Loading...
HomeMy WebLinkAboutWINDSONG AT ROCK CREEK - PDP - PDP150024 - REPORTS - RECOMMENDATION/REPORT W/ATTACHMENTSY 7 O y L y � U Q2 Q 0 0 tY m rn am z N � - Denotes Lane Creek Drive SHORT RANGE (2020) GEOMETRY Figure 9 —/IL—DELICH -71 I -ASSOCIATES Windsong at Rock Creek TIS, October 2015 52 TABLE 4 Short Range (2020) Total Peak Hour Operation Intersection Movement Level of Service AM PM Ziegler/Rock Creek (signal) EB LT/T/RT D C C WB LT D WBT D C WB RT D C WB APPROACH D C NB LT A A NB T B A NB RT A A NB APPROACH A A SB LT A A SB T A B SB RT A A SB APPROACH A A OVERALL B B Rock Creek/Right-in/Right-out (stop sign) SB RT A A Rock Creek/Site Access (stop sign) EB LT A A SB LT/RT A A -/I LDELICH -71 [-ASSOCIATES Windsong at Rock Creek TIS, October 2015 51 w M Co w m Ln Co M Co N N N Co 71 /36 34/28 79/56 N :u 'u 5 0 o U) y L U Y a J w� t LL 112/146 10/29 0/0 N O 0/0 8/18 f 129/190 f 127/183 Rock Creek Drive 1 t ( 131/193 — 8/4 LO rn Lo 123/189 am Cn c uO m 0 a� o� a� i SHORT RANGE (2020) TOTAL PEAK HOUR TRAFFIC —/I L—DELICH -7,1 [—ASSOCIATES Figure 8 Windsong at Rock Creek TIS, October 2015 50 TABLE 3 Short Range (2020) Background Peak Hour Operation Intersection Movement Level of Service AM PM Ziegler/Rock Creek (signal) EB LT/T/RT D C WB LT D C WB T D C WB RT D C WB APPROACH D C NB LT A A NB T B A NB RT A A NB APPROACH A A SB LT A A SB T A B SB RT A A SB APPROACH A A OVERALL B B -/IL--DELICH -71 rASSOCIATES Windsong at Rock Creek TIS. October 201, 5 N f AM/PM co W ;LO LO MLO Go to110/138 IN N r- i— 10/28 �J � �l 1-- 7/17 Rock Creek Drive 71/36 � 33/28 —► rn m 79/56 Co C Co rn u') m 0 a� rn d z SHORT RANGE (2020) BACKGROUND PEAK HOUR TRAFFIC Figure 7 --/I I DELICH Windsong at Rock Creek TIS, October 2015 —7/ f=ASSOCIATES 48 z SITE GENERATED PEAK HOUR TRAFFIC -/,/LDELICH -71 rASSOCIATES 5 0 0 a+ N(n t M U Q N AM/PM Creek Drive Figure 6 Windsong at Rock Creek TIS, October 2015 47 TRIP DISTRIBUTION -/ILDELICH -7,1 [-ASSOCIATES 4 N AM/PM Rock Creek Drive Figure 5 Windsong at Rock Creek TIS, October 2015 MT r SITE PLAN - //_I DELICH -71 (-ASSOCIATES N Figure 4 Windsong at Rock Creek TIS, October 2015 45 TABLE 1 Current Peak Hour Operation I16rsection Movement Level of Service AM PM Ziegler/Rock Creek (signal) EB LT/T/RT D D WB LT D C WB T D C WB RT D C WB APPROACH D C NB LT A A NB T A A NB RT A A NB APPROACH A A SB LT A A SB T A A SB RT A A SB APPROACH A A OVERALL B A TABLE 2 Trip Generation Code use AWDTE size Raft Trig AM Peak Hour PM Peak Hour Rate In Rate Out Rab In Rate Out 620 Nursing Home 64 Beds EQ. 134 0.12 6 0.05 3 0.07 4 0.15 10 AIL—DELICH -.0 rASSOCIATES Windsong at Rock Creek TIS, October 2015 N CO co r � rn 100/125 N N cD — 9/25 f + � 6/15 64/33 --14( 1 t r 30/25 — M h 72/51 Co f m � ul m 0 tY m o� 0 N AM/PM Rock Creek Drive RECENT PEAK HOUR TRAFFIC Figure 3 -.// LDELICH Windsong at Rock Creek TIS, October 2015 -7/ r-ASSOCIATES 43 0 0 m a EXISTING GEOMETRY —//L—DELICH -7 ja [—ASSOCIATES N .16 - Denotes Lane Rock Creek Drive Figure 2 Windsong at Rock Creek TIS, October 2015 42 N Timberwood Drive Windsong at Rock Creek Y f0 d O O C L U Rock Creek Drive Cn o U N Q N rn N = tl SCALE: 1 "=500' SITE LOCATION --//L—DELICH -7 jf rASSOCIATES Figure 1 Windsong at Rock Creek TIS, October 2015 41 Based upon Fort Collins Bicycle LOS criteria, there is one destination area within 1320 feet of the Windsong at Rock Creek site: Fossil Ridge High School to the southeast. Appendix F contains a Bicycle LOS Worksheet. Bicyclists will have access to Ziegler Road and Rock Creek Drive. The bicycle level of service will be met. Currently, this area is served by Transfort route 16. The nearest bus stop is at the Ziegler/Rock Creek intersection. It is concluded that, with development of the Windsong at Rock Creek, the future level of service at the key intersections will be acceptable. The Rock Creek/Right- in/Right-out Access intersection should be designed to discourage left turns. An eastbound left -turn lane will be restriped at the Rock Creek/Full Movement Access intersection. The driveway spacing along Rock Creek Drive meets the spacing criteria in Table 7-3 in LCUASS. The pedestrian and bicycle level of service will be met. --/I' DELICH Windsong at Rock Creek TIS, October 2015 -71 [—ASSOCIATES 40 Figure 8 shows the short range (2020) total morning and afternoon peak hour traffic at the Ziegler/Rock Creek, Rock Creek/Right-in/Right-out Access, and Rock Creek/Full Movement Access intersections. Table 4 shows the short range (2020) total morning and afternoon peak hour operation at the key intersections. Calculation forms are provided in Appendix E. The Ziegler/Rock Creek, Rock Creek/Right-in/Right-out Access, and Rock Creek/Full Movement Access intersections will meet the City of Fort Collins Motor Vehicle LOS Standards during the morning and afternoon peak hours with the existing control and geometry. The recommended short range (2020) geometry is shown in Figure 9. The existing geometry at the Ziegler/Rock Creek intersection is appropriate. The right- in/right-out access should be designed to discourage other traffic movements. Although the trip generation/assignment shows little traffic, the City may desire an enhanced channelization island at this access. Right -turn lanes are not required at the site access intersections based on Figure 8-4 in LCUASS. According to Figure 8-1 in LCUASS, an eastbound left -turn lane is not required at Rock Creek/Full Movement Access intersection. However, with other potential developments using the site access in the future, Windsong at Rock Creek will restripe this section of Rock Creek Drive to provide an eastbound left -turn lane. According to LCUASS, Chapter 7, Table 7-3, on major collector streets, the distance between high volume driveways and intersections is 200 feet (minimum). The corner clearance between driveways/alleys (not high volume) and street intersections is 175 feet (minimum). The distance between driveway edges is 75 feet (minimum). The Right-in/Right-out Access will not be a high volume driveway. The Full Movement Access will likely have volumes commensurate with that of a high volume driveway in the future, since it will serve other parcels north of Rock Creek Drive. There are two driveways that will provide access to the Windsong at Rock Creek site on the north side of Rock Creek Drive. According to the site plan, the Right-in/Right-out Access is 198 feet east of Ziegler Road (centerline to centerline). Therefore, the Right-in/Right-out Access meets the corner