HomeMy WebLinkAboutRIVERSIDE SELF-STORAGE - PDP/FDP - FDP140026 - CORRESPONDENCE - (5)Department: Water -Wastewater Engineering
Contact: Dan Mogen, , dmogen fcgov.com
Topic: General
Comment Number: 4 Comment Originated: 04/17/2015
04/17/2015: Sewer service is stubbed out to the NE -70' from the manhole and
comes into the manhole at a depth of -8-10'.
01/05/2015: Please correct the curve data as marked. See redlines.
11/03/2014: Please add distances as marked. See redlines.
Comment Number: 21 Comment Originated: 11/10/2014
04/14/2015: This has not been corrected.
01/05/2015: Please make this text smaller.
11110/2014: Please label the tie for the Fire Access Easement as a tie. See
redlines.
Comment Number: 31
Comment Originated: 04/14/2015
04/14/2015: Is the chiseled X found or set? this does not meet requirement
35-51-105(6). See redlines.
Topic: Site Plan
Comment Number: 24
Comment Originated: 11/10/2014
04/13/2015: This has been addressed.
01/05/2015: The legal description is still incorrect. Please change to match
redlines.
11/10/2014: Please change the title to match the Subdivision Plat. The plat title
will be changing.
Comment Number: 25 Comment Originated: 11/10/2014
04/13/2015: There are still line over text issues. See redlines.
01/05/2015: There are still line over text issues. See redlines.
11/10/2014: There are line over text issues. See redlines.
Comment Number: 26 Comment Originated: 11/10/2014
04/13/2015: There are still text over text issues. See redlines.
11/10/2014: There are text over text issues. See redlines.
Department: Traffic Operation
Contact: Martina Wilkinson, 970-221-6887, mwilkinson(a)fcgov.com
Topic: General
Comment Number: 2
01/06/2015: no further comments
Department: Water Conservation
Contact: Eric Olson, 970.221-6704, eolson(a)fcgov.com
Topic: Landscape Plans
Comment Number: 1
Comment Originated: 01/06/2015
Comment Originated: 10/31/2014
10/31/2014: Irrigation plans are required no later than at the time of building
permit. The irrigation plans must comply with the provisions outlined in Section
3.2.1(J) of the Land Use Code. Direct questions concerning irrigation
requirements to Eric Olson, at 221-6704 or eolson@fcgov.com
Comment Number: 2
Comment Originated: 12/30/2014
12/30/2014: A landscape plan must contain accurate and identification
hydrozones, including a water budget chart that shows the total annual water
use, which shall not exceed fifteen (15) gallons per square foot over the site. If
you have questions contact Eric Olson at eolson@fcgov.com or 970-221-6704.
01/05/2015: The elevation for benchmark 17-92 is incorrect, and benchmark
E357 is no longer part of the City of Fort Collins Vertical Control Network.
Please make sure you are using the most current information for the City's
Vertical Control Network. This information should be obtained from the
Surveying Department or technical Services
Comment Number: 29
Comment Originated: 04/13/2015
04/13/2015: The lighter text & linework marked is not acceptable. It will not
scan or reproduce. Please darken it up. See redlines.
Comment Number: 30 Comment Originated: 04/13/2015
04/13/2015: There is text that needs to be masked. Mask all text in hatched
areas. See redlines.
Topic: Landscape Plans
Comment Number: 8 Comment Originated: 11/03/2014
04/13/2015: There are still line over text issues. See redlines.
11/03/2014: There are line over text issues. See redlines.
Comment Number: 9 Comment Originated: 11/03/2014
04/13/2015: There is text that needs to be masked. Mask all text in hatched
areas. See redlines.
11/03/2014: Mask all text in hatched areas. See redlines.
Topic: Lighting Plan
Comment Number: 10 Comment Originated: 11/03/2014
04/13/2015: No plans were provided for review, so we cannot verify this was
addressed.
01/05/2015: No plans were provided for review, so we cannot verify this.
11/03/2014: Please add a space in the title as shown. See redlines.
Topic: Plat
Comment Number: 12 Comment Originated: 11/03/2014
04/14/2015: This has not been corrected.
01/05/2015: The title in the bottom right corner of sheet 2 is still incorrect. See
redlines.
11/03/2014: Please change the title to "Prospect- Riverside Subdivision
Second Replat".
Comment Number: 15 Comment Originated: 11/03/2014
04/14/2015: This has not been corrected.
