HomeMy WebLinkAboutCENTERPOINT PLAZA (RE-APPLICATION) - PDP - PDP150014 - CORRESPONDENCE -08/12/2015: The meter pit needs to be located in a landscape area. Comment Number: 2 Comment Originated: 08/12/2015 08/12/2015: Please show the sewer service extension to the building. Comment Number: 3 Comment Originated: 08/12/2015 08/12/2015: Please show the proposed wet utilities on the landscape plan and provide the required separation distances. redlines. Comment Number: 23 Comment Originated: 08/06/2015 08/06/2015: There are line over text issues. See redlines. Comment Number: 24 Comment Originated: 08/06/2015 08/06/2015: There is text that needs the size increased. See redlines. Comment Number: 25 Comment Originated: 08/06/2015 08/06/2015: There is text that needs to be masked. Mask all text in hatched areas. See redlines. Comment Number: 26 Comment Originated: 08/06/2015 08/06/2015: The lighter background text & linework and vicinity map linework will not scan or reproduce. Please darken it up. See redlines. Comment Number: 27 Comment Originated: 08/06/2015 08/06/2015: Abbreviated legal descriptions are not accepted, unless it is taken from a recorded deed. If this is the case, please provide a copy of the document to confirm the description. Comment Number: 28 Comment Originated: 08/06/2015 08/06/2015: Please explain the "Department Of Public Works". See redlines. Department: Traffic Operation Contact: Martina Wilkinson, 970-221-6887, mwilkinson(a)fcgov.com Topic: General Comment Number: 1 Comment Originated: 08/12/2015 08/12/2015: The original approval was for office and retail use. With no changes, no further traffic analysis is needed. Department: Water Conservation Contact: Eric Olson, 970-221.6704, eolson@fcgov.com Topic: General Comment Number: 1 Comment Originated: 08/11/2015 08/11/2015: Perovskia Atriplicifolia (Russian Sage) has been removed from the City of Fort Collins Plant List. Please replace with a plant variety from the current list. If you have questions contact Eric Olson at eolson@fcgov.com or 970-221-6704. Comment Number: 2 Comment Originated: 08/11/2015 08/11/2015: The irrigation plan is incomplete. Please refer to the provisions outlined in Section 3.2.1(J) of the Land Use Code. Identify grass type(s) and show a water budget for site, identify hydrozones as well. Direct questions concerning irrigation requirements to Eric Olson, at 221-6704 or eolson@fcgov.com Department: Water -Wastewater Engineering Contact: Wes Lamarque, 970-416-2418, wlamargueofcgov.com Topic: General Comment Number: 1 Comment Originated: 08/12/2015 08/06/2015: Please explain the "Department Of Public Works". See redlines. Comment Number: 9 Comment Originated: 08/06/2015 08/06/2015: All benchmark statements need to match on all sheets. Comment Number: 10 Comment Originated: 08/06/2015 08/06/2015: There are line over text issues. See redlines. Comment Number: 11 Comment Originated: 08/06/2015 08/06/2015: The lighter background text & linework will not scan or reproduce. Please darken it up. See redlines. Comment Number: 12 Comment Originated: 08/06/2015 08/06/2015: There are spelling issues with some text. See redlines. Comment Number: 13 Comment Originated: 08/06/2015 08/06/2015: There are text over text issues. See redlines. Comment Number: 14 Comment Originated: 08/06/2015 08/06/2015: Please tie the coordinate values shown for utilities to the project boundary. We would prefer that this be done by adding property corner values to each sheet, or showing the property corner values on the horizontal control plans and adding a note to each sheet with coordinate values. Comment Number: 15 Comment Originated: 08/06/2015 08/06/2015: Please reduce text size, so that text will fit in symbols. See redlines. Topic: Landscape Plans Comment Number: 16 Comment Originated: 08/06/2015 08/06/2015: Please change the name to "Centerpoint Plaza First Replat". The name need to match on all sheets. See redlines. Comment Number: 17 Comment Originated: 08/06/2015 08/06/2015: There are cut off text issues. See redlines. Comment Number: 18 Comment Originated: 08/06/2015 08/06/2015: There are line over text issues. See redlines. Comment Number: 19 Comment Originated: 08/06/2015 08/06/2015: The lighter hatching, background text & linework will not scan or reproduce. Please darken it up. See redlines. Topic: Lighting Plan Comment Number: 20 Comment Originated: 08/06/2015 08/06/2015: Please change the name to "Centerpoint Plaza First Replat". See redlines. Comment Number: 21 Comment Originated: 08/06/2015 08/06/2015: