Loading...
HomeMy WebLinkAboutDUTCH BROS. COFFEE, TIMBERLINE CENTER - MAJOR AMENDMENT - MJA150008 - CORRESPONDENCE -PROJECT DATUM: NAVD88 BENCHMARK # w/ DESCRIPTION ELEVATION: BENCHMARK # w/ DESCRIPTION ELEVATION: PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88 - X.XX�. Comment Number: 15 Comment Originated: 01/11/2016 02/16/2016: All benchmark statements must match on all sheets. 01/11/2016: All benchmark statements must match on all sheets. Comment Number: 16 02/16/2016: There are line over text issues. See redlines. 01/11/2016: There are line over text issues. See redlines. Topic: Site Plan Comment Number: 18 02/16/2016: There are spelling issues. See redlines. Department: Water Conservation Contact: Eric Olson, 970-221-6704, eolson@fcgov.com Comment Number: 1 Comment Originated: 01/11/2016 Comment Originated: 02/16/2016 Comment Originated: 01/05/2016 01/05/2016: Irrigation plans are required no later than at the time of building permit. The irrigation plans must comply with the provisions outlined in Section 3.2.1(J) of the Land Use Code. Direct questions concerning irrigation requirements to Eric Olson, at 221-6704 or eolson@fcgov.com Comment Number: Comment Originated: 01/05/2016 Department: Water -Wastewater Engineering Contact: Wes Lamarque, 970-416-2418, wlamargue@fcgov.com Topic: General Comment Number: 5 Comment Originated: 02/16/2016 02/16/2016: On the Utility plan, the meter pit leader references Note 1, but no note is located on the sheet. 4 02/17/2016: Electric capacity charges for underground electric systems for Timberline Center lots 1-14 have already been paid. kVA charges and secondary service charges will still apply to this project. Please refer to the web site referenced in comment number 6 for electric fee details. Comment Number: 3 Comment Originated: 02/17/2016 02/17/2016: Contact Light and Power Engineering to coordinate the transformer and electric meter locations, please show the locations on the utility plans. Comment Number: 4 Comment Originated: 02/17/2016 02/17/2016: Transformer locations shall be within 10' of a paved surface and must have a minimum of an 8' clearance from the front side and a 3' clearance around the sides and rear. (1000 kVA up to 2500 kVA requires 4' around the sides and rear.) Comment Number: 5 Comment Originated: 02/17/2016 02/17/2016: Please provide a one line diagram and a C-1 form to Light and Power Engineering. The C-1 form can be found at: http://zeus.fcgov.com/utils-procedures/files/EngWiki/WikiPdfs/C/C-1 Form.pdf Comment Number: 6 Comment Originated: 02/17/2016 02/17/2016: Please contact Light & Power Engineering if you have any questions at 221-6700. Please reference our policies, development charge processes, and use our fee estimator at http://www.fcgov.com/uti I ities/b usiness/b u i lders-and-developers. Department: PFA Contact: Jim Lynxwiler, 970-416-2869, Ilynxwiler@poudre-fire.ory Topic: General Comment Number: 1 Comment Originated: 02/17/2016 02/17/2016: SIGNS The dedicated fire lane shall be signed at a minimum of two locations (with indicating arrows) as per our development review meeting of 2/17/16. Code language provided below. > IFC D103.6: Where required by the fire code official, fire apparatus access roads shall be marked with permanent NO PARKING - FIRE LANE signs complying with Figure D103.6 of the IFC. Signs shall have a minimum dimension of 12 inches wide by 18 inches high and have red letters on a white reflective background. Signs shall be posted on one or both sides of the fire apparatus road as required by Section D103.6.1 or D103.6.2. Department: Technical Services Contact: Jeff County, 970-221-65889 'county@fcgov.com Topic: Construction Drawings Comment Number: 13 Comment Originated: 01/11/2016 02/16/2016: This does not match the format in previous comment. See redlines. 01/11/2016: Please provide the following information for the Benchmark Statement in the EXACT format shown below. 