HomeMy WebLinkAboutDELLENBACH SUBARU - PDP - 50-98 - REPORTS - RECOMMENDATION/REPORT W/ATTACHMENTSC
STANDARD COMPETION - Use our Standard Competition design for areas that are suburban in nature or
where your facility is not competing with higher lighting level neighbors.
Greenbriar Series/Hilton Series
Assembly A
Spacing: 50'0"
Mounting Ht.: 24'0"
Initial footcandles at
3'0" above grade
Average: 68.11
Max/Min: 2.82
Assembly D
Spacing: 70'0"
Mounting Ht.: 24'0"
Initial footcandles at
TO" above grade
Average: 33.55
Max/Min: 2.19
Greenbriar Reduced Series/Challenger Series
Assembly A
Spacing: 50'0"
Mounting Ht.: 24'0"
Initial footcandles at
3'0" above grade
Average: 65.67
Max/Min: 3.99
Assembly D
Spacing: 70'0"
Mounting Ht.: 24'0"
Initial footcandles at
3'0" above grade
Average: 29.77
Max/Min: 2.34
0 10 20 30 40 50 6 70 80 90 100
I I _I I
0 4 8 12 16 20 24 28 32 36 40
®I I agl 1 1[� I I
°Seconds RIorKey
11
Vertical Burn 71hotometrics •
Through the use of innovative software, LSI Automotive can show you the LSI difference, visually. Easy to read color shading
indicates the light levels. Refer to appropriate color key at the bottom of the page for actual footcandle values.
HIGH COMPETITION - Choose LSI's High Competition design for auto malls and areas where the competi-
tive environment includes surrounding dealers and/or businesses that generate higher levels of lighting.
Greenbriar Series/Hilton Series
0 10 20 30 40 50 60 70
Fron Ro Co or Keyes
0 4 8 12 16 20 24 28
1 I '11 i ,.l
10 Secon ary,3Row Color Key
Assembly A
Spacing: 40'0"
Mounting Ht.: 24'0"
Initial footcandles at
3'0" above grade
Average: 83.08
Max/Min: 2.62
Assembly D
Spacing: 60'0"
Mounting Ht.: 24'0"
Initial footcandles at
3'0" above grade
Average: 38.56
Max/Min: 1.92
Assembly A
Spacing: 40'0"
Mounting Ht.: 24'0"
Initial footcandles at
3'0" above grade
Average: 79.67
Max/Min: 3.51
Assembly D
Spacing: 60'0"
Mounting Ht.: 24'0"
Initial footcandles at
3'0" above grade
Average: 34.14
Max/Min: 2.11
80
90
100
t .Z
32
36
40
LIGHTING SYSTEHS
GREENBRir-kR - FLAT LENS
DIMENSIONS
A
— A ----
_
Bracket-
2-boll
Arm Mount
Pattern
Pole Tap Mount
A B C
GFM Medium Arm Mount
21-SM
12-3/4'
—
GFPM Medium Pole Top
21.5/8'
12.3/4'
21.15/16'
GFL Large Arm Mount
26-1/8'
16.3116'
—
GFPL Large Pole Top
26.1/8'
16-3116'
26.13/i6'
LUMINAIRE EPA CHART E
Includes bracket. Pole Top
Mount
M„1
Single
D90'
0180'
T90'
TN720' Q90'
Medium
Greenonar - 12' Arm Mount Bracket GFM
3.2
5.7
6.3
8.8
9A
11.3
Greenbriar - Pole Top GFPM
Large
Greenbriar - 14' Arm Mount Bracket GFL
4.5
8.4
9.0
12.8
13.2
16.8
Greenbriar -Pole ToP (GFPLI
4.8
—
—
—
—
—
—
LUMINAIRE ORDERING INFORMATION select appropriate choice from each column to formulate order code. Refer to example below.
Luminalre
Lamp
Line
Luminaire
Prefix
Distribution
Wattage
Light Source
Lens
Voltage"'
Finish
Options
Medium
2 - Type II
250
HPS - High Pressure Sodium
F - Flat Tempered
480V
BRZ - Bronze
BBK- 8' Bracket' *
3-Type 111
400
250,400Wall
Glass
MT -Multi Tap""
BLK-Black
PCI120V-Button-Type Photoelectric Control
GFM-
FP - Perimeter
MH - Metal Halide
TT-Tri-Tap"""'
PLP- Platinum Plus
PC1208V-Button-Type Photoelectric Control
Arm
Mount
Forward Throw
250 Wall
BUF - Bull
PC1240V - Button -Type Photoelectric Control
5 -Type V Square
MHR - Metal Halide Reduced
WHT - While
PC1277V - Bullon-Type Photoelectric Control
GFPM-
Envelope Lamp
GRN - Green
LL - Less Lamp
Pale Top'
400 Wall
C - Coaled Lamp"
NO - No Options
Color Decals
Large
2 -Type It
750
HPS - High Pressure Sodium
FP - Perimeter
1000
750 Wall"
45 - Light Gold Metallic 55 - Black
GFL -
Forward Throw
MHR - Metal Halide Reduced
20 - Charcoal Metallic 50 - While
Arm
Mount
FA - Automotive
Envelope Lamp
94 - Blue Metallic 51 - Dark Red
Forward Throw
1000 Watt
59 - Dark Green
GFPL -
5 - Type V Square
21 - Tomalo Red
Pole Top'
EXAMPLE OF A TYPICAL ORDER 1 GFM 5 400 MH F MT BRZ NO
When ordering pole top fixtures for tenon mounting,
a pole top adaptor must be ordered.
"750W High Pressure Sodium not available in MT. Specify voltage required.
"'For international voltages, consult factory.
""MT -Multi Tap is shipped standard unless otherwise specified. Multi Tap consists of 120V, 208V, 240V, and 277V. Multi Tap is pre -wired for 277V.
Alternate voltages will require field re -wiring.
'An 8' bracket can only be ordered with single and 01 a0' configurations.
"Coaled lamps are not available in: 400W HPS (GFM), 750W HPS (GFL), 1000W MHR (GFL).
"'Tri-Tap is shipped standard for C-UL applications. Tri-Tap consists of 120V, 277V, and 347V. Tri-Tap is pre -wired for 347V. Alternate voltages will require field re -wiring.