There are line over text issues. See redlines. Topic: Site Plan Comment Number: 22 Comment Originated: 08/06/2015 08/06/2015: Please change the name to "Centerpoint Plaza First Replat". See 08/12/2015: Clarification is needed for the northeast corner of the site where the storm sewer picks up the flows from the north. Department: Technical Services Contact: Jeff County, 970-221-6588, icounty(a)fcgov.com Topic: Building Elevations Comment Number: 1 Comment Originated: 08/06/2015 08/06/2015: Please change the name to "Centerpoint Plaza First Replat". See redlines. Comment Number: 2 Comment Originated: 08/06/2015 08/06/2015: The lighter text & linework will not scan or reproduce. Please darken it up. See redlines. Topic: Construction Drawings Comment Number: 3 Comment Originated: 08/06/2015 08/06/2015, Please change the name to "Centerpoint Plaza First Replat". The name need to match on all sheets. See redlines. Comment Number: 4 Comment Originated: 08/06/2015 08/06/2015: The City has moved to the NAVD88 vertical datum. Please provide the following information in the EXACT format shown below. PROJECT DATUM: NAVD88 BENCHMARK # w/ DESCRIPTION ELEVATION: BENCHMARK # w/ DESCRIPTION ELEVATION: PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88 - X.XX'. Comment Number: 5 Comment Originated: 08/06/2015 08/06/2015: The lighter linework in the vicinity map will not scan or reproduce. Please darken it up. See redlines. Comment Number: 6 Comment Originated: 08/06/2015 08/06/2015: The legal description is not necessary, but may remain with the corrections made as noted. Abbreviated legal descriptions are not accepted, unless it is taken from a recorded deed. If this is the case, please provide a copy of the document to confirm the description. Comment Number: 7 Comment Originated: 08/06/2015 08/06/2015: The titles in the sheet index do not match the titles on the noted sheets. See redlines. Comment Number: 8 Comment Originated: 08/06/2015 Comment Number: 1 Comment Originated: 08/06/2015 08/06/2015: Light and Power has electric facilities along the south side of Midpoint Dr that could be utilized to provide both single or three phase power. Comment Number: 2 Comment Originated: 08/06/2015 08/06/2015: Please provide a one line diagram and a C-1 form to Light and Power Engineering. The C-1 form can be found at: http://zeus.fcgov.com/utils-procedures/files/EngWiki/WikiPdfs/C/C-1 Form.pdf Comment Number: 3 Comment Originated: 08/06/2015 08/06/2015: Development and capacity charges will apply at owner's expense. Comment Number: 4 Comment Originated: 08/06/2015 08/06/2015: Please contact Light & Power Engineering if you have any questions at 221-6700. Please reference our policies, development charge processes, and use our fee estimator at http://www.fcgov.com/utilities/business/builders-and-developers. Department: Stormwater Engineering Contact: Jesse Schlam, 970-218.2932, jschlam(a�fcgov.com Topic: Erosion Control Comment Number: 1 Comment Originated: 08/04/2015 08/04/2015: The site disturbs more than 10,000 sq-ft and in a sensitive area, therefore Erosion and Sediment Control Materials need to be submitted for FDP. The erosion control requirements are in the Stormwater Design Criteria under the Amendments of Volume 3 Chapter 7 Section 1.3.3. Current Erosion Control Materials Submitted do not meet requirements. Please submit; Erosion Control Plan (has redline comments), Erosion Control Report (not submitted), and an Escrow / Security Calculation (not submitted). If you need clarification concerning this section, or if there are any questions please contact Jesse Schlam 970-218-2932 or email @ jschlam@fcgov.com Contact: Wes Lamarque, 970.416-2418, wlamargue(a.fcgov.com Topic: General Comment Number: 2 Comment Originated: 08/12/2015 08/12/2015: Low impact development is required for all new development. This includes 25% of the site's vehicular pavement to be porous and 50% of the site's impervious area to be treated by a LID technique. Comment Number: 3 Comment Originated: 08/12/2015 08/12/2015: Please provide discussion in the text of the drainage report about the LID design and provide our standard LID table in the report and on the drainage plan. Comment Number: 4 Comment Originated: 08/12/2015 08/12/2015: Please provide exerpts from the Filing 1 drainage report to backup the data used for this design. Comment Number: 5 Comment Originated: 08/12/2015 08112/2015: Please provide contour information for all parts of the site on the grading plan. Comment Number: 6 Comment Originated: 08/12/2015 