clearance spacing criterion. The distance between the Right- in/Right-out Access and the Full Movement Access is 253 feet (centerline to centerline). Therefore, the spacing between the Right-in/Right-out Access and the Full Movement Access meets the driveway spacing criterion. The distance between the Full Movement Access and the driveway to the south (serves Fossil Ridge High School) is 177 feet. This separation meets the driveway spacing criterion. The Windsong at Rock Creek site is in an area within which the City requires pedestrian and bicycle level of service evaluations. Appendix F shows a map of the area that is within 1320 feet of the Windsong at Rock Creek site. The Windsong at Rock Creek site is located within an area termed as "transit corridor," which sets the pedestrian level of service threshold at LOS C for all measured categories, except for Directness and Security at LOS B. There are two destination areas within 1320 feet of the proposed development at Windsong at Rock Creek: 1) the residential area to the west and 2) Fossil Ridge High School to the southeast. This development will build sidewalk along the site frontage. Appendix F contains a Pedestrian LOS Worksheet. The pedestrian level of service will be met. —// LDELICH 1 rASSOCIATES Windsong at Rock Creek TIS, October 2015 39 Figure 3 shows recent peak hour counts at the Ziegler/Rock Creek intersection. The traffic volumes at the Ziegler/Rock Creek intersection were collected in May 2015. Raw traffic data is provided in Appendix B. Table 1 shows the current morning and afternoon peak hour operation of the Ziegler/Rock Creek intersection. The Ziegler/Rock Creek intersection currently meets the City of Fort Collins Motor Vehicle LOS Standards during the morning and afternoon peak hours with existing control and geometry. Calculation forms are provided in Appendix C. A description of level of service for signalized and unsignalized intersection from the 2010 Highway Capacity Manual is provided in Appendix C. Table 4-3 (revised per staff comments regarding type of intersection) showing the Fort Collins Motor Vehicle LOS Standards (Intersections) are also provided in Appendix C. The Windsong at Rock Creek site is in an area termed "other." In areas termed "other," acceptable overall operation at signalized intersections during the peak hours is defined as level of service D or better. At signalized intersections, acceptable operation of any leg and any movement is level of service E. At unsignalized intersections, acceptable operation is considered to be at level of service E for any approach leg for an arterial/arterial, arterial/collector and arterial/local intersections. In such areas, it is expected that there would be substantial delays to the minor street movements at unsignalized intersections during the peak hours. This is considered to be normal in urban areas. At unsignalized collector/local intersections, acceptable operation is considered to be at level of service C for any approach leg. Figure 4 shows the site plan for the development at Windsong at Rock Creek. The development at Windsong at Rock Creek is a 64 bed memory care facility. Currently the site is vacant. Access to the site will be via a right-in/right-out access and a full movement access to/from Rock Creek Drive. Trip generation is important in considering the impact of a development such as this upon the existing and proposed street system. Nursing Home (Code 620) in Trip Generation, 9th Edition, ITE was used to estimate the trips that would be generated by the proposed/expected uses at a site. This land use category best fits a memory care facility. A trip is defined as a one-way vehicle movement from origin to destination. Table 2 shows the expected trip generation on a daily and peak hour basis. The trip generation of the Windsong at Rock Creek development resulted in 134 daily trip ends; 11 morning peak hour trip ends; and 14 afternoon peak hour trip ends. Directional distribution of the generated trips was determined for Windsong at Rock Creek site and is shown in Figure 5. Figure 6 shows the site generated peak hour traffic assignment of Windsong at Rock Creek. Figure 7 shows the short range (2020) background morning and afternoon peak hour traffic at the Ziegler/Rock Creek intersection. Background traffic volume forecasts for the short range (2020) future were obtained by reviewing traffic studies for other developments in this area and reviewing historic counts in the area. Traffic volumes at the Ziegler/Rock Creek intersection were increased at a rate of 2.0 percent per year. Table 3 shows the short range (2020) background morning and afternoon peak hour operation at the Ziegler/Rock Creek intersection. Calculation forms are provided in Appendix D. The Ziegler/Rock Creek intersection will meet the City of Fort Collins Motor Vehicle LOS Standards during the morning and afternoon peak hours with the existing control and geometry in the short range (2020) future. —/y I DELICH Windsong at Rock Creek TIS, October 2015 -71 rASSOCIATES 38 DELICH ASSOCIATES Traffic & Transportation Engineering 2272 Glen Haven Drive Loveland, Colorado 80538 Phone: (970) 669-2061 Fax: (970) 669-5034 �7, 1,' r MEMORANDUM TO: Tim Halopoff/Ken Merritt, JR Engineering, LLC City of Fort Collins FROM: Joseph Delich DATE: October 21, 2015 SUBJECT: Windsong at Rock Creek Transportation Impact St (File. 1576ME01) This memorandum addresses the transportation impacts of the proposed Windsong at Rock Creek development. The site location is shown in Figure 1. The Windsong at Rock Creek development is a 64 bed memory care facility in the northeast quadrant of the Ziegler/Rock Creek intersection in Fort Collins, Colorado. The scope of this study was discussed with the Fort Collins Traffic Operations Engineer. A brief memorandum was requested. The Base Assumptions form is provided in Appendix A. Figure 2 shows the current geometry at the Ziegler/Rock Creek intersection. Ziegler Road is to the west of (adjacent to) the proposed Windsong at Rock Creek site. It is a north -south street classified as a four -lane arterial street, north of Rock Creek Drive, and a two-lane arterial street, south of Rock Creek Drive, according to the Fort Collins Master Street Plan. Currently, Ziegler Road has a four -lane cross section, north of Rock Creek Drive, and a two-lane cross section, south of Rock Creek Drive. At the Ziegler/Rock Creek intersection, Ziegler Road has a northbound and southbound left - turn lane, a through