Contact: Emma McArdle, 970-221-6206, emcardle(cDfcgov.com
1. Please see the Development Review Guide at www.fcqov.com/drq. This online guide
features a color -coded flowchart with comprehensive, easy to read information on each step
in the process. This guide includes links to just about every resource you need during
development review.
2. The entire Fort Collins Land Use Code (LUC) is available for your review on the web at
http://www.colocode.com/ftcollins/landuse/begin.htm.
3. This development proposal will be subject to all applicable standards of the Fort Collins
Land Use Code (LUC), including Article 3 General Development Standards, and Division
4.22 Service Commercial District (C-S). Please take the time to prepare your site and
landscape plans with these standards in mind, which include landscaping, pedestrian
connections and building design requirements (to name a few) that all apply to this
proposal..
4. If this proposal is unable to satisfy any of the requirements set forth in the LUC a
Modification of Standard Request will need to be submitted with your formal development
proposal. Please see Section 2.8.2 of the LUC for more information on criteria to apply for
a Modification of Standard.
5. An exhaustive list of submittal requirements for PDPs is available at:
http://fcgov.com/currentplanninq/pdf/project-dev-plan.pdf. There is a submittal checklist at
http://fcqov.com/currentplanning/pdf/r)dp.pd .
6. The proposed expansion and platting is subject to a Type 1 (Administrative) review process
in the C-S zone district. The applicant is not required to hold a neighborhood meeting, but if
you would like to have one to notify your neighbors of the proposal, please let me know and
I will can help you in setting a date, time and location for a meeting. Neighborhood
Meetings are a great way to get public feedback and avoid potential hick -up that may occur
later in the review process.
7. When you are ready to submit your formal Project Development Plan (PDP), please make
an appointment with Neighborhood and Building Services at (970)221-6750.
8. 1 will have more comments on the PDP once I have more detailed plans to review.
9. Please contact me with any questions along the way.
Page 6 of 6
City of
Fort Collins
Ennineering Dev Review
Contact: Marc Virata, 970-221-6567, mvirata(cDfcpov.com
1. Larimer County Road Impact Fees and Street Oversizing Fees are due at the time of
building permit. Please contact Matt Baker at 224-6108 if you have any questions.
2. Transportation Development Review Fee (TDRF) is due at the time of submittal. For
additional information on these fees,please see
hftp://www.fcgov.com/engineering/dev-review.php
3. Any damaged curb, gutter and sidewalk existing prior to construction, as well as streets,
sidewalks, curbs and gutters, destroyed, damaged or removed due to construction of this
project, shall be replaced or restored to City of Fort Collins standards at the Developer's
expense prior to the acceptance of completed improvements and/or prior to the issuance of
the first Certificate of Occupancy.
4. Please contact Joe Olson and Transportation Planning to schedule a scoping meeting and
determine if a traffic study is needed for this project.
5. Any public improvements must be designed and built in accordance with the Larimer
County Urban Area Street Standards (LCUASS).
6. This project is responsible for dedicating any right-of-way and easements that are
necessary for this project. Known dedications are the north half of the commercial local
street specified on the North College Access Control Plan which straddles the property and
the Lamplighter Motel property.
7. This site is adjacent to CDOT roadway and all access to the site is governed by an access
control plan. The access control plan will need to be followed and implemented with any
project. Plans will be routed to CDOT for review and approval and the applicant may need
to obtain access permits from CDOT.
8. Utility plans will be needed for this project.
9. A development agreement will be done with this project. The development agreement would
likely need to address in some manner the future construction of the commercial local street
shown on the North College Access Control Plan.
10. A repay will likely be filed on the property for the frontage improvements being done with the
North College improvement project which would require the repayment of frontage
improvements to the Urban Renewal Authority.
11. A Development Construction Permit (DCP) will need to be obtained prior to starting any
work on the site.
Electric
Contact: Justin Fields, 970-224-6150, ifields(&fcciov.com
1. No comments.
Page 5 of 6
Cfty of
ort Co ins
impervious area over 350 sq.-ft. In addition, there is a $1,045.00/acre review fee. No fee is
charged for existing impervious area. These fees are to be paid at the time each building
permit is issued. Information on fees can be found on the City's web site at
http://www.fcgov.com/utilities/builders-fees.php or by contacting Jean Pakech at 221- 6375.
