Loading...
HomeMy WebLinkAboutFORT COLLINS LOVELAND WATER DISTRICT - PDP - 23-98 - SUBMITTAL DOCUMENTS - ROUND 1 - DRAINAGE REPORTst 0. �� iYy� Ct' Ct io.nw rt K•n a •� U i L 3g ero� ROAD clw. n o� F A Kam. a v' w A " u+ or r°E.. � � a U v oe• r NOr 1p se.�.a• WY � NppY mmsm �n a � ••'� :`r d � T a d • 9j C CI 4 ct "p. In <r ,y 5non SI y Cwrl bl ywgri°pt � Emr d �'•••., amNieE. d Nay •_> PORTNER Ay.°v a y Ayar a Cr VICINITY MAP APPROXIMATE SCALE: 1" = 2000' H APPENDIX A MAPS AND FIGURES 6.0 REFERENCES 1 2. 3 4 n City of Fort Collins, "Storm Drainage Design Criteria and Construction Standards," (SDDCCS), dated May 1984. Urban Drainage and Flood Control District, "Urban Storm Drainage Criteria Manual", Volumes 1 and 2, dated March 1969, and Volume 3 dated September 1992. Master Drainageway Planning Study for the Fossil Creek Drainage Basin by Simons, Li & Associates dated August 1982. Final Drainage Report for the Fossil Creek Design Center, P.U.D. by Stewart & Associates, Inc. dated May 16, 1989. 0 XA9097.03\drrpt\drainrpt Page 8 1 and soil stockpiles not otherwise permanently stabilized. Vegetation shall not be considered until a ground cover is achieved which is demonstrated to be mature enough to control soil erosion to the satisfaction of the City and to survive severe weather conditions. Erosion control calculations, cost estimate, and schedule is included in the appendix of this report. 1 1 T X A9097.03\drrpt\drainrpt Page 7 I I 1 1 .1 1 1 1 t Rainfall Wind Soil Designation Erodibility Zone Erodibility Zone Altvan-Santata Loams Moderate Moderate 5.3 . Erosion and Sediment Control Measures Erosion and Sedimentation will be controlled on -site by the use of silt fence, construction entrances and overexcavation of the detention ponds during construction to act as sediment traps. 5.4 Dust Abatement During the performance of the work or any operations appurtenant thereto, the Contractor shall -carry out proper efficient measures wherever and as necessary to prevent or reduce dust nuisance, and to prevent dust which has originatedfrom his operations from damaging crops, orchards, cultivated fields, and dwellings, or causing a nuisance to persons. The Contractor will be responsible for any damage resulting from dust originating from his operations. 5.5 Tracking Mud on City Streets Wherever construction vehicles access routes or intersect paved public roads, provisions must be made to minimize the transport of sediment (mud) by runoff or vehicles tracking onto the paved surface. Stabilized construction entrances are required per the detail shown on the Plan, with base material consisting ofb" coarse aggregate. The contractor will be responsible for clearing mud tracked onto city streets on a daily basis. 5.6 Maintenance All temporary and permanent erosion and sediment control practices must be maintained and repaired as needed to assure continued performance of their needed function. Maintenance is the responsibility of the contractor. 5.7 Permanent Stabilization A vegetative cover shall be established within one and one-half years on disturbed areas XA9097.03\drrpt\drainrpt Page 6 1 4. DESIGN AREA AREA C10 C10o Tc (10) Tc (100) Q(10), Q (100) POINT DESIG. (ACRES) (MIN) MIN) (CFS) (CFS) 1 1 3.17 0.40 0.50 9.3 8.4 6.73 13.99 2 2 0.71 0.57 0.71 6.8 5.5 2.07 4.41 3 0.17 0.88 1.0 5.0 5.0 0.86 1.56 4 0.59 0.27 0.34 10.8 10.8 0.70 1.39 RUNOFF DETENTION AND RELEASE ' The site will contain two detention ponds, detention pond 1 is located at the southwest corner of Tractt C and detention pond 2 is located in Lot 1. Both ponds are designed to detain runoff from the 100-year storm from the site. Detention Pond 1 will release into detention pond ?. at agate of °1 A cfs and will -be controlled by 5.2" diameter orifice plate. Detention Vond 2 will release into the existing storm system in Snead Drive at a rate of 1.5 cfs and will be controlled by a 6.4" diameter orifice plate. Calculations are included in the appendix of this report. 5. EROSION CONTROL 5.1 Introduction This section represents the Erosion Control Report for Fort Collins -Loveland Water District and was prepared to meet the regulatory requirements of the City of Fort Collins. This report was prepared following the guidelines and regulations set forth in the SDDCCS Manual. The proposed improvements cover all of Lot 1 and grading will be completed in Tract C. 1 No grading or improvements are proposed on Tracts A or B. The general topography of this site consists of undisturbed soil with native vegetative ground ' cover. Slopes range from three to ten percent. ' 5.2 Soil Description ' In accordance with the Soil Conservation Service's {SCS) "Soil Survey of Fort Collins Area, Colorado," the soils on -site consist of the following: XA909 7.03\drrpt\drainrpt Page 5 1 1 3.4 Hydrologic Analysis of the Proposed Drainage Conditions The Rational Method was used to determine both 10-year and 100-year peak runoff values for -each Sub -basin. Runoff coefficients were assigned utilizing Table 3-2 of the SDDCCS Manual. As stated above, the Rational Method was used for all hydrologic analyses for the project site. The Rational Method utilizes the equation: Q=CfCIA (1) where Q is the flow in cfs, C