lane in each direction, and a northbound and southbound right -turn lane. The Ziegler/Rock Creek intersection has signal control. The posted speed limit in this area of Ziegler Road is 40 mph. There is a sidewalk along both sides of Ziegler Road. south of Rock Creek Drive, and a sidewalk along the west side of Ziegler Road, north of Rock Creek Drive. There are bicycle lanes along Ziegler Road. Rock Creek Drive is to the south of (adjacent to) the proposed Windsong at Rock Creek site. It is an east -west street classified as a collector street according to the Fort Collins Master Street Plan. Currently, Rock Creek Drive has a two-lane cross section in this area. At the Ziegler/Rock Creek intersection, Rock Creek Drive has a westbound left -turn lane, a westbound through lane, a westbound right -turn lane, and an eastbound left-turn/through/right-turn lane. The is posted speed limit on Rock Creek Drive is 30 mph, east of Ziegler Road, and 25 mph, west of Ziegler Road. There are sidewalks along both sides of Rock Creek Drive, west of Zeigler Road, and a sidewalk along the south side of Rock Creek Drive, east of Ziegler Road. There are bicycle lanes along Rock Creek Drive. 37 Attachment 5 A. That is a landscaped area and an employee break area. 11.What is the road on the east side of the site? A. This is a private access drive, not a public street, that serves our site as well as future development to the north. 12. So there is no direct access out to Ziegler Road? A. That is correct, sole access is to Rock Creek Drive at the two locations shown. 13.Are you connecting to the site with a drive to the north from your parking lot? A. That connection is shown at the request of the Poudre Fire Authority who may need an emergency access easement to serve our site from the north, or the north site from our site, as a secondary point of access. 14. It looks like given the size and scale of the project, there could be more landscaping along Ziegler. A. Thank you for the comment. These plans are conceptual and we will add more specific detail for the formal submittal to the City. 15. You mentioned that certain security measures will be implemented to prevent any of the residents from leaving the premises. Could you describe these measures? A. Yes, the term in the trade is known as "elopement' and to prevent this we have two enclosed courtyards and two external courtyards that are enclosed by a fence or decorative wall. We prefer that this fence or wall be eight feet so that there is no visual attraction over the fence that may encourage a resident to wander off. This will be an attractive fence / wall and not simply 8 feet of solid wood fencing. 16. How long is the average stay? A. About 2 — 3 years. Our longest running resident was 12 years. 17.You mentioned outside professional staff coming on -site to provide services. Do residents also leave the site to receive medical services? A. Yes, we have a bus that transports residents to off -site appointments and various activities. For example, at our Salem, Oregon facility, our residents made dog and cat toys and then visited the Humane Society to deliver toys and engage with the staff and the animals. 3 36 Attachment 5 2. What are the building setbacks? A. The building is setback about 40 feet from Ziegler and about 110 feet from Rock Creek Drive. 3. The green area that is shown in front of the building, is that a stormwater detention area? A. Yes, the area in southwest corner of the site is set aside as a stormwater detention pond. In addition, the frontage along Rock Creek Drive is also shown to be for stormwater detention as the site generally slopes from west to east. 4. Where does the stormwater go? A. All storm flows are directed, after detention, to a regional stormwater pond on the east side of Technology Parkway. 5. Is there an irrigation ditch along Ziegler? What will happen to this ditch? A. Yes, there is an existing irrigation ditch that serves both Fossil Ridge High School and the City of Fort Collins Parks Department further to the south and east. This ditch will be placed in a pipe. 6. How many residents will the facility serve? A. We plan on a capacity of 64 residents. 7. How many employees will you have? A. We will have about 24 full-time equivalent employees. This means about 36 total employees. We expect to have approximately 22 employees on one shift during peak time. 8. Will there be enough parking? A. Yes, we will have about 48 parking spaces. The parking spaces along the front will be reserved for visitors. Employees will park on the north side of the building. The number of parking spaces is also intended to allow for visiting professional staff such as physical therapists, primary doctors, etc. 9. Will there be a registered nurse on staff? A. Yes. 10. What is the green area and the concrete area in the northwest corner? 4 35 Attachment 5 NEIGHBORHOOD INFORMATION MEETING PROJECT: Windsong at Rock Creek, Long Term Care Facility LOCATION: Northeast Corner of Ziegler Road and Rock Creek Drive DATE: September 24, 2015 APPLICANT: Don Harris, Windsong Long Term Care CONSULTANTS: Mark Lowen, Lennity Architecture, 3150 Kettle Court SE, Salem, OR 97301 CITY PLANNER: Ted Shepard, Chief Planner The meeting began with a description of the proposed project. As proposed, the project consists of a long-term care facility located at the northeast corner of Ziegler Road and Rock Creek Drive on Parcel C of the Harmony Technology Park. The primary focus is to serve the needs of people living with Alzheimer's disease and other related dementia. The site is 3.32 acres. The one-story building will be approximately 37,000 sq. ft. and contain a 64-beds arranged in individual apartments with central dining. There will be 48 parking spaces provided to serve the project. There will be approximately 22 employees on the largest shift. The parcel is located in the Harmony Corridor (H-C) zone district. This proposal will be subject to review and consideration by the Planning & Zoning Board at a future public hearing with the date to be determined. Unless otherwise noted, all responses are from the applicants and consultant. QUESTIONS, COMMENTS, CONCERNS 1. What are the sizes of the rooms? Are any rooms shared? A. We have two types of rooms. The singles are about 200 square feet and the shared rooms are about 180 square feet per resident. Please note that the only portion that is shared is the bathroom. The rooms, while on the small side, are intended to not become mini -apartments, but, rather, to encourage residents to get out and circulate and join the activities and enjoy the common amenities. 