ACCESSORY ORDERING INFORMATION (Accessories are field installed)
Description
Order Number
FK120V - Single Fusing
FK120V
FK277V - Single Fusing
FK277V
DFK208.240V - Double Fusing
DFK208, 240V
DFK480V - Double Fusing
DFK480V
FK347V - Single Fusing
FK347V
RPP - Round Pole Plate
6908901"
BKS-BO-WM-'-CLR Wall Mount Plate
123111CLR
GAM 2 HSS - House Side Shield
4342901"
GFPM 2 HSS - House Side Shield
4342901"
GFM 3 HSS - House Side Shield
4342902"
Description Order Number
GFPM 3 HSS - House Side Shield 4342902"
GFM FP HSS - House Side Shield 4342902"
GFPM FP HSS- House Side Shield
4342902"
GFL 2 HSS-House Side Shield
4342903"
GFPL 2 HSS - House Side Shield
4342903"
GFL FA HSS - House Side Shield
4342904"
GFPL FA HSS - House Side Shield 4342904"
GFL FP HSS - House Side Shield 4342904"
GFPL FP HSS - House Side Shield 4342904"
"Black
All HSS available are shown.
T' I GREENBRIAR° SERIES - AT LENS
GREENBRIAR
FLAT LENS
Designed to be a vanguard for the '90s, there's finally a comprehensive approach to
outdoor lighting. Greenbriar incorporates a high-performance vertical burn optical system
into a smart, economical housing. Strong in capability. Dependable without question.
Unique in value.
SPECIFICATIONS
HOUSING
The Greenbriar's aluminum
housing is finished to produce
a clean, sharp appearance and
designed to ensure weather -tight
construction. Top -access cover
provides ease of installation and
servicing. All pole -tap fixtures are
pre -wired.
LENS/GASKET
The Greenbriar's flat tempered
glass lens is sealed to the housing
with an EPDM gasket, preventing
entry of moisture and insects.
TOP FASTENERS
The Greenbriar's four captive
stainless steel fasteners secure the
top -access cover to the housing.
SOCKETS
Porcelain mogul -base sockets
feature spring -reinforced
contacts for long life.
LIGHT SOURCES
The Greenbriar is designed to
operate with any of the following
lamp types: High Pressure
Sodium or Metal Halide. Reduced
envelope lamps are utilized for
400 Watt Metal Halide in medium
fixtures and 1000 Watt Metal
Halide in large fixtures. Clear
lamp is supplied as standard.
PHOTOMETRICS
REFLECTORS/DISTRIBUTION
PATTERNS
The Greenbriar fixture is available
in five reflector systems and distri-
bution patterns, all with vertical
burn lamps: Type II (2), Type III (3)
(medium only), Type V Square (5),
Automotive Forward Throw (FA)
(large only), and Perimeter Forward
Throw (FP). Reflectors are field -
rotatable, enabling generous
flexibility in distribution patterns
without fixture movement.
Photometric data is certified by
an independent testing facility.
FINISHES
Each Greenbriar fixture is finished
with DuraGrip", LSI Lighting
Systems' revolutionary superior
baked -on polyester -powder finishing
process, to give the fixture an
exceptionally attractive appearance.
Standard finish colors available for
the Greenbriar are bronze, black,
platinum plus, buff, white, and
green. The DuraGrip polyester finish
withstands extreme weather changes
without cracking or peeling. Finish is
guaranteed for five full years.
DECAL STRIPING
To complement the fixture's
appearance, a color -coordinated
decal is available in 8 standard
decal colors or by custom order
from a selection of hundreds.
Decal is guaranteed for five years
against peeling, cracking, or fading.
750W High Pressure Sodium 1000W Metal Halide
GFL — Type V Square GFL — Type V Square
Vertical Burn Vertical Burn
3MH 2MH 1MH 0 3MH 2MH 1MH 0
ONEN 3MH NONE 310H
NN 2MH NOS
1MH N�lf7r 1MH
N D E
Milt.
e A �1MH A r01MH
MNODS— 2MIiC`n,.yw_v,,, 2MH
ONO 3MH 3MH
SEEN
Front Front
Lumen Rating 110,0D0 Lumen Rating 110,000
MTG.
BALLAST
High -power factor ballast with
removable ballast tray. Metal
Halide and High Pressure Sodium
fixtures feature a type CWA ballast.
All ballast types are designed for
-20' F operation.
BRACKETS
Arm Mount: 2-1/2' x 6' x 12' length,
extruded aluminum bracket shipped
standard with medium luminaires
(GFM). Fourteen -inch arms are
shipped standard with large
luminaires (GFL) only. (An 8'
bracket is available in single and
D180' configurations, but must be
ordered from the Options column
of the ordering chart.) A Round
Pole Plate (RPP) is required for
mounting to 3'-5' round poles.
Pole Top: The cast aluminum
mounting hub conceals wiring
compartment and mounting
hardware (consisting of four
11/16' O.D. aluminum rods for
medium fixtures and 7/8' O.D.
aluminum rods for large fixtures,
and a high -strength grade -five steel
bolt with nylon insert and split lock
washer for double locking).
POLES
Refer to Poles/Brackets section
of catalog for pole information.
R CO
listed for wet locations.
Levels shown are in loolcandles.
L/GH77NG SYSTEMS
10000 Alliance nond • P.O. Box 42728 • Cincinnati, Ohio 45242-0728 • (513) 793-3200 • FAX (513) 984-1335
No Text
Dellenbach Subaru Page 2
Project 9875 June 14, 1999
the majority of the offsite light pollution and make the light pollution level 20-0" from the Site
.property Line negligible. Note: "the existing light levels 20' -0" from the site property lines are
much higher than 0.1 foot candles and we would question whether or not the adjacent lighting
levels conform to the current land. use code. In short, the off site light pollution is negligible 20'-
0" from the property line, when -you consider the high competition environments this site is
located in. .
1 . ' Per the direction of Leanne Harter, formally of the City's Planning Department, we have
modeled the site lighting after Spradley Barr Ford, an existing car dealership in the City of Ft.
Collins. According to Ms. Harter, the City has shown,acceptance to this type of lighting and in
the future will use Spradley Barr Ford;a's,the'example of acceptable car dealership parking lot
lighting. Enclosed are Cutsheets of the;cutoff-lighting sources -that will be utilized, similar to
fixtures utilized at Spradley Barr"Ford. Theicontrol'of the lighting system will also emulate
Spradley Barr Ford's Control System. It will progressively shutdown. certain lights at certain
times after dark so the lighting.level will eventually be minimized and be utilized for security
purposes only., Enclosed are photometrics showing''the light levels at_various proposed times of
shut down.