01/05/2015: Please make this line and the property lines north & south of the
boundary a thinner line thickness. See redlines.
11/03/2014: Please show the west right of way line of Riverside Avenue. See
redlines.
Comment Number: 16
Comment Originated: 11/03/2014
04/14/2015: This has not been corrected.
01/05/2015: Please rotate the text so it is parallel to the right of way lines. See
redlines.
11/03/2014: Please provide dedication information for Riverside Avenue as
marked. See redlines.
Comment Number: 17
04/14/2015: This has not been corrected.
Comment Originated: 11/03/2014
ELEVATION:
BENCHMARK # w/ DESCRIPTION
ELEVATION:
If using NGVD29 UNADJUSTED the following equation statement will be
needed.
NOTE: IF NAVD 88 DATUM IS REQUIRED FOR ANY PURPOSE, THE
FOLLOWING EQUATION SHOULD BE USED: NAVD88 = NGVD29
UNADJUSTED + X.XX'
01/05/2015: Not all of the information has been added. The benchmark
statement must be exactly as shown below. The benchmark statement should
match on sheets 1 & 2.
11/03/2014: The City has moved to the NAVD88 vertical datum. Please
provide the following information in the format shown below.
If your project is started on NAVD88 datum:
1) PROJECT DATUM: NAVD88
BENCHMARK#1 w/ DESCRIPTION
ELEVATION:
BENCHMARK #2 w/ DESCRIPTION
ELEVATION:
OR, if project has already been surveyed in NAVD29 Unadjusted datum:
2) PROJECT DATUM: NGVD29 UNADJUSTED (OLD CITY OF FORT
COLLINS DATUM)
BENCHMARK #1 w/ DESCRIPTION
ELEVATION:
BENCHMARK #2 w/ DESCRIPTION
ELEVATION:
If using NGVD29 UNADJUSTED the following equation statement will be
needed.
NOTE: IF NAVD 88 DATUM IS REQUIRED FOR ANY PURPOSE, THE
FOLLOWING EQUATION SHOULD BE USED: NAVD88 = NGVD29
UNADJUSTED + X.XX6
Comment Number: 7
Comment Originated: 11/03/2014
04/13/2015: There are still line over text issues. See redlines.
01/05/2015: There are still line over text & text over text issues. See redlines.
11/03/2014: There are line over text issues. See redlines.
Comment Number: 27
Comment Originated: 01/05/2015
04/13/2015: All elevations need to be shown to the hundreth of a foot.
Topic: Construction Drawings
Comment Number: 7
Comment Originated: 11/11/2014
04/14/2015: LID table is still confusing; please update per the provided
sample.
01/06/2015: The LID table provided is a little confusing and it is unclear how
much of the site area is treated by LID techniques and how much of the
pavement is in pavers. ALso please note, the water quality pond is not
considered an LID treatment and should not be included in these calculations.
Perhaps a short meeting or phone conversation to go over the presentation of
this table is warranted.
11/11/2014: Please provide a table showing how the LID requirements are
being met. How much of the proposed pavement area is permeable pavers
and how much of the site is draining to an LID treatment area? A short narrative
in the drainage report may also be warranted but is not required.
Department: Technical Services
Contact: Jeff County, 970-221-6588, jcountv(&fcgov.com
Topic: Building Elevations
Comment Number: 1 Comment Originated: 11/03/2014
04/13/2015: There are still line over text issues. See redlines.
01/05/2015: There are still line over text issues. See redlines.
11/03/2014: There are line over text issues. See redlines.
Comment Number: 28 Comment Originated: 01/05/2015
04/13/2015: There still seems to be an issue. See redlines.
01/05/2015: There are cutoff text issues. See redlines.
Topic: Construction Drawings
Comment Number: 4 Comment Originated: 11/03/2014
04/13/2015: All benchmark statements must match the following exactly.
If your project is started on NAVD88 datum:
1) PROJECT DATUM: NAVD88
BENCHMARK # w/ DESCRIPTION
ELEVATION:
BENCHMARK # w/ DESCRIPTION
ELEVATION:
OR, if project has already been surveyed in NAVD29 Unadjusted datum:
2) PROJECT DATUM: NGVD29 UNADJUSTED (OLD CITY OF FORT
COLLINS DATUM)
BENCHMARK # w/ DESCRIPTION
Department: Stormwater Engineering
Contact: Dan Mogen, , dmogen a()fcgov.com
Topic: Construction Drawings
Comment Number: 14
04/14/2015: Please see redlines.
