Loading...
HomeMy WebLinkAboutCARRIAGE HOUSE APARTMENTS - FDP - FDP130024 - CORRESPONDENCE -Comment Numoer: 1 Comment Originated: 06/25/2013 06/25/2013: Repeat comment from PDP: The two water services in Shields connect to the water main in the east half of Shields (see redlines). Comment Number: 2 Comment Originated: 06/25/2013 0612512013: Repeat comment from PDP: Are there any irrrigation taps included in the project? (None shown and no Building C as noted in the response comments). Topic: Landscape Plans - Comment Number: 4 Comment Originated: 06/20/2013 06/20/2013: Please mask the text in hatched areas on sheet PDP 3. See redlines. Comment Number: 5 Comment Originated: 06/20/2013 06/20/2013: There are line over text issues on sheet PDP 3 & PDP 3A. See redlines. Topic: Lighting Plan Comment Number: 6 Comment Originated: 06/20/2013 06/20/2013: There is a line over text issue on sheet PDP 4. See redlines. Topic: Plat Comment Number: 7 Comment Originated: 06/20/2013 O6/20/2013: The text is still cut off at the top of the sheet. If this is going to be a problem when printing, please remove the text. See redlines. Topic: Site Plan Comment Number: 8 Comment Originated: 06/20/2013 06/20/2013: There are line over text issues on sheet PDP 2. See redlines. Comment Number: 9 Comment Originated: 06/20/2013 06/20/2013: Please make the property lines the same linetype as shown in the legend. See redlines. Comment Number: 10 Comment Originated: 06/20/2013 06/20/2013: The scale of sheet PDP 2 needs to be changed. Per Development Review Submittal Requirement #5, the scale must be either 1 "-50' or V-30'. Department: Traffic Operation Contact: Ward Stanford, 970-221-6820, wstanford(a,fcgov.com Topic: General Comment Number: 1 Comment Originated: 06/25/2013 O6/25/2013: Traffic Op's is requesting the bus stop shown on Shields Street be designed as a pull-out stop. Traffic has concerns with a vehicle being stopped in the roadway on the heavier congested roadways. There may be a school sign in the vicinity but Traffic is willing to remove the sign for the bus pull-out. Department: Transportation Planning Contact: Emma McArdle, 970-224-6197, emcardle(a)fcgov.com Topic: General Comment Number: 2 Comment Originated: 06/25/2013 06/25/2013: It came to Transfort's attention that due to traffic concerns in this area, the City's Traffic Department would prefer to have a bus pullout in this location. Transfort is not opposed to this and is willing to work with the applicant as needed to make this work. Please contact myself and Ward Stanford to figure out how to make this work. Department: Water -Wastewater Engineering Contact: Roger Buffington, 970-221.6854, rbuffington c( fcgov.com Topic: Construction Drawings Comment Number: 1 Comment Originated: 06/25/2013 O6/25/2013: All prior fire department concerns have been addressed. No further comment unless the site plan changes. Please contact me if you have any further need. Department: Stormwater Engineering Contact: Jesse Schlam, 970-218-2932, jschlam(a�fcgov.com Topic: General Comment Number: 7 Comment Originated: 06/26/2013 06/26/2013: The Erosion Control Materials need to address the following. 1) Saw Cutting BMPs 2) Sequence Plans and Chart 3) Site Specific Erosion Control Details in Appendix B (Urban Drainage is not specific enough) 4) 1 need to see something that talks about and addresses how you are planning on minimizing the access to the permiable pavers to avoid materials being placed on top and in effect clogging the drainage medium. Contact: Wes Lamarque, 970416-2418, wlamargue(a)fcgov.com Topic: General Comment Number: 1 Comment Originated: 06/25/2013 06/25/2013: The parking lot detention area may still spill to the south rather than to the north with the existing contours as shown. There should be a minimum of one -foot of freeboard from the spill location to all other locations around the pond. Comment Number: 2 Comment Originated: 06/25/2013 06/25/2013: Please revise the report to a Final Drainage Report rather than Preliminary. Comment Number: 3 