Per Steve Olt's request; the'following'is a list of `existing jobs'that the City Is planners can us as
a comparison of footcandle levels produced on,photometric plans to their actual deal world
appearance.
The first was for Spradley Barr and the,foo'tcandle`levels along the main display area running
parallel with College Avenue had average light levels -of 40FC. Toward the back of the lot the
lighting.was averaging 15 to 20 FG. This,is whatDellenbach Subaru was modeled after and will
most resemble.
The second layout was -for Steele's Market Center; and'under the maiwparking lighting, which
was Sterner 1000 watt metal halide, the average was I FC:..'The decorative fixtures around the
perimeter were used for decorative and path lighting —The average level'along the path was a
range from 1.5 to 2 FC average.
The third layout was for Ed Carroll Motors-Porsche/Audi and this was just for general site
lighting. The average FC level for the entire site was 22 FC. The levels along the front of the lot
where cars are displayed was 45 to 50 FC.
In reality, the light layout of the site in question will be at a lower level than it's surrounding
sites. To remove more lighting and totally�conform to theiand Use Code would most definitely
make the site dark in comparison to its surroundings.
N
t
Nuff
A550CI4TES, INC. RONALP J. OUTT - P.E.
ELECT2ICAL ENC,INEER.S
June' 14, 1999
Carr Bicker
The Architect's Studio
151 West Mountain Ave., Suite 100
Ft. Collins, CO 80524
RE: Dellenbach Subaru
Project No. 9875
Dear Mr. Bicker,
The Photometric Site Layout to be submitted on the above mentioned project to the City of Ft.
Collins Planning Department, shall be submitted.under the'City's Alternative Compliance of the
Land Use Code.
It is important to note that to successfully illuminate a car dealershipsales parking area, higher
foot candles are required than the land use code allows.", -The location of the land in question is
also of importance, bordered by existing'car dealerships•to the north and south, College Avenue
to the east and a Napa Auto Parts to�the westindicates the land is, in a competitive environment
that generates a higher level of lighting. Enclosed�is an example,of Car Dealership Industry `
Standards for lighting. Notice that for high' competition environments an average footcandle level
for the First Row of Display Cars is 60 to 80 FC while the 2nd Row has an average of 35 to 45
F.C. The requirements for standard competition, (which this site is clearly not, it is a high
competition environment), have an average foot-candle level for the First Row of Display Cars
of 50 to 70 F.C., while the 2n1 Row has an average of 30 to 40 F.C. The re -submitted Photometric
Site Layout clearly indicates the site in question will have light levels far below the industry
standards for high competition or standard competition environments.
The Land Use Code also has a stipulation of the amount of off site light pollution allowable. The
code indicates that no more than 0.1 foot candles is allowed at a distance of 20'-0" from the site
property line. The re -submitted Photometric Site Layout indicates that there are points where
this appears to be in violation. However, the computer program used to create the Photometric
Site Layout is not.capable of accounting for natural obstructions. As shown on the Architectural
Site Plan an array full grown trees surround the site in question and are to remain in there
existing locations as the site is developed. In reality, the trees surrounding the site will consume
1013 57T11 AVENUE COURT
SUITE 200
CREELEY. COLORADO 80634
e-mail: rjmcnutt@concentric.net
A
C,REELEY (970) 356-3093
DENVER (303) 654-041,
F4X (970) 351-0903:
• ` FT. COLLINS: (970) 686-5678
parking will be used for dealer inventory. An existing bus stop along College Avenue will have a
direct connection to a north -south sidewalk, without the current difficulty of crossing the
Frontage Road. In addition, new sidewalk access will be provided at the northeast comer of the
site, as well as a mid -block ramp along West Swallow Road. Elsewhere, new sidewalks will
merge with existing sidewalks, having negligible impact on existing pedestrian movement along
adjacent sites.
The new service area, new second level and existing brick structure will all receive a stucco finish.
Because the existing building has already been painted several times, and several existing openings
will be modified, it was decided that a stucco overcoat would provide the most homogeneous
finish and an opportunity to marry the existing building to the new through a shared vocabulary of
finishes. Included in this vocabulary is a stacked stone tower (a Subaru icon) at the southeast
comer of the existing building, as well as a 6' high band of stacked stone at the base of the new
service building. As a whole, the building will utilize neutral and earth tone stucco, stacked stone,
and several trellises and armatures to provide an appropriate regional aesthetic. In addition, the
latter will also serve to protect entrances, reduce solar gain, and provide a way to proliferate
plantings and landscaping. This vocabulary of materials also reinforces the human scale, by
creating a band of rich materials at the pedestrian level, as well as creating protected zones at
prominent points of entry and pedestrian interaction.
The site landscaping, while fulfilling Land Use Requirements, is also integrated into the overall
aesthetic of the building. Although not explicitly required by the Land Use Code, a screening
hedge has been proposed between the subject site and the adjacent commercial site to the west
Foundation plantings have been included where feasible. At the entrance to the building, potted
annuals have been proposed in lieu of foundation beds to alleviate concerns regarding
maintenance, particularly in front of glazing which extends to the floor he. The potted annuals
will also provide significant color and seasonal appeal. To the east of the building, an area has
been developed which is intended to enhance the natural appeal of the site as well as provide an
extension of the client's retail opportunities. A surface that allows significant permeability (or the
introduction of turf between pavers) will be employed for the display of 3 to 4 automobiles
adjacent to the building. Surrounding this display will be an area landscaped with heavy boulders
and indigenous "alpine" plants and perennials. This landscaped area is intended to extend both the
function and aesthetic of the building towards the street in the spirit of "New Urbanism". The
landscape plan calls for many "low" and `very low" water use plants, and should allow for an
efficient irrigation scheme. Proposed plant species are diverse, and have been selected and located
based upon the abilities of each to thrive in specific conditions. Consideration has also been given
to the seasonal fluctuation of foliage and density.
In summary, this project will provide an appropriate "outdoors" aesthetic through the use of
forms, building and plant materials. It will also provide extensive improvements to vehicular and
pedestrian access to the site, as well as continuity and accessibility to the contiguous Dellenbach
Chevrolet site. It is anticipated that this site will serve as a catalyst for future proposals to
eliminate and reconfigure the Frontage Road at locations which positively effect vehicular and
pedestrian accessibility, safety, and the overall quality of the South College Avenue commercial
corridor.