is the runoff coefficient, Cf is the storm frequency adjustment factor, I is the rainfall intensity in inches per hour, and A is the total area of the basin in acres. The frequency adjustment factor, Cf is 1.0 for the initial 10-year storm and 1.25 for the major 100-year storm. The appropriate rainfall intensity information was developed based on rainfall intensity - duration curves in Figure 3-1 of this Manual. In order -to utilize the rainfall intensity -curves, the time of concentration is required. The following equation was used to determine the time of -concentration: t'=ta+tt (2) where t, is the time of concentration in minutes, to is the initial or overland flow time in minutes, and t, is the travel time in the ditch,channel, or gutter in minutes. The initial or overland- low time is calculated with the equation: to = [1.87(1.1- CCf)Lo.5J/(S)0.33 (3) where L is the length of overland flow in feet {limited to a maximum of 500 feet), S is the average slope of the basin in percent, and C and Cf ar-e as defined previously. All hydrologic calculations associated with the sub -basins shown are attached in the Appendix of this report. Table 3.1 provides a summary of the design flows for all Subbasins and Design Points (DP's) associated with this site. XA9097.03\drrpt\drainrpt Page 4 1 the site through an existing irrigation lateral. This flow is diverted to the east property line and is not conveyed through proposed detention facilities. 3.3 Onsite Flows Approximately 2 acres of this 5-acre site has been rezoned to allow for the development of the FCLWD building and the remainder of the site will remain undeveloped. Drainage within the developed area will surface flow to detention ponds with the exception of two basins, which will direct discharge. All grading has been designed to carry flows in a positive direction away from structures to the proposed drainage facilities. A qualitative summary of the drainage patterns within each developed sub -basin is provided in the following paragraphs. Detention and -release rates are described in Section 4, "Runoff Detention and Release". Sub -basin 1 is approximately 3.7 acres and contains a portion of the east half of Snead Drive. .. the FCL WD building and the storage yard. Runoff from Sub -basin 1 is conveyed by surface flow to Detention Pond #1 at the southeast comer of Tract C. Release from this detention pond flows into Detention Pond 42 and is restricted to 1.0 cfs by an orifice plate. Sub -basin 2 contains the drop off lane, the parking lot on the south of -the building and the green area between Snead Drive and the drop off lane. Sub -basin 2 contains approximately 0.7 acres and runoff from this sub -basin is carried overland to detention pond #2. Detention pond #2 also receives discharge from detention pond #1 and releases to the inlet and storm system in Snead Drive. The discharge from this pond is limited to 1.5 cfs by an orifice plate. Sub -basin 3 is a small basin along the west property line and contains approximately 0.17 acres. This sub -basin contains the east half of Snead Drive that is released downstream undetained. Sub -basin 4 is along the south property line of the site and is primarily maintained as native grasses. This basin will release downstream undetained as it has historically done. The amount of runoff released downstream will be dramatically reduced because of the on site detention. A perforated pipe will also be installed along the south property line in an attempt to alleviate downstream concerns and to help mitigate groundwater issues downstream. XA9097.03\drtpt\drainrpt Page 3 2. 3. 1.5 Master Drainage Basin This site is located in the Fossil Creek Master Drainage Basin. The Master Drainageway Planning Study forthe Fossil Creek Drainage Basin prepared by Simons, Li & Associates, Inc. dated August 1982 does not require on -site storm water detention for this -site. On -site detention will be provided for this site to lower the discharge from the site and improve downstream conditions. EXISTING DRAINAGE SYSTEM Fossil Creek Design Center installed a storm system in Snead Drive that will be utilized for the detention discharge from this site. An inlet on the west side of Snead Drive collects flows from the Fossil Creek Design Center from a 15" pipe and also collects flows from Snead Drive. These flows are discharged to a swale to the south through a 27" pipe. The Swale carries flows south to a 30" pipe under Fossil Creek Parkway and into Fossil Creek. Detention discharge from the FCLWD site will be routed via pipe to the existing inlet in Snead Drive and then south in the existing swaleto the pipe under Fossil Creek Parkway. Our research and field survey determined that the pipe under Fossil Creek Parkway was installed approximately 3 feet too high and the slope is flatter that was designed. This construction error has reduced the capacity of this pipe. The pipe will have the capacity to convey flows from the FCLWD site with this development but with any future development east or west of Snead Drive, this pipe will require upsizing or an additional pipe will need to be installed under Fossil Creek Parkway. DEVELOPED FLOWS 3.1 Criteria The Rational Method was used to determine both the 10-year and 100-year flows for the sub - basins indicated in this drainage report. A description of the hydrologic analysis is provided in Section 3.6 of this report. 