Loading...
HomeMy WebLinkAboutPALMER DESIGN CENTER - PDP - 47-98 - CORRESPONDENCE - PHOTOMETRIC PLANl3SS, ,hound Straight Steel Vas Itttft� TECHNICAL INFORMATION EPA RF) with 1.3 gust Catalog Number Nominal mounting height (feet) Pole Shah Size (inches It feet) wall Thickness (inches) 70 mph 00 mph 90 mph 100 mph Max. weight Bob Circle (inches) Boft Size lin. x in. x in.) Approximate ship weight (pounds) RSS 8 4-5B 8 4.5 x 8 0.121 31.6 24.5 19.4 15.7 393 8 3i x 18 x 3 72 RSS 10 4-5B 10 4.5 x 10 0.121 25.7 20 15.8 12.7 318 8 3S x 18 x 3 84 RSS 12 4-5B 12 4.5 x 12 0.121 21.1 16.4 12.9 10.5 263 8 'A x 18 x 3 96 RSS 144-5B 14 4.5x14 0.121 17.2 1 13.4 10.5 8.5 8 '/x18x3 108 RSS 154-5B 15 4.5x15 0.121 15.7 12.0 9.4 7.5 8 34x18x3 114 RSS164-5B 16 4.5x16 0.121 14.4 11 8.6 6.9 fl40 8 '/ax18x3 120 RSS184-5B 18 4.5x18 0.121 11.7 9 7 5.6 B 3/ax18x3 132 RSS 204-5B 20 4.5x20 0.121 9.7 7.4 5.7 4.5 113 8 3Sx18x3 144 RSS 22 4-513 22 4.5 x 22 0.121 8.1 6 4.6 3.6 100 8 N x 18 x 3 156 RSS 24 4-5B 24 4.5 x 24 1 0.121 1 6.51 4.6 13.6 12.7 1 100 1 8 1 Nix 18 x 3 168 RSS 30 4-56 30 4.5 x 30 1 0.121 1 3.21 2.1 1.3 0.9 1 100 1 8 1 3/ x 18 x 3 204 BASE DETAIL POLE OPTIONS Suffix Description FOL 1.1 Festoon Outlet - less electrical FGL 1-2 Festoon GFI Outlet - less electrical HI-18S 1 Horizontal Arm Bracket - 1 fixture VO Vibration Damper let UAB Less Anchor Bolts HH' Extra Handhole Handhole Cover NOTES: 1 Specify location orientation when ordering (specify orientation from handholet. PORTANT: 2 Consult factory for more information hese specifications are intended for general purposes only. Lithonia reserves the right to concerning festoon outlets. ange material or design, without prior notice, in a continuing effort to upgrade its products. 3 Combination of Tenon -top and drill mount utallation requires grout to be packed under base to ensure lull contact with foundation. requires extra handhole. ' • LIMUMIA L/GAMMO - POLE 2525- SPECIFICATION OUTDOOR LIGHTING Lithonia Lighting, Rev. ary6 S POLE.PMS 1615 EAST ELMORE ST.. CRAWFORDSVILLE. INDI/ 7933. TELEPHONE 317 362-1637. FAX 317 362AJM IN CANADA_ 1100 50TH AVE.. LACHINE. OU HST 2V3. A UNIT OF N.S.I. HOLDINGS. INC. FEATURES SHAFT— Weldable -grade ASTM 513 carbon steel tubing with a minimum yield of 55,000 psi. Uniform wall thickness of .121'. Shaft is one-piece construction with a full longitudi- nal weld. The 4-1/2'round straighttube is uniform in cross- section down the length of the shaft. ANCHOR BASE — Fabricated from carbon steel plate (ASTM A-36), 3/4' thickness. Base plate and shaft are circumferentially welded at both the top and the bottom to provide maximum strength at the area of critical stress. HANDHOLE — Nominal 3x5' handhole is located 18' above the base. Cover and attachment hardware provided. GROUNDING — A nut holder located immediately inside the handhole is provided with a 1/2'— 13 UNC ground bolt and nut ANCHOR BOLTS — Top 12' is galvanized per ASTM A-153. Made of carbon steel bar with a minimum yield strength of 55,000 psi. HARDWARE — Fasteners are high -strength galvanized zinc - plated or stainless steel. TOP CAP — Plastic cap is standard for drill -mount poles. FINISH — Dark bronze (DDB► polyester powder finish stan- dard. Other architectural colors available. BASE COVER —Automotive-grade ABS plastic full -cover fin- ished to match pole. ORDERING INFORMATION Choose the boldface catalog nomenclature that best suits your needs and write it in the appropriate blank. RSS a Shaft type Nominalmounting RSS height 8 — 30 feet fSee back page.) Nominal shaft base size/ wall thickness Type ..... �Y.S..:r. :.. ...:5..