HomeMy WebLinkAboutWILL SUBDIVISION, 742 - 746 N. COLLEGE - PDP/FDP - 20-98 - SUBMITTAL DOCUMENTS - ROUND 1 - CORRESPONDENCE-CONCEPTUAL REVIEWC. The Stormwater Utility believes that there is an additional pipe or box
culvert for the Josh Ames Ditch under the parking lot on the south side of
the existing building. An easement is needed for it if it does exist.
d. The Lake Canal is the ditch with the existing bridge on North College
Avenue.
e. If it is possible to retrofit some water quality Best Management Practices,
they should be included in the new plan.
f. A portion of this site could be in the shallow flooding area of Dry Creek
and could also be in the Poudre River floodplain. If so, new structures
must be at least 18" above the 100-year water surface. Existing structures
can be improved up to 50% of the value of the existing structure without
complying to floodplain requirements. Your project engineer will have to
identify the floodplain limits.
Please contact Glen, at 221-6589, if you have questions about these comments.
7. Pedestrian connections to the site must be in compliance with the new LUC. The
Transportation Impact Study and Multi -Modal Level of Service Study associated
with this change of use request will determine how they should occur.
8. Public transit service along North College Avenue currently exists only one-way
into town from the north. The intent is to enhance the service and provide two-
way bus service on North College. Also, space should be reserved for a future
bus stop in the area, with no obstructions.
9. The trash collection and enclosure should be upgraded to provide for and
accommodate recycling, as possible.
10. Because of the proximity of this site to the irrigation ditch, the change in use
should upgrade the site to provide for water quality measures.
11. This change of use request would be subject to the requirements as set forth in
the new LUC, the North college Avenue Corridor Plan, and the Standards and
Guidelines for the North College Avenue Corridor. Please contact Clark Mapes
of the Advance Planning Department, at 221-6225, to help determine what
standards apply to this request.
12. The PDP review process through the City could take 8 - 12 weeks to get to public
hearing for a decision, whether it is an administrative hearing or Planning and
Zoning Board hearing.
e. The property has never been platted as a legally subdivided lot and it
must be with the proposed change in use. The platting can be done as
part of the change in use request and PDP review.
Please contact Peter, at 221-6760, if you have questions about these comments.
5. Roger Buffington of the Water/Wastewater Department
a. It does not appear that there will be any water or sanitary sewer service
changes to the site with the proposed change in land use.
b. If there is a grease interceptor in the building (because of the previous
restaurant) it should be removed and the sanitary sewer service should be
redone for the proposed retail uses.
C. There is an existing sanitary sewer main along the north side of the Josh
Ames Ditch that must be maintained and a 30' wide utility easement must
be dedicated for the main.
d. It may not be necessary to submit new utility plans for review; however,
the existing utilities should be shown on the Site and/or Landscape Plan.
e. The City's water conservation standards will apply to the landscape
improvements on -site. A copy of the requirements is available in the
Water Department or the Current Planning Department.
Please contact Roger, at 221-6681, if you have questions about these
comments.
6. Glen Schlueter of the Stormwater Utility offered the following comments:
a. This site is located on the edge of the Dry Creek drainage basin and the
Poudre River drainage basin. The fee for the Dry Creek basin is $5,000
per acre and that is subject to the runoff coefficient reduction. The Poudre
River basin currently has no fees. Fees would be assessed only for
increases in imperviousness (hard surface areas such as streets, parking
lots, driveways, sidewalks, buildings, etc.) greater than 350 square feet in
size. The site is located within inventory grid #8F.
b. The existing imperviousness is grandfathered, so the primary issue is to
document and maintain surface drainage flow patterns. The standard
drainage and erosion control reports and plans are required to be
submitted for review. They must be prepared by a professional engineer
registered in the State of Colorado.
b. The building, being larger than 5,000 square feet in size, must be
compartmentalized or equipped with an automatic fire sprinkler system.
3. Michael Dean of the Engineering Department offered the following comments:
a. A Transportation Impact Analysis is required with your Project
Development Plan (PDP) submittal. Please contact Eric Bracke, at 221-
6062, to schedule a "scoping" meeting to discuss the information needed
in the analysis.
b. Additional street right-of-way may be needed along North college Avenue.
The total amount of ROW needed is 57.5' either side of centerline.