34 Attachment 4 implemented. Landscape berms undulate along the western boundary to provide visual and audible buffering from the arterial road. LIV 15.2 — Seek Compatibility with Surrounding Development: This project is compatible with the surrounding area in use and intensity based upon the existing business, commercial use and residences in close proximity to the site. The building design is compatible with both commercial and residential developments. LIV 30.1— Provide a Balanced Circulation System & LIV 30.3 — Improve Pedestrian and Bicycle Access & LIV 30.4—Reduce Visual Impacts of Parking: Windsong at Rock Creek includes public pedestrian improvements, improved access to surrounding developments and buffers parking areas from Public Rights -of -Way. Bicycle parking is provided at both entrances, which are connected by private onsite sidewalks to the public sidewalks. LIV 31.2 — Site Layout and Building Orientation & LIV 31.4 — Design for Pedestrian Activity & The primary entrance of the Windsong at Rock Creek building is oriented toward pedestrian areas and has an enhanced pedestrian connection to both Rock Creek Drive and Ziegler Road. LIV 38.3 —Land Use Transitions This project is right at the edge of the employment district. It is a perfect transition from the high school and nearby residential properties to the future commercial developments intended for the parcels north and east of the site. Safety and Wellness SW 1.S - Maintain Public Safety through Design: The Windsong at Rock Creek project is designed with security in mind. The lighting layout provides visibility in areas with additional security needs like parking areas and on walkways. The landscape plan is designed to avoid hidden area and to promote visibility across the site. Transportation T 3.1— Pedestrian Mobility & T 3.2 — Bicycle Facilities & T 12.1— Connections T 12.4—ADA Compliance: Windsong at Rock Creek includes ADA compliant public pedestrian improvements and private improvements to increase access to surrounding existing and future developments. Bicycle parking is provided at both entrances, which are connected by private onsite sidewalks to the public sidewalks to encourage bicycle usage. ....................... ................................. .................................................... .I ...................... ................. .__..................................... , 3150 Kettle Court SE Salem, OR 97301 P 503 399 1090 f 503 399 0565 w lenityarchitecture.com ARCRREMRE s PU NING ................................................................................................................................................................................................. 33 Attachment 4 Community and Neighborhood Livability LIV 5.4 — Contribute to Public Amenities: The site development for this project includes public facilities adjacent the site including ADA accessible pedestrian amenities along Ziegler Road and Rock Creek Drive, landscaped tree lined streetscapes, and site amenities adjacent to the Public Right -of -Way. LIV 6.2 — Seek Compatibility with Neighborhoods & LIV 6.3 — Encourage Introduction of Neighborhood -Related, Non -Residential Development: This project is compatible with the surrounding area in use and intensity based upon the existing business, commercial use and residences in close proximity to the site. The building design is compatible with both commercial and residential developments. LIV 7.1— Encourage Variety in Housing Types and Locations & LIV 7.5 — Address Special Needs Housing & Policy & LIV 7.6 — Basic Access: Windsong at Rock Creek is a unique housing opportunity for a very specific population. This facility will add housing options to the community and provides for those with special memory care needs. The facility will be ADA accessible and will provide a functional living opportunity for those with a variety of mobility concerns. LIV 10.1— Design Safe, Functional, and Visually Appealing Streets & LIV 10.2 — Incorporate Street Trees LIV 10.5 — Retrofit Existing Streetscapes: Ziegler Road will be enhanced with the addition of street trees, landscaped berms, and by strategically placing pedestrian entry points near building entrances. Rock Creek Drive will be provided with a landscaped parkway and street trees. The proposed landscape design will greatly improve the visual quality and character of the existing streetscape as viewed from the surrounding neighborhoods, pedestrian ways, and vehicles passing by. LIV 12.1 — Design for Crime Prevention and Security & LIV 12.2 — Utilize Security Lighting and Landscaping: The landscape and lighting for the project is designed with security in mind. The lighting layout provides visibility in areas with additional security needs like parking areas and on walkways. The landscape plan is designed to avoid hidden area and to promote visibility. LIV 14.1 — Encourage Unique Landscape Features & LIV 14.2 — Promote Functional Landscape & LIV 14.3 — Design Low Maintenance Landscapes: The landscape design is centered on providing a reasonably maintainable, safe and natural living environment for residents of the memory care facility. More than half the planting areas consist of low and very low water use. Lawns have been confined to areas of high visual impact. Landscaping has been designed to be very functional, especially in areas where stormwater management is ..................................................................................................................................................................................................... 3150 Kettle Court SE Salem, OR 97301 P 503 399 1090 1503 399 0565 w lenityarchitecture.com ARCHITECTURE A PUWNING ..................................................................................................................................................................................................... 