a pre -submittal meeting. Applicants should be prepared to present site plans, floor plans, and elevations and be able to discuss code issues of occupancy, square footage and type of construction being proposed. Construction shall comply with the following adopted codes as amended: 2012 International Building Code (IBC) 2012 International Residential Code (IRC) 2012 International Energy Conservation Code (IECC) 2012 International Mechanical Code (IMC) 2012 International Fuel Gas Code (IFGC) 2012 International Plumbing Code (IPC) as amended by the State of Colorado 2014 National Electrical Code (NEC) as amended by the State of Colorado Fort Collins has amendments to most of the codes listed above. See the fcgov.com web page to view them. Accessibility: State Law CRS 9-5 & ICC/ANSI All 17.1-2009. Snow Load Live Load: 30 PSF I Ground Snow Load 30 PSF. Frost Depth: 30 inches. Wind Load: 100- MPH 3 Second Gust Exposure B. Seismic Design: Category B. Climate Zone: Zone 5 Energy Code Use 1. Single Family; Duplex; Townhomes: 2012 IRC Chapter 11 or 2012 IECC. 2. Multi -family and Condominiums 3 stories max: 2012 IECC residential chapter. 3. Commercial and Multi -family 4 stories and taller: 2012 IECC commercial chapter. Project specific concerns: 1. Upgraded insulation is required for buildings using electric heat or cooling. 2. Exterior walls and roof must meet a STC (sound resistance) rating of 40 min. if building located within 1000ft to train tracks for certain occupancies. 3. Low -flow Watersense plumbing fixtures (toilet, faucets, shower heads) are required. 4. Special combustion safety requirements for natural draft gas appliances. 5. Low VOC interior finishes. City of Fort Collins Building Services Plan Review 416-2341 Department: Light And Power Contact: Tyler Siegmund, 970-221.6501, tsie4mund(.fcgov.com Topic: General 08/05/2015: At the time of construction/landscaping, please ensure that the seed mix in the detention area is drilled before applying the hydroseed pulp, rather than mixing the seed with the pulp before broadcasting. Department: Forestry Contact: Tim Buchanan, 970.221-6361, tbuchanan(a)fcgov.com Topic: Landscape Plans Comment Number: 1 Comment Originated: 08/12/2015 08/12/2015: Use the newly developed landscape and project notes on the plans. These notes are available from the City Project Planner, Clay Frickey Comment Number: 2 Comment Originated: 08/12/2015 08/12/2015: If there are any existing trees on the site contact the City Forester for an on -site meeting to obtain tree inventory and mitigation information to incorporate on the plans. LUC 3.2.1 F Comment Number: 3 Comment Originated: 08/12/2015 08/12/2015: The tree with the scientific name Cercis canadensis is labeled with the common name Shadblow Serviceberry, but it should be Eastern Redbud, The 4 locations where the Redbud are shown on the plan should be planted with a canopy shade tree. (LUC 3.2.1 E 5 c) This standard also pertains where the Bigtooth maples are used in similar parking lot island areas. There are around 4 island locations where bigtooth maple is used, but they are not considered canopy shade trees. At these locations the bigtooth maple should be changed to a canopy shade tree. Comment Number: 4 Comment Originated: 08/12/2015 08/12/2015: The landscape area along the east side of the parking area to the west of the building is a perimeter parking lot area. Trees should be planted at one tree per 40 feet in these areas. (LUC 3.2.1 D 4 a) Department: Internal Services Contact: Russell Hovland, 970-416.2341, rhovlandWcgov.com Topic: Building Insp Plan Review Comment Number: 1 Comment Originated: 08/11/2015 08/11 /2015: Building Permit Pre -Submittal Meeting: Pre -Submittal meetings are offered to assist the designer/builder by assuring, early on in the design, that the new commercial or multi -family projects are on track to complying with all of the adopted City codes and Standards listed below. The proposed project should be in the early to mid -design stage for this meeting to be effective and is typically scheduled after the Current Planning conceptual review meeting. Applicants of new commercial or multi -family projects are advised to call 416-2341 to schedule Department: Environmental Planning Contact: Rebecca Everette, 970-416.2625, reverette(cUcgov.com Topic: General Comment Number: 5 Comment Originated 08/05/2015: Our city has an established identity as a forward -thinking community that cares about the quality of life it offers its citizens and has many sustainability programs and