C. There may be street improvements along the North College Avenue
frontage that this property owner would be responsible for.
d. Street oversizing fees of $19,443 per acre will apply to this site and new
land use. You would be responsible for any outstanding fees that may not
have been paid by Dimmer's Brew Pub. The fees will be collected at the
time of issuance of building permits. Possible modifications to the fees are
going to City Council for review and approval sometime yet this year. If
approved, the new fees will be based on vehicle trip generations by the
development.
e. The standard utility plan requirements, if applicable for the proposed retail
uses, must be submitted to the City for review and approval.
Please contact Michael, at 221-6750, if you have questions about these
comments.
4. Peter Barnes of the Zoning Department offered the following comments:
a. The property is in the CN - North College Commercial Zoning District.
b. The building does not comply with the "build -to" line requirement in the
City's new Land Use Code (LUC); therefore, you will have to submit a
request for a modification to the standard and the change in use request
will have to go to the Planning and Zoning Board for a decision.
C. The new LUC allows a maximum of 4 parking spaces per 1,000 square
feet of floor space on -site for the proposed retail uses.
d. The on -site parking areas do not presently comply with the standards for
design and landscaping as set forth in the new LUC. They must be
brought into compliance with the proposed change in use.
CONCEPTUAL REVIEW STAFF COMMENTS
Citv of Fort Collins
MEETING DATE
ITEM:
APPLICANT:
LAND USE DATA:
December 1, 1997
742 - 746 North College Avenue
(Formerly Dimmer's Brew Pub)
Ted Zibell
The Perennial Gardener
154 North College Avenue
Fort Collins, CO. 80524
Request for a change of use from a restaurant/brew pub to [speculative] retail uses in
an existing 7,700 square foot building on a 0.83 acre (36,100 square foot) lot. This site
was most recently the Dimmer's Brew Pub. The property is located on the east side of
North College Avenue, north of East Vine Drive and directly north of the Josh Ames
Irrigation Ditch, and is in the CN - North College Commercial Zoning District.
COMMENTS:
1. Janet McTague of the Light & Power Department offered the following
comments:
a. It does not appear that there will be any electric service changes to the
site with the proposed change in land use.
b. There is an existing overhead electric line behind the building that the City
will be changing to underground in front of the building. This will be done
at no cost to the property owner.
C. Light & Power will need an empty conduits along the front of the property
and to the electric meter on the building.
Please contact Janet, at 221-6700, if you have questions about these comments.
2. Roger Frasco of the Poudre Fire Authority offered the following comments:
a. The previous restaurant business was probably an A-3 rated use and the
proposed new retail use would be a B-2 rated use.
COMMUNITY PLANNING AND ENVIRONMENTAL SERVICES 281 N. College Ave. P.O. Boa 580 Fort Collins, CO 80522-0580 (970) 221-6750
PLANNING DEPARTMENT
Commu- "y Planning and Environmental ~vices
Current Planning
City of Fort Collins
December 10, 1997
Ted Zibell
The Perennial Gardener
154 North College Avenue
Fort Collins, CO. 80524
Dear Ted,
For your information, attached is a copy of the Staffs comments concerning the request
for 742 - 746 North College Avenue (Formerly Dimmer's Brew Pub), which was
presented before the Conceptual Review Team on December 1, 1997.
This is a request for a change of use from a restaurant/brew pub to [speculative] retail
uses in an existing 7,700 square foot building on a 0.83 acre (36,100 square foot) lot.
This site was most recently the Dimmer's Brew Pub. The property is located on the east
side of North College Avenue, north of East Vine Drive and directly north of the Josh
Ames Irrigation Ditch, and is in the CN - North College Commercial Zoning District.
The comments are offered informally by Staff to assist you in preparing the detailed
components of the project application. Modifications and additions to these comments
may be made at the time of formal review of this project.
If you should have any questions regarding these comments or the next steps in the
review process, please feel free to call me at 221-6750.
Sincerely,
eve Olt
Project Planner
xc: Stormwater Utility/Glen Schlueter
Streets/Eric Bracke
Clark Mapes
Peter Barnes
Larry Stroud
File
281 North College Avenue • P.O. Box 580 • Fort Collins, CO 80522-0580 • (970) 221-6750 • FAX (970) 416-2020
6. Stormwater Utility:
a. The submitted Landscaping plan does not increase imperviousness by
more than 350 square feet, and therefore the Dry Creek basin fee of
$5,000 per acre does not apply.
b. The standard drainage and erosion control reports have been submitted
for PDP review. Due to the limitations of the site, the current drainage
flow patterns have been generally maintained as part of the landscaping
plan.
c. An easement has been established for the pipe or box culvert for the Josh
Ames Ditch which is under the parking lot South of the existing
building. The easement is shown on the plat showing the property as a
legally subdivided lot.
d. All plans have been corrected to show the ditch with the existing bridge
on North College as Lake Canal.
e. The relatively flat nature of the property, combined with the location of
Lake Canal, limits the water quality measures that can be incorporated.
f. No new structures are planned and the existing structure's improvements
will be less than 50% of its value. as a result, flood plane requirements
do not apply to this project.