-.PT.-.dWA.:..................-..... Catalognumber.......................................................................................................... CUM Anchor Base Poles RSS 4-56 (See back page.) Shaft Bolt Bolt Base Anchor Warehouse Template Base Circle Projection Square Bolt Anchor Bolt Number Size A B C Description Description 4-1/2' 8' 3-1/4'-3-1/2' 8' ABRSS-4 AB18-0 PJ50041 IMPORTANT: • Do not erect poles without fixtures in place. • Factory -supplied templates must be used when setting anchor bolts. Lithonia will not accept claim for incorrect anchorage placement due to lailure to use factory template. • If poles are stored outside. protective wrapping paper and cardboard must be removed immediately to prevent finish damage. I� LInva /A L/GHT/NG SPECIFICATION OUTDOOR UGHTING 4-1/2' O.D. ROUND STRAIGHT STEEL 8' to 30' Mounting Example: RSS 20 4-58 OM19 DDB Mounting Options Tenon Mounting Architectural Colors (powder finish): PT Ope ccents KKR series tandard Colors T20 2.3/8' O.D. (2' NPS) DOB Dark bronze T25 2-7/8' O.D.12-in' NPS) DWH White T30 3-1/2' 0.D.13' NPS DBL Black Drill Mounting Classic Colors DM19' 1 at 900 DMB Medium bronze OM28' 2 at 180° DNA Natural aluminum DM29' 2 at 90" DSS Sandstone DM32' 3 at 120' DGC Charcoal gray DM39' 3 at 90' OTG Tennis green DM49' 4 at 901 DBR Bright red DSR Steel blue NOTES: 1 Drill pattern is for Lnhonia Architectural Outdoor fixtures unless otherwise specified 2 Additional architectural colors available: see paint brochure. 125-POLE SEP 15 198 8:56 FROM I-IGHTING AGENCY FEATURES rC Iyj�Vno TO CED rT COLLINS PAGE.002/002 T p, AvT ; ; , os - R3- - I�-T gS - D1r.1 }A HOUSING — Cylindrically-s'taped, rugged, heavy -gauge, spun alu- minum housing with tort -less top access. Fully gasketed for weather -tight integrity. >tandard finish is dark bronze (DOB) polyester powder. Other architectural colors available. LENS — 3/16'thick, clear, impact -resistant. tempered drop lens. MOUNTING — Extruded aluminum Term with integral splice com- pariment for wail or pole mounting Is shipped in fixture carton. Optional mountings evei'able. OPTICS — Segmented, anodized aluminum optics are inter- changeable and rotatable. Vertically tamped sealed optics in- clude ASY (asymmetric;, SYM (symmetric), SYMN (symmetric narrow) and PFT (perimeter forward throw -asymmetric). De- sign redirects light around arc -tube for optimum lamp life and maximum efficiency. Three horizontally tamped cutoff distribu- tions include Type II (rot dwayl, Type III (asymmetric) and Type IV (forward throw). ELECTRICAL SYSTEM — Constant -wattage autotransformer bal- last. Ballast is copper w3und and 100% factory tested. Remov- able power tray and positive locking disconnect plug. SOCKET —Mogul -base porcelain socketwith copper alloy, nickel - plated screw shell and tenter contact UL listed 1500W-600V, 4KV pulse rated. _.. . LISTING — UL listed suiteLle for wet locations. Listed and labeled to comply with Canadia:i Standards (see Options). < ORDERING INFORMATION Goose the bownce, catalog norxrxdstun tit best swn write it on the appropriate nne. order accession. at WI KVR2400S *-4)� Z KSVeseeriess I Voltage tevl� Distribution Vertical ASY Asymmetric 7 SYM Symmetric 0 SYMN Symmetric narrow TO' PFT Perimeter forward throw asymmetric Horizontal R2 IES Type ll roadway 11 lU IES Type HI asymmetr-: R4 IES T e V forward it row tadr00 numee, Area Lighting 400S 40OW HIGH PRESSURE SODIUM 25' to 35' Mounting =0,W~AT#r Hirig Standard All dimerciorus an incAes A roam I : n naae el wnleas mtar ue EPA•1.5fe 4irtll '1.6fe(.ISMspecified. (includes