Loading...
HomeMy WebLinkAboutBOARDWALK CROSSING @ MASON STREET - PDP/FDP - FDP130003 - CORRESPONDENCE - (8)Topic: Traffic Impact Study Comment Number: 3 Comment Originated: 03/21/2013 TIS accepted. Department: Traffic Operation Contact: Ward Stanford, 970-221-6820, wstanford(a7fcgov.com Topic: Traffic Impact Study Department: Water -Wastewater Engineering Contact: Roger Buffington, 970-221-6854, rbuffington(a)-fcgov.com Topic: Construction Drawings Comment Number: 1 Comment Originated: 03/12/2013 03/12/2013: On Boardwalk, is there a conflict between the storm drain and the fire line? Will a lowering be needed on the fire line? Comment Number: 2 Comment Originated: 03/12/2013 03/12/2013: PVC can be used for fire lines. If used, tracer wire is required, and the Standard Details for tracer wire (30) and locator stations (25) need to be included. Comment Number: 3 Comment Originated: 03/22/2013 03/22/2013: The utility standard details are out of date. Please provide an email address, and the current details will be provided. Department: Zoning Contact: Noah Beals, 970.416.2313, nbealsDfcgov.com Topic: General Comment Number: 2 Comment Originated: 03/19/2013 03/19/2013: In addition to the required modification request stated by Current Planning an additional modification would be needed for the East side of drive aisle along the east property line LUC 3.2.2(J) requires a 5ft landscape area between vehicle use areas and lot line. 03/21/2013: The boundary and legal description close. Department: Technical Services Contact: Jeff County, 970-221.6588, jcountv(a)fcaov.com Topic: Plat Comment Number: 5 Comment Originated: 03/21/2013 05/01/2013: There are still some bearings & distances that need to be added to locate some easements. 03/21/2013: All easements (existing or proposed) must be shown with enough bearing & distance or curve information to establish their position. Comment Number: 10 Comment Originated: 03/21/2013 05/01/2013: It would be preferable to have a light gray solid hatching to differentiate from the other angled line hatching. 03/21/2013: You may want to hatch access and/or drainage easements for clarity. Comment Number: 16 Comment Originated: 03/21/2013 05/01/2013: These are now Notes 5-7, and have not been addressed. Please remove. 03/21/2013: Notes 7-9 appear to be ALTA or Land Survey Plat notes. Please remove. Comment Number: 29 Comment Originated: 05/01/2013 05/01/2013: There are line over text issues. Comment Number: 30 Comment Originated: 05/01/2013 05/01/2013: Please label the easement lines at the northwest corner of Lot 2. Add an enlarged detail if need, to illustrate this. Topic: Site Plan Comment Number: 18 Comment Originated: 03/21/2013 05/01/2013: There is a "2" missing. See redlines. 03/21/2013: The legal description does not match the Subdivision Plat. Please change to match. Comment Number: 19 Comment Originated: 03/21/2013 05/01/2013: There are still line over text issues. 03/21/2013: There are line over text issues on sheet 1. Department: Traffic Operation Contact: Ward Stanford, 970-221-6820, wstanford fcgov.com Topic: Construction Drawings Comment Number: 1 Comment Originated: 03/18/2013 03/18/2013: The S&S Notes (and any other on other sheets if applicable) need to be revised to state the "City Traffic Engineer" at each instance where the notes state "Local Entity" engineer. The Signing and Striping installation is overseen by the City TE (or designate) versus the City Engineer (or designate). Comment Number: 2 Comment Originated: 03/18/2013 03/18/2013: Please verify the City's corner sight distance criteria is met at the Mason intersections. Department: PFA Contact: Jim Lynxwiler, 970.416.2869, ilynxwiler(a)aoudre-f1re.org Topic: General Comment Number: 01 Comment Originated: 03/20/2013 03/20/2013: FIRE LANES Fire Lanes shall be designated on the plat as "Emergency Access Easement, not "access easement' or "vehicular access easement'. Department: Stormwater Engineering Contact: Jesse Schlam, 970-218.2932, ischlam cDfcgov.com Topic: Erosion Control Comment Number: 3 Comment Originated: 05/01/2013 05/01/2013: Please replace all strawbale related sediment controls with an effective BMP. If you need clarification concerning this section, or if there are any questions please contact Jesse Schlam 970-218-2932 or email @ jschlam@fcgov.com Contact: Wes Lamarque, 970-416-2418, wlamargue(a)fcuov.com Topic: General Comment Number: 2 Comment Originated: 03/15/2013 04/30/2013: 03/15/2013: Minor comments may apply at final compliance. Department: Technical Services Contact: Jeff County, 970.221-6588, icountycDfc4ov.com Topic: Construction Drawings Comment Number: 24 Comment Originated: 03/21/2013 05/01/2013: The number is corrected, but the description is still wrong. This benchmark is not an "X". It is a brass disk. There is also a mispelled word, "culvert". 03/21/2013: Please correct the number and description of benchmark E-322 on all sheets it is shown on. This description does not match the NGS description that is published. Comment Number: 26 Comment Originated: 03/21/2013 05/01/2013: This is still an issue on sheet C4. 03/21/2013: Please move the street names and data into the right of way on sheets C3 & C4. Comment Number: 27 Comment Originated: 03/21/2013 05/01/2013: There are still line over text issues on sheet C4. 03/21/2013: There are line over text issues on sheet C4. Topic: Landscape Plans Comment Number: 21 Comment Originated: 03/21/2013 05/01/2013: There are still line over text issues. 03/21/2013: There are line over text issues on sheet 2. Topic: Plat Comment Number: 1 Comment Originated: 03/21/2013 Department: Engineering Development Review Contact: Tyler Siegmund, 970-221-6501, tsiegmund(a)fcgov.com Topic: Plat Comment Number: 1 Comment Originated: 03/22/2013 05/01/2013: A few of the easement boundaries on the plat are still confusing. It is recommended that you shade the drainage easements light Grey and remove the hatching (for the drainage easements only). See redlines. 