PROJECT DEVELOPMENT PLAN
PLANNING OBJECTIVE
Submitted by Carr Bieker
of the Architects' Studio
September 18, 1998
Subject Property: Dellenbach Subaru
The subject property is located at the southwest comer of South College Avenue and Swallow
Road. The proposal incorporates the existing one story'Round the Corner restaurant into an
expanded Subaru auto dealership, showroom and vehicle service facility. The subject property is
contiguous to the Dellenbach Chevrolet property to the south and some of the proposed
improvements affect this collective site area.
In an effort to improve vehicular traffic flow to, from and through both the northern Subaru and
southern Chevrolet sites, the proposal calls for the abandonment of the Frontage Road from the
Dellenbach property to West Swallow Road. In conjunction with the elimination of this portion of
the Frontage Road, the proposal pursues right turn in and out access to South College Avenue.
This new access would service both of the Dellenbach sites mentioned above as well as the Bank
property to the south. Both the City and CDOT responded favorably to this proposal in December
1997.
The Transportation Impact Study (August 14, 1998) concluded that the proposed Dellenbach
Subaru would generate 146 fewer daily trips than the existing `Round the Comer restaurant. This
reduction in trip generation, coupled with improved site access and dedicated circulation between
the Dellenbach sites validates the abandonment of the Frontage Road. In addition, the Storm
Drainage Report (September 8, 1998) predicts that hard surfaced areas within the Frontage Road
ROW will be reduced by 68% as a result of this proposal (removal of existing roadway and
replacement with turf and landscape material). The net hard surfaced area of the entire project site
will also be decreased. As proposed, the current Frontage Road ROW to the east of the subject
property will be vacated, and subsequently utilized and addressed as part of the subject site.
Although the existing structure does not quite lay within 15' of the build to line at Swallow Road,
the proposed adjacent addition will be located at 15' from the build to line. Similarly, there will be
no parking between the building and adjacent roadways, apart from several dealer cars displayed
on a landscaped pads. In this manner, the proposed building addresses the Land Use Code's
concern for maintaining proximity to both vehicular and pedestrian arteries. The major parking
volume is located to the south of the building, where it is best serviced by the proposed new right
in from College Avenue to the south of the subject site. This minimises the distance traveled and
the amount of vehicular interaction required upon entering the site. The building use is split
between "general office" (3 spaces per 1000 sf) and "vehicle service and maintenance" (5 spaces
per 1000 sf). With a proposed building area of 12,275 sf +/-, the maximum allowable parking is
42 spaces. The proposed scheme provides 20 spaces dedicated to customer parking, as well as a
three bicycle ribbon rack located adjacent to the showroom entrance. The remaining onsite
Wrl secarm �evo. - IIIICCO,
Max
f..l
WYLaa07 /MMe! m01
GIM11lL
jS
%
Fefx 111LL1/. ■IICRi®
H Te 1100! TO aUILDM/
m
,,:.,.
•M:e
OTILI®OIOIE !'IWN1 -dfT
�^
■
NO e110II1 MIX MIGx
'�'�
�lle0
. ..
enema 111114'! odes ewsnw
^'�
lit on am mm
wal.onu, Mwx
Rr veenens Tc R ocmom
6UlDINO
Mai maoe.m. motto AWNr.
ELEVATI 46
SOUTH ELEVATION
morewahr eram�l
.p.NO.
8C.ALE: IIB'^1'-0"
mae AWy+oN mac ar
exremm vemeae
ore m,,.f
s
eev moot[ aINL91w. aTY.GO,
❑ ❑
❑
Micx
Ll''
�
DCGORA1rve 6.ROR, MWx
ED
El
pe{IeLG I✓Hlrlb AIlDLYI!
:.�^^a
='v:: 'I'" i ..
,.
mrcr® mare AWlM M mmc
1
or aeevt¢ ell.oiw M1arm1
J�y/
eorl
L,L.
NORTH ELEVATION
Q
]Xa�
cc
T�ew+e7 A'JaD
RMW V�mei
AIM!
T .
.L
P
Q
I
D�AAOML Sim
m
� ,n�
mlw
Z
KJROI „m
ne. ooal MJM
AItXOVr YIOOD M1AIYCO
.;
IOR CLMV'rY
`fl
—�
motto raaw ro
.:
mcrxo more
...
e'OfC
Q
P
..
AWmI ATftNAA
mac
Oa'e1 e'.AJ
L — — —
— — J LJ
PROJECT
DEVELOPME
PLAN
EAST ELEVATION
n
WEST ELEVATION
TRASH ENCLOSURE
EL
9
ve'=r-m
s scALE: va•=r-0
scU e: , ,'-0^
SO.
4
_
" i^'°err-..��
WE8T8WALLOW 1•vW
ww
� •:.:.�.--. _
"
1'\
CEO
w•u1e
_ �
1W I fICrI /NY<
I
p
t
x,l
N
\.
i
t,
yyCC
1
PRA�y1Nb LEGEND
®MJ® P91BaaK x!D
Of�_LANDSCAPE PLAN
k 8C4LE:1"=30-0 caNcf
OIr, nw, A
_•ww"s wsN
PLANT LIST
m. •wwea Iavw Iwe •1lwar IwJ•NM•
ulnr rrtlf�
•
IAr fYlYI1N
!Y
♦
Yr IIMWiR
SM NM1
f
/M
!Y lYN
f
NyS 111wf N1
!Y
q•W!•K
YYY i•�
i T'AxxN N•N IfY
xw�
tag.P.WrYYrf
•YYtll
Y►
Y�r
1 Jlrrl
• ri axn+.rw1
wY
Vlflgn
•
•fws
u
ar
• JII JI•/1
•W1A
urnfrw
• ✓R ♦Iww
•fYs
lwW'1
rer
IrwlxN wrr
• flw �w •wa•x IYIn Nr
YYYr Y\t
i (.. r� NWYI
IYYM
1f
• VIr ••�
IYYf#
Yf
• N I�ar�• Nf
IYY41
VfrlwEn
'Jf
•W4N
\Y'IOIn
foif
wwYYf•
YiIN-rTLT.NVIw iY/.aR•WTW
NYW N4h/101•
NOI N••rw•Aw•rM Mr VMYM•C MbNM
LANPWAPE WATER USE GATEOMIES
4DsaNt xYW6rw
M Y/Y
Nw.1aRMrll�xn
nienw• -
rr�•sMt•YYi r
uwn Mm f
YSf1Y•Mfrllll%
•NNJa w•a a nnlreNuwrvm N wnrwvnm m ww..r •. Mmm
LMIDSGAPE NOTES
M1 MMCI• M4• bR m Y rMld INI� MI WKMTC MIM:M IINd MO N KGC•dlGi TM
M4m1YtM!•.