32 Attachment 4 Parking & Traffic • The standard in the Land Use Code for Long -Term Care Facilities is .33/bed plus parking for employees on the major shift. With 64 beds and 22 employees, the standard is calculated as 43 spaces. The proposed 51 spaces is sufficient parking for employees, visitors and guests. • A traffic memo was prepared for this project and is included in this submission. The traffic analysis concluded that there will be less than 12 AM peak hour trips and 15 PM peak hour trips. The conclusion was that with the development of the project, the future level of service would be acceptable. City Plan Principles and Policies The City Plan Principles and Policies achieved by this development are as follows: Economic Health EH 1.1— Support Job Creation: The proposed Windsong at Rock Creek Memory Care Facility will provide 35 skilled jobs to the community. These jobs support the economic health of the community. EH 3.1—Support Programs Emphasizing Local Business: Facilities for the ageing population is a needed asset to the City of Fort Collins. Providing specialized facilities like the Windsong at Rock Creek project allow residents and their families to stay in Fort Collins rather than look for services outside of the community. Environmental Health ENV 8.3 - Employ a Citywide Approach & ENV 8.6 — Prevent Pollution: Providing the unique services offered by the Windsong at Rock Creek project has the potential to reduce emissions by keeping residents or their family members from traveling outside the city to get the services they need for their family members. ENV 19.2 — Pursue Low Impact Development: This project will meet the City's Low Impact Development (LID) requirements to minimize the impact of the development on urban watersheds. ENV 20.2 — Follow Design Criteria for Stormwater Facilities: The Windsong at Rock Creek project utilizes Best Management Practices (BMPs). The site specific BMPs proposed include permeable interlocking concrete pavers, grass swales, and an extended detention basin for water quality treatment. ...................................................................................................................................................................................................... 3150 Kettle Court SE Salem, OR 97301 P 503 399 1090 f 503 399 0565 w lenityarchitecture.com ARCHITECTURE a PLANNING ...................................................................................................................................................................................................... 31 Attachment 4 Conceptual Review • The proposed development had a Conceptual Review Meeting on July 20, 2015 under the title Harmony Technology Park - Long -Term Care Facility • The design concern brought up during the Conceptual Review was the build -to requirements of the Land Use code. The nature of a Memory Care facility requires a drop off area at the front of the building which limits the ability to push the building up toward the street as required by the code. In further discussions with the planning department and some site design changes a consensus was reached that with the proposed pedestrian amenities, this design is an acceptable exception to the required build -to standard. • The original design showed an emergency access only drive exiting onto Ziegler Road. The planning department requested that the fire department consider alternative designs. The civil engineer on the project met with Poudre Fire Authority and they discussed the current proposal, which provides an emergency access easement to the northern property line. When the site to the north develops, a connection could be made to provide a through fire access drive. Design Rationale • The site is designed to orient the main entry toward Rock Creek Drive with a berm and landscape buffer along Ziegler Road. The south facing entry provides weather protection for residents and visitors. The site is designed with a shared access drive that will connect future developments North and East of the site to the development and also provide a through access road to Rock Creek and Precision Drive. • The front entry and drop off area has been designed to allow vehicles to return to the parking area east of the entry without exiting onto Rock Creek Drive. • Currently the site is developed for agricultural purposes. No existing natural features, trees, wetlands, or open spaces exist onsite. • The site has been designed with extensive pedestrian amenities to connect the building to the public rights of way and to mitigate the increased setback required by the use for the front drop off area. • Sidewalks connect the site to the adjacent parcels to encourage connectivity to future developments. • Service locations have been placed on the site at the area farthest from the public right of way and is provided with screening with both and enclosure and appropriate landscaping. • Onsite stormwater management is proposed and has been incorporated into the landscape design. • The building is a single story structure that is compatible with the surrounding area. The building is an appropriate size for the site and is in character with the use and the surrounding developments. Neighborhood Meeting • No significant issues were raised at the neighborhood meeting. The questions were about some of the graphic items on the site plan and the nature of the facility. No major issues were brought up that needed to be addressed. ........................ ....... .....__ _ _ _ _ ___.................................................................................................................................... 3150 Kettle Court SE Salem, OR 97301 1, 503 399 1090 f 503 399 0565 . lenityarchitecture.com ARCMTECTURE s PLARRIRG ....................................... _. _.......................................................................................................................................... 30 Attachment 4 lenity architecture Windsong at Rock Creek Project Development Plan Statement of Planning Objectives Project Description & Introduction November 18, 2015 • The subject parcel is a 3.337-acre piece of an 18.70-acre parcel, generally located on the NE corner of Ziegler Road and Rock Creek Drive. The existing zoning is Harmony Corridor District (HC) and the site is located within the Harmony Technology Park Overall Development Plan. • The subject parcel is currently vacant and is used for agricultural purposes. There are no natural features, existing trees, or natural areas that required preservation. • The area around the subject parcel is currently developed or included in an overall plan for development. • The PDP proposal is to subdivide the parcel and develop a 38,303 SF, 64-bed memory care facility. The City of Fort Collins Land Use Code defines this use as a Long -Term Care Facility, which is an allowed use in the Harmony Corridor District (HC) with a Type II review by the Planning & Zoning