Poudre Fire Authority
Contact: Carle Dann, 970-416-2869, cdann(a)poudre-fire.org
1. WATER SUPPLY - Fire hydrants, where required, must be the type approved by the water
district having jurisdiction and the Fire Department. Hydrant spacing and water flow must
meet minimum requirements based on type of occupancy. Minimum flow and spacing
requirements include: Commercial, 1,500 gpm at 20 psi residual pressure, spaced not
further than 300 feet to the building, on 600-foot centers thereafter; residential within Urban
Growth Area, 1,000 gpm at 20 psi residual pressure, spaced not further than 400 feet to the
building, on 800-foot centers thereafter; residential outside Urban Growth Area, 500 gpm at
20 psi residual pressure, spaced not further than 400 feet to the building, on 800-foot
centers thereafter.
These requirements may be modified if buildings are equipped with automatic fire sprinkler
systems.
2006 International Fire Code 508.1 and Appendix B
2. REQUIRED ACCESS - Fire access roads (fire lanes) shall be provided for every facility,
building or portion of a building hereafter constructed or moved into or within the PFA's
jurisdiction when any portion of the facility or any portion of an exterior wall of the first story
of the building is located more than 150 feet from fire apparatus access as measured by an
approved route around the exterior of the building or facility. This fire lane shall be visible by
painting and signage, and maintained unobstructed at all times. A fire lane plan shall be
submitted for approval prior to installation. In addition to the design criteria already
contained in relevant standards and policies, any new fire lane must meet the following
general requirements:
- Be designed as a flat, hard, all-weather driving surface (asphalt or concrete) capable
of supporting fire apparatus weights. Compacted road base shall be used only for
temporary fire lanes or at construction sites.
- Have appropriate maintenance agreements that are legally binding and enforceable.
- Be designated on the plat as an Emergency Access Easement.
Maintain the required minimum width of 20 feet throughout the length of the fire lane
(30 feet on at least one long side of the building when the structures is three or more
stories in height).
If the building is equipped throughout with an approved automatic fire -sprinkler system, the
fire code official is authorized to increase the dimension of 150 feet.
2006 International Fire Code 503.1.1, 503.2.3, 503.3, 503.4 and Appendix D
3. BUILDING AREA - Buildings of Type V construction that exceed 5,000 square feet shall be
fire contained or fire sprinklered. 2006. International Fire Code New Table 903.1 and Section
702
Page 4 of 6
�l
F6rt Collins
-
fire line and fire hydrant.
3. The existing water service is a 3/<-inch service which connects to the 4-inch water main in
front of the Lamplighter Motel on the west side of college.
4. No changes are planned to the existing domestic service.
Transportation Planning
Contact: Jennifer Petrik, 970-416-2471, ipetrikAfcgov.com
1. Bicycle parking is required. Bicycle parking must be on a hard surface, convenient to the
entrance and protected from the elements if possible.
2. Coordination with the North College roadway improvements project associated with the
North College Marketplace appears to be underway. The contact for that project is Matt
Baker.
Stormwater
Contact: Glen Schlueter, 970-224-6065, gschlueter(cDfcgov.com
1. Drainage requirements and fees are based on new impervious area; therefore, it is
important to document the existing impervious area. To determine these requirements, an
exhibit showing the existing and proposed impervious areas is needed. In the Dry Creek
drainage basin, a drainage and erosion control report and construction plans are required if
there is an increase in impervious area greater than 1000 square feet. These must be
prepared by a Professional Engineer registered in Colorado. If the new impervious area is
less than 1000 square feet, a drainage letter is sufficient as long as it confirms compliance
with the existing drainage patterns or justifies a change in the drainage patterns. A grading
plan is still required.
2. Since the site is being platted, the existing storm sewer lines need to have easements
shown on the new plat in addition to any new easements needed for detention for the
additions and the parking lot.
3. In the Dry Creek basin, the two year historic release rate is 0.2 cfs/acre. The drainage
outfall for the site may require obtaining easements from this property to Willox Ct. since
that appears to be the present outfall for the drainage. With detention, some of the site
could possibly drain to the existing storm lines from the north if the pipe under College Ave.
is replaced. The drainage system from the County development north of the Larimer and
Weld ditch has not been working properly for years. Options for repair of that system are
being considered by the Stormwater Utility.