lµL:IrrW rYiLi llx NlMw AI•Nr41p.
x ne YYm•nlr.Nrurlw'sc J♦r JwlwcNn•wrw we uuwl wrwmnr
�wrs w • ewer Iwn ne w•wwwl•Rlr• wrtl rvw wr J, urltl r r•er, •x•s••Rw
•ola avw:.n-aw •wsm rxwu w ♦ wrrrwr a• xolwc..
n w JulJawrxrrwrw rxutl srrfo wwlw urltlwwvr,rwwwn Nlx.srawil
R�R�,M,I.wwMM:xWfbN MRMIAM IAIWMIIrMIwI
xNNfMm•NSlwxlMNrl tlIrCI T•YMV INI MIY{xlR awIWIMN tlIwm [Tn
MM.VI/Y Nr•wxlMN1411NW M Wx Ml wrrx
U law�e i•r•.ww unJrtl Nrw W wxml•.
i •ns wrw wNwwwNxonw TW wrrar•IN wrw Nris oAr•r NII•iPY
nvl Jwe•uxlm, •Ifr w w>ww w ne vJc Yi w Mr.
N Im Wr!• •N•c W Rlxr uY• s xwn lulw
mo wxo •.r.vllDm •Im rwNmrYamrwe•vwmr rr
w NL wwV Iffavo N mf m s i®e.
U rwiltm tallwcmlJu Ymx \®Yst m m s lav faux ll! •werzTN IeN•esR
rwa wtl1Ye r •wnJxlw wm new w w M IaN rauN Ipw Ir ran
r ML RNf MYxW NVIn NKCcwC/1ax' rM AM rnifl•AY Rw wIY{M WR
r Ju m! ww mtl wrap wm N Mewlc norf Nww.ami mma NL MrY JN:IrY m
r wIW1NY MII N WINMK aw! f11fAx /M\w wTM n rIOIINf K1lWWRIL M w•Mw
MIM x m s N.YItl m N•fM M}r MYM aT! M1TVL N.VIt IM
W aMLtw x m Ylr TMT M WAUI• NM• IN! rWIGMwD rM M NNr tN! •r OIIR
I•�aJa nwrrbwKx wnw f�vx uwcrxe°�'Ydesnonw wxrwew as lor<wum ww
r Mn, W ilwnuwww nwllr M1gf1A�N+fr. ww.lwn wrl ra•lJc�m xwa a nrlYNa.
MM AMR wAT 1AV1�lYI1• Arl®NYI�Iw• IWIRxW1 wTAOYL1RAiMC;
r �• w• Mw•wrnwr wwa�•Mmrtlf iwrt rrJ Nww. wwwcw N41 w aw.N.tl wil
usuewxxl•rrrw J.w Nx
I LP I
2
SITE PLAN
SCALI'13AP
PRAVVK& LEGEND
B
R
o
vl9 y l A MAIAIW
a
pIp VICINITY MAP �
Yn s
UILQRATV SEVATM�w
B5 L
Fig �
Qj�5 kEITIFICATION
D
co
PLANNING AND ZONING BOARD OMTIFIGATIO
L
z
Lu
ui
a
PROJECT
DEVELOPMENT
PLAN
I SP
I
VICINITY MAP 09/30/98
#50-98 Dellenbach Subaru (LUC)
PDP - Type II
1"= 600'
No Text
Dellenbach Subaru, PDP - #50-98
August 5, 1999, Planning & Zoning Meeting
Page 13
LUC equally well than would a lighting plan which complies with the
standards of the Section.
C. The DELLENBACH SUBARU, PDP is compatible with the surrounding land
uses.
RECOMMENDATION:
Staff is recommending approval of the request for an alternative site lighting plan for the
DELLENBACH SUBARU, Project Development Plan, in accordance with Section
3.2.4(E) - Alternative Compliance of the LUC.
Staff is recommending approval of the DELLENBACH SUBARU, Project Development
Plan - #50-98.
Dellenbach Subaru, PDP - #50-98
August 5, 1999, Planning & Zoning Meeting
Page 12
This proposal complies with the purpose of the C - District as it provides community and
regional retail automobile sales and service in a community/regional shopping area of
Fort Collins (the South College Avenue corridor has historically been considered a
community/regional shopping center). The retail portion of the operation is the new auto
display and sales. This Dellenbach Subaru Automobile Dealership is an auto -oriented
facility in an area along South College Avenue that includes automobile dealerships
and retail/commercial uses. The site has been designed to provide and emphasize safe
and convenient pedestrian movement from the South College Avenue sidewalk system
to the public entries into the facility.
Section 4.17(E) Development Standards
The proposal satisfies the applicable development standards in the C - Commercial
Zoning District.
5. Findings of Fact/Conclusion:
A. The DELLENBACH SUBARU, PDP contains uses permitted in the C -
Commercial Zoning District, subject to review by the Planning and Zoning Board.
B. The DELLENBACH SUBARU, PDP meets all applicable standards as put forth in
the LUC, including Division 3.2 - Site Planning and Design Standards,
Division 3.5 - Building Standards, and Section 3.6 - Transportation and
Circulation, with the following exception:
standards located in Section 3.2.4 - Site Lighting Levels of ARTICLE 3 -
GENERAL DEVELOPMENT STANDARDS. An alternative lighting plan,
in accordance with Alternative Compliance (Section 3.2.4(E)] in the LUC,
has been submitted for consideration.
The proposal incorporates an innovative computer controlled
lighting system that varies the light levels over the course of an
evening and early morning hours and mitigates off -site light spillage
and glare. Staff finds that the alternative plan for the proposed
computer controlled lighting system (successively diminished
lighting levels) for the Dellenbach Subaru Automobile Dealership is
in accordance with prior auto dealership lighting plans and
accomplishes the purposes of Section 3.2.4 Site Lighting in the
Dellenbach Subaru, PDP - #50-98
August 5, 1999, Planning & Zoning Meeting
Page 11
The DELLENBACH SUBARU, PDP satisfies all applicable Building and Project
Compatibility standards.
Section 3.5.3. Mixed -Use, Institutional and Commercial Buildings
The DELLENBACH SUBARU PDP satisfies all applicable Mixed -Use, Institutional
and Commercial Buildings standards.
