HomeMy WebLinkAboutDUTCH BROTHERS COFFEE DRIVE-THROUGH - FDP - FDP160018 - CORRESPONDENCE -Topic: Construction L,,awings Comment Number: 6 Comment Originated: 05/09/2016 05/09/2016: There are line over text issues. See redlines. Topic: Landscape Plans Comment Number: 3 Comment Originated: 05/09/2016 05/09/2016: There are line over text issues. See redlines. Topic: Lighting Plan Comment Number: 4 05/09/2016: No comments. Topic: Site Plan Comment Originated: 05/09/2016 Comment Number: 1 Comment Originated: 05/09/2016 05/09/2016: Some of the easement descriptions shown are incorrect. If they are going to stay on the plan, they should match what is shown on the Subdivision Plat. Comment Number: 2 Comment Originated: 05/09/2016 05/09/2016: There are line over text issues. See redlines. Department: Water -Wastewater Engineering Contact: Wes Lamarque, 970-416-2418, wlamargue@fcgov.com Topic: General Comment Number: 1 05/10/2016: No comments. Comment Originated: 05/10/2016 n http://zeus.fcgov.,,in/utils-procedures/files/EngWikiMikiPdfs/L,, -1 Form.pdf Comment Number: 3 Comment Originated: 05/10/2016 05/10/2016: Contact Light and Power Engineering to coordinate the transformer and electric meter locations, please show the locations on the utility plans. Comment Number: 4 Comment Originated: 05/10/2016 05/10/2016: Electric Capacity Fee, Building Site charges and any system modification charges necessary will apply to this development. Comment Number: 5 Comment Originated: 05/10/2016 05/10/2016: A 40 feet separation on both sides of the light is required between canopy trees and streetlights. A 15 feet separation on both sides of the light is required between ornamental trees and streetlights. Comment Number: 6 Comment Originated: 05/10/2016 05/10/2016: Transformer locations shall be within 10' of a paved surface and must have a minimum of an 8' clearance from the front side and a 3' clearance around the sides and rear. (1000 kVA up to 2500 kVA requires 4' around the sides and rear.) Comment Number: 7 Comment Originated: 05/10/2016 05/10/2016: Please contact Light & Power Engineering if you have any questions at 221-6700. Please reference our policies, development charge processes, and use our fee estimator at http://www.fcgov.com/utilities/business/builders-and-developers. Department: Stormwater Engineering Contact: Jesse Schlam, 970-218-2932, ischlam@fcqov.com Topic: Erosion Control Comment Number: 1 Comment Originated: 05/10/2016 05/10/2016: No Comment issues resolved with prior submittal. Contact: Wes Lamarque, 970-416-2418, wlamargue@fcgov.com Topic: General Comment Number: 2 Comment Originated: 05/10/2016 05/10/2016: Please label underdrain to be 2-inches above subgrade on the porous paver detail. Comment Number: 3 Comment Originated: 05/10/2016 05/10/2016: Please include the drainage plan in the Utility Plan set. Department: Technical Services Contact: Jeff County, 970-221-6588, Topic: Building Elevations Comment Number: 5 05/09/2016: No comments. icounty@fcqov.com Comment Originated: 05/09/2016 3 Comment Number: 5 �,omment Originated: 05/10/2016 05/10/2016: On the Lighting Plan, for fixture CC, under Description, the Description appears to be incomplete. Comment Number: 6 Comment Originated: 05/10/2016: On the Lighting Plan, there are 14 CC's indicated in the Schedule but only 13 shown on the plan. It appears that CC-19 is missing or only a quantity of 13 is intended. Please verify and correct as necessary. Comment Number: 7 Comment Originated: 05/10/2016: Repeat Comment: On the Lighting Plan, please add a note that clearly specifies that fixtures DID must be equipped and installed with "Flush Mount and Flat Lens." Department: Engineering Development Review Contact: Marc Ragasa, 970.221.6603, mragasa@fcgov.com Topic: General 05/10/2016 05/10/2016 Comment Number: 1 Comment Originated: 05/11/2016 05/11/2016: Add project title " Dutch Bros Coffee to Individual title block sheets Comment Number: 2 Comment Originated: 05/11/2016 05/11/2016: Update the drainage and erosion control study date to the most recent in 19 of the General Notes and 2 of the Storm Drainage Notes. Comment Number: 3 Comment Originated: 05/11/2016 05/11/2016: As shown on the Utility Plans, the fire lane is only about 17' wide. The building envelope extends into the drive aisle and reduces the overall width of the emergency access easement. Per conversations with PFA, Bear Mountain Drive will be sufficient to provide fire access to the building. Comment Number: 4 Comment Originated: 05/11/2016 05/11/2016: On the horizontal Control Plan, it may be a good idea to include a concrete band/collar to the north and south of the pavers so they stay in place and butt up against asphalt. Comment Number: 5 Comment Originated: 05/11/2016 05/11/2016: The Fire Access Road Sign has been updated. Please use the revised detail. Comment Number: 6 Comment Originated: 05/11/2016 05/11/2016: Move the signature block on Sheet 8 to the lower right corner. Department: Light And Power Contact: Coy Althoff, CAlthoff@fcgov.com Topic: General Comment Number: 1 Comment Originated: 05/10/2016 05/10/2016: Light & Power can serve this property with the requested single phase electric service. Comment Number: 2 Comment Originated: 05/10/2016 05/10/2016: Please provide a one line diagram and a C-1 form to Light and Power Engineering. The C-1 form can be found at: 2 City of �F6r-t Collins Community Development and Neighborhood Services 281 North College Avenue PO Box 580 Fort Collins, CO 80522 970.221.6750 970.224.6134 - fax fcgov.com/deve/opmentrev/*ew May 18, 2016 Nate Frary 729 Oklahoma St Kennewick, WA 99336 RE: Dutch Brothers Coffee Drive -Through, FDP160018, Round Number 1 Please see the following summary of comments from City staff and outside reviewing agencies for your submittal of the above referenced project. If you have questions about any comments, you may contact the individual commenter or direct your questions through the Project Planner, Ted Shepard, at 970-221-6343 ortshepard@fcgov.com. Comment Summary: Department: Planning Services Contact: Ted Shepard, 970-221-6343, tshepard@fcgov.com Topic: General Comment Number: 1 Comment Originated: 05/10/2016 05/10/2016: On the Site Plan, please indicate how many cars can be stacked behind the Menu Board without impacting the private north -south drive. Comment Number: 2 Comment Originated: 05/10/2016: On the Site Plan, for Site Plan Note number 11, please add that the bike rack must be permanently anchored "to concrete and not interfere with walkways and landscaping." Comment Number: 3 Comment Originated: 05/10/2016: Please make double sure that the sloping mansard is of sufficient height to totally screen the roof -mounted mechanical equipment. If after installation, this equipment is not screened from the two public streets, it becomes very difficult to mitigate after the fact. Comment Number: 4 05/10/2016 05/10/2016 Comment Originated: 05/10/2016 05/10/2016: On the Lighting Plan, the Schedule indicates that the Light Loss Factor for fixtures CC and DID is 0.74 and 0.65 respectively. These must be recalibrated for a Light Loss Factor of 1.00. This may require the Illuminance Plan to be adjusted.