Commission. • The Windsong at Rock Creek Memory Care facility will be a state licensed facility that expects to have approximately 35 employees. • No new street names are proposed with this project. • The project is to be developed in a single phase. Construction is expected to begin Fall of 2016 with completion expected in 2017. Property & Development Ownership • The current property owner is: Harmony Technology Park, LLC a Colorado limited liability company Mark S. Melchi & Jeffery T. Harshe South State Commons I 2723 South State Street, Suite 250 Ann Arbor, MI 48104 • Upon closing on the property prior to the start of construction, the property owner will be Vista Pointe Development Co., LLC. They are the current contract purchaser on the property and will be the owner and operator of the proposed memory care facility. Vista Pointe Development Co.,LLC Don Harris and Mike Zingg 1883 SW Vista Avenue Portland, OR 97201 • Lenity Architecture is the applicant and consultant to Vista Pointe Development who is submitting this application with the full knowledge of the existing property owner. ...................................................................................................................................................................................................... 3150 Kettle Court SE Salem, OR 97301 P 503 399 1090 + 503 399 0565 - lenityarchitecture.com P CHRECTURE 6 PI NING ...................................................................................................................................................................................................... 29 lenity architecture Windsong at Rock Creek Fort Collins, Colorado Wall / Berm Detail Nov. 18 2015 TRIM: GRIZZLE 1 SIDING: 51 INTELLECTUAL GRAY MOONLIGHT ROUGHCUT J Ienity Windsong at Rock Creek Materials Board arc itecture Fort Collins, Colorado Nov. 18 2015 lenity archRedu V rra aV-M.1'TYPeII��I WTI Windsong at Rock Creek Fort Collins, Colorado KEY WTEW WLO Color Elevations Nov. 18 2015 SCREEN WALL �FAELEVA�O_� (SHOWN WITHOUT SCREEN WALL) i.,1WEST ELEVATION (SHOWN WITHOUT SCREEN WALL) T KEYPLAN lCI" t f Windsong at Rock Creek Elevations marchitecture 9 SCALE: AS DATE: 18 oTEo Port Collins, CO . sm M loin .sas sss oscs �.� tJ lenity architecture nso Kan can 9E selan a�pon emu. , SO11991090 5031990565 qa mm F 91 Windsong at Rock Creek Fon Callin., CO EAKDOWN: iE: rK1VAi o bUi in: 7,"0 SF SEMI -PRIVATE SUITES: 9,920 SF TOTAL SUITES: 17,360 SF TOTAL AREA: 38,303 SF ACTIVE RECREATION USE AREA: COURTYARDS: 4,792SF ENCLOSED YARDS: 3 608 SF TOTAL AREA: 4,400 SF FLOOR PLAN DATE: 18 Nov. 2015 SCALE: 3W . 1'4r No Text 0 a 0 w w J C1 W IV lenity arcmtur ,ire ROCK CREEK DRIVE Windsong at Rock Creek Fort Collins, Colorado Color Site Plan FOR REFERENCE ONLY Jan. 12 2016 Agenda Item 2 C. The P.D.P. is a permitted use and complies with the applicable land development standards of the Harmony Corridor zone district in accordance with Article Four. D. The Major Amendment complies with the applicable General Development Standards of Article Three. RECOMMENDATION: Staff recommends approval of Windsong at Rock Creek, P.D.P., #PDP150024. ATTACHMENTS 1. Site Plan (PDF) 2. Landscape Plan (PDF) 3. Architectural Elevations (PDF) 4. Statement of Planning Objectives (PDF) 5. Neighborhood Meeting Summary (DOCX) 6. Transportation Impact Study (PDF) Item # 2 Page 8 21 Agenda Item 2 are two entry portals located at the public sidewalk that invite and lead the pedestrian to the plaza and entrance. Each portal consists of decorative columns, beams and a trellis and are intended to break down the visual distance between the public street and the entry plaza due to the size and scale of the building. Staff finds that use of entry portals is an effective design solution that enhances the relationship between the building the public streets in an industrial park -like environment. I. Section 3.5.3(B)(2) — Orientation to Build -to Lines for Streetfront Buildings The P.D.P. complies with this standard by creating a plaza that includes a significant amount of landscaping, seat walls and outdoor gathering space. This plaza ties into the main entrance which is made prominent by architectural features. As mentioned, this plaza connects to the public sidewalks along both streets. Ziegler Road is a four -lane arterial and Rock Creek is a collector with no parking. As such, both streets are more suburban in character than urban which would otherwise require a closer building relationship to the street. In fact, the Landscape Plan is specifically designed to attenuate the road noise associated with an arterial street. Given this context, the building is pulled back from the property line in excess of 15 feet. Together, the prominent entry feature, plaza, connecting walkways and entry portals combine to comply with the allowable exception to the build -to line requirement per Section 3.5.3(B)(2)(d)l . J. Section 3.6.4 — Transportation Level of Service Requirements As mentioned, Ziegler is an arterial street which prohibits a driveway connection. Rock Creek is a collector allowing the project two access points. The westerly driveway would be restricted to right -out only turn movements due to its proximity to the intersection with Ziegler Road. The easterly driveway will allow for full -turning movements onto Rock Creek Drive. This driveway will connect to Precision Drive and includes a continuous sidewalk along the west side. The Transportation Impact Study concludes that, with full development of this P.D.P., the future vehicular Level of Service at the key intersections will be acceptable. In addition, acceptable level of service is achieved for pedestrian, bicycle, and transit modes (Transfort Route 16) based upon the measures in the Multi -Modal Transportation Level of Service Manual. 6. Neiahborhood Information Meetin A neighborhood information meeting was held on September 24, 2015. A summary of this meeting is attached. Questions about the operation of the facility were answered satisfactorily. Concerns about the site plan, landscaping, traffic, parking, and stormwater runoff were raised and addressed by the Windsong representatives. 