C. Division 3.6 - Transportation and Circulation
Section 3.6.4. Transportation Level of Service Requirements
The proposal satisfies the applicable Transportation Level of Service standards (see
the attached Traffic Impact Study), including the following:
General Standard. This development proposal satisfies Section 3.6.4(B), which
requires that all development plans adequately provide vehicular, pedestrian and
bicycle facilities necessary to maintain the adopted transportation Level of
Service standards contained in Part II of the City of Fort Collins Multi -Modal
Transportation Level of Service Manual for the following modes of travel: Motor
vehicle, bicycle and pedestrian.
4. ARTICLE 4 - DISTRICTS
A. Division 4.17 - Commercial District
Vehicle sales and leasing establishments with outdoor storage are permitted in the C -
Commercial Zoning District, subject to Planning and Zoning Board (Type II) review. The
purpose of the C - District is:
Intended to be a setting for development, redevelopment and infill of a wide
range of community and regional retail uses, offices and personal and business
services. Secondarily, it can accommodate a wide range of other uses including
creative forms of housing.
While some Commercial District areas may continue to meet the need for auto -
related and other auto -oriented uses, it is the City's intent that the Commercial
District emphasize safe and convenient personal mobility in many forms, with
planning and design that accommodates pedestrians.
Dellenbach Subaru, PDP - #50-98
August 5, 1999, Planning & Zoning Meeting
Page 10
is considered to be a "commercial value" area for outdoor display and sales of a
product versus primarily security and safety for patrons using a standard
commercial parking area.
a. Dellenbach Subaru is proposing an alternative lighting plan because it
would provide a uniformity of on -site lighting for better rendition of auto
display. The uniformity is improved if there are more poles that are lower
and closer together.
The proposed light fixtures are 25' in height and the light source
will control the lighting on the perimeter of the site.
Changing the light source wattage to a lower level would be
dramatic and would not be adequate for this type of commercial,
outdoor display of automobiles.
b. The Dellenbach Subaru lighting system would produce an average
lighting level of 7.02 to 1.08 foot-candles over the site. A lighting plan
designed to meet the maximum lighting level of 10 foot-candles overall
would probably not be as good as the proposed system. There would be
fewer poles, due to the lower wattage, and they would have to be higher
than the proposed 25' for adequate distribution. These fixtures may create
more light spillage and off -site glare than the proposed lights.
C. This development proposal incorporates an innovative computer
controlled lighting system that varies the light levels over the course of an
evening and early morning hours and mitigates off -site light spillage and
glare.
Staff finds that the alternative plan for the proposed lighting system for the
Dellenbach Subaru Automobile Dealership is in accordance with prior auto
dealership lighting plans and accomplishes the purposes of Section 3.2.4 Site
Lighting in the LUC equally well than would a lighting plan which complies with
the standards of the Section.
B. Division 3.5 - Building Standards
Section 3.5.1. Building and Project Compatibility
Dellenbach Subaru, PDP - #50-98
August 5, 1999, Planning & Zoning Meeting
Page 9
than in a parking lot for other businesses. The functional needs of this
proposed project essentially cannot be met at a maximum lighting level of
10 foot-candles.
b. The proposed solution meets the functional needs of -the project in a way
that does not adversely affect the adjacent properties or neighborhood.
Not only is there virtually no light spillage beyond the property lines, the
average level on the site through the night will be substantially less than
the 10 foot-candles allowed in the LUC.
C. A proposed state of the art computer controlled lighting system (similar to
that being used on the existing Spradley Barr Ford site south of Harmony
Road) would decrease the affects on the adjacent properties and
neighborhoods and would result in energy savings. The site would be fully
illuminated for only a few prime shopping hours each evening.
d. The lighting levels on the Dellenbach Subaru site would be below those of
other auto dealerships. Average lighting levels on this site at full
illumination would be 7.02 foot-candles, with some "spot' levels up to 41.8
foot-candles. Average lighting levels on the site at non -prime shopping
hours (after hours) would drop to 1.08 foot-candles, with some "spot'
levels up to 10.6 foot-candles.
Three Photometric Plans (for proposed lighting from dark to closing, from closing
to 1 hour after closing, and from 1 hour after closing until morning for security)
and copies of cut sheets for the proposed lighting system have been submitted
for review by staff and the Planning and Zoning Board.
Staff Response:
City staff considered many different types of land uses when the design
standards for site lighting were discussed and implemented into the LUC. The
purpose of the maximum allowable lighting levels City-wide of 10 foot-candles,
except for loading and unloading platforms where the maximum lighting level
shall be 20 foot-candles, was a conscious decision to attempt to significantly
decrease outdoor lighting levels throughout the City for differing land uses. As
part of development review for Dellenbach Subaru, staff considered the
difference between lighting levels in higher activity parking areas and the
proposed subject Dellenbach Subaru automobile dealership. Dellenbach Subaru
Dellenbach Subaru, PDP - #50-98
August 5, 1999, Planning & Zoning Meeting
Page 8
Spradley Barr's control system. It will progressively shut down certain
lights at certain times after dark so the lighting level will eventually be
minimized and will be utilized for security purposes only.
d. In reality, the site lighting for the Dellenbach Subaru Automobile
dealership will be at a lower level than its surrounding sites. To remove
more lighting and totally conform to the Land Use Code would definitely
make this site dark in comparison to its surroundings.
e. Examples of 3 existing sites have been included to use as comparisons of
lighting foot-candles to this proposed site. This information has been
produced based on photometric plans to their real world appearance:
* Steele's at Market Center — Under the main parking lot lighting
(Sterner 1000 watt metal halide) the average is 1 foot-candle. The
decorative fixtures around the perimeter are used for decoration
and path lighting. The average light level along the path is a range
from 1.5 to 2 foot-candles.
* Ed Carroll Motors, north of the subject site — The average foot-
candle level for the entire site is 22 foot-candles. The levels along
the front of the lot (toward South College Avenue) where cars are
displayed are 45 to 50 foot-candles.
* Spradley Barr Ford, south of Harmony Road — The foot-candle
level along the main display area running parallel with South
College Avenue have light levels of 40 foot-candles. Toward the
back of the lot the lighting is averaging 15 to 20 foot-candles. This
site is what the Dellenbach Subaru lighting plan is modeled after
and will most resemble.