3 Comment Number: 18 Comment Originated: 02/16/2016 02/16/2016: Please remove the logo from the Cover Sheet Title. Department: Engineering Development Review Contact: Marc Ragasa, 970.221.6603, mragasa@fcgov.com Topic: General Comment Number: 7 Comment Originated: 01/12/2016 02/12/2016: Label all sidewalk ramps on Timberline Road and Bear Mountain Drive. 01/12/2016: Provide existing infrastructure 150' beyond property limits. Include items such as sidewalks, ramps, etc. Label sidewalk width on Timberline Road and Bear Mountain. Comment Number: 9 Comment Originated: 01/12/2016 01/12/2016: A letter of intent to complete offsite tie in to Lot 2 to the north is required prior to hearing. Comment Number: 14 Comment Originated: 02/12/2016 02/12/2016: Please add the standard sidewalk repair note to Sheet 4 (Utility & Demolition Plan) of the utility plan and the site plan: "Any damaged curb, gutter and sidewalk existing prior to construction, as well as streets, sidewalks, curbs and gutters, destroyed, damaged or removed due to construction of this project, shall be replaced or restored to City of Fort Collins standards at the Developer's expense prior to the acceptance of completed improvements and/or prior to the issuance of the first Certificate of Occupancy." Comment Number: 15 Comment Originated: 02/12/2016 02/12/2016: Please work with PFA to determine what signage or easement vacations are needed for the drive/parking areas that are within the Emergency Access Easement. Department: Forestry Contact: Tim Buchanan, 970-221-6361, tuchanan@fcgov.com Topic: Landscape Plans Comment Number: 1 Comment Originated: 01/19/2016 02/08/2016: 01 /19/2016: List the percentage of each tree species used and check that quantities meet the minimum species diversity standard LUC 3.2.1 D 3. Department: Light And Power Contact: Coy Althoff, CAlthoff@fcgov.com Comment Number: 1 Comment Originated: 02/17/2016 02/17/2016: Both single phase and 3-phase power is available to this site. Light & Power has electric facilities in the underground vault at the corner of Bear Mountain Dr. and Timberline Rd. that can be utilized for serving this property. Comment Number: 2 Comment Originated: 02/17/2016 2 Fort of Community Development and Neighborhood Services 281 North College Avenue PO Box 580 Fort Collins, CO 80522 970,221.6750 970.224.6134 - tax kgov. com/developmentreview February 19, 2016 One Fifty Five LLC 720 S Oklahoma St Kennewick, WA 99336 RE: Dutch Brothers Coffee - Timberline Center Major Amendment, MJA150008, Round Number 2. Please seethe following summary of comments from City staff and outside reviewing Agencies. If you have questions about any comments, you may contact the individual commenter or direct your questions through the Project Planner, Ted Shepard, at 970-221-6343 or tshepard@fcgov.com. Comment Summary: Department: Planning Services Contact: Ted Shepard, 970-221-6343, tshepard@fcgov.com Topic: General Comment Number: 13 Comment Originated: 01/13/2016 02/16/2016: In order to meet the allowable exception to the build -to line along Bear Mountain Drive, which would have the effect of placing the building no further back than 15 feet from the property line, the details of the patio area need to be established on one of the plan sheets. This could be done on the Site Plan or as a separate detail. Components may include, but not be limited to tables, chairs, picnic tables, trash containers, seat walls, and the like. Comment Number: 14 Comment Originated: 02/16/2016 02/16/2016: The applicant's response indicates that seven bike parking spaces are provided but only one rack is indicated on the site plan. It is not clear how seven bikes can be parked at one rack. Please clarify. Comment Number: 15 Comment Originated: 02/16/2016 02/16/2016: Please provide information on how many cars can be stacked behind the order window without impacting the private north -south drive. Comment Number: 16 Comment Originated: 02/16/2016 02/16/2016: Please show the approximate location of the directional signage for the drive -through lane. Comment Number: 17 Comment Originated: 02/16/2016 02/16/2016: On the Cover Sheet, please add to note number seven: "Under canopy light fixtures must be flush -mount with flat lens."