Topic: General
Comment Number: 15
Comment Originated: 04/14/2015
Comment Originated: 04/14/2015
04/14/2015: Please provide hydraulic calculations for the inlets and pipes to
show they can handle the 100-year storm. Also show adequate conveyance for
the area draining to the inlets to flow west to the pond without inundating the
buildings.
Comment Number: 16
Comment Originated: 04/14/2015
04/14/2015: A 3rd LID swale (west) is referenced in the drainage report but not
called out in the plans.
Comment Number: 17 Comment Originated: 04/14/2015
04/14/2015: Please look at bioretention as an option in the area of the 2 inlets
to help meet LID requirements.
Comment Number: 18
Comment Originated: 04/14/2015
04/14/2015: Alternative ComplianceNariance Application will need to be
submitted for approval of variance to LID requirements if they are not met.
Comment Number: 19 Comment Originated: 04/14/2015
04/14/2015: Please provide Standard Operating Procedures (SOPs) for the
LID complements, which will need to be included in the Development
Agreement (DA).
Comment Number: 20 Comment Originated: 04/15/2015
04/15/2015: Please provide a drainage easement for LID features including
pavers, underdrains, and swales.
Comment Number: 21 Comment Originated: 04/15/2015
04/15/2015: Please update drainage plan and report to include subbasins,
which will clarify areas draining LID features, area inlets, etc.
Topic: Landscape Plans
Comment Number: 13 Comment Originated: 04/14/2015
04/14/2015: How is the pond to be landscaped? Hatching for this area is not
show on the legend.
Contact: Jesse Schlam, 970.218.2932, ischlam cgov.com
Topic: Erosion Control
Comment Number: 11 Comment Originated: 01/06/2015
4/14/2015: Detail used allows water to go around the BMP and results in no
treatment of the water.
01/06/2015: Erosion Control Plan requires a'Rock Berm Detail'. Erosion
Control Escrow and Report both acceptable.
Contact: Shane Boyle, 970.221-6339, sboyle(a)fcgov.com
Comment Number: 1
Comment Originated: 11/12/2014
11/12/2014:
1. This project must be submitted as an S-2 parking garage/storage with 5000
sq.ft. max and meet 10ft min to property line or 20 ft between buildings ... or
2. Submit as U occupancies with 3000 sq.ft. max/fire walls and 5ft from property
line and 10 between bldgs.
Comment Number: 2
Comment Originated: 04/17/2015
04117/2015:
3. Any bldg over 5000 sq.ft. must be fire -sprinkled or have fire -containment.
4. Bldg F reguires the south wall to be 1-hour and parapet requirements.
Department: Light And Power
Contact: Justin Fields, 970-224-6150, ifields cgov.com
Topic: General
Comment Number: 1 Comment Originated: 11/10/2014
11/10/2014: Electric development and system modification charges will apply.
Contact Light and Power Engineering, 970-221-6700, for an estimate of these
charges. Overtime charges will apply since an outage will have to be taken to
the services utilizing the existing vault located on the NW comer of the property.
An online estimator is also available at:
http://www.fcgov.com/utilities/business/builders-and-developers/plant-investmen
t-development-fees/electric-development-fee-estimator?id=3.
Comment Number: 3 Comment Originated: 11/10/2014
11/10/2014: A C-1 form and a 1-line diagram will need to be submitted to Light
and Power Engineering. The C-1 form is available at
hftp://www.fegov.com/utilitiesfimg/site—specific/u ploads/c-1 _form. pdf.
Contact: Todd Vedder, 970.224-6152, Wedder(Mcaov.com
Topic: General
Comment Number: 6 Comment Originated: 04/14/2015
04/14/2015: Please show proposed transformer location on the Uility Plans
Comment Number: 8 Comment Originated: 04/14/2015
04/14/2015: It's hard to tell from the drawings but it looks like the proposed
transformer is located within the interior of a fence? It is advised to located the
transformer outside of a secured fenced area in the event there is an outage
and the crews need to have access to the transformer. If there is an outage and
transformer is located inside the gated area, they will not have access to the
transformer.
Comment Number: 9 Comment Originated: 04/14/2015
04/14/2015: Transformer must have an 8ft frontal and 3ft side/rear clearance.