3.2 Off -site Flows A portion of the east half of Snead Drive will be routed through this site and into the proposed detention area. Offsite flows from the property to the north will continue to be routed through X:\9097.03\dtrpt\drainrpt Page 2 1. INTRODUCTION ' 1.1 Project Location The proposed Fort Collins -Loveland Water District (FCLWD) building is located adjacent to the east side of Snead Drive, north of Fossil Creek Parkway and south of Fairway Lane. The site location can also be described as a portion of the Southwest Quarter of Section 1, Township 6 North, Range 69 West of the Sixth Principal Meridian, City of Fort Collins, County of Larimer, State of Colorado. The site is approximately 5 acres, and is bounded on the north, east and south by residential developments and on the west by Snead Drive and the Fossil Creek Design Center. (See FIGURE 1 - VICINITY MAP.) 1.2 Site Characteristics The general topography of the site consists :primarily of undisturbed soil with native vegetation. In general the site slopes to the southeast at slopes varying from 3 to 10 percent. The Soil Survey of Larimer County Area, Colorado indicates the soils for this site are comprised of Altvan-Santanta loams which have the potential for moderate wind and water erosion. 1.3 Purpose and Scope of Report This report defines the proposed drainage and erosion control plan for the proposed Fort Collins -Loveland Water District, including consideration of all on -site and off -site runoff. 1.4 Design Criteria This report was prepared to meet or exceed the submittal requirements established in the City of Fort Collins' "Storm Drainage Design Criteria and Construction Standards" (SDDCCS), dated May 1984. Runoff computations were prepared for the 10-year and 100-year storm frequency utilizing the rational method. Where applicable, the criteria established in the "Urban Storm Drainage Criteria Manual" (UDFCD), 1984, developed by the Denver regional Council of Governments, has been utilized. XA9097.03\drrpt\drainrpt Page I TABLE OF CONTENT'S TABLE OF CONTENTS 2. INTRODUCTION PAGE 1.1 Project Location..............................................................................1 1.2 Site Characteristics..........................................................................1 1.3 Purpose and Scope of Report ..............................................................1 1.4 Design Criteria..............................................................................1 1.5 Master Drainage Basin...................................................................................2 EXISTING DRAINAGE SYSTEM ...... :.....................................................................2 3. DEVELOPED FLOWS 3.1 Criteria..............................................................................................:..................:...2 3.2 Off -Site Flows..........................................................................................................2 3.3 Onsite Flows...........................................................................................................3 3.4 , Hydrologic Analysis of the Proposed Drainage Conditions....................................4 ' 4. RUNOFF DETENTION AND RELEASE.......................................................5 5. EROSION CONTROL ..............................................................................5 5.1 Introduction..............................................................................................................5 5.2 Soil Description.......................................:...............................................................5 5.3 Erosion and Sediment Control Measures................................................................6 5.4 _Dust Abatement.......................................................................................................6 5.5 Tracking Mud on City Streets ...................... :........................................................... 6 5.6 Maintenance .............................................................................................................6 5.7 Permanent Stabilization ................... ......................................................................... 6 6. REFERENCES....................................................................:..................8 APPENDIX A MAPS AND FIGURES APPENDIX B HYDROLOGIC CALCULATIONS APPENDIX C DETENTION POND CALCULATIONS APPENDIX D ORIFICE PLATE CALCULATIONS APPENDIX E EROSION CONTROL CALCULATIONS APPENDIX F FOSSIL CREEK DESIGN CENTER DRAINAGE REPORT No Text FINAL DRAINAGE AND EROSION CONTROL STUDY FOR FORT COLLINS-LOVELAND WATER DISTRICT Prepared for: FORT COLLINS-LOVELAND WATER 17ISTRICT 47,00 South College Avenue Fort Collins, CO 80525 970-226-3104 Prepared by: JR Engineering, Ltd. 2620 East Prospect Road, Suite 190 Fort Collins, Colorado 80525 (970) 491-9888 April 21, 1998 Job Number 9097.03 FINAL DRAINAGE AND EROSION CONTROL STUDY FOR FORT COLLINS-LOVELAND WATER DISTRICT Engineering, Ltd,