Comment Originated: 06/25/2013 06/25/2013: The outlet pipe for the parking lot detention pond needs to be 12 inches minimum. Comment Number: 4 Comment Originated: 06/25/2013 06/25/2013: Please add a detail for the outlet works for restricting the flow to .57 cfs. This should be placed in an inlet on private property. Comment Number: 5 Comment Originated: 06/25/2013 06/25/2013: Please provide a subgrade grading plan for the parking lot detention excavation. Comment Number: 6 06/25/2013: Please add a porous pavement section detail. Department: Technical Services Contact: Jeff County, 970-221-6588, jcountyAfcgov.com Topic: Building Elevations Comment Number: 2 06120/2013: No comments. Topic: Construction Drawings Comment Originated: 06/25/2013 Comment Originated: 06/20/2013 Comment Number: 3 Comment Originated: 06/20/2013 06/20/2013: Please mask the text in the hatched area on sheet PV1. See redlines. Topic: General Comment Number: 1 Comment Originated: 06/20/2013 06/20/2013: Now that this project is in final review, please remove PDP and/or Preliminary Development Plan from all sheets. We are okay with changing the PDP sheet numbering to FP. Comment Number: 1 Comment Originated: 06/26/2013 O6/26/2013: Since a street tree cannot be planted where the bus stop is located consider/evaluate adding 2-3 upright ornamental trees such as Red Barron Crabapple in the lawn area behind the sidewalk and east of Building 4. These could add a nice buffer for the building and help meet the full tree stocking standard. Comment Number: 2 Comment Originated: 06/26/2013 0612612013: Please add this sentence at the end of Landscape note number 14. To protect existing trees from root damage do not cultivate more than 2 inches deep within drip zone of existing trees. Comment Number: 3 06/26/2013: Comment Originated: 06/2612013 Please add tree protection specification LUC 3.2.1 G 7 with the table that addresses standards for boring under the root system of existing trees. Comment Number: 4 Comment Originated: 06/26/2013 06/26/2013. Provide the table showing final full inventory of all existing trees with Size, species, condition and intent to remove or retain of all trees on the project. Comment Number: 5 Comment Originated: 06/26/2013 06/2612013: Upsize the Chanticleer Pear and Radiant Crabs to 2.5 inch caliper to meeting the mitigation size requirement for ornamental trees. Comment Number: 6 Comment Originated: 06/26/2013 06/26/2013: Clearly and distinctly label on sheet PDP 3A the Tree Mitigation Plan all trees that will be retained on the project. Include them is a separate table that is labeled Trees to Retain and Protect. Comment Number: 7 Comment Originated: 06/26/2013 06/2612013: Will boring be performed for utilities between building 1 and 2 as mentioned in the comment responses? Comment Number: 8 Comment Originated: 06/26/2013 06/26/2013: Consider using a Canopy Shade Tree species other than Ash due to the threat of Emerald Ash Borer getting into our area in the future. Department: Light And Power Contact: Doug Martine, 970-224-6152, dmartine(a fcgov.com Topic: General Comment Number: 1 Comment Originated: 06/03/2013 06/03/2013: The locations shown for the electric transformers is acceptable with the assumption that no form of electric space heating will be used. The utility plan shows "GM" on each building, which is assumed to mean Gas Meters. There is no location shown for the electric meters. Comment Number: 2 Comment Originated: 06/17/2013 06/17/2013: After the plans are complete and approved, please send an AutoCad drawing (version 2008) of the utility plan to Terry Cox at TCOX@FCGOV.COM. Department: PFA Contact: Jim Lynxwiler, 970416-2869, jlynxwilera(�poudre-fire.org Topic: General Comment Number: 1 Comment Originated: 06/17/2013 O6/17/2013: On sheet PDP2 under Site Description, second paragraph, 97 bedrooms is still called out. Please correct this to 89 bedrooms. Comment Number: 2 Comment Originated: 06/17/2013 06/17/2013: It was noted that buildings 2 and 3 are handicapped accessible, yet all three