)(4) parking lot perimeter landscaping:
a. need to add a few on the west property line (1 per 25' on property lines). Also, this
area does not meet screening requirements. Other parking lots have fencing meeting the
75% opacity for lights. This area is circled and probably needs a creative solution due to
utility locations.
b. need to add a few trees on the south/west side of the detention pond to help adjacent
residential screening.
- (E)(5) Parking lot interior - these calculations seem way off, my calculation of Lot 1
Block 1, was at about 11,200, your calc says 5,283. The drive aisle may be the difference,
this is part of the parking lot and is included in the area to calculate the 6%.
a. (E)(5)(b) 1 canopy shade tree per 150 sq. ft of internal landscaped area.
b. (E)(5)(c) this requires landscape islands to be 8' wide in the smallest dimension, this
is not met in a few areas.
c. (E)(5)(d) walkways and drive aisles shall have a canopy shade tree per 40' of linear
walkway. This can be addressed by the tree grates in the sidewalk along the buildings.
- (E)(6) screening of low interest areas. Where are service areas, utility boxes that are
visible from offsite area? Please show all these areas on plans. Let's try to screen them
as appropriate. Is garbage being collected in the service door areas?
- Alternative Compliance. You may want to consider an alternative compliance plan, this
doesn't mean you don't have to meet the standard's above, it does mean you have some
more creativity in how you meet them rather than meeting the exact quantitative standard.
Take a look at this section for criteria.
Topic: Lighting Plan
Number: 11
Issue Originated: 08/31/2011
08/31/2011: 3.2.4 Site Lighting
- Need to add lighting in the parking areas for safety. Consider along with the location of
trees.
Topic: Site Plan
Staff Review Letter Generated: 9/6/2011 at 2:49 pm
aty of
Fort Collins
Department: Current Planning
Community Deve._,..,lent and Neighborhood Services
281 North College Avenue
PO Box 580
Fort Collins, CO 80522
970.221.6750 970.224.6134 - fax fcgov.Com
Contact: Emma McArdle, 970-221-6206, emcardle(a)fcaov.com
Topic: General
Number: 12 Issue Originated: 09/02/2011
09/02/2011: 3.5.1 Building and Project Compatibility
- (B) architectural character - new shall be compatible with existing, this is very
questionable at this time. I recommend taking some time to work on the bulk, massing
and roof lines to try to be compatible with the surrounding residents.
- Something that will help staff evaluate this compatibility is providing some section cuts
and showing the building foot prints to show where breaks and relief is occurring.
We need color elevations, please see redline plans with additional comments
regarding need for relief (foot prints are needed to see what exterior breaks look like). Also
consider who you are designing for, the buildings look more like commercial buildings than
residential, maybe the use of awnings and some sort of shade structures will help.
Sections or perspectives would also give me a better sense of what is being proposed
than the flat elevations. They will also be helpful for the hearing and ultimate URA Board.
Number: 13
Issue Originated: 09/06/2011
09/06/2011: Regarding the parking comments for compact and long term spaces. I
brought this up with staff and regardless of the fact that those compact were approved
with the previous plan, the new plan and all the subsequent changes will require you to
bring the plan into full compliance including the compact spaces needing to be changed to
either long term or standard, or going with the compact option and no long term spaces.
Topic: Landscape Plans
Staff Review Letter Generated: 9/6/2011 at 2:49 pm
City of
Fort Col[ins
September 06, 2011
Robert Ross
Merten, Inc.
2017 17th St.
Boulder, CO 80302
Community Development and
Neighborhood Services
281 North College Avenue
PO Box 580
Fort Collins, CO 80522
970.221.6760
970.224,6134 - fax
fcgov.com
City staff and outside reviewing agencies have reviewed your submittal for Union Place Maior
Amendment, and we offer the following comments:
Department: Current Planning
Contact: Emma McArdle, 970-221-6206, emcardle(a)fcgov.com
Topic: General
Number: 1 Issue Originated:
08/31/2011
08/31/2011: Bubbles don't accurately show the changed areas. All building types have
changed except for the mixed -use buildings. They were approved as having individual
entrances before now central entrances are proposed. Either use bubbles to show that or
include a note describing changes.
Number: 2 Issue Originated:
08/31/2011
08/31/2011: Add note regarding how mail is handled. Also trash.
Number: 3 Issue Originated:
08/31/2011
08/31/2011: Regarding the neck -down at the drive aisles intersections, we'll defer to PFA.
Number: 4 Issue Originated:
08/31/2011
08/31/2011: Bike Parking - Can we get racks closer to the entries?
Number: 5 Issue Originated:
08/31/2011
08131/2011: Where is the 10' setback from the park coming? Can you take a few feet
here and add it off the parking area to allow more space for tree grates and some
foundation plantings? Same for easements off of the private street. Is this necessary at
9% worth looking into.
Number: 6 Issue Originated:
08/31/2011
08/31/2011: Vicinity map on site plan is off set with 2 of the same layers.
Number: 7 Issue Originated:
08/31/2011
08/31/2011: 8' setback and easement shown for Lot 1 Block 1, this is not correct. Take
off setback reference.
Number: 8 Issue Originated:
08/31/2011
08/31/2011: Building envelopes are not accurately shown, unless you are proposing
overhanging buildings over parking?
Staff Review Letter Generated: 9/6/2011 at 2:49 pm