In addition, the applicants would like to offer the following information:
a. Because the nature of the proposed land use requires that the products
available for sale (in this case, automobiles) must be predominantly
displayed outdoors, this type of business is more susceptible to vandalism
than most other businesses. The customers must examine the products in
the outdoors and, therefore, the safety and visibility are more important
Dellenbach Subaru, PDP - #50-98
August 5, 1999, Planning & Zoning Meeting
Page 7
The applicant cited the following reasons for consideration of the Alternative
Compliance request:
a. To successfully illuminate a car dealership sales parking area, higher foot-
candles are required than the Land Use Code allows. The location of the
land in question is also of importance, bordered by existing car
dealerships to the north and south, South College Avenue to the east, and
a NAPA Auto Parts store to the west indicates the land is in a competitive
environment that generates a higher level of lighting. The Car Dealership
Industry Standards for lighting show that for high competition
environments an average foot-candle level for the first row of display cars
is 60 to 80 foot-candles, while the second row has an average of 35 to 45
foot-candles. The requirements for standard competition (which this site
clearly is not, it is a high competition environment) have an average foot-
candle level for the first row of display cars of 50 to 70 foot-candles, while
the second row has an average of 30 to 40 foot-candles. The Photometric
Plans for the site indicate that this site will have lighting levels far below
the industry standards for standard or high competition environments.
b. The Land Use Code has a stipulation regarding the amount of allowable
off -site light pollution. The code indicates that no more than 0.1 foot-
candles is allowed at a distance of 20' from the site property line. The
Photometric Plans indicate that there are points where this appears to be
in violation. However, the computer program used to create the
Photometric Plans is not capable of accounting for natural obstructions.
As shown on the Site and Landscape Plans, an array of full grown trees
surround the site and are to remain in their existing locations as the site is
developed. In reality, the trees surrounding the site will consume the
majority of the off -site light pollution and make the light pollution level
negligible 20' from the property line.
C. Per direction from a representative of the City Current Planning
Department, this site lighting has been modeled after the existing
Spradley Barr Ford Dealership located on the west side of South College
Avenue south of Harmony Road. According to the Planning Department,
the City has shown acceptance of this type of lighting and in the future will
use the Spradley Barr site as the example of acceptable car dealership
parking lot lighting. The control of the lighting system will also emulate
Dellenbach Subaru, PDP - #50-98
August 5, 1999, Planning & Zoning Meeting
Page 6
foot-candles at 20' beyond the property line. These figures represent the site
lighting at full illumination (dark to closing). The proposed computer controlled
lighting system for this facility will progressively shut down certain lights at certain
times after dark so the lighting levels will eventually be minimized and utilized for
security purposes only. The "front row", site lighting, and off -site levels exceed
the standards as set forth in Sections 3.2.4(D)(7) & (8) of the LUC and, therefore,
the applicant has submitted to City staff and the Planning and Zoning Board for
review an alternative lighting plan (see attached) based on the criteria as set
forth in Section 3.2.4(E) Alternative Compliance. Upon request by an applicant,
the Planning and Zoning Board may approve an alternative lighting plan that
may be substituted in whole or in part for a plan meeting the standards of this
Section.
(1) Procedure. Alternative compliance lighting plans shall be prepared and
submitted in accordance with submittal requirements for lighting plans as set
forth in this Section. The plan shall clearly identify and discuss the modifications
and alternatives proposed and the ways in which the plan will better accomplish
the purpose of this Section than would a plan which complies with the standards
of this Section.
(2) Review Criteria. To approve an alternative plan, the Planning and
Zoning Board must first find that the proposed alternative plan accomplishes the
purposes of this Section equally well or better than would a lighting plan which
complies with the standards of this Section.
In reviewing the proposed alternative plan, the Planning and Zoning Board shall
consider the extent to which the proposed design protects natural areas from
light intrusion, enhances neighborhood continuity and connectivity, fosters
nonvehicular access, and demonstrates innovative design and use of fixtures or
other elements.
Applicant's Request:
The applicant has stated that Section 3.2.4(D)(7) of the LUC, calling for a
maximum on -site lighting level of 10 foot-candles, was written to address
common patron or employee parking areas and did not recognize other functions
such as lighted athletic fields, product display (such as automobile dealerships),
or outdoor performing arts facilities that cannot meet the stated purpose of the
Site Lighting section of the code.
Dellenbach Subaru, PDP - #50-98
August 5, 1999, Planning & Zoning Meeting
Page 5
This development proposal exceeds the standard for Parking Lot Interior
Landscaping as set forth in Section 3.2.1(E)(5), providing 8% interior
landscaping in the auto display, sales, and customer parking lots.
Screening. The proposal satisfies the standard relating to the screening
(Section 3.2.l(E)(6)] of areas of low visual interest or visually intrusive site
elements (such as trash collection, open storage, service areas, loading docks,
and blank walls) from off -site view.
The trash enclosure and used oil container are located on the west side of the
building and are included within walls to match the building. Landscape shrubs
will provide additional screening from West Swallow Road. The service area and
maintenance -related activities are on the southwest portion of the building and
they are set back a significant distance from and out of view from South College
Avenue.
Section 3.2.2. Access, Circulation and Parking
The proposal satisfies the applicable Access, Circulation and Parking standards,
specifically the following:
Directness and continuity of walkways. The development proposal satisfies
the standards (Sections 3.2.2(C)(5)(a)(b)] that walkways within the site shall be
located and aligned to directly and continuously connect areas or points of
pedestrian origin and destination, and shall not be located and aligned solely
based on the outline of a parking lot configuration that does not provide such
direct pedestrian access. Also, where it is necessary for the primary pedestrian
access to cross drive aisles or internal roadways, the pedestrian crossing shall
emphasize and place priority on pedestrian access and safety.
The development proposal provides for a sidewalk network that includes
attached sidewalks along the Frontage Road and West Swallow Road. A primary
pedestrian walkway will be provided from the attached sidewalk to the building.
Lighting. The lighting levels of the proposed Dellenbach Subaru Automobile
Dealership would be a maximum of 41.8 foot-candles on the "front row" display
areas (closest to the public right-of-way of the Frontage Road along South
College Avenue), an average of 7.02 foot-candles on the site, and up to 0.84
Dellenbach Subaru, PDP - #50-98
August 5, 1999, Planning & Zoning Meeting
Page 4
3. ARTICLE 3 - GENERAL DEVELOPMENT STANDARDS
This DELLENBACH SUBARU, PDP proposal meets all of the applicable standards in
ARTICLE 3 - GENERAL DEVELOPMENT STANDARDS of the LUC, with the
exception of Section 3.2.4. Site Lighting. The applicant has submitted an Alternative
Compliance request for review of those standards which have not been met. Of specific
note are Division 3.2 - Site Planning and Design Standards, Division 3.5 - Building
Standards, Division 3.6 - Transportation and Circulation. Further discussions of
these particular standards follow.