handicapped spaces are located in front of building 2. Department: Engineering Development Review Contact: Tyler Siegmund, 970-221.6501, tsiegmund(a)fcgov.com Topic: General Comment Number: 1 Comment Originated: 06/26/2013 06126/2013: Please label and provide more information on the curb/retaining wall behind the new Eft attached sidewalk along Springfield. Add note to the utility plan. Comment Number: 2 Comment Originated: 06/26/2013 06/26/2013: The limits of the proposed curb and gutter replacement at the SW corner of Springfield/Shields needs to extend to the handicap ramp as discussed during the site meeting due to the existing Hollywood curb/gutter that currently ties into the handicap ramp. Comment Number: 3 Comment Originated: 06/26/2013 0612612013: The 6ft attached sidewalk needs to extend to the property line to the west. Utility coordination with COFC Light and Power and Comcast/Century Link to movelmodify the existing utility layout will be needed to extend the 6ft walk. It is suggested that a pedestrian rated Light and Power vault be incorporated into the sidewalk. Comment Number: 4 Comment Originated: 06/26/2013 O6/26/2013: The (2) water services in Shields St that are to be abandoned need to extend to the main and show approximate patching limits. Comment Number: 5 Comment Originated: 06/26/2013 06/26/2013: The stairs to building 1 from the public sidewalk are in right-of-way. Please move onto private property. Comment Number: 6 Comment Originated: 06/26/2013 O6/26/2013: Remove the truncated domes from the drive approach Comment Number: 7 Comment Originated: 06/26/2013 06/26/2013: Revise note # 34 under General Notes to reference written approval by the City of Fort Collins not Larimer County. Comment Number: 8 06/26/2013: Add the standard note to the plat: Comment Originated: 06/26/2013 There shall be no private conditions, covenants or restrictions that prohibit or limit the installation of resource conserving equipment or landscaping that are allowed by Sections 12-120—12-122 of the City Code. Department: Forestry Contact: Tim Buchanan, 970-221-6361, tbuchanancDfcgov.com Topic: Landscape Plans City Of Fort Collins June 26. 2013 Charles Bailey Catamount Properties, Ltd. 7302 Rozena Drive Longmont, CO 80503 RE: Carriage House Apartments, FDP130024, Round Number 1 Community Development and Neighborhood services 281 North College Avenue PO Box 580 Fort Collins, CO 80522 970.221.6750 970.224.6134 - fax kgov. com/developmentre view Please see the following summary of comments from City staff and outside reviewing agencies for your submittal of the above referenced project. If you have questions about any comments, you may contact the individual commenter or direct your questions through the Project Planner, Courtney Levingston, at 970-416-2283 or clevingston@fcgov.com. Comment Summary: Department: Current Planning Contact: Courtney Levingston, 970416-2283, clevingston a( ,fcgov.com Topic: Building Elevations Comment Number: 1 Comment Originated: 06/17/2013 06/17/2013: For building B, the meters are shown on the east elevation. This is directly in view of the public street. The code requires that the utility meters, vents, ect. are located so they are not visible from the public street. For Building B #4, the meters should not be located on the north or east elevation and for Building B #5, it should not be on the east elevation. Please relocate. Comment Number: 2 Comment Originated: 06/17/2013 06/17/2013: For building C, they height should be called out from the top of the roof, not the bearing. This is per the City's of Fort Collins Land Use Code requirements on measuring height. Please rectify. Topic: General Comment Number: 1 Comment Originated: 06/26/2013 06/26/2013: Please put the note to bore utilities on the construction docs. Topic: Landscape Plans Comment Number: 1 Comment Originated: 06/17/2013 06/17/2013: On the plant list, there are two, upsized Skyline Honeylocusts called out, however there is only one shown on the landscape plan. Please rectify. Topic: Site Plan