4. Water quality treatment is required as described in the Urban Storm Drainage Criteria
Manual, Volume 3 — Best Management Practices (BMPs).
5. The Windsor Reservoir and Canal Company owns and operates the Eaton Ditch
(Larimer-Weld Canal) along the north property line. The ditch company will need to
approve the plans if there is any grading near the ditch. The contact is Bill Johnston,
Superintendent; 222-0090 (Cell), 454-3377.
6. The design of this site must conform to the drainage basin design of the Dry Creek Master
Drainage Plan as well the City's Design Criteria and Construction standards.
7. The 2010 City-wide development fee (PIF) is $6,313/acre ($0.145/sq.ft.) for new
Page 3 of 6
CONCEPTUAL REVIEW STAFF COMMENTS
Meeting Date
Item:
Applicant
Land Use Data:
December 7, 2009
1845 N College - Legacy Auto Expansion
Gary Farkas
1845 N College Ave
Fort Collins, CO 80524
legacytractot@yahoo.com
Fort Collins
The applicant is proposing an expansion of an existing building as well as expanding the uses onto
the neighboring site. The existing building is 36'x48'; the expansion will add a 100' by 60' structure.
The proposed expansion onto a new site is subject to a type 1 (administrative) review process in the
Service Commercial (CS) District.
Comments:
Zoning
Contact: Peter Barnes, 970-416-2355, pbarnesofc4ov.com
1. Zoned CS - Exiting development is the Platinum Auto Brokers PUD. The proposed building
expansion and outdoor parking/display are located on property not within the boundaries of
the PUD. This means that the changes can't be approved by minor amendment. Rather a
new PDP is required. Tractor sales aren't specifically listed as permitted, but as long as the
types of tractors for sale are limited to the size/type of those currently being sold on the
original PUD site, it's been determined that the use is a permitted use, to be included in the
vehicle and boat sales use listed in the CS zone. The development will be subject to a Type
1 public hearing process.
2. The new parcel is not platted. Therefore, it will need to be platted as part of the process.
3. The=parking/dissplay=lot-.must°be°hard surfacedsand=comply=with=theandscape;and design
standard=in-Sec._3-2-1=and_3.2.2.of the,L-and=Us Ce ode.
4. The PDP must include/show 2 phases. Jhe 1st phase would be_t_h, e.interim, layouttw/gravels
would_be_the_permanent.plan:.
Water -Wastewater
Contact: Roger Buffington, 970-221-6854, rbuffingtonOfcaov.com
1. The water and sewer mains in the vicinity of this site include a 4-inch water main which
extends from Willox to a point in front of the Lamplighter Motel and a 6-inch sewer at the
southwest corner of the site.
2. A water main extension may be needed to meet the Poudre Fire Authority requirements for
Page 2 of 6
City of
Fort Collins
December 17, 2009
Gary Farkas
1845 N College Ave
Fort Collins, CO 80524
RE: 1845 N College - Legacy Auto Expansion
Dear Gary,
Community Development and
Neighborhood Services
281 North College Avenue
PO Box 580
Fort Collins, CO 80522
970.221.6750
970.224.6134 - fax
fcgov.com/.currentp/anning
Attached, please see a copy of Staffs comments concerning the request referred to as the 1845
N College -Legacy Auto Expansion, which was presented before the Conceptual Review
Team on December 7, 2009.
The comments offered informally by staff during the Conceptual Review will assist you in
preparing the detailed components of the project application. Modifications and additions to these
comments may be made at the time of formal review of this project.
��.. If you should have any questions regarding these comments or the next steps in the review
process, please feel free to contact me at 970-221-6206.
Sincerely,
Emma McArdle,
City Planner
CC: Emma McArdle, Current Planning
Justin Fields, Electric
Marc Virata, Engineering Dev Review
Carie Dann, Poudre Fire Authority
Glen Schlueter, Stormwater
Jennifer Petrik, Transportation Planning
Roger Buffington, Water -Wastewater
Peter Barnes, Zoning
281 North College Avenue - P.O. Box 580 - Fort Collins, CO 80522 - 0580 — (970) 221-6750 - FAX (970) 224-6134