goals that may benefit your project. Of particular interest may be the: 1. ClimateWise program: http://www.fcgov.com/climatewise/ 2. Zero Waste Plan and the Waste Reduction and Recycling Assistance Program (WRAP): hftp://www.fcgov.com/recycling/pdf/_20120404_WRAP_ProgramOverview. pdf, contact Caroline Mitchell at 970-221-6288 or cmtichell@fcgov.com 3. Green Building and the Climate Action Plan: hftp://www.fcgov.com/enviro/green-building.php, contact Tony Raeker at 970-416-4238 or traeker@fcgov.com 4. Nature in the City Strategic Plan: hftp://www.fcgov.com/planning/natureinthecity/? key=advanceplanning/natureinthecity/, contact Justin Scharton at 970-221-6213 orjschafton@fcgov.com Please consider the City6s sustainability goals and ways for your development to engage with these efforts. Topic: Landscape Plans Comment Number: 1 08/05/2015 Comment Originated: 08/05/2015 08/05/2015: It appears that the existing trees on the site will be removed with this development. The applicant should make note of Article 3.2.1(C) that requires developments to submit plans that "...(4) protects significant trees, natural systems, and habitat". Note that a significant tree is defined as a tree having DBH (Diameter at Breast Height) of six inches or more. If any of the trees within this site have a DBH of greater than six inches, a review of the trees shall be conducted with Tim Buchanan, City Forester (221 6361) to determine the status of the existing trees and any mitigation requirements that could result from the proposed development. Comment Number: 2 Comment Originated: 08/05/2015 08/05/2015: If tree mitigation is necessary, please include a note on the tree mitigation plan or landscape plan, as appropriate, that requires a tree removal to occur outside of the migratory songbird nesting season (February 1-July 31), or that a survey be conducted prior to removal to ensure no active nests in the area. Comment Number: 3 Comment Originated: 08/05/2015 08/05/2015: A list of species included in the hydroseed seed mix needs to be included on the landscape plan. A mix that incldues native flowering plants in addition to native grasses is preferred. Comment Number: 4 Comment Originated: 08/05/2015 Comment Number: 3 Comment Originated: 08/10/2015 08/10/2015: Landscape plan Need a note that identifies that the developer/owner is responsible for the maintenance of the landscaping shown including that within the right-of-way. Need to show the PRPA pole location — looks like they will conflict with a couple of new trees proposed. PRPA will also need to approve all the landscaping shown within their easement. Label the PRPA easement. What about the new curbed area along the east property line? What landscaping is to occur in this area. The proposed lights need to be shown on this plan. Comment Number: 4 Comment Originated: 08/10/2015 Need City signature block on the cover sheet of the utility plans. Comment Number: 5 Comment Originated: 08/10/2015 08/10/2015: Cover sheet— if you are going to list the Standard Specifications then you need to include all the others as well. Comment Number: 6 Comment Originated: 08/10/2015 08/10/2015: In the general notes — the note regarding the drainage report needs to include the date of the report and who it is by. The note identifies the report as being for Centerpoint Plaza First Replat. This is what is should be, but the report submitted says it is for Centerpoint Plaza which is a slightly different area. Make sure the note and the document match. Comment Number: 7 Comment Originated: 08/10/2015 08/10/2015: What does the shading in the plans represent? On one sheet is looks like it is labeled as asphalt, but that doesn't make sense when a portion of the area that is shaded as a drainage outfall channel in it. Plans are not clear as to what is happening in this area as one sheet shows curbing, but others don't. Comment Number: 8 08/10/2015: Label the PRPA poles Comment Number: 9 Comment Originated: 08/10/2015 Comment Originated: 08/10/2015 08/10/2015: Need a letter of intent for work shown outside of the existing easements. All work shown on the plans needs to be within existing or future easements.. The letter of intent shall be provided before the project can be scheduled for hearing. Comment Number: 10 Comment Originated: 08/10/2015 08/10/2015: Many of the details that you have on the plans are old details. If they are to be used within the public right-of-way then they need to be replaced and updated with current City details. If they are to be used on -site then you can