Comment Number: 10
Comment Originated: 04/14/2015
04/14/2015: Ligth & Power will need the following items before design and
construction can be started: Approved site/utility plan, stamped plat, one -line
diagram and C-1 form and a digital AutoCAD drawing of the utility and site plan
layout.
1. A permit must be obtained from the City Forester before any trees or shrubs
as noted on this plan are planted, pruned or removed on the public right-of-way.
This includes zones between the sidewalk and curb, medians and other City
property. This permit shall approve the location and species to be planted.
Failure to obtain this permit may result in replacing or relocating trees and a
hold on certificate of occupancy.
2. Contact the City Forester to inspect all street tree plantings at the completion
of each phase of the development. All trees need to have been installed as
shown on the landscape plan. Approval of street tree planting is required before
final approval of each phase.
3. Street tree shall be supplied and planted by the developer using a qualified
landscape contractor.
4. The developer shall replace all dead and dying street trees after planting until
final maintenance inspection and acceptance by the City of Fort Collins Forestry
Division. All street trees in the project must be established of an approved
species and of acceptable le condition prior to acceptance.
5. Street tree locations and numbers may be adjusted to accommodate
driveway locations, utility standards, separation between trees, street signs and
street lights. Street trees shall be centered in the middle of the parkway.
Quantities shown on plan must be installed unless a reduction occurs to meet
separation standards.
Comment Number: 3
Comment Originated: 11/12/2014
04/15/2015: Continued
01/06/2015: This comment is continued from 11/12/14.
11/12/2014: Please add the following note on the landscape plan sheet 3 of 9
in large print with a bold border.
A free permit must be obtained from the City Forester before any street trees
are planted in parkways between the sidewalk and Curb. Street tree locations
and numbers may change to meet actual utility/tree separation standards.
Landscape contractor must obtain approval of street tree location after utility
locates. Street trees must be inspected and approved before planting. Failure
to obtain this permit is a violation of the Code of the City of Fort Collins.
Comment Number: 5
Comment Originated: 01/06/2015
04/15/2015: Continued
01/06/2015: For the Bur Oak listed in the plant list add Bullet Gall Resistant after
the botanical name. For Honeylocust please list it as follows in the plant list.
Botanical Name: Gleditsia triacanthos inermis'Skyline' Common name: Skyline
Honeylocust.
Department: Internal Services
Contact: Russell Hovland, 970-416-2341, rhoviand(a)fcaov.com
Topic: Building Insp Plan Review
04/17/2015: PLAT: Add all drainage easements as necessary for the LID
improvements per Storm water department.
Comment Number: 17
Comment Originated: 04/17/2015
04/17/2015: Permeable pavers and related underdrain needs to move further
east, outside of the new 15ft utility easement behind the drive approach.
Comment Number: 18
Comment Originated: 04/17/2015
04/17/2015: Once the location of the sewer service stub is determined please
note on the utility plan, and label the service stub to the main as existing.
Comment Number: 19 Comment Originated: 04/17/2015
04/17/2015: Please show and label the existing power vaults north of the new
drive.
Comment Number: 20
Comment Originated: 04/17/2015
04/17/2015: Update the transformer location on the utility plan. Location shown
on the Utility plan is conflicting from the Site plan.
Comment Number: 21 Comment Originated: 04/17/2015
04/17/2015: The concrete retaining wall footer around the back half of the
property is not entirely contained on the owners property. Per the detail on
sheet 4, footer extends onto adjacent properties. Easements are needed from
the (3) adjacent properties to construct this wall as designed. If footers are
revised and the wall is to be constructed this close to adjacent properties then
Temp construction/grading easements will be needed to construct the wall.
Comment Number: 22
Comment Originated: 04/17/2015
04/17/2015: Several LCUASS detail drawings have been updated. Please
update/add the following details:
LCUASS drawing 707.1 (replaces 707)
Add updated LCUASS drawing 1601
LCUASS drawing 1603 has been updated
Add updated LCUASS drawing 1607
Department: Forestry
Contact: Tim Buchanan, 970-221-6361, tbuchanan(a)fcgov.com
Topic: Landscape Plans
Comment Number: 1
Comment Originated: 11/12/2014
04/15/2015: Continued
01/06/2015: This comment is continued from 11/12/14.
11/12/2014:
If there are any significant existing trees on the site contact the City Forester for
an on -site meeting to obtain information for the tree inventory and mitigation
plan.
Comment Number: 2 Comment Originated: 11/12/2014
04/15/2015: Continued
01/06/2015: This comment is continued from 11/12/14.