7. Findings of Fact/Conclusion: In evaluating Windsong at Rock Creek, P.D.P., Staff makes the following findings of fact: A. The P.D.P. is in compliance with land use and development standards of the Harmony Corridor Plan. B. The P.D.P. complies with the Harmony Technology Park Overall Development Plan, Seventh Amendment. Item # 2 Page 7 20 Agenda Item 2 The scale of the Harmony Technology Park is large. For example, by way of comparison, the three projects within the H.T.P. along Ziegler Road (from north to south) are as follows: Use Building Sizes . ft. Parkin Site acres Intel 199,194 625 34.4 Main Street Health 48,158 100 7.5 Eye Care Medical Office 32,903 209 4.16 Windsong Long Term Care 38,303 64 3.38 Given the size and scale of these existing and proposed facilities, the 13 extra spaces requested by Windsong appears nominal and inconsequential when compared to the surrounding context. Staff recommends approval of the Alternative Compliance to allow 13 extra spaces because request complies with the applicable standards in that the parking lot is planned and landscaped in such a way that it: 1. does not detract from continuity, connectivity and convenient proximity for pedestrians between or among existing or future uses in the vicinity, 2. minimizes the visual and aesthetic impact along the public street by placing parking lots to the rear or along the side of buildings, to the maximum extent feasible, 3. minimizes the visual and aesthetic impact on the surrounding neighborhood, 4. creates no physical impact on any facilities serving alternative modes of transportation, 5. creates no detrimental impact on natural areas or features, 6. maintains handicap parking ratios. F. Section 3.2.4 — Site Lighting Parking lot pole lighting and wall -mounted sconces will feature down -directional and full cut-off fixtures. There are no foot-candles that exceed the maximum allowable. G. Section 3.5. 1 (B) (C) (E) (F) — Building Project and Compatibility The one-story building evokes a residential character although at a relatively large scale. The roof is pitched with multiple rooflines and gables and further mitigated by entrances on the south (main) and north (employees). The south -facing porte cochere draws attention to the main entrance. A series of gables provides horizontal relief. As would be expected, windows are numerous which helps break down the mass. The side courtyard walls read as if the building exterior is continuous. Cultured stone serves as the base for the south elevation. The balance of the wall materials is a variety of cementious lap siding (7" reveal and 4" reveal) and cementious panel board. Colors are earth -tone and residential in character. H. Section 3.5.3(C)(1) — Orientation to a Connecting Walkway There are two direct walkways, one from each street, that connect the public sidewalks to a plaza, located at the building entrance, without having to cross a drive aisle. In addition, there Item # 2 Page 6 19 Agenda Item 2 C. Section 3.2.1(E)(5) —Parking Lot Interior Landscaping The parking lot exceeds 6% interior landscaping in the form of islands which exceeds the required minimum for lots with less than 100 spaces. D. Section 3.2.2(8) — Access Circulation and Parking The parking and circulation system is complete and capable of serving the expected number of staff on the largest shift, 22, as well as visiting medical and professional staff and visitors. The north -south private drive allows for connectivity between Precision Drive and Rock Creek Drive. E. Section 3.2.2(K)(3) — Parking Lots — Maximum Number of Spaces — Alternative Compliance This standard requires that for a Long Term Care Facility, the range of allowable number of parking spaces is between 0.5 per bed (required minimum) and .33 per bed plus one per two employees on the largest shift (allowable maximum). The P.D.P. includes 64 beds, 22 employees on the largest shift and a total of 51 spaces. There is no available parking on either public street so the 20% bonus is applicable. The P.D.P. exceeds the required minimum of 32 spaces. The maximum allowable number of spaces is 38. (64 x .33 = 21 plus 11 (employees) = 32 x 20% (bonus) = 6 + 32 = 38). The number of proposed spaces is 51. The P.D.P. exceeds the maximum allowable by 13 spaces. The applicant has indicated that the number of proposed parking spaces is based on existing facilities that are under current operation in other communities and is justified under the Alternative Compliance provision of Section 3.2.2(K)(3). The primary justification for the increase in the number of spaces is due to number of visiting professionals that provide services to the clients. These include primary care physicians, medical specialists, physical therapists, diagnosticians, social workers, hospice volunteers, beauticians, pet therapists and the like. These professionals and volunteers are not in-house employees but provide a wide range of services on a daily or weekly basis. In addition, there is shift overlap requiring the higher number of spaces so that parking does not spill off -site. Finally, the total anticipated employee count is 24 full-time equivalents which are divided among approximately 36 employees depending on the number of part-time employees. Staff finds that the request for Alternative Compliance represents a reasonable approach that accomplishes the purpose of the standard equally well than would a plan with less parking. For example, 39 spaces are located on the north side of the building along the shared property line with the pending Eye Care Center medical office building. This rear lot is not along a public street so it well -screened and has less visibility. Further, the perimeter of this parking lot includes a dense mix of trees and shrubs to soften the exposure. Bicycle parking is provided in excess of the standard and the site is served by Transfort Route #16. One factor in recommending approval of the Alternative Compliance is that the standard does not account for various programs and events that allow the residents to interact with the community. All Long Term Care facilities engage the services of an Activities Director who brings in community volunteers who offer a wide variety of programs and functions that socially engage the residents in order to combat isolation and withdrawal. These volunteers are often groups, not just individuals that may need the extra parking spaces. Item # 2 Page 5 18 Agenda Item 2 3. Compliance with the Harmony Technology Park, Seventh Amendment Overall Development Plan: By being located within the B.I.N.R.E.A.C. and zoned H-C, the Overall Development Plan is divided between 75% primary and 25% secondary uses. Windsong at Rock Creek is a Long Term Care Facility which is permitted in the H-C as a primary use. The parcel is located on Parcel C of the O.D.P. which is 