03/2212013: The easements shown on the plat are very confusing to follow and to determine the limits of each easement. Please clearly identify the limits of each easement shown on the plat. Department: Forestry Contact: Tim Buchanan, 970.221.6361, Topic: Landscape Plans Comment Number: 5 05/02/2013: tbuchananOfcgov.com Please replace planting note #11 with the following: Comment Originated: 05/02/2013 A permit must be obtained from the City forester before any trees or shrubs as noted on this plan are planted, pruned or removed on the public right-of-way. This includes zones between the sidewalk and curb, medians and other city property. This permit shall approve the location and species to be planted. Failure to obtain this permit may result in replacing or relocating trees and a hold on certificate of occupancy. Please add the following statement as an additional Planting Note: The developer shall contact the City Forester to inspect all street tree plantings at the completion of each phase of the development. All trees need to have been installed as shown on the landscape plan. Approval of street tree planting is required before final approval of each phase. Failure to obtain approval by the City Forester for street trees in a phase shall result in a hold on certificate of occupancy for future phases of the development. Department: Light And Power Contact: Doug Martine, 970-224.6152, dmartine(a)fcgov.com Topic: General Comment Number: 1 Comment Originated: 03/06/2013 03/06/2013: The developer will need to coordinate power requirements and electric development charges with Light & Power Engineering at (970)221-6700. Comment Number: 2 Comment Originated: 03/06/2013 03/06/2013: After the plans are final, an Autocad drawing (version 2008) of the site plan will need to be sent to Terry Cox at TCOX@FCGOV.COM. Topic: Landscape Plans Comment Number: 16 Comment Originated: 04/29/2013 04/29/2013: Change Sheet title on top and lower right corner to say Project Development Plan and Final Development Plan - not "Preliminary" (typ. all sheets). Department: Current Planning Contact: Pete Wray, 970.221.6754, pwray@fcgov.com Topic: Landscape Plans Comment Number: 17 Comment Originated: 04/29/2013 04/29/2013: Change scale in Hydrozone Plan from 1=30', to 1 "=60% or NTC. Comment Number: 24 Comment Originated: 05/03/2013 05/03/2013: Change 4 shrubs in the strip along the west edge of parking: change 4 Cotoneaester dammed to 4 Syringa meyeri. Topic: Site Plan Comment Number: 22 Comment Originated: 04/29/2013 04/29/2013: Change both sheet titles to match others. Comment Number: 23 Comment Originated: 04/29/2013 04/29/2013: Clarify end of curb/gutter at north west comer of Building Three near transformer. It extends past parking edge. Contact: Sherry Albertson -Clark, 970.224-6174, salbertson-clark(a)_fcgov.com Topic: General Comment Number: 1 Comment Originated: 03/11/2013 This project was submitted as a combined PDP and FP, which should be noted on the site and landscape plans and architectural elevations. Department: Engineering Development Review Contact: Sheri Langenberger, 970.221-6573, slannenberger(6)fcgov.com Topic: General Comment Number: 11 Comment Originated: 03/28/2013 03/28/2013: The project owes an additional $146.04 for TDRF. The fee submittal did not account for the total area being replated. Contact: Tyler Siegmund, 970-221-6501, tsiegmund(a)fcgov.com Topic: General Comment Number: 12 Comment Originated: 05/01/2013 05/01/2013: Please add a note to the overall utility plan (sheet C3) the specifies the handicap ramp openings match the width of the sidewalk, or 6ft wide handicap ramp openings to match the width of the sidewalk. Comment Number: 13 Comment Originated: 05/01/2013 05/01/2013: Please remove the copy of the plat from the utility plan set prior to printing Mylars. The plat will be filed separately. Topic: Plat - of ' Fort Collins Community Development and Neighborhood Services 281 North College Avenue PO Box 580 Fort Collins, CO 80522 970.221.6750 970.224.6134 - fax kgov. com/de velopmentre view May 07, 2013 Steve Steinbicker Architecture West, LLC 4710 S. College Ave. Fort Collins, CO 80525 RE: Boardwalk Crossing at Mason Street, FDP130003, Round Number 2 Please see the following summary of comments from City staff and outside reviewing agencies for your submittal of the above referenced project. If you have questions about any comments, you may contact the individual commenter or direct your questions through the Project Planner, Pete Wray, at 970-221-6754 or pwray@fcgov.com. Comment Summary: Department: Current Planning Contact: Pete Wray, 970.221-6754, pwravlcilfcgov.com Topic: Building Elevations Comment Number: 20 Comment Originated: 04/29/2013 04/29/2013: Legend: Add title "Building Materials Legend" and add materials boxes on left side of legend and fill with corresponding material symbol to match elevation call outs. Comment Number: 21 Comment Originated: 04/29/2013 04/29/2013: Change sheet title to match other sheets on lower right corner and on top. Topic: General Comment Number: 18 Comment Originated: 04/29/2013 04/29/2013: In 5' planting beds between parking and Mason Street there is not enough room to show staggering of tree and shrub planting locations. tighten up the stagger to show more linear groupings, and move Malus Red Baron locations more closer to east edge, to minimize overhang on Mason sidewalk. this is also same comment for narrow planting strips in from of Building 2 and 3. Comment Number: 19 Comment Originated: 04/29/2013 04/29/2013: Site Photometric Plan - change title from "preliminary" to "Project" development plan.