11/12/2014:
Please provide the following street tree notes under a separate heading titled
Street Tree Notes.
Comment Number: 13
Comment Originated: 04/15/2015
04/15/2015: Need final hydrozone chart and typical planting details shown on
the plan set.
Comment Number: 14 Comment Originated: 04/20/2015
04/17/2015: Staff is concerned that with the building elevation change to add
tile to a portion of the building, the use of tile is too expansive. It would be more
appropriate to a tile material as an accent. If a tiled surface was used in place
of the EIFS, a more appropriate material would be a natural stone or masonry
veneer.
Department: Engineering Development Review
Contact: Sheri Langenberger, 970-221.6573, slangenberger@fcgov.com
Topic: General
Comment Number: 1
Comment Originated: 10/29/2014
10/29/2014: The building sqaure footage and the acreage was not correct on
the application form (did not match the plans) and an additional $322.00 is due
for TDRFees for the project.
Comment Number: 2 Comment Originated: 10/29/2014
10/29/2014: Any work that impacts Riverside will be limited to night work and
the roadway will need to be fully open for traffic during the day (which means that
the roadway will need to be plated for day use). Full closure of the roadway will
not be allowed. The project will need to plan for this and a paragraph identifying
this limitation will be placed in the DA. Notes need to be placed on the plans
indicating the restrictions.
Contact: Tyler Siegmund, 970-221.6501, tsiegmund(a)fcgov.com
Topic: General
Comment Number: 6 Comment Originated: 11/12/2014
01/12/2015: Please see redlines for other minor changes
11/12/2014: Please see redlines for other minor changes.
Comment Number: 9 Comment Originated: 01/12/2015
01/12/2015: Please provide additional elevation points for the sidewalk along
the frontage of the property. Sidewalk appears to reverse and drain to the east
at the private sidewalk connection into the site. See redlines
Comment Number: 14 Comment Originated: 04/17/2015
04/17/2015: LANDSCAPE PLAN: Please add a note to the street trees note
section: "Street Trees to be planted 5ft from the edge of detached sidewalk."
Comment Number: 15 Comment Originated: 04/17/2015
04/17/2015: SITE PLAN: Please add the standard sidewalk note:
"Any damaged curb, gutter and sidewalk existing prior to construction, as well
as streets, sidewalks, curbs and gutters, destroyed, damaged or removed due
to construction of this project, shall be replaced or restored to City of Fort
Collins standards at the Developer's expense prior to the acceptance of
completed improvements and/or prior to the issuance of the first Certificate of
Occupancy"
Comment Number: 16 Comment Originated: 04/17/2015
City of
Fort Collins
Community Development and
Neighborhood Services
281 North College Avenue
PO Box 580
Fort Collins, CO 80522
970.221.6750
970.224.6134 - fax
fcgov. com/developmentreview
April 20, 2015
Corey Seitz
1640 Riverside, LLC
1019 Club View Rd
Fort Collins, CO 80524
RE: Riverside Self -Storage, FDP140026, Round Number 3
Please see the following summary of comments from City staff and outside reviewing
agencies for your submittal of the above referenced project. If you have questions about
any comments, you may contact the individual commenter or direct your questions through
the Project Planner, Jason Holland, at 970-224-6126orjholland@fcgov.com.
Comment Summary.
Department: Planning Services
Contact: Jason Holland, 970.224-6126, iholland(Mcgov.com
Topic: General
Comment Number: 8 Comment Originated: 04/15/2015
04/15/2015: 1 would recommend getting rid of the sidewalk connection that has
stairs. This connection seems uneccessary and there are slope issues in the
sode area.
Comment Number: 9
Comment Originated: 04/15/2015
04/15/2015: Please adjust the storm line currently located west of the building
and move further west so that the proposed trees can be centered in the
western planting bed. Currently two of the tree are too close to the sidewalks.
Comment Number: 10
Comment Originated: 04/15/2015
04/15/2015: Looks like some final coordination is needed btw. the LS plan and
civil set, including the water service line that is now in conflict with tree location.
Once the major elements are adjusted, please reflect these changes in the
lighting plan, which will need to be included in the mylar set.
Comment Number: 11 Comment Originated: 04/15/2015
04/15/2015: Transformer needs to be updated on the civil set.
Comment Number: 12
Comment Originated: 04/15/2015
04/15/2015: Southern landscape area which is not visible can be removed and
incorporated as appropriate into the western planting beds.