7. The Transportation Impact Study and the Multi -Modal Level of Service
Study requirements outlined by Kathleen Reavis have been completed and
submitted for PDP review.
8. The proposed landscaping plan does not create any obstructions which
would prohibit the creation of a bus stop along North College Avenue in the
future.
9. A trash collection and recycling enclosure is planned for the North-East
corner of the building, as shown on the Site/Landscaping Plan.
10. See water quality comments under 6e.
1 1. The plan presented for PDP review has been created utilizing suggestions
by Clark Mapes of the Advance Planning Department. Every effort was
made to comply with the concepts presented in the North College Avenue
Corridor Plan, as well as comply with the Standard and Guidelines of the
North College Avenue Corridor and the requirements of the LUC.
12. Any effort by the City to shorten the review process would be greatly
appreciated.
d. No potential street oversizing fees or potential outstanding fees were
found to apply to this project.
e. No change is planned to the existing utilities. The Utility, Drainage and
Erosion Control Report prepared by Shear Engineering shows the
location of the existing utilities.
4. Zoning Department:
a. The property is in CN - North College Commercial Zoning District
b. The building was found to comply to the Building Placement - Setback
from North College Avenue standard as stated in the Standards and
Guidelines for the North College Avenue Corridor. This standard
supersedes the "build -to" line requirement in the City's new Land Use
Code (LUC). Therefore there is no need to submit a request for a
modification to the LUC standard, nor go the Planning and Zoning
Board for a decision.
c. The building has over 7700 square feet of floor space, which allows for
a maximum of 30 parking spaces. The landscaping plan shows 20
parking spaces which is less than the maximum allowed.
d. The Site/Landscaping Plan presented for PDP review is consistent with
the standards for design presented in the Standards and Guidelines for
the North College Avenue Corridor and the LUC.
e. A plat showing the property as a legally subdivided lot has been
submitted for PDP review.
5. Water/Wastewater Department:
a. There will be no water or sanitary sewer service changes to the site,
therefore no action is required by the property owner.
b. There is no grease interceptor in the building.
c. A 30 foot wide utility easement has been dedicated for the existing
sanitary sewer main along the north side of the Josh Ames Ditch.
d. The existing utilities have been shown on the Site/Landscaping Plan.
e. The landscaping plan incorporates the City's Landscaping Standards for
Water Conservation and the City's Irrigation System Standards for
Water Conservation. All proposed plants require either moderate or low
water use.
March 31, 1998
PDP Review Document
Current Planning Department
City of Fort Collins
281 N. College Avenue
Fort Collins, CO 80524
RE: 742-746 N. College Avenue
Project Development Plan
Review of Conceptual Letter Issues
This document discuses how the specific issues outlined in the project's
Conceptual Review letter dated December 10, 1997 have been addressed.
1. Light & Power Department:
a. No electric service changes are planned for the site, therefore no action is
required by the property owner.
b. No action is currently required concerning the existing overhead electric
line behind the building.
c. Sufficient notice will be given to the City so they can install an empty
conduit along the front of the property and to the electric meter on the
building. Janet McTague stated that the property owner will not incur
any of the costs of installation.
2. Poudre Fire Authority:
a. No action is required by the property owner concerning the change in
rated use from an A-3 to a B-2.
b. The building will be compartmentalized utilizing a fire wall, as shown in
Attachment A, such that no space shall be larger than 5000 square feet.
3. EnOneerino Department:
a. The Transportation Impact Analysis requirements outlined by Eric
Bracke, City Traffic Engineer have been completed and submitted for
PDP review.
b. A total street right of way along North College Avenue has been
established at 57.5 feet from the center line. The ROW is shown on the
plat showing the property as a legally subdivided lot which has been
submitted for PDP review.
c. All identified improvements along the North College Avenue frontage are
presented on the Site/Landscaping Plan submitted for PDP review.