A. Division 3.2 - Site Planning and Design Standards
Section 3.2.1. Landscaping and Tree Protection
The proposal satisfies the applicable Landscaping and Tree Protection standards,
including the following:
Street trees. The street tree planting is in accordance with Section
3.2.1(D)(2)(a), with existing trees at 25' - 40' on -center in the 23' wide
landscaped parkway between the Frontage Road and South College Avenue.
Also,
Parking lot landscaping - perimeter and interior. Parking lot landscaping for
this project is in accordance with the standards, including those related to
Parking Lot Perimeter Landscaping (Section 3.2.1(E)(4)(a) and (b)] and Parking
Lot Interior Landscaping (Section 3.2.1(E)(5)].
Trees are being provided in the 13' wide landscape setback area between the
automobile display parking and the Frontage Road. These trees, integrated with
the trees in the landscaped island between the Frontage Road and South
College Avenue, are spaced at 25'. The spacing of the trees, in conjunction with
the plant material understory (shrubs), provides for adequate screening of the
parking areas. This meets the standard for Parking Lot Perimeter Landscaping
as set forth in Section 3.2.1(E)(4)(a).
The screening for the South College Avenue frontage will consist of a
combination of deciduous and evergreen shrubs, minimum of 30" in height,
extending a minimum of 70% of the Frontage Street along the parking lot,
meeting the requirements of Section 3.2.1(E)(4)(b).
Dellenbach Subaru, PDP - #50-98
August 5, 1999, Planning & Zoning Meeting
Page 3
COMMENTS:
1. Background:
The surrounding zoning and land uses are as follows:
N: C - Commercial; existing auto dealership (Ed Carroll Motors)
S: C - Commercial; existing auto dealership (Dellenbach Chevrolet)
W: C - Commercial; existing retail (NAPA Auto Parts)
E: C - Commercial; existing commercial/retail/office (South College Avenue
commercial corridor)
This property was annexed into the City as part of the South College First Annexation
in November, 1970.
The property was originally subdivided and platted as Lots 1 & 2 and part of Lot 3 of the
Swallow Subdivision on October 18. 1973. It was replatted as 'Lots 1 & 2 and part of Lot
3 of the Replat of Swallow Subdivision on August 3, 1976.
The Planning and Zoning Board approved the Round The Corner Restaurant and the
Long John Silver's Restaurant on Lots 1 & 2 and the eastern 30' of Lot 3 on January
10, 1977. The Long John Silver's Restaurant has since gone out of business, the
building has been removed, and the site is being used for parking for the Round The
Corner Restaurant.
2. ARTICLE 2 - ADMINISTRATION
Section 2.2.2. Step 2: Neighborhood Meetings
The DELLENBACH SUBARU, PDP contains a proposed land use that is permitted as a
Type II use, subject to review by the Planning and Zoning Board. The proposed use is
automobile display, sales, and service. The LUC requires that a neighborhood meeting
be held for development proposals that are subject to Board review unless the Director
determines that the development proposal would not have significant neighborhood
impacts. It was determined that it was not necessary to hold a neighborhood meeting
for this proposed automobile dealership in the South College Avenue
community/regional shopping corridor that has no direct relationship to any residential
neighborhoods.
Dellenbach Subaru, PDP - #50-98
August 5, 1999, Planning & Zoning Meeting
Page 2
* standards located in Division 3.2 - Site Planning and Design Standards, with
the exception of Section 3.2.4. Site Lighting (the applicant has submitted an
Alternative Compliance request for review of the standard which is not being
satisfied), Division 3.5 - Building Standards, and Division 3.6 -
Transportation and Circulation of ARTICLE 3 - GENERAL DEVELOPMENT
STANDARDS;
* and the applicable district standards located in ARTICLE 4 - DISTRICT
STANDARDS of the LUC (Division 4.17 C - Commercial Zoning District).
Vehicle sales and leasing establishments with outdoor storage are permitted in the C -
Commercial Zoning District, subject to Planning and Zoning Board (Type II) review. The
purpose of the C - District is:
Intended to be a setting for development, redevelopment and infill of a wide
range of community and regional retail uses, offices and personal and business
services. Secondarily, it can accommodate a wide range of other uses including
creative forms of housing.
While some Commercial District areas may continue to meet the need for auto -
related and other auto -oriented uses, it is the City's intent that the Commercial
District emphasize safe and convenient personal mobility in many forms, with
planning and design that accommodates pedestrians.
This proposal complies with the purpose of the C - District as it provides community and
regional retail automobile sales and service in a community/regional shopping area of
Fort Collins (the South College Avenue corridor). The retail portion of the operation is
the new auto display and sales. This Dellenbach Subaru Automobile Dealership is an
auto -oriented facility in an area along South College Avenue that includes automobile
dealerships and retail/commercial uses. The site has been designed to provide and
emphasize safe and convenient pedestrian movement from the South College Avenue
sidewalk system to the public entries into the facility.
ITEM NO. 4
MEETING DATE 8/5/99
STAFF Steve Olt
Citv of Fort Collins PLANNING AND ZONING BOARD
STAFF REPORT
PROJECT: DELLENBACH SUBARU, Project Development Plan - #50-98
(Type II, Planning and Zoning Board Review in the Land Use
Code)
APPLICANT: The Architects' Studio
c/o Carr Bieker
151 West Mountain Avenue
Fort Collins, Colorado 80524
OWNERS: Dellenbach Motors
c/o R. Michael Dellenbach, President
3111 South College Avenue
Fort Collins, CO. 80526
PROJECT DESCRIPTION:
This is a request for a Project Development Plan (PDP) for an automobile dealership,
showroom, and vehicle service facility. The property is located at the southwest corner
of South College Avenue and West Swallow Road and is contiguous to the existing
Dellenbach Chevrolet dealership that is to the south. The facility would contain one
10,400 square foot building that would be one and two stories, up to 28' in height. The
site is 1.08 acres in size and would contain 16 spaces for customer parking and 52
spaces for auto display. The property is in the C - Commercial Zoning District.
RECOMMENDATION: Approval
EXECUTIVE SUMMARY:
This Project Development Plan complies with the applicable requirements of the Land
Use Code (LUC), more specifically:
the process located in Division 2.2 - Common Development Review
Procedures for Development Applications of ARTICLE 2 -
ADMINISTRATION;
COMMUNITY PLANNING AND ENVIRONMENTAL SERVICES 281 N. College Ave. P.O. Box 580 Fort Collins, CO 80522-0580 (970) 221-6750
PLANNING DEPARTMENT