fine uders stnAs) Diu ' r. Diameter..25(635) Heig 5) Height 1"4(34.3) - ,1 SM Overall Height ZI-7/9 (60.61 5 kg) Weight: 7S (34 kg) Example: KVR240OS SYM 12O RPVDMSF W 77 Options , are pole (4- anne Shipped Installed Ill frumrre Architectural Colors (powder finish)' nd pole (Carm)t W SF Single fuse (IM, 277,347V) Standard Colors ats pole (6'arm)OF Double fuse l208, 240.480V1 DOB Dark bronze (standard) �RPVDO6 Round pole 16' arst) )standard) PER NEMA twist -lock receptacle WH Whi[ SPVD09 Square pole (9- arm) only (no phowcontrol) UBL Black RPVD09. Round pole (9- arm) HS House side shield (R2. and R3 Classic Colors SPV012 Square pole (12' arm) only) OMB Medium bronze RPVD12 Round pole 417' arm) US Ouera restrike system (25OW DNA Natural aluminum max, 120V lamp not included) WWVD09 Wood pole or wall (9' arm) DSS Sandstone WBVD09 Wall bracket (9- arm) EC Emergency circuit DGC Charcoal gray CR Corrosion -resistant OTC Tennis green Optional Mounting CSA Listed and labeled to comply with Canadian Standards ORR Bright red DSO Steel blue yp PT4 Post -top mourn (4' open top Dotal Shipped Separately' Stripive PT45 Post -top mount (4-1st- open mp PEI NEMA twist -lock PE ()20. SODS Dark bronze pole 208,24M SDWHWhite ►TS Post -top mourn IS' open top PE3 NEMA twist -lock PE (347v) SDBL Black NOTES: polel PE4 NEMA twist -lock PE (4a0V) SOMA Natural aluminum 1 Optional multi -tap ballast 412), 203. 260. 277V). PT6 Post -top mount (6' open top in PE7 NEMA twist -lock PE (277V) Sandstone 1120. 277, 347V Canada). pole) SOSS a Tng SPVDo6. RPvD06. SPVDOa, RP11009, Swots, SC Shorting cap SDTG Tennis green w RPVD12, muss be used w n two Or more tummarras an oriented on a -IV 6ra6n(i pattern. SUBS Bright red 3 May be ordered as aouasory. SBLM Dark blue metallic 4 Omer architactursl cobra A!Pr- l ZIW sea pairs SCHM Charcoal metallic brochure. 5 For arm mouming, rater to trchrmal inn 6eetion SGLM Light gold metallic in the outdoor binder for drili ng templrta: Accessories: Tenon Mounting SAPrMer Moum0114 ODlion nrmnn Telnelste n Color K is;iarate Catalog number. Use with WeNres auaede far round pole SPVDXtiRPVDxx 5 ..rind. waVD" 6 VJWVD. 7 Number of lirturc: 1 ] 6 Fee striping, add the prefix '::' in from of desired color. (i.e. Tenon O.D. One Tw90180' TwoaW') Threa®120'fhreeon* Four*W' $OWN for white striping.) 7 The RPV0o4 RPVDW. or R►V012, must be used when 1-o or 2-7/8' T25.190 TZS-2so T25-29o' TZ5-3ZD TZS390 T25-4m more Iumlnwes are oriented on a 9V drilling pattern. a' T3S79a T3SZee T3S-2W 1735S T3S-390 T35-M FA,j.j73VojvjA ucyruva ARCHITECTURAL OUTDOOR UGH'fING 7504 VR2 ** TOTAL PAGE.002 ** NW.UNITED ELECT. 303 482 3866 P.02 NORTHWEST UNITED ELECTRIC, mrc. January 12, 1999 Frank Vaught VF Ripley Associates 113 Stoney Hill Drive Fort Collins, CO 80525 Ref: Palmer Design Center Project Development Plan #47-98 (Revised) Dear Frank, This letter is in response to the City of Fort Collins Community Planning and Environmental Services review letter for the above referenced project. Item 13 questions how the lighting foot-candle levels were brought into compliance of the = Section 3.2.4 maximum 10 foot-candle level. The following changes were made to the original lighting plan: 1. The number of pole light fixtures was reduced from a total of 9 fixtures to 5 fixtures. 2. The light poles were increased in height from 20 feet to 24 feet. Please contact us if you have any questions or if any additional information is needed. Sincerely, en ' Walters Estimator 800 STOCKTON AVE. #1 • FORT COLLINS, CO 80524 • 484-4699 - FAX 482-3866 JAN-12-1999 16.12 303 482 3866 96% P.02