42.55 acres and designated on the O.D.P. for Primary Uses. The project, therefore, complies with the approved Overall Development Plan. 4. Compliance with Applicable Harmony Corridor Zone District Standards: As mentioned, a Long Term Care Facility is a permitted primary use subject to review by the Planning and Zoning Board. The building is below the maximum allowable height of six stories. The applicant is participating with the master developer of the Harmony Technology Park to establish and comply with an integrated pattern of streets and streetscaping along Ziegler Road. For example, in conjunction with the pending Eye Center of Northern Colorado P.D.P. to the north, the following site plan elements of Windsong at Rock Creek are being coordinated: ❑ Both P.D.P.'s will share a north -south private drive along their respective east property lines that will connect Precision on the north to Rock Creek Drive on the south. This drive will be designated as a public access easement allowing for internal circulation without having to load local traffic onto Ziegler Road. ❑ Both P.D.P.'s will share a common emergency only access drive for the benefit of a providing a secondary access for emergency vehicles and equipment. ❑ Both P.D.P.'s are designing an integrated landscape along Ziegler Road that coordinates a common theme for over 800 feet of public street frontage. 5. Compliance with Applicable General Development Standards: A. Section 3.2.1(C)(D) — Landscaping and Tree Protection The P.D.P. provides full tree stocking around the entire site. Street trees are provided along both Ziegler Road (4-lane arterial) and Rock Creek Drive (collector with no parking). Foundation shrubs are provided around all sides. The screen walls that enclose the two courtyards on the east and west sides are mitigated by continuous rows of trees and shrubs including upright junipers for year-round effectiveness. B. Section 3.2.1(E)(4)(a) — Parking Lot Perimeter Landscaping There are 12 spaces in front (south) for visiting professional staff and guests. There are 39 spaces in the back (north). The 25 north -facing spaces are along the perimeter of the property are buffered by a mix of with shade and evergreen trees in excess of the minimum requirement of one per 40 feet. There is no adjacent residential area. Item # 2 Page 4 17 Agenda Item 2 Since 1997, the following annexations occurred: • Kendall -Harmony Annexation - June, 2000 • Johnson -Harmony Annexation - July, 2000 These annexations triggered cooperation among various land owners which created the Harmony Tech. Park, First Amended O.D.P. (267 acres) - September, 2000 In 2004, the Harmony Technology Park, O.D.P., Second Amendment was approved which added three residential properties and increased the total acreage of the O.D.P. from 267.19 acres to 270.19 acres. Since 2004, five additional amendments to the O.D.P. were approved in response to the great recession, parcel adjustment for various end -users, and re -allocation of the primary and secondary uses. The governing O.D.P. is the Seventh Amendment approved in 2014 and encompasses 270 acres among several property owners. The following projects have been approved in the Harmony Technology Park: Project Name Applicant/Use Year Site acres H.T.P. ls'Filing Celestica/Intel 1998 34.4 H.T.P. 2" Filing H-P South Campus 2001 60.14 Brookfield Townhomes Chateau Development 2002 42.39 H.T.P. 3 Filing Custom Blending 2008 5.01 Presidio A artments Multi -Family 2011 11.83 H.T.P. 3dFiling Numerica 2012 4.90 Milestone Apartments Multi -Family 2013 10.20 Banner Health Hospital 2013 27.95 H.T.P. 4 1h Filing Fuse Office 2014 1.62 Main Street Health Long Term Care 2015 7.5 The following projects are under current review: Project Name Proposed Use Site acres Harmony Commons Commercial Mixed -Use 4.00 Eye Center of Northern Colorado Medical Office 4.16 2. Compliance with Harmony Corridor Plan: The entire 270 acre O.D.P. is within the Basic Industrial Non -Retail Employment Activity Center (B.I.N.R.E.A.C). The proposed land use, Long Term Care, is a primary use in the H-C zone district. Development of the subject parcel, therefore, contributes to fulfilling the vision of the Harmony Corridor being an area reserved for a variety of business -related uses on relatively large parcels within an attractive industrial park setting. Item # 2 Page 3 16 Agenda Item 2 1 inch - 9 Windsong Long -Term Care Facility Comments: 1. The surrounding zoning and land uses are as follows: N: H-C Harmony Technology Park Eye Care/Northern Colorado P.D.P. S: L-M-N Fossil Ridge High School E. H-C Harmony Technology Park Vacant W R-L Wildwood Farm & Harvest Park Existing Residential The property was annexed as part of the 156 acre Harmony Farm in 1984 The first Harmony Technology Park Overall Development Plan consisted of 155 acres and was approved in 1997 in conjunction with Celestica Manufacturing. Item # 2 Page 2 15 Agenda Item 2 PROJECT NAME WINDSONG AT ROCK CREEK, PDP#150024 STAFF Ted Shepard, Chief Planner PROJECT INFORMATION PROJECT DESCRIPTION: This is a request for a P.D.P. for a long-term care facility located at the northeast corner of Ziegler Road and Rock Creek Drive on Parcel C of the Harmony Technology Park. The primary focus is to serve the needs of people living with Alzheimer's disease and other related dementia. The site is 3.34 acres. The one- story building will be approximately 37,000 sq. ft. and contain 64-beds arranged in individual apartments with central dining. There will be 51 parking spaces serving 22 employees on the largest shift, visiting professionals and guests. The parcel is located in the Harmony Corridor (H-C) zone district. APPLICANT: Vista Pointe Development Co., LLC c/o Lenity Architecture 3150 Kettle Court SE Salem, OR 97301 OWNER: Harmony Technology Park LLC 303 Detroit Street, Suite 301 Ann Arbor, MI 48104 RECOMMENDATION: Approval EXECUTIVE SUMMARY • The project complies with the policies of the Harmony Corridor Plan. • The P.D.P. is in conformance with the Harmony Technology Park Overall Development Plan, Seventh Amendment. • The P.D.P. complies with the land use and development standards of the H-C, Harmony Corridor, zone district. • The P.D.P. complies with the applicable General Development standards. • The site and landscape plans have been designed in coordination with the proposed P.D.P. to the north, Eye Center of Northern Colorado, with regard to public and emergency access and landscaping along Ziegler Road. Item # 2 Page 1 14