keep them on the plans, but you need to remove the reference to them being City details and label them for on -site use only. Comment Number: 11 Comment Originated: 08/10/2015 08/10/2015: You don't need the street intersection detail as you would not be reconstructing a street intersection and the driveway details are not needed either unless you are planning on using them for on -site work. Comment Number: 12 Comment Originated: 08/10/2015 08/10/2015: See additional notes on the redlined plans. Topic: Lighting Plan Comment Number: 4 Comment Originated: 08/10/2015 08/10/2015: From the lighting plan submitted, it is unclear whether or not the proposed fixtures meet the design standards outlined in section 3.2.4(D) of the Land Use Code. Please revise the lighting plan with more detailed information about the proposed lighting fixtures. Light sources should be fully concealed and have sharp cut-off capability. Light sources should also minimize contrast with light produced from other sources and produce an unobtrusive degree of brightness in both illumination levels and color rendition. Topic: Site Plan Comment Number: 1 Comment Originated: 08/05/2015 08/05/2015: Please provide a break down of the amount of square footage for each proposed use of the building. The parking requirements for office and retail are different and based on the square footage of each use. This information will allow us to calculate the proper number of parking spaces required for this development. Comment Number: 5 Comment Originated: 08/11/2015 08111/2015: Please show the easement for the PRPA transmission lines on the site plan. Comment Number: 6 Comment Originated: 08/11/2015 08/11/2015: The proposed site plan does not show any sidewalk connections to the adjacent development to the north. To meet code section 3.2.2(C)(6), you will need to provide a sidewalk connection to the adjacent development to form a continuous sidewalk network. Contact: Katie Dorn, kdorn@fcgov.com Topic: General Comment Number: 1 Comment Originated: 08/11/2015 08/11/2015: No comments warranted. Department: Engineering Development Review Contact: Sheri Langenberger, 970-221-6573, slangenberger@fcgov.com Topic: General Comment Number: 1 Comment Originated: 08/10/2015 08/10/2015: All documents associated with this project need to be labeled as 'Centerpoint Plaza First Replat'. If you leave off the First Replat then they are referencing the wrong project. Comment Number: 2 Comment Originated: 08/10/2015 08/10/2015. Site plan Need to show the PRPA pole locations. Missing a curbline that is shown on the utility plans that crosses the east property line and defines the driveway into the site. For note 6 to work the firelane needs to be labeled on the plans. Note 7 — light and power does not have specifications for site lighting that is identified in the Land Use Code. There is not a department of Public Works in the City of Fort Collins Fort Collins Community Development and Neighborhood Services 281 North College Avenue PO Box 580 Fort Collins, CO 80522 970.221.6750 970.224.6134 - fax fcgov. coMdevelopmenheview August 14, 2015 Patricia Parish RMG- Rocky Mountain Group 2910 Austin Buffs, Ste 100 Colorado Springs, CO 80919 RE: Centerpoint Plaza, PDP150014, Round Number 1 Please see the following summary of comments from City staff and outside reviewing agencies for your submittal of the above referenced project. If you have questions about any comments, you may contact the individual commenter or direct your questions through the Project Planner, Clay Frickey, at 970-224-6045 or cfrickey@fcgov.com. Comment Summary: Department: Planning Services Contact: Clay Frickey, 970-224-6045, cfrickev(&fcaov.com Topic: Building Elevations Comment Number: 2 Comment Originated: 08/05/2015 08/05/2015: Please indicate the materials to be used on the trash and recycling enclosure. Topic: Landscape Plans Comment Number: 3 Comment Originated: 08/10/2015 08/10/2015: Per Land Use Code section 3.2.1(E)(3)(b)(2), please include a water budget chart that shows the annual water use for the proposed landscaping. The overall water budget shall not exceed 15 gallons/square foot over the entire site. Comment Number: 7 Comment Originated: 08/11/2015 08/11/2015: Please show the PRPA transmission lines on the landscape plan. Comment Number: 8 Comment Originated: 08/11/2015 08/11/2015: You will not be able to plant canopy shade trees under the PRPA transmission lines. Please replace the proposed canopy shade trees under the transmission lines with ornamental sized trees.