Loading...
HomeMy WebLinkAboutCIVIC CENTER PARKING STRUCTURE - FDP - 35-98A - SUBMITTAL DOCUMENTS - ROUND 1 - REVISIONSLam@@Fi� urban design, inc. With these comments addressed, and the approval of the PDP by the Planning and Zoning Board at their December 17, 1998, hearing, please review these plans for final compliance. Please do not hesitate to contact me if additional information or materials is required. Sincerely, Kimberly St ICP Cityscape Urban Design, Inc. Copy to: Jack Gianola, City Facilities Department Allan Bliesmer, Hensel Phelps Construction Brian Chaffee, Fentress Bradburn Architects Alexa Taylor, Fentress Bradburn Architects Rod van Uffelen, Parsons Terence Hoaglund, Vignette Studios Ron Estes, Merit Electric tAn@@P@ urban design, inc. C6 of 9 • Utilities are shown in plan view and utility crossings are illustrated in profile view where appropriate. All existing and proposed improvements in the right-of-way are shown. • Sheet numbers have been referenced as requested. The stormwater profile sheet has been referenced as requested. Stormwater utilities are shown in plan view, with crossings in profile view. As per discussion and meeting with Mark McCallum, stationing as indicated in the plans is acceptable. All grade breaks are now shown. Sheet C7 of 9: • Utilities are shown in plan view and utility crossings are illustrated in profile view where appropriate. All existing and proposed improvements in the right-of-way are shown. • Sheet numbers have been referenced as requested. • The stormwater profile sheet has been referenced as requested. Stormwater utilities are shown in plan view, with crossings in profile view. • As per discussion and meeting with Mark McCallum, stationing as indicated in the plans is acceptable. All grade breaks are now shown. 6. Stormwater Utility • Red -lined plan comments have been incorporated where necessary as requested. • Drainage report will follow, per conversation with Basil Hamden and Steve Olt. Comments will be addressed at that time. Water/Wastewater • The gas main is located in the street per PSCo., the previous location was incorrect. • The grease/oil interceptor has been added. • All water/sewer mains and services are shown on the landscape plans. Staff Review Meeting Comments 7. As indicated on the plans, the southern crosswalk, across Mason, will be constructed with this project. As there are pending projects on each of the four corners of this intersection, it seems reasonable that each project be responsible for one of the enhanced crosswalks and accompanying improvements. The three remaining crosswalks are labeled as, "Future... not a part of this project," on the site plan. 8. All necessary permits, including those for any encroachment into the right-of-way, will be obtained at the appropriate time. 2 0�y7p@p@ urban design, inc. December 22, 1998 Steve Olt Project Planner Current Planning Department City of Fort Collins 281 North College Avenue Fort Collins, CO 80524 RE: Civic Center Parking Structure — Responses to Staff Comments Dear Steve, 3555 stanford road, suite 105 fort collins, colorado 80525 (970) 226-4074 FAX (970) 226-4196 E-mail: cityscap@frii.com Please find enclosed the FDP submittal for the Civic Center Parking Structure, per city requirements. These plans have been revised from the PDP per the Staff Comments dated November 19, 1998. The following changes are made to the plans as follows: Specific Department Comments 2. Zoning Department a. Signage on the building elevations will be crossed off and is not to be reviewed at this time. b. All fixtures are down -directional with cut-offs, except for decorative building uplighting and wall packs on the south alley. 3. Traffic Operations Department The proposed median extension in LaPorte has been removed. 4. Light and Power Department a. This comment is acknowledged. b. The proposed location of the transformer is shown in plan view and elevations. A copy of these plans and elevations has been forwarded to Bruce Vogel, already. 5. Engineering Department Red -lined plan comments have been incorporated where necessary, as requested. Utility Plan Comments C3 of 9 Enhanced crosswalks have been labeled as requested. Please see